What I did it
Add new platform x86_64-ragile_ra-b6910-64c-r0 (Tomahawk 3)
ASIC Vendor: Broadcom
Switch ASIC: Tomahawk 3
Port Config: 64x100G
-How I did it
Provide device and platform related files.
-How to verify it
show platform fan
show platform ssdhealth
show platform psustatus
show platform summary
show platform syseeprom
show platform temperature
show interface status
Why I did it
Power cycle test case fails for Z9332f in sonic-mgmt framework(#8605).
How I did it
Modified the platform API to return expected strings.
How to verify it
Power cycle the device and verify the reboot reason.
Run sonic-mgmt test_reboot script.
Catch up on fixes from BRCM SUG repo to pick up fixes after 5.0.0.6 all the way up to 5.0.0.8
Fixes include the following:
```
CS00012201827: Warmreboot causes syncd crash with SAI_API_UNSPECIFIED:syncdb_data_file_read:2230 Failed to parse JSON: error -2
DNX: Fix for ACL table create with v6 next hdr attr
and many unspecified changes that also went into 5.0.0.8
```
#### How to verify it
Preliminary tests looks fine on both XGS (gechiang) and DNX (judyjoseph)
On XGS testing done as following:
BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on 7260CX3 T0 DUT and all passed:
```
ipfwd/test_dir_bcast.py
fdb/test_fdb.py
fib/test_fib.py
vlan/test_valn.py
```
Also validated for for CS00012201827 (https://github.com/Azure/sonic-buildimage/issues/8300)
To enable saiserver docker on different platforms, it needs different configuration files. make the saiserver docker mount them in hwsku folder.
Co-authored-by: Ubuntu <richardyu@richardyu-ubuntu-vm0.trsxrdzozv2e1czsze2t05vqzh.ix.internal.cloudapp.net>
- Disable health monitoring of `psu.voltage` until support is implemented
- chassis: disable provisioning bit once linecard has booted
- chassis: fix issue in `show version` when running as `admin`
- chassis: fix race when reading an eeprom before it's available
- chassis: implement `get_all_asics` call
- api: fix `ChassisBase.get_system_eeprom_info` implementation
- api: add missing thermal condition and info
- api: fix return value of `ChassisBase.set_status_led`
- sfp: introduce SfpOptoeBase implementation used based on configuration knob
- psu: rely on pmbus to read input/output status when other mechanism is missing
- misc: other refactors and improvements
Why I did it
To monitor the SSD health condition in DellEMC S6100 platform post upgrade.
A daemon is introduced to monitor the SSD every one hour.
To check for SSD status at boot time and at the time of cold-reboot.
All these changes are supported only for newer SSD firmware.
Porting changes from 201911 branch
Added a platform_reboot_pre_check script to prevent cold-reboot based on SSD status.
Depends on Azure/sonic-utilities#1556
DO NOT MERGE UNTIL ABOVE PR IS MERGED
CPLD offset in led drv is incorrect.
#### How to verify it
echo 1 > brightness, show green on in DIAG led
echo 3 > brightness, show red on in DIAG led
echo 4 > brightness, show blue on in DIAG led
echo 5 > brightness, show green blinking in DIAG led
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
The start template script that this value is used in will determine what
network namespace to use, and will add --net=host if it needs to run in
the host namespace.
With Docker 20.10, if --net=host is specified twice in docker run, then
it errors out. Therefore, remove the explicit --net=host in the run
options setting and let the start template script specify it.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
fix the dx010 system eeprom unavailable issue
How I did it
enable the i2c slave 30ms timeout mechanism
How to verify it
i2cstress test in DX010 iSMT controller bus
Co-authored-by: nicwu-cel <nicwu@celestica.com>
Co-authored-by: Arun LK <Arun_L_K@dell.com>
Why I did it
Support for show system-health command in s5232f
How I did it
Added the configuration, API changes to support system health
How to verify it
Execute "show system-health summary/detail/monitor-list" CLI.
Why I did it
platform test suite failed for few API's in DellEMC Z9332f platform.
How I did it
Modified the API's to return the expected values in the script.
How to verify it
Run platform test suite after making the changes.
This change is to add a gbsyncd container to accommodate the syncd process and the SAI libraries for the Credo gearbox chips.
How I did it
This container works similar to the existing Broadcom syncd container. Its main difference is that the SAI-related dynamic libraries are replaced by the ones for Credo gearbox chips, and the container only reacts to SAI events for the gearbox chips. The SAI libraries will be provided by the package libsai-credo_1.0_amd64.deb.
For the image build, the added container will be built and included in the Broadcom platform image, after $(LIBSAI_CREDO)_URL = is replaced to the correct value. For now, as $(LIBSAI_CREDO)_URL is empty, the container build is skipped in the image build.
After the container is included in the image, in the runtime, the container will begin with checking the existence of /usr/share/sonic/hwsku/gearbox_config.json; if that file is not provided, the container will exit by itself. Therefore, for platforms unrelated to the Credo chips, as long as they are not providing the file, they will not be affected by this change.
Why I did it
Added a check in determining CPU reset in fast-/warm-reboot in their respective platform plugin.
Introducing reboot plugin for "reboot" command to handle its own platform plugin.
How I did it
On branch s6100_fast_warm_check
Changes to be committed:
(use "git reset HEAD ..." to unstage)
modified: ../../debian/platform-modules-s6100.install
modified: ../scripts/fast-reboot_plugin
modified: ../scripts/platform_reboot_override
new file: ../scripts/reboot_plugin
modified: ../scripts/track_reboot_reason.sh
modified: chassis.py
How to verify it
Triggered cold-reset inside fast-reboot to test out the reboot-cause 2.0 API.
Why I did it
serial-getty service exited in Dell S6100 device randomly.
How I did it
Added serial-getty to monit services.
How to verify it
Stop serial-getty in ssh session and check whether the service restarts or not.
- Improve chassis linecard restartability
- Fix 'show system-health' cli by adding non standard api
- Fix ledd crash on linecards with Recycle/Inband ports
- Refactor DPM management and add ADM1266 support
- Add state machine to update DPM RTC clock periodically
- Improve xcvr temperature reporting
- Fix lane mapping and `default_sku` for `x86_64-arista_7170_32c` platform
- Fix `7170-32C/CD` platform definition
Add needed code to pddf_custom_psu.c to deal with multi PSU and get SN.
How to verify it
Plugin new PSU (3Y) and test,
```
root@sonic:/sys/bus/i2c/drivers/psu/9-0050# cat psu_serial_num
S0A000X601919000013
root@sonic:/sys/bus/i2c/drivers/psu/9-0050# cat psu_model_name
YESM1300AM
root@sonic:/home/admin# pddf_psuutil mfrinfo
PSU Status Manufacturer ID Model Serial Fan Airflow Direction
PSU1 NOT OK 3Y POWER YESM1300AM S0A000X601919000007 exhaust
PSU2 OK 3Y POWER YESM1300AM S0A000X601919000013 exhaust
```
Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
Move SAI libraries for Broadcom for XGS and DNX families to 5.0.0.6
Included fixes
```
CS00012195263 | [4.3][5.0][TD3] Packets with broken IP headers received on VLAN interface are not dropped
CS00012192505 | [4.3] Re-encap IPinIP decap packets
CS00012192502 | [3.7.5.2] Start LED shell script execution on all DELL based platforms causing all ports flapping on SAI 3.7.5.2
CS00012191363 | [4.3] Support of memscan thread to detect TCAM parity error
CS00012190932 | [4.3] SAI_PORT_PFC_X_RX_PKTS incremented incorrectly even when no PFC frames are received on that priority
CS00012183901 | [4.3][WARMBOOT] WARMReboot with active traffic causes port flap reported during warm reboot
CS00011382163 | [4.4] Support warm-boot from 3.5 to 4.3
CS00011318937 | [4.3] MACSec SAI Support for Jericho2c+
CS00011318926 | [4.3] Provide SAI support for Jericho2c+
CS00012195263 | [4.3][5.0][TD3] Packets with broken IP headers received on VLAN interface are not dropped
CS00012195261 | [4.3][5.0][TD3]VLAN tagged IP packet received on untagged interface being routed instead of dropped
CS00012183901 | [4.3][WARMBOOT] WARMReboot with active traffic causes port flap reported during warm reboot
CS00012196056 | [4.3.3.8][WARMBOOT] syncd[2584]: segfault at 5616ad6c3d80 ip 00007f61e0c6bc65 sp 00007fff0c5a7a90 error 4 in libsai.so.1.0[7f61e0a95000+3cd8000]
CS00012195262 | [4.3][5.0][TD3] Malformed IP packet(missing IP header) received on a VLAN Interface is flooded to other LVAN members instead of being dropped
CS00012195956 | [4.3.3.8] [TD3]Syncd Crash at brcm_sai_tnl_mp_create_tunnel()
PR 4346163: Add support for AN/LT
```
- Why I did it
To fix failed test cases of Haliburton platform APIs that found on platform_tests script
- How I did it
Add device/celestica/x86_64-cel_e1031-r0/platform.json
Update functions to support python3.7
Add more functions follow latest sonic_platform_base
Fix the bug
- How to verify it
Run platform_tests script
Signed-off-by: Wirut Getbamrung [wgetbumr@celestica.com]
Why I did it
Update XGS and DNX SAI to 5.0.0.4 and additional flags needed in saibcm-modules
The following CSP's are merged in 5.0.0.4
CS00012182148 [4.3] Rate Limit Parity error message to syncd/sonic.
CS00012178692 [4.3] ACL drops counted as interface drops
CS00012183901 [4.3][WARMBOOT] WARMReboot with active traffic causes port flap reported during warm reboot
CS00012070713 [SAI 4.3 , DNX, 8690] Everflow ACL creation fails - brcm_sai_dnx_create_acl_table API fails, with unknown attribute error.
CS00012023263 [4.4] TD3/TH2 : Support 4 lossless queues(2 SW PFCWD and 2 HW PFCWD)
CS00012019578 [4.4] Pre FEC bit-error rate (BER) - DNX and XGS (TD and TH 50/100G)
How I did it
Changes the various make files to include the new SAI release + update the opennsl-modules.
Why I did it
We hit an issue recently in the chassis bringup where the linux bde attach failed with the following ioctl error.
[ 9058.585960] linux-user-bde (897363): Error: Invalid ioctl (00004c1d)
[ 9105.668237] linux-user-bde (901002): Error: Invalid ioctl (00004c1d)
Debugged with Broadcom team, who suggested to use this flag BCM_INSTANCE_SUPPORT to support multi-instance scenarios ( platforms with more than one asic where there are separate sai/syncd docker instances running controller each asic instance).
This flag was introduced since SDK-6.5.21 and need to be present in SAI and SAI GPL kernel module makefile.
How I did it
Add the flag in this flag BCM_INSTANCE_SUPPORT in gpl modules
Why I did it
To determine the revision of the pcie.yaml to be used based on BIOS version in DellEMC S6100 platform.
Depends on: Azure/sonic-platform-common#195
How I did it
Added two revisions of pcie.yaml pcie_1.yaml and pcie_2.yaml
Included a platform-specific Pcie class to provide the revision of the pcie.yaml to be used by pcieutil/pcied.
How to verify it
Execute pcieutil check (Azure/sonic-utilities#1672) command and verify the list of PCIe devices displayed.
Logs: UT_logs.txt
#### Why I did it
Support API 2.0 for S5248F platform
#### How I did it
Making changes to S5248F platform specific directory
Co-authored-by: Arun LK <Arun_L_K@dell.com>
#### Why I did it
The debian install files are required for installing sonic_platform packages
#### How I did it
Add install files to under debian folder
Co-authored-by: robert.hong <robert.hong@qct.io>
#### Why I did it
- To build flashrom properly with dependency tracking.
#### How I did it
- Moved flashrom code from platform/broadcom/sonic-platform-modules-dell/tools directory to src/flashrom directory.
- At the end, flashrom_0.9.7_amd64.deb package is build which will be installed in the devices.
- Currently flashrom builds only for Dell S6100 platforms.
Introduce new sonic-buildimage images for Broadcom DNX ASIC family.
sonic-broadcom-dnx.bin
sonic-aboot-broadcom-dnx.swi
How I did it
NO CHANGE to existing make commands
make init; make configure PLATFORM=broadcom; make target/sonic-aboot-broadcom.swi; make target/sonic-broadcom.bin
The difference now is that it will result in new broadcom images for DNX asic family as well.
sonic-broadcom.bin, sonic-broadcom-dnx.bin
sonic-aboot-broadcom.swi, sonic-aboot-broadcom-dnx.swi
Note: This PR also adds support for Broadcom SAI 5.0 (based on 1.8 SAI ) for DNX based platform + changes in platform x86_64-arista_7280cr3_32p4 bcm config files and platform_env.conf files
Add device and platform code for ix7-bwde, ix8a-bwde.
Support platform API 2.0 for all quanta platforms except for ix1b
Co-authored-by: robert.hong <robert.hong@qct.io>
Added support BRCM SAI 5.0.0.1.
Major changes here:
CS00012019568 Link Training (all 100G ASICs - TH families and TD3)
CS00012184310 [attribute_capability| for port SAI_PORT_ATTR_TPID returns CREATE_IMP=false|SET_IMP=true|GET_IMP=true
CS00012182145 [IPinIP][Tunnel Delete] If IPinIP tunnel delete is performed observed following SYNCd error: ERR syncd#syncd: [none] SAI_API_TUNNEL:brcm_sai_tnl_mp_remove_tunnel_term_table_entry:4026 _brcm_sai_mptnl_sip_tnl_lookup failed with error -7.
CS00012182148 Rate Limit Parity error message to syncd/sonic.
CS00012178692 ACL drops counted as interface drops
CS00012183901 [WARMBOOT] WARMReboot with active traffic causes port flap reported during warm reboot
CS00012023263 TD3/TH2 : Support 4 lossless queues(2 SW PFCWD and 2 HW PFCWD)
CS00012019578 Pre FEC bit-error rate (BER) - DNX and XGS (TD and TH 50/100G)
#### Why I did it
- After [sonic-linux-kernel#177](https://github.com/Azure/sonic-linux-kernel/pull/177) changes, the I2C mux channels of Baseboard and Switchboard CPLDs are moved from i2c-4 and i2c-5 to i2c-36 and i2c-37 respectively.
- This caused QSFP driver initialization of i2c-36 to i2c-41 to fail causing the ports from Ethernet208 to Ethernet248 fail.
#### How I did it
- The fix to this problem is to change the order of QSFP driver initialization to I2C mux channels.
- Instead of the order i2c-10 to i2c-41, the order i2c-4 to i2c-35 is being utilized.
- Also, need to change the i2c-mux-channel number for Baseboard CPLD and switchboard CPLD in scripts to access them.
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
Currently we leveraged the Supervisor to monitor the running status of critical processes in each container and it is more reliable and flexible than doing the monitoring by Monit. So we removed the functionality of monitoring the critical processes by Monit.
How I did it
I removed the script process_checker and corresponding Monit configuration entries of critical processes.
How to verify it
I verified this on the device str-7260cx3-acs-1.