Why I did it
Support pddf to as4630/as7816/as7326
How I did it
Send needed file to the PR for these platform
How to verify it
Test sensors and show platform cmd.
root@as7326-56x-3:/home/admin# show platform psustatus
PSU Model Serial HW Rev Voltage (V) Current (A) Power (W) Status LED
PSU 1 FSF045-611 FSF0451912000505 N/A 12.06 5.50 66.00 OK green
PSU 2 FSF045-611 FSF0451912000568 N/A 12.00 5.50 66.00 OK green
root@as7326-56x-3:/home/admin# sensors
lm75-i2c-15-4a
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +35.5 C (high = +80.0 C, hyst = +75.0 C)
lm75-i2c-15-4b
Adapter: i2c-1-mux (chan_id 6)
CPU Board Temperature: +29.0 C (high = +80.0 C, hyst = +75.0 C)
fan_ctrl-i2c-11-66
Adapter: i2c-1-mux (chan_id 2)
fan1: 9100 RPM
fan2: 9400 RPM
fan3: 9300 RPM
fan4: 9600 RPM
fan5: 9000 RPM
fan6: 9100 RPM
fan7: 9100 RPM
fan8: 9300 RPM
fan9: 9200 RPM
fan10: 9400 RPM
fan11: 9200 RPM
fan12: 9400 RPM
pch_haswell-virtual-0
Adapter: Virtual device
temp1: +43.0 C
psu_pmbus-i2c-17-59
Adapter: i2c-1-mux (chan_id 0)
in3: +12.06 V
fan1: 6272 RPM
temp1: +37.0 C
power2: 60.00 W
curr2: +6.00 A
lm75-i2c-15-49
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +40.0 C (high = +80.0 C, hyst = +75.0 C)
lm75-i2c-15-48
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +39.0 C (high = +80.0 C, hyst = +75.0 C)
psu_pmbus-i2c-13-5b
Adapter: i2c-1-mux (chan_id 4)
in3: +12.00 V
fan1: 6144 RPM
temp1: +36.0 C
power2: 66.00 W
curr2: +5.50 A
coretemp-isa-0000
Adapter: ISA adapter
Package id 0: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 0: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 1: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 2: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 3: +50.0 C (high = +82.0 C, crit = +104.0 C)
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
Why I did it
Support for show platform temp/fan for psu-temp and fan.
Original code doesn't has fan_drawer to support these information.
How I did it
Support for show platform temp/fan for psu-temp and fan.
Add fan_drawer.py and update thermal.py to add needed code.
It need PDDF common code to support . (Refer to #10213)
How to verify it
Test show platform temp and show platform fan.
root@as7726-32x-2:~# show platform fan
Drawer LED FAN Speed Direction Presence Status Timestamp
Fantray1 green Fantray1_1 38% EXHAUST Present OK 20220311 08:13:04
Fantray1 green Fantray1_2 38% EXHAUST Present OK 20220311 08:13:04
Fantray2 green Fantray2_1 38% EXHAUST Present OK 20220311 08:13:04
Fantray2 green Fantray2_2 38% EXHAUST Present OK 20220311 08:13:04
Fantray3 green Fantray3_1 38% EXHAUST Present OK 20220311 08:13:04
Fantray3 green Fantray3_2 38% EXHAUST Present OK 20220311 08:13:04
Fantray4 green Fantray4_1 38% EXHAUST Present OK 20220311 08:13:04
Fantray4 green Fantray4_2 38% EXHAUST Present OK 20220311 08:13:04
Fantray5 green Fantray5_1 38% EXHAUST Present OK 20220311 08:13:04
Fantray5 green Fantray5_2 38% EXHAUST Present OK 20220311 08:13:04
Fantray6 green Fantray6_1 38% EXHAUST Present OK 20220311 08:13:04
Fantray6 green Fantray6_2 38% EXHAUST Present OK 20220311 08:13:04
N/A green PSU1_FAN1 23% EXHAUST Present OK 20220311 08:13:04
N/A green PSU2_FAN1 22% EXHAUST Present OK 20220311 08:13:04
root@as7726-32x-2:~# show platform temp
Sensor Temperature High TH Low TH Crit High TH Crit Low TH Warning Timestamp
PSU1_TEMP1 28 N/A N/A N/A N/A False 20220311 08:13:04
PSU2_TEMP1 25 N/A N/A N/A N/A False 20220311 08:13:04
TEMP1 23.5 80.0 N/A N/A N/A False 20220311 08:13:04
TEMP2 27 80.0 N/A N/A N/A False 20220311 08:13:04
TEMP3 24 80.0 N/A N/A N/A False 20220311 08:13:04
TEMP4 27 80.0 N/A N/A N/A False 20220311 08:13:04
TEMP5 24 80.0 N/A N/A N/A False 20220311 08:13:04
Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
* Initial pass of EdgeCore platform changes.
* Remove libevent dependency from lldpd.
* Remove python2 dependencies python3.7 force from platform install script.
* Include usbmount support changes.
* Add missing 4630 install file.
* Update a few file permissions. Add umask line to Makefile. Specify python3.9 in install script.
* Misc platform updates:
- Add missing fan drawer component to sonic_platform
- Remove kernel version specification from Makefile
- Update to 4630 utility
* - Fix file permissions on source files
- Fix compile issue with 4630 driver modules (set_fs, get_fs, no longer supported in kernel 5.10)
* Fix missing/extra parens in 4630 util script.
* Fix indentation in fanutil.py.
* Integrate deltas from Edgecore to ec_platform branch.
* Installer update from Edgecore to resolve smbus serial console errors.
* Update stable_size for warm boot.
* Fix SFP dictionary key to match xcvrd.
* - Add missing define in event.py files needed for xcvrd
- Fix SFP info dict key for 7xxx switches
* 5835 platform file updates including installer and 5835 utility.
* 5835 fix for DMAR errors on serial console.
* Don't skip starting thermalctld in the pmon container.
* Revert several changes that were not related to platform.
* Run thermalctld in pmon container.
* Don't disable thermalctld in the pmon container.
* Fix prints/parens in 7816 install utility.
* - Incorporate 7816 changes from Edgecore
- Fix 7326 driver file using old kernel function
* Update kernel modules to use kernel_read().
* Fix compile errors with 7816 and 7326 driver modules.
* Fix some indents preventing platform files from loading.
* Update 7816 platform sfp dictionary to match field names in xcvrd.
* Add missing service and util files for 7816.
* Update file names, etc. based on full SKU for 7816.
* Delete pddf files not needed. These were causing conflicts with API2.0
implementation.
* Remove pddf files suggested by Edgecore that were preventing API2.0 support from starting.
* Install API2.0 file instead of pddf.
* Update 7326 mac service file to not use pddf. Fix syntax errors in 7326 utility script.
* Fix sonic_platform setup file for 7326.
* Fix syntax errors in python scripts.
* Updates to 7326 platform files.
* Fix some tab errors pulled down from master merge.
* Remove pddf files that were added from previous merge.
* Updates for 5835.
* Fix missing command byte for 5835 psu status.
* Fix permission bits on 4630 service files.
* Update platforms to use new SFP refactoring.
* Fix unused var warnings.
Why I did it
Old fan drv will be build fail under kernel 5.10. It get below error message.
/sonic/platform/broadcom/sonic-platform-modules-accton/as7312-54xs/modules/accton_as7312_54x_fan.c:483:5: error: implicit declarat ion of function 'set_fs'; did you mean 'sget_fc'? [-Werror=implicit-function-declaration]
set_fs(KERNEL_DS);
^~~~~~
sget_fc
How I did it
These code is old design and they are not needed currently. So remove them.
Signed-off-by: Jostar Yang <jostar_yang@accton.com>
Enable pca954x idle_disconnect to avoid possible I2C device address conflict.
How I did it
Change pca954x device_attr idle_state to -2 (MUX_IDLE_DISCONNECT).
How to verify it
Cat pca954x device_attr idle_state and confirm the value is -2.
Signed-off-by: Sean Wu <sean_wu@edge-core.com>
CPLD offset in led drv is incorrect.
#### How to verify it
echo 1 > brightness, show green on in DIAG led
echo 3 > brightness, show red on in DIAG led
echo 4 > brightness, show blue on in DIAG led
echo 5 > brightness, show green blinking in DIAG led
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
Accton util applies lsmod to check if drivers are installed.
But lsmod may return error on startup and skip module installation.
Signed-off-by: Brandon Chuang <brandon_chuang@edge-core.com>
Fix 259 alerts reported by the LGTM tool:
- 245 for Unused import
- 7 for Testing equality to None
- 5 for Duplicate key in dict literal
- 1 for Module is imported more than once
- 1 for Unused local variable
1. undefine led_classdev_register as it is defined in leds.h
2. header file location change
a. linux/i2c/pmbus.h -> linux/pmbus.h
b. linux/i2c-mux-gpio.h -> linux/platform_data/i2c-mux-gpio.h
c. linux/i2c/pca954x.h -> linux/platform_data/pca954x.h
AS7326-56X and AS7726-56X use the same design so both devices have the same problem.
The detailed description below takes AS7326-56X as the example to explain.
Original implementation:
- In platform/broadcom/sonic-platform-modules-accton/as7326-56x/service/as7326-platform-handle_mac.service,
it executes the script file "accton_handle_idt.sh".
- In "accton_handle_idt.sh", it modifies the content of the script file "/etc/init.d/opennsl-modules"
to insert the lines to execute "idt_init.sh" before the command to load broadcom linux kernel module "linux-kernel-bde.ko".
- The script "idt_init.sh" cannot be executed at the first boot of SONiC after installing SONiC under ONIE. This is the reason why all of the ports does not work.
New implementation:
- Let "as7326-platform-handle_mac.service" execute "idt_init.sh".
- Change the content of "as7326-platform-handle_mac.service" to define the service type as "oneshot". Add the settings to ensure "as7326-platform-handle_mac.service" is executed before "opennsl-modules.service".
By setting the service type as "oneshot", it is guaranteed that "opennsl-modules.services" is started only when the forked process to execute the script file "idt_init.sh" is terminated
Signed-off-by: charlie_chen <charlie_chen@edge-core.com>
I2c burst read may failed due to misoperation of ir3570a(A DC-to-DC converter IC).
As #2966, there are 3 more models have this symptom, as7326-56x, as7726-32x, and as9716-32d.
Also correct typo of naming on as7816-64x and as7716-32x.
Signed-off-by: roy_lee roy_lee@accton.com
What I did
Disabling i2c function of ir3570a which may failed i2c tranfer to others.
Close channel of mux after data transfered.
How I did it
Identify version of ir3570, if it's ir3570a, disable its alias i2c address.
Enable parameter of driver i2c_mux_pca954x to close channel on after every access.
How to verify it
Write 08 to offset 0xcf of systom eeprom and execute i2c block read.
It will return error.
plug-in several transceivers and run "show interfaces transceiver presence" and "sfputil show presence". You may see the different result. (But doing this requires updated xcvrd).
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as5712-54x]
Verified with index from 1.
Add qsfp_event() for command "show interaface trancerver".
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as6712-32x]
Add default port speed.
Verified with index from 1.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as7726-32x]
Add default port speed.
Verified with index from 1.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as7712-32x]
Add default port speed.
Verified with index from 1.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as5812-54x]
Add default port speed.
Verified with index from 1.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as5712-54x]
Update port-config with 1-based index.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as5812-54x]
Somehow the service may block, use type=simple to work-around.
Add syslog function for monitor.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as7716-32x]
Update port-config with 1-based index.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as7816-64x]
Update port-config with 1-based index.
Implement sfputil change_event.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as7326-56x]
Update port-config with 1-based index.
Implement sfputil change_event.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Remove debug code.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [as7312-54x]
Update port-config with 1-based index and default port speed.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [security kernel] Upgrade kernel from 4.9.110-3+deb9u2 to 4.9.110-3+deb9u6
short version: 4.9.0-7 to 4.9.0-8
See changelogs for security fixes:
https://tracker.debian.org/media/packages/l/linux/changelog-4.9.110-3deb9u6
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
* Update sonic-linux-kernel submodule after it was merged
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>