Added logrotate file for wtmp and btmp to override default conf and set size cap as 100K as done in
PR: #865. For buster this is control by separate file wtmp and btmp.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
*Removed execute permissions from the systemd copp-config.service file.
Without this we will get a warning: "Configuration file /lib/systemd/system/copp-config.service is marked executable. Please remove executable permission bits. Proceeding anyway."
Why I did it
fstrim has dependency on pmon docker.
How I did it
start fstrim timer after sonic.target.
How to verify it
local test and PR test.
Signed-off-by: Ying Xie ying.xie@microsoft.com
The Lodoga platform also matched crow which was hardcoding the flash
size to 3700. This change enables autodetect on Clearlake which in turns
allows autodetect for Lodoga.
The threshold was bumped from 3700 to 4000 because size computation can
differ slightly and report slightly above 3700.
Lodoga actually has a 8GB storage device.
LodogaSsd variant has a 30GB SSD drive.
However, in boot0 both were mishandled and assigned 4GB for legacy reasons.
Remove the hardcoding of the flash size and let boot0 autodetect the available space.
This commit adds support for changing the default console baud rate configured
within the U-Boot bootloader. That default baud rate is exposed via the value
of the U-Boot 'baudrate' environment variable. This commit removes logic that
hardcoded the console baud rate to 115200 and instead ensures that the U-Boot
'baudrate' variable is always used when constructing the Linux kernel boot
arguments used when booting Sonic.
A change is also made to rc.local to ensure that the specified baud rate is set
correctly in the serial getty service.
*To run VNET route consistency check periodically.
*For any failure, the monit will raise alert based on return code.
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
#### Why I did it
Use a predefined variable to get vendor information when the swss docker container is created
#### How I did it
Use `{{ sonic_asic_platform }}` instead of `$SONIC_CFGGEN -y /etc/sonic/sonic_version.yml -v asic_type`
#### How to verify it
Manually test.
#### Why I did it
Create a target for delayed service timers. Few services in sonic have delayed to speed up the bring up of the system and essential services. However there is no way to track when they start. This will be a problem when executing config reload as config reload expects all services to be up. Hence grouped all the timers that trigger the delayed services under one target so that they could be tracked in 'config reload' command
#### How I did it
Created delay.target service and add created dependency on the delayed targets.
Master/202012 image size grew quite a bit. 3.7G harddrive can no longer hold one image and safely upgrade to another image. Every bit of harddrive space is precious to save now.
Also sh syntax seemingly changed, [ condition ] && action was a legit syntax in 201911 branch but it is an error when condition not met with 202012 or later images. Change the syntax to if statement to avoid the issue.
Signed-off-by: Ying Xie ying.xie@microsoft.com
Fix#7968
Issue is detected on SONiC.20201231.11
In test_static_route.py::test_static_route_ecmp static routes are configured, but neighbors are not resolved after config reload even after 10 minutes.
It looks like the arp_update script is starting to ping when Vlan1000 is not fully configured.
When issue is reproduced, stuck ping6 process is observed in swss container :
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 180 0.1 0.0 6296 1272 pts/0 S 17:03 0:03 ping6 -I Vlan1000 -n -q -i 0 -c 1 -W 0 ff02::1
And when arp_update script successfully resolves neighbors, we observe sleep 300 instead of ping process
#### Why I did it
* `arp_update` fails to ping those neighbors over vlan sub interfaces.
#### How I did it
* modify `arp_update_vars.j2` to get vlan sub interfaces with ipv6 addresses assigned.
* modify `arp_update` to send ipv6 pings over those retrieved vlan sub interfaces.
Signed-off-by: Longxiang Lyu <lolv@microsoft.com>
This is to pick up BRCM SAI 4.3.5.1 which contains the following fix:
CS00012201406: [4.3.3.9] SAI_STATUS_FAILURE on FDB flush after all ports flapped
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on z9332f (TH3) T0 DUT and all passed:
```
ipfwd/test_dir_bcast.py
fib/test_fib.py
```
Manually ran the following test cases on S6100 (TH) and all passed:
```
ipfwd/test_dir_bcast.py
fdb/test_fdb.py
```
This PR creates a directory firmware on the HOST with the path /usr/share/sonic/firmware, as well as this is
mounted on PMON container with the same path /usr/share/sonic/firmware. This is required for firmware
upgrade support for muxcable as currently by design all Y-Cable API's are called by xcvrd. As such if CLI has
to transfer a file to PMON we need to mount a directory from host to PMON just for getting the firmware files.
Hence we require this change.
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
#### Why I did it
Following the discussion in another PR https://github.com/Azure/sonic-buildimage/pull/7708#discussion_r642933510 , since there will be multi subfolders under **/var/log/mellanox**, so we agreed to only mount this folder and the subfolders will be created afterward on demand.
#### How I did it
during the syncd docker creation, only mount folder **/var/log/mellanox**
#### How to verify it
build an Mellanox image and verify the related folder on the host and docker side.
dash doesn't support += operation to append to a variable's value. Use KDUMP_CMDLINE_APPEND="${KDUMP_CMDLINE_APPEND} " instead
The below error message is seen when a reboot is issued.
[ 342.439096] kdump-tools[13655]: /etc/init.d/kdump-tools: 117: /etc/default/kdump-tools: KDUMP_CMDLINE_APPEND+= panic=10 debug hpet=disable pcie_port=compat pci=nommconf sonic_platform=x86_64-accton_as7326_56x-r0: not found
Why I did it
There were two regression issues introduced by BRCM SAI 4.3.3.8:
CS00012196056 [4.3.3.8][WARMBOOT] syncd[2584]: segfault at 5616ad6c3d80 ip 00007f61e0c6bc65 sp 00007fff0c5a7a90 error 4 in libsai.so.1.0[7f61e0a95000+3cd8000]
CS00012195956 [4.3.3.8] [TD3]Syncd Crash at brcm_sai_tnl_mp_create_tunnel()
How I did it
Patch for CS00012195956 from BRCM was validated to have addressed the tunnel creation issue.
Temporary worked around the issue by commenting out a portion of questionable code in BRCM SAI that seems to be the root cause of CS00012196056 .
How to verify it
See the BRCM cases for details.
Why I did it
Support multiple pcie configuration file and change the pcie status table name
This is to match with below two PRs.
Azure/sonic-platform-common#195Azure/sonic-platform-daemons#189
How I did it
Check pcie configuration file with wild card and change the device status table name
How to verify it
Restart with changes and see if the pcie check works as expected.
Why I did it
The SONiC switches get their docker images from local repo, populated during install with container images pre-built into SONiC FW. With the introduction of kubernetes, new docker images available in remote repo could be deployed. This requires dockerd to be able to pull images from remote repo.
Depending on the Switch network domain & config, it may or may not be able to reach the remote repo. In the case where remote repo is unreachable, we could potentially make Kubernetes server to also act as http-proxy.
How I did it
When admin explicitly enables, the kubernetes-server could be configured as docker-proxy. But any update to docker-proxy has to be via service-conf file environment variable, implying a "service restart docker" is required. But restart of dockerd is vey expensive, as it would restarts all dockers, including database docker.
To avoid dockerd restart, pre-configure an http_proxy using an unused IP. When k8s server is enabled to act as http-proxy, an IP table entry would be created to direct all traffic to the configured-unused-proxy-ip to the kubernetes-master IP. This way any update to Kubernetes master config would be just manipulating IPTables, which will be transparent to all modules, until dockerd needs to download from remote repo.
How to verify it
Configure a switch such that image repo is unreachable
Pre-configure dockerd with http_proxy.conf using an unused IP (e.g. 172.16.1.1)
Update ctrmgrd.service to invoke ctrmgrd.py with "-p" option.
Configure a k8s server, and deploy an image for feature with set_owner="kube"
Check if switch could successfully download the image or not.
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
Currently we leveraged the Supervisor to monitor the running status of critical processes in each container and it is more reliable and flexible than doing the monitoring by Monit. So we removed the functionality of monitoring the critical processes by Monit.
How I did it
I removed the script process_checker and corresponding Monit configuration entries of critical processes.
How to verify it
I verified this on the device str-7260cx3-acs-1.
Why I did it
In upgrade scenarios, where config_db.json is not carry forwarded to new image, it could be left w/o TACACS credentials.
Added a service to trigger 5 minutes after boot and restore TACACS, if /etc/sonic/old_config/tacacs.json is present.
How I did it
By adding a service, that would fire 5 mins after boot.
This service apply tacacs if available.
How to verify it
Upgrade and watch status of tacacs.timer & tacacs.service
You may create /etc/sonic/old_config/tacacs.json, with updated credentials
(before 5mins after boot) and see that appears in config & persisted too.
Which release branch to backport (provide reason below if selected)
201911
202006
202012
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
This PR aims to monitor the memory usage of streaming telemetry container and restart streaming telemetry container if memory usage is larger than the pre-defined threshold.
How I did it
I borrowed the system tool Monit to run a script memory_checker which will periodically check the memory usage of streaming telemetry container. If the memory usage of telemetry container is larger than the pre-defined threshold for 10 times during 20 cycles, then an alerting message will be written into syslog and at the same time Monit will run the script restart_service to restart the streaming telemetry container.
How to verify it
I verified this implementation on device str-7260cx3-acs-1.
Why I did it
Currently, there is a bug in the ntp.conf jinja2 template where it will ignore the src_intf directive in CONFIG_DB if there are multiple IP addresses associated with an interface. This code change fixes that bug and allows the template to select the correct source interface for NTP.
How I did it
I did this by modifying the macro in ntp.conf.j2 which determines if there is an ip address associated with an interface to set a state variable when it detects a valid interface entry in CONFIG_DB instead of outputting "true" directly (which could result in multiple "trues" outputted for interfaces with multiple valid IP addresses).
How to verify it
Add two ipv4 addresses to an interface in SONiC
Add the following configuration to config_db.json
{
"NTP": {
"global": {
"src_intf": "Ethernet1"
}
}
}
Replace Ethernet1 with the interface name of the one you assigned the IP addresses to.
Run sudo config reload -y
Open /etc/ntp.conf and verify that the following line exists
...
interface listen Ethernet1
...
The interface specified should be the one set in the previous steps.
Description for the changelog
[ntp] Fix ntp.conf template to allow setting of source port in CONFIG_DB
Why I did it
This SAI change is to Enable TD2 platforms to also be able to handle VFP-based sub-interfaces.
This is the feature that is also needed for TD2 platforms.
How to verify it
Guohan and Team has validated this feature change on TD2 platforms
#### Why I did it
If a process limits using nodes by mempolicy/cpusets, and those nodes become memory exhaustion status, one process may be killed by oom-killer.
No panic occurs in this case, because other node's memory may be free.
This means system total status may be not fatal yet.
#### How I did it
Remove 'vm.panic_on_oom=1' kernel flag from 'vmcore-sysctl.conf '
Map priority 0 to TC 1 and priority 1 to TC 0
Send traffic on priority 0 and 1 and verified that it gets mapped correctly in hw
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
start pcie-check.service after config-setup.service since pcie_util depends on device_info which is available with config db metadata.
How I did it
Add config-setup.service as a dependency of pcie-check.service
How to verify it
Upon reboot, check if the pcie-check.sh throws the platform api error which is dependent on DEVICE_METADATA
This is to pick up BRCM SAI 4.3.3.5-2 which contains 2 main changes:
1. hsdk-6.5.21-p1.patch (to address some field problems related to SDK issue.
2. Fix for CS00012097141 (remove some unnecessary debug setting that was causing non functional impacting problem at boot time)
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on S6100 DUT and all passed:
```
ipfwd/test_dir_bcast.py
fib/test_fib.py
vxlan/test_vxlan_decap.py
decap/test_decap.py
fdb/test_fdb.py
```
202012 branch is using reproducible build. The versions-py3 file must contains correct pip3 package version. Otherwise we will get a build error
```
Step 31/74 : RUN pip3 install scapy==2.4.4 pyroute2==0.5.14 netifaces==0.10.9
---> Running in d7a2401dd21d
Collecting scapy==2.4.4
Downloading scapy-2.4.4.tar.gz (1.0 MB)
Collecting pyroute2==0.5.14
Downloading pyroute2-0.5.14.tar.gz (873 kB)
ERROR: Cannot install netifaces==0.10.9 because these package versions have conflicting dependencies.
The conflict is caused by:
The user requested netifaces==0.10.9
The user requested (constraint) netifaces==0.10.7
To fix this you could try to:
1. loosen the range of package versions you've specified
2. remove package versions to allow pip attempt to solve the dependency conflict
ERROR: ResolutionImpossible: for help visit https://pip.pypa.io/en/latest/user_guide/#fixing-conflicting-dependencies
The command '/bin/sh -c pip3 install scapy==2.4.4 pyroute2==0.5.14 netifaces==0.10.9' returned a non-zero code: 1
[ FAIL LOG END ] [ target/docker-sonic-vs.gz ]
```
Why I did it
Finding running containers through "docker ps" breaks when kubernetes deploys container, as the names are mangled.
How I did it
The data is is available from FEATURE table, which takes care of kubernetes deployment too.
How to verify it
Deploy a feature via kubernetes and don't expect error from container_check.
- Support compile sonic arm image on arm server. If arm image compiling is executed on arm server instead of using qemu mode on x86 server, compile time can be saved significantly.
- Add kernel argument systemd.unified_cgroup_hierarchy=0 for upgrade systemd to version 247, according to #7228
- rename multiarch docker to sonic-slave-${distro}-march-${arch}
Co-authored-by: Xianghong Gu <xgu@centecnetworks.com>
Co-authored-by: Shi Lei <shil@centecnetworks.com>
Why I did it
Recent systemd upgrade from #7228 requires an extra cmdline parameter for dockerd to start properly.
Updating boot0 was missed as part of the systemd upgrade change.
How I did it
Just added the missing cmdline parameter in files/Aboot/boot0.j2
This change fixes#7372
How to verify it
Boot the image and dockerd should start normally.
Fix#7364
99-default.link - was always in SONiC, but previous systemd (<247) had an issue and it did not work due to issue systemd/systemd#3374. Now systemd 247 works.
However, such policy overrides teamd provided mac address which causes teamd netdev to use a random mac
address. Therefore, needs to be disabled.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Why I did it
Support readonly version of the command vtysh
How I did it
Check if the command starting with "show", and verify only contains single command in script.
Encounter error during "config-setup boot" if the updategraph is enabled.
How I did it
Correct the code inside the config-setup script.
Remove the space between the assignment operator.
How to verify it
Remove the /etc/sonic/config_db.json and reboot the device.
Originally, it will return following error after boot up.
rv: command not found
After modification, it can correctly parse the status of updategraph without error.
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
Since we introduced a new value always_disabled for the state field in FEATURE table, the expected running container list
should exclude the always_diabled containers. This bug was found by nightly test and posted at here: issue. This PR fixes#7210.
How I did it
I added a logic condition to decide whether the value of state field of a container was always_disabled or not.
How to verify it
I verified this on the device str-dx010-acs-1.
Which release branch to backport (provide reason below if selected)
201811
201911
202006
[ x] 202012
Features may be enabled/disabled for the same topology based on run-time
configuration. This PR adds the ability to enable/disable feature based
on config db data.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
show ip interfaces is enhanced recently to support multi ASIC platforms in this PR- https://github.com/Azure/sonic-utilities/pull/1396 .
The ipintutil script as to run as sudo user, to get the ip interface from each namespace.
Add this script to the sudoer file so that show ip interface command is available for user with read-only permissions
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>