**- Why I did it**
There is a preference to use thermalctld instead of fancontrol for 201911 release branch. The Arista platform submodule updates and thermal policies in the platforms will allow Arista devices to use thermalctld instead of fancontrol.
**- How I did it**
I cherry-picked the necessary commits from master branch for sonic-platform-modules-arista into 201911 branch. I've also added the file to skip fancontrol and added the thermal policies json.
**- How to verify it**
On Gardena, Upperlake, Clearlake, and Lodoga thermalctld is up and running with no errors. Fans show ~29%.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
thermalctld throwing error messages because it is not yet fully configured, disabling it for now on arista platforms.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>