Update the sonic-swss-common submodule. The following are the commits in the submodule.
f01fede [debian/control] libswsscommon-dev depends on libbost-dev (#458)
607a8ce Convert return value of get_all function in SonicV2Connector to dict (#462)
Closes issue #6982.
The issue was root caused as we were using the unix_socket for reading from DB as a default mechanism (#5250). The redis unix socket is created as follows.
admin@str--acs-1:~$ ls -lrt /var/run/redis/redis.sock
srwxrw---- 1 root redis 0 Mar 6 01:57 /var/run/redis/redis.sock
So it used to work fine for the user "root" or if user is part of redis group ( admin was made part of redis group by default )
Check if the user is with sudo permissions then use the redis unix socket, else fallback to tcp socket.
This package was outdated and did not properly install on buster due to dependency changes.
This version should work on all DCS-7280CR3*-32[PD]4 platforms.
Signed-off-by: Samuel Angebault <staphylo@arista.com>
Why I did it
We skip install of CNI plugin, as we don't need. But this leaves node in "not ready" state, upon joining master.
To fix, we copy this dummy .conf file in /etc/cni/net.d
How I did it
Keep this file in /usr/share/sonic/templates and copy to /etc/cni/net.d upon joining k8s master.
How to verify it
Upon configuring master-IP and enable join, watch node join and move to ready state.
You may verify using kubectl get nodes command
Includes the following commits:
1673d25 [y_cable] refactor upgrade firmware API's; Fix vendor and part number API's read size for read_eeprom (#174)
ed93a15 [sonic_platform_base] Proper use of class and instance attributes (#173)
691de92 [sonic_y_cable] add stub function for upgrade firmware of Y cable and split the get_part_number and get_vendor API's (#171)
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
#### Why I did it
- The xcvrd service requires an event detection function, unplug or plug in the transceiver.
#### How I did it
- Add sysfs interrupt to notify userspace app of external interrupt
- Implement get_change_event() in chassis api.
- Also begin installing Python 3 sonic-platform package for Celestica platforms
As booting on DCS-7060DX4-32 would use the default sku of DCS-7060PX4-32 which is not compatible,
thus move some files around to properly separate the configurations that are device specific.
Signed-off-by: Samuel Angebault <staphylo@arista.com>
To adjust config db generated via minigraph per matchmode changes in fine grained ecmp. The changes are done so that nexthop IP based filtering can occur to determine routes as requiring Fine Grained ECMP, in the past the only mode was to use the IP prefix of the route for filtering, with this matchmode change we will use nexthop IP based filtering
Azure/SONiC#727
How I did it
Change will modify config db entry created for FG_NHG to include 'match_mode': 'nexthop-based' so that nexthop IP based filtering can occur to determine routes as requiring Fine Grained ECMP. Changes also remove FG_NHG_PREFIX entry since its not needed under matchmode nexthop-based.
#### Why I did it
It is possible to have DHCP relay configuration with no servers/
helpers which result in DHCP container to crash. This PR fixes this
issue by not starting DHCP relay for vlans with no DHCP helpers.
resolves: #6931closes: #6931
#### How I did it
Do not add program group for dhcp relay with not dhcp helpers
#### How to verify it
Unit test
#### Why I did it
Change buffer config for new SKU Mellanox-SN2700-D40C8S8
#### How I did it
Reuse the buffer config of SKU Mellanox-SN2700-D48C8
#### How to verify it
Run sonic-mgmt qos test and all passed
- Provide `hw-management-generate-dump.sh` for `show techsupport`
- Load `optoe3` for OSFP and QSFP-DD transceivers
- Enhance reboot-cause caching robustness
Signed-off-by: Samuel Angebault <staphylo@arista.com>
#### Why I did it
Some platforms have difficult to attach egress ACL to vlan.
#### How I did it
For egress ACL attaching to vlan, break them into vlan members.
#### How to verify it
Unit test
Tested in DUT
30d09be fix the muxcable state change notification received from other modules, omit the check inside hw_state table (#159)
32ec23c [xcvrd] Fix crash on platforms which support media settings with Python 3 (#158)
47bcf90 [xcvrd] Save the dom_capability of transceiver into db (#72)
b9381a5 [xcvrd] Fix xcvrd crash on other port prefixes (#123)
c3c1a59 [xcvrd] Make functions used for media setting python3 compatible (#153)
e179ffc [psud] Refactor unit tests; increase unit test coverage (#146)
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
It is possible that one interface attaches multiple vlans. The VlanInterface should be in tagged mode.
Signed-off-by: Qi Luo <qiluo-msft@users.noreply.github.com>
Fix a strange bug introduced by https://github.com/Azure/sonic-buildimage/pull/6832 which would only occur in environments with both Python 2 and Python 3 installed (e.g., the PMon container). Error messages such as the following would be seen:
```
ERR pmon#ledd[29]: Failed to load ledutil: module 'importlib' has no attribute 'machinery'
```
This is very odd, and it seems like the Python 2 version of importlib, which is basically just a stub, is taking precedence over the Python 3 version. I found that this occurs when calling `import importlib`. However, calling `import importlib.machinery` and `import importlib.util` causes the proper package to be referenced, and the `machinery` and `util` modules are loaded successfully. This is how it is specified in examples in the official documentation, however there is nothing mentioned regarding that it *should* be done this way or that `import importlib` is unreliable.
Also, since sonic-py-common is still used in environments with Python 2 installed we should maintain support for both Python 2 and 3 until we completely deprecate Python 2, so I have added this back in.
There is a bug in how pyangbind translates yang models into python bindings. The model always sets integer values to 0 by default, so there is no way to check if a user has provided a value that is equal to 0. This is problematic for ICMP and VLAN (among others) because 0 is a valid input value.
This change converts ICMP and VLAN fields to union types so that acl-loader will treat them as null values unless a user explicitly adds an integer value.
Signed-off-by: Danny Allen <daall@microsoft.com>
As of the merging of PR #6799, we are now installing a newer version of scapy via pip, therefore there is no longer a need to install the older Debian package.
- Why I did it
To fix PCIEd errors in log.
- How I did it
Update pcie.yaml with the right PCI addresses.
- How to verify it
Check logs, operation occurs each minute.
Signed-off-by: liora <liora@nvidia.com>
- Why I did it
Add support for new 64x200G SN4600 systems
- How I did it
Add all relevant files (w/o platform.json and hwsku.json as they will come later) with default SKU.
- How to verify it
Install image on switch, verify all ports are up and configured properly, run full platform SONiC tests.
#### Why I did it
Add new SKU for SN2700 Mellanox system that supports the following port configuration:
8 X 100G
40 X 50G
8 X 10G
#### How I did it
Add new Folder - "Mellanox-SN2700-D40C8S8" under /sonic-buildimage/device/mellanox/x86_64-mlnx_msn2700-r0/
that contains the relevant files supporting this SKU
the buffers are based on SKU: D48C8 . Later on it will be configured specific for this SKU
#### How to verify it
Bring up the image, run "show interface status" and make sure that all ports are up and reflect the following requirement:
Port 1/3 will be used as 4x10G
Port 2/4 - Not exist (blocked since 1 and 3 split to 4)
Port 7/8/9/10/23/24/25/26 will used as 100G
All other ports will be used as 2x50G
#### Which release branch to backport (provide reason below if selected)
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [X] 202012
#### Description for the changelog
Support new SKU under the name of SN2700-D40C8S8
In preparation for the merging of Azure/sonic-platform-common#173, which properly defines class and instance members in the Platform API base classes.
It is proper object-oriented methodology to call the base class initializer, even if it is only the default initializer. This also future-proofs the potential addition of custom initializers in the base classes down the road.
In preparation for the merging of Azure/sonic-platform-common#173, which properly defines class and instance members in the Platform API base classes.
It is proper object-oriented methodology to call the base class initializer, even if it is only the default initializer. This also future-proofs the potential addition of custom initializers in the base classes down the road.
In preparation for the merging of Azure/sonic-platform-common#173, which properly defines class and instance members in the Platform API base classes.
It is proper object-oriented methodology to call the base class initializer, even if it is only the default initializer. This also future-proofs the potential addition of custom initializers in the base classes down the road.
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
In the configuration of rsyslog, duplicate messages will be suppressed and reported in the format of message repeated n times.
Due to this behavior, if a critical process in a container exited unexpectedly, the alerting message will be written into syslog once
and not be written into syslog anymore until the second critical process exited. This PR aims to differentiate these alerting messages such that they will not be suppressed by rsyslogd and can appear in the syslog periodically.
How I did it
This PR adds a counter into the alerting message and shows how many minutes a critical process was not running.
How to verify it
I verified and test this implementation on a physical DUT.
#### Why I did it
To incorporate the below changes in DellEMC S5232, Z9264, Z9332 platforms.
- Update thermal high threshold values
- Make watchdog API Python2 and Python3 compatible
- Fix LGTM alerts
- Z9264: Fix get_change_event timer value
#### How I did it
- Use 'universal_newlines=True' in subprocess.Popen call.
- Change the timeout in 'get_change_event' to milliseconds to match specification in sonic_platform_common/chassis_base.py
The S6000 devices, the cold reboot is abrupt and it is likely to cause issues which will cause the device to land into EFI shell. Hence the platform reboot will happen after graceful unmount of all the filesystems as in S6100.
Moved the platform_reboot to platform_reboot_override and hooked it to the systemd shutdown services as in S6100
Migrate from using the `imp` module to using the `importlib` module. As of Python 3, the `imp` module has been deprecated in favor of the `importlib` module.
- Why I did it
System is stuck on 'starting' state on SimX platform because of infinite loop on 'hw-management-ready.sh' script .
The loop is polling to check if the hw-mgmt sysfs created before proceeding with the flow, for SimX platform the sysfs will never create so the system is not starting properly.
- How I did it
Add a condition to poll on hw-mgmt sysfs only if the switch is real HW and not SimX platform.
- How to verify it
Check "systemctl status hw-management.service" output on a SimX switch with this patch, the state will be "active".
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
- Why I did it
Mellanox SDK APIs support python 2 at the moment.
- How I did it
Mellanox SDK APIs support python 2 at the moment.
- How to verify it
Add python 2 to Mellanox syncd only.
- Which release branch to backport (provide reason below if selected)
docker exec -t syncd /bin/bash -c "sx_api_dbg_generate_dump.py /home/sx_api_dbg_dump"
You can see that it will work and generate /home/sx_api_dbg_dump
Signed-off-by: allas <allas@nvidia.com>
- Why I did it
Bug fixes
- In rare cases when thermal algorithm is reactivated after FAN/PSU insertion, FAN remains at high rpm
- When stop hw-management code received error in the log instead of exit code '0'.
- In SPC1 i2c sometimes collide with chip reset coming from SDK
- Remove raw eeprom data link, when working with PSU which don't have eeprom for "msn274x", "msn24xx" and "msn27xx" systems
- Fix memory leak on mlxsw_core_bus_device module removal
- How I did it
Update the hw-mgmt version number in the make file
Update the hw-mgmt repo pointer
- How to verify it
run platform related test cases on all Mellanox platform
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437
- How I did it
Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
- Why I did it
Group all SONiC services together and able to manage them together. Will be used in config reload command as much simpler and generic way to restart services.
- How I did it
Add services to sonic.target
- How to verify it
Together with Azure/sonic-utilities#1199
config reload -y
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>