#### Why I did it
Include sonic-bgp-monitor to setup.py so it gets included in /usr/local/yang-models when installing the package
#### How I did it
#### How to verify it
install the package
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
#### Description for the changelog
<!--
Write a short (one line) summary that describes the changes in this
pull request for inclusion in the changelog:
-->
#### A picture of a cute animal (not mandatory but encouraged)
Enable dbgsym package for dhcpmon.
Allow CFLAGS and LDFLAGS from environment variables to be used
in the dhcp6relay build. This makes sure that the -O2 flag from
dpkg-buildflags gets used.
Finally, enable all hardening flags in dpkg-buildflags for
dhcp6relay and dhcpmon. The change from the default set of flags is that
during linking, immediate binding of symbols is done instead of lazy
binding.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
#### How I did it
Added mclag sonic yang file for the MCLAG enhancements as per HLD: Azure/SONiC#596
#### How to verify it
try rest APIs
#### Description for the changelog
Added mclag sonic yang
- Why I did it
For SYSTEM READY feature. Currently, there is a booting stage in system health service to indicate that the system is loading SONiC component. This booting stage is no longer needed because SYSTEM READY feature will treat that stage as system "NOT READY".
- How I did it
1. Remove booting stage
2. Adjust unit test cases
- How to verify it
Manual test, Unit test, sonic-mgmt Regression
- Why I did it
Fix issue: 'sx_port_mapping_t' object has no attribute 'slot_id'. sx_port_mapping_t only has attribute slot.
- How I did it
Change slot_id to slot.
- How to verify it
Manual test
- Why I did it
Python select.select accept a optional timeout value in seconds, however, the value passes to it is a value in millisecond.
- How I did it
Transfer the value to millisecond.
- How to verify it
Manual test
Why I did it
the strcpy and buffer allocation is not safe, it corrupts 1 byte on the stack. Depending on the memory layout, it may or may not cause issue immediately.
message type is not validated before updating the counter. Which could cause segment fault.
How I did it
Remove the unsafe strcpy, use config->interface.c_str() instead.
Check message type before updating counters.
How to verify it
The issue (1) caused segment fault on a specific platform. The fix was validated there. Issue (2) was precautionary. Added log in case it triggers.
- Why I did it
To include latest SDK fixes:
1. On CMIS modules, after low power configuration, the firmware waited for the module state to be ModuleReady instead of ModuleLowPower causing delays.
2. When connecting SN4600C, 100GbE port with CWDM4 module (Gen 3.0), link up time is 30 seconds.
and to include SAI fixes \ changes:
1. Reduce verbosity for resource check vendor data not found
2. Fix metadata validation, check default value on conditions check
3. Add 100MB, 10MB to 2201 system
4. L3 VXLAN overlay ECMP
5. VXLAN srcport API implementation
6. Fix scheduler profile null (default values) when set on sub group scheduler group
7. Fix ACL binding restoration when port leaves a LAG
8. Fix route logic for set next hop/action and reference counter for ECMP overlay
- How I did it
1. Updated SDK/FW submodule and relevant makefiles with the required versions.
2. Update SAI submodule and relevant makefile with the required version.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Why I did it
Minigraph parser added a new field 'cluster' to device_metadata, and then yang validation is blocked.
How I did it
Add 'cluster' to device_metadata yang models.
How to verify it
Run UT for sonc-yang-models.
Use minigraph parser to generate ConfigDB schema and run yang validation.
Signed-off-by: Gang Lv ganglv@microsoft.com
* [y_cable] Support for initialization of new Daemon ycable to support
ycables
This PR also adds the commit in sonic-platform-daemons
94fa239 [y_cable] refactor y_cable to a seperate logic and new daemon from xcvrd (#219)
Why I did it
This PR separates the logic of Y-Cable from xcvrd. Before this change we were utilizing xcvrd daemon to control all aspects of Y-Cable right from initialization to processing requests from other entities like orch,linkmgr.
Now we would have another daemon ycabled which will serve this purpose.
Logically everything still remains the same from the perspective of other daemons.
it also take care aspects like init/delete daemon from Y-Cable perspective.
How I did it
To serve the purpose we build a new wheel sonic_ycabled-1.0-py3-none-any.whl and install it inside pmon.
We also initalize the daemon ycabled which serves our purpose for refactor inside pmon
How to verify it
Ran the changes with an image for dualtor tests on a 7050cx3 platform
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
Why I did it
Add TSA/B/C dualtor support
Signed-off-by: Longxiang Lyu lolv@microsoft.com
How I did it
For TSA, toggle all the mux to standby if the device type is dualtor and there are active mux ports.
For TSC, add mux status output.
How to verify it
Run TSA/B/C on a dualtor setup
Why I did it
Requirements from Microsoft for fwutil update all state that all firmwares which support this upgrade flow must support upgrade within a single boot cycle. This conflicted with a number of Mellanox upgrade flows which have been revised to safely meet this requirement.
How I did it
Added --no-power-cycle flags to SSD and ONIE firmware scripts
Modified Platform API to call firmware upgrade flows with this new flag during fwutil update all
Added a script to our reboot plugin to handle installing firmwares in the correct order with prior to reboot
How to verify it
Populate platform_components.json with firmware for CPLD / BIOS / ONIE / SSD
Execute fwutil update all fw --boot cold
CPLD will burn / ONIE and BIOS images will stage / SSD will schedule for reboot
Reboot the switch
SSD will install / CPLD will refresh / switch will power cycle into ONIE
ONIE installer will upgrade ONIE and BIOS / switch will reboot back into SONiC
In SONiC run fwutil show status to check that all firmware upgrades were successful
Why I did it
Old fan drv will be build fail under kernel 5.10. It get below error message.
/sonic/platform/broadcom/sonic-platform-modules-accton/as7312-54xs/modules/accton_as7312_54x_fan.c:483:5: error: implicit declarat ion of function 'set_fs'; did you mean 'sget_fc'? [-Werror=implicit-function-declaration]
set_fs(KERNEL_DS);
^~~~~~
sget_fc
How I did it
These code is old design and they are not needed currently. So remove them.
Signed-off-by: Jostar Yang <jostar_yang@accton.com>
Update the sonic-swss submodule. The following are new commits in the submodule:
6cb43ee [p4orch] Fix handlePortStatusChangeNotification status deserialize (#2111)
863f0f1 [azp]: Enable PR diff coverage (#2083)
bf4cd4a Fix the unsafe usage of strncpy in portsorch.cpp (#2110)
c1b4b40 support port isolation group in BFN platform (#1940)
Signed-off-by: Andriy Kokhan <andriyx.kokhan@intel.com>
#### Why I did it
src\tacacs\bash_tacplus\debian\rules file mode is 644, and debian build will change it to 755, which will cause image version contains 'dirty'
#### How I did it
Change src\tacacs\bash_tacplus\debian\rules file mode to 755
#### How to verify it
Check the image version not contains dirty
#### Which release branch to backport (provide reason below if selected)
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [*] 202111
#### Description for the changelog
Change src\tacacs\bash_tacplus\debian\rules file mode to 755
#### A picture of a cute animal (not mandatory but encouraged)
Why I did it
Update Broadcom SAI to version 6.0.0.13, SDK 6.5.24, saibcm-modules to 6.5.24.gpl
How I did it
Brcm SAI 6.0 EA with fixes for CS00012203367, CS00012219613, CS00012213974, CS00012218290, CS00012217169, CS00012211718, CS00012213944, CS00012215529, CS00012218100, CS00012214196, CS00012212681, CS00012205138, CS00012208537, CS00012185316, CS00012208524, CS00012203367, CS00012197364.
Why I did it
sonic-broadcom-dnx.bin should be able to installed on DNX supported platform, whereas it doesn't.
How I did it
Changed CONFIGUTED_PLATFORM to TARGET_MACHINE to distinguish broadcom and broadcom-dnx
How to verify it
tar sonic-broadcom-dnx.bin and verify its platforms_asic contians dnx platforms
Also verify on image with other asic, no regression.
Why I did it
ACL have ACCEPT action indeed, but yang doesn't support it.
How I did it
Add 'ACCEPT' enum to sonic-types.yang.j2
How to verify it
Run the YANG model unit tests
Why I did it
Eliminate benign firsttime boot error reported when running on platforms that do not support kdump.
How I did it
Change rc.local to check for presence of the file /etc/default/kdump-tools before referencing it.
How to verify it
Install a new image on an armhf or arm64 platform and check for a failed reference to /etc/default/kdump-tools on firsttime boot.
- External PHY is managed via gearbox (gbsybcd docker container) in SONiC
- Enhanced 'External PHY management' from SONiC's single-ASIC environment to multi-ASIC
- Enhanced gbsyncd docker container from single Namespace to multi-Namspace mode
- Added gbsyncd.service.j2 on per_namespace basis.
- Each namepace/ASIC now to have its unique gbsyncd<ASIC#> docker container with its
own Gearbox table, redis-DB
Signed-off-by: Shyam Kumar <shyakuma@cisco.com>
Why I did it
ConfigDB schema generated by minigraph parser can't pass yang validation.
How I did it
Modify minigraph.py, and use 'state' to replace 'status'.
How to verify it
Run UT for sonic-config-engine.
Use minigraph parser to generate ConfigDB schema, and run yang validation.
Signed-off-by: Gang Lv ganglv@microsoft.com
Why I did it
end2end test is blocked by Yang model for BGP monitor.
How I did it
Create new yang files for BGP monitor, and add UT.
How to verify it
Follow the steps in #9711.
Run UT for sonic-yang-models.
Signed-off-by: Gang Lv ganglv@microsoft.com
Why I did it
Need to be able to run smartctl when pmon docker is not running.
How I did it
Removed the pmon dependency for pmon as well as the command wrapper and added it to the debian-extension.
How to verify it
Stop pmon
Run smartctl from the host and verify it runs without error
c4127c2 [psud] Fix PSU log issue (#235)
07542cb [pmon][xcvrd]xcvrd process show backtrace on the internal port. (#233)
3e432e7 [Y-Cable] Increased unit test coverage of y_cable_helper.py (#229)
7c363f5 [ledd] prevent led crash on recirc port event (#232)
e9ccd82 [sonic-platform-daemons] fix dependency issue on py2 wheels by correcting the path (#234)
2b0acfb [sfp-refactoring] xcvrd: add initial support for CMIS application initialization (#217)
- Why I did it
Optimize thermal control policies to simplify the logic and add more protection code in policies to make sure it works even if kernel algorithm does not work.
- How I did it
Reduce unused thermal policies
Add timely ASIC temperature check in thermal policy to make sure ASIC temperature and fan speed is coordinated
Minimum allowed fan speed now is calculated by max of the expected fan speed among all policies
Move some logic from fan.py to thermal.py to make it more readable
- How to verify it
1. Manual test
2. Regression
Tested on a Celestica Seastone2 DX030 switch
Testing scenarios:
- Various QSFP ports in both normal and breakout config.
- 100G and 40G link speed show different colors.
- SFP1 port works.
Signed-off-by: Christian Svensson <blue@cmd.nu>
- Why I did it
For MSN4410/MSN4600/MSN4700 now they can support fetching PSU voltage threshold, no need to skip the psu voltage check in system health monitoring, so update the system health monitoring configuration file for these platforms.
- How I did it
remove skip PSU change config from the system_health_monitoring_config.json file
- How to verify it
Build image run on these platforms, system health monitoring will not report error against PSU voltage
Signed-off-by: Kebo Liu <kebol@nvidia.com>
```
d9f3afe [fdbshow] Adding more options for fdbshow and show mac (#1982)
902e14f Revert "Revert "[Barefoot] Added CLI to list/set P4 profile (#1951)"" (#2019)
5cc9dd5 Revert "Revert "[sonic-package-manager] support sonic-cli-gen and packages with YANG model (#1650)" (#1972)" (#1994)
```
As part of this, update the isc-dhcp package to match the Bullseye
version (this fixes some compile errors related to BIND), clean up some
of the build dependencies and runtime dependencies for debian packaging,
and use the default Boost version to compile against instead of
explicitly saying using 1.74.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
- Why I did it
MSN4700 platform has 8 lanes per port and thus can support 2x40G with each lane running at 10G
- How I did it
Added 40G to 2x200G breakout mode in platform.json
- How to verify it
Run config int break Ethernet0 2x40G[200G,100G,50G,25G,10G,1G]
And verify the command runs successfully and the port speed was set to 40G with a 2x breakout.
* Description: Currently IPv4 routes with IPv6 link local next hops are
not properly installed in FPM.
Reason is the netlink decoding truncates the ipv6 LL address to 4 byte
ipv4 address.
Ex : fe80:: is directly converted to ipv4 and it results in 254.128.0.0
as next hop for below routes
show ip route
Codes: K - kernel route, C - connected, S - static, R - RIP,
O - OSPF, I - IS-IS, B - BGP, E - EIGRP, N - NHRP,
T - Table, v - VNC, V - VNC-Direct, A - Babel, D - SHARP,
F - PBR, f - OpenFabric,
> - selected route, * - FIB route, q - queued, r - rejected, b - backup
B>* 2.1.0.0/16 [200/0] via fe80::268a:7ff:fed0:d40, Ethernet0, weight 1,
02:22:26
B>* 5.1.0.0/16 [200/0] via fe80::268a:7ff:fed0:d40, Ethernet0, weight 1,
02:22:26
B>* 10.1.0.2/32 [200/0] via fe80::268a:7ff:fed0:d40, Ethernet0, weight
1, 02:22:26
Hence this fix converts the ipv6-LL address to ipv4-LL (169.254.0.1)
address before sending it to FPM. This is inline with how these types of
routes are currently programmed into kernel.
Signed-off-by: Nikhil Kelapure <nikhil.kelapure@broadcom.com>
[image]: Prevent radius passkey and snmp community string into syslog. (#9727)
#### Why I did it
Prevent radius passkey and snmp community string into syslog.
#### How I did it
Add radius and snmp config command to PASSWD_CMDS
#### How to verify it
Run and pass all UTs.
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
#### Description for the changelog
Add radius and snmp config command to PASSWD_CMDS to prevent radius passkey and snmp community string into syslog.
#### A picture of a cute animal (not mandatory but encouraged)
#### Why I did it
Build failed.
Due to the error message looks like build failed because `pyversions` utility was not found.
`pyversions` utility is a part of `python2-minimal` package and it wasn't installed.
#### How I did it
To avoid installing python2 just specify explicit python version `--with python3` and use build system for py3 `--buildsystem=pybuild`
#### How to verify it
Run build