If we need to stop swss during fast-reboot procedure on the boot up path,
it means that something went wrong, like syncd/orchagent crashed already,
we are stopping and restarting swss/syncd to re-initialize. In this case,
we should proceed as if it is a cold reboot.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [process-reboot-cause]Address the issue: Incorrect reboot cause returned when warm reboot follows a hardware caused reboot
1. check whether /proc/cmdline indicates warm/fast reboot.
if yes the software reboot cause file will be treated as the reboot cause.
finish
2. check whether platform api returns a reboot cause.
if yes it is treated as the reboot cause.
finish.
3. check whether /hosts/reboot-cause contains a cause.
if yes it is treated as the cause otherwise return unknown.
* [process-reboot-cause]Fix review comments
* [process-reboot-cause]address comments
1. use "with" statement
2. update fast/warm reboot BOOT_ARG
* [process-reboot-cause]address comments
* refactor the code flow
* Remove escape
* Remove extra ':'
In place editing (sed -i) seems having some issues with filesystem
interaction. It could leave 0 size file or corrupted file behind.
It would be safer to sed the file contents into a new file and switch
new file with the old file.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* lldpctl: put a lock around some commands to avoid race conditions
* Read all notifications in lldpctl_recv
* lib: fix memory leak
* lib: fix memory leak when handling I/O
* Update series
* Add watchdog-control service to disable watchdog during bootup
Disable only if it's applicable and the watchdog is enabled.
* Address the review comment
* Correct the watchdog start script name
* Change to call common watchdog api instead of platform specific
* Start watchdog control service after swss starts
* advance sonic-utility submodule
Patch isc-dhcp-relay in order to allow the relay agent to discover configured interfaces even if they are down.
Without this patch, the relay agent will not discover configured interfaces if they are down when the relay agent starts up. If the interface(s) then get brought up after the relay started, the relay will discard packets received on these interfaces and log the message, Discarding packet received on <iface_name> interface that has no IPv4 address assigned. This led to race conditions when starting SONiC (or loading configuration). To resolve this, the relay agent would need to be restarted with all configured interfaces up.
With this patch, the relay agent will discover all configured interfaces, whether or not they are up at the time the relay agent starts. Thus, the state of the configured interfaces can be down when the relay agent starts and brought up during the lifetime of the relay agent process, and the relay agent will relay packets as expected; it will not discard them.
* Added debug symbol to dhcp-relay.
Note: Master is different; Hence explicitly for 201811 only.
* Include debug symbols of isc-dhcp in its debug docker.
Include isc-dhcp src in source archive.
This change is intended to fix the issue with dpkg-query during build
process.
The symptom is dpkg-query failed to open package info file, usually
/var/lib/dpkg/updates/000?
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Revert "Configure buffer profile to all ports (#3561)" (#3628)
Configure buffer profile to all ports (#3561)
This reverts commit 8861cbe98e.
Signed-off-by: Wenda Ni <wenni@microsoft.com>
Submodule src/sonic-utilities 2ca1ae1..3ed25a4:
> Do not start pfcwd for M0 devices (#726)
> Make configlet application script idempotent for updates. (#728)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* BGPm for 201811 (#3601)
* Feature is downported
* Add monitors to the test minigraphs
* Test
* No pfx filer
* Fix bgp sample
* Quagga requires to activate peer-group before configuration
* Add bgpcfgd and bgpd.peer template
* Catch exception if rendering external template
* Fix tests
* Update minigraph.py to filter out front-panel ports that are not active
* Update cfggen tests to reflect new behavior
Signed-off-by: Danny Allen <daall@microsoft.com>
* Incorporate PR comments
- Update t0 tests to include additional device neighbors
- Refactor xml parsing logic
Submodule src/sonic-swss f09ddb4..49c9c16:
> Allow buffer profile apply after init (#1099)
> [aclorch]: Check for existing mirror table only when creating a new table (#1089)
> [201811] [portsorch] fix PortsOrch::allPortsReady() returns true when it should not (#1116)
> Address review comment: remove data member m_entriesCreated, which is introduced for dependancy resolution purpose. (#839)
> Fix PFC watchdog not getting lossless TC (#876)
Submodule src/sonic-utilities c049e54..2ca1ae1:
> Add a generic configlet application script (#716)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
interfaces-config service configures lo address. If bgp service
starts before lo address is configured, then following config
in zebra will not be applied.
route-map RM_SET_SRC permit 10
set src 10.1.0.32
The adds a few seconds delay in bgp service start