Why I did it
7050 S4Q31 mmu configuration is missing ALPM configurations, causing not enough memory reserved for routes. Orchagent crashes on a nightly testbed with 6400 route entries.
How I did it
Add the missing ALPM configurations.
How to verify it
Load the configuration on testbed and verified new configuration exists and no more crash.
Signed-off-by: Ying Xie ying.xie@microsoft.com
This PR contains the following changes
Original Arista-7050-QX-32S sku (32x40G ports) has been renamed to Arista-7050QX32S-Q32
Arista-7050-QX-32S is symlinked to Arista-7050QX-32S-S4Q31 (4x10G, 31x40G ports)
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Need proper MMU and Qos settings for Arista-7050QX-32S-S4Q31
How I did it
Updated the settings based on Arista-7050-QX-32S
Why I did it
PG profile settings need to be aligned with Arista-7050-QX-32S
How I did it
Copy over the current settings from Arista-7050-QX-32S and define params for 10G and 1G speeds as well
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
To enable autonegotiation/link training on some Broadcom-based platforms (Arista 7060 and 7260, Celestica DX010)
How I did it
Add appropriate SOC property for enabling the feature to the Broadcom config files of appropriate platforms
Also convert line endings to UNIX format for one Celestica file
Dynamic threshold setting changed to 0 and WRED profile green min threshold set to 250000 for Tomahawk devices
Changed the dynamic threshold settings in pg_profile_lookup.ini
Added a macro for WRED profiles in qos.json.j2 for Tomahawk devices
Necessary changes made in qos.config.j2 to use the macro if present
Signed-off-by: Neetha John <nejo@microsoft.com>
* Remove the divide by 4 operation to the under the hood SAI
This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture
This change must have support from SAI change to reach the correct
config
Signed-off-by: Wenda <wenni@microsoft.com>
* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool
Extend to 7060 and 6100
Signed-off-by: Wenda <wenni@microsoft.com>
* Add more TH/TH2 hwskus
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update config test
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Add TH2 ingress lossy profile
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Move the divide by 4 operation to SAI internal
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15
- Broadcom SAI 3.5 GA release 20190924.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* QoS config change: 1) DSCP mapping; 2) link pg/queue 6 to lossy buffer;
3) redistribute scheduler
Signed-off-by: Wenda <wenni@microsoft.com>
* Add scheduling weight to queue 2
Signed-off-by: Wenda <wenni@microsoft.com>
* Link pg/queue 2 to lossy buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the pg headroom for a7060-D48C8 50G
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for qos
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom size, and update egress lossy pool size accordingly
Signed-off-by: Wenda <wenni@microsoft.com>
* Update headroom pool size; Update ingress service pool and egress lossy
pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* a7260: update headroom pool size; Update ingress service pool and egress lossy pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* 1) DSCP 46 to 5; 2) ecn config for lossless traffic; 3) ecn on by default; 4) DWRR equal weight;
Signed-off-by: Wenda <wenni@microsoft.com>
* 1) link pg & queue 5 to lossy buffer profile; 2) ingress lossless alpha 1/8
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the test case for qos & buffer json template
Signed-off-by: Wenda <wenni@microsoft.com>
* Migrate a7050-qx32 and s6000 to use pg_profile lookup architecture
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom egress service pool for a7050-qx-32s, a7050-qx32, and s6000
Signed-off-by: Wenda <wenni@microsoft.com>
* Link queue 5 to lossy profile
Signed-off-by: Wenda <wenni@microsoft.com>
* Update arista drivers submodule
* Ignore the possible timestamp warning in tar extraction
* Add verbosity toggle to boot0
Console logging is slow because of the 9600 baud rate.
Some time can be saved by decreasing the console verbosity.
* Add hook mechanism in boot0.
Support additional features in boot0 via hooks.
Hooks are unpacked and executed at post-install or pre-exec time.
* Fix 7170 sensors.conf file
Fix critical temperature settings for MAX6658 sensors
* Fix the random swap of storage devices
For arista 7050 switches running with linux 4.9, it is likely the device
name of flash drive (/dev/sda) and usb (/dev/sdb) randomly swap in kernel
booting, depending on which one is ready first. It breaks the expectation
that flash will be mounted as root by setting root=/dev/sda1. This patch
will correct ROOT to flash device refering to the path under block_flash.
* Fix 7170 fancontrol
* Do not remove aquota.user file in boot0
This file is a filesystem protected file used by EOS.
It can be simply removed and will make the SONiC installation failed if
not skipped.
* Unify qos config with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change 7050 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: device/arista/x86_64-arista_7050_qx32/Arista-7050-QX32/qos.json.j2
modified: device/arista/x86_64-arista_7050_qx32s/Arista-7050-QX-32S/qos.json.j2
* Change a7060, a7260, s6000, s6100, z9100 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change mlnx devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: ../../../mellanox/x86_64-mlnx_msn2100-r0/ACS-MSN2100/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2410-r0/ACS-MSN2410/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/ACS-MSN2700/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/Mellanox-SN2700-D48C8/qos.json.j2
* Change barefoot devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: barefoot/x86_64-accton_wedge100bf_32x-r0/montara/qos.json.j2
modified: barefoot/x86_64-accton_wedge100bf_65x-r0/mavericks/qos.json.j2
* Change accton as7212 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: accton/x86_64-accton_as7212_54x-r0/AS7212-54x/qos.json.j2
* Apply PORT_QOS_MAP to active ports only
Signed-off-by: Wenda <wenni@microsoft.com>
* Update qos config test with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Update sample output of qos-dell6100.json
Signed-off-by: Wenda <wenni@microsoft.com>
* Remove generating the default port name and index list, i.e., remove the generate_port_lists macro, because PORT is always defined
Signed-off-by: Wenda <wenni@microsoft.com>
* Include pfc_to_pg_map according to platform asic type obtained from
/etc/sonic/sonic_version.yml rather than specifying per hwsku
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Customize TC_TO_PRIORITY_GROUP_MAP and
PFC_PRIORITY_TO_PRIORITY_GROUP_MAP for barefoot
Signed-off-by: Wenda <wenni@microsoft.com>
* Unify PFC_PRIORITY_TO_PRIORITY_GROUP_MAP: remove "0":"0", "1":"1" as
these two pgs do not generate PFC frames.
Signed-off-by: Wenda <wenni@microsoft.com>
* [updategraph] add support to use preset config instead of default minigraph
* Fix variable case
* Remove default minigraph case
* Remove default minigraphs and add default_sku files
for ecn on/off operations, which are conducted at per queue all interfaces granularity.
TODO:
Ideally, we should have ECN/WRED profile applied at per interface per queue
granularity, and we should do it for all hwskus under the device
directory, not just 7050.
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update sensors.conf for 7050QX-32 and 7050QX-32S
These two platforms were using a previous version of a kernel driver.
The new one names the i2c buses differently.
We therefore need to rename them here.
* Fix the default minigraph for the 7050QX-32S
The interface offset is invalid which makes sonic-cfggen generate an
invalid config_db.jon in rc.local.
This config then silently makes orchagent/syncd fail.
* Use the partition on which sonic-aboot.swi is
Instead of always assuming /mnt/flash, use the partition where the image
to be installed lies.
This allow for the image to be on any partition.
Move the ingress lossless profile from buffers.json.j2 to pg_profile_lookup.ini
Move pool and the rest of the profile from buffers.json.j2 to
buffers_defaults_t1.j2
Add port speed info in port_config.ini
Make buffers_default_t1.j2 the default profile in buffers.json.j2
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* First part of skipping not used port for qos configuration
* Use active ports only to set QoS parameters for 6100
* Add a test for qos.json.j2
* Add a test for Dell S6100 buffers.json template
* Update submodulre
* Add Broadcom config files for Arista-7050-QX32 and Arista-7050-Q16S64 SKUs under respective directories
* Remove 'serdes_firmware_mode_xe=0x1' line from Arista 7050 Broadcom config files
* [test] Adding Broadcom configuration file test
In order to allow SONiC community to check in Broadcom configuration
file directly under device folder. We need to add this test to make
sure the contents of the configuration is compliant with Broadcom
specifications.
* Invoke test from Debian package builder
* Use $() syntax
* Remove the debug echo statement