- Why I did it
Fix issue: psu might use wrong voltage sysfs which causes invalid voltage value. The flow is like:
1. User power off a PSU
2. All sysfs files related to this PSU are removed
3. User did a reboot/config reload
4. PSU will use wrong sysfs as voltage node
- How I did it
Always try find an existing sysfs.
- How to verify it
Manual test
- Why I did it
The latest upgrade of Mellanox hw-mgmt V7.0020.1300 introduced a couple new kernel modules for new Mellanox platforms that have yet to be upstreamed to the linux kernel.
As these new platforms do not have SONiC support we elected not to upstream these new drivers to sonic-linux-kernel but hw-mgmt expects them to exist which is causing a non-functional error on switch boot.
Feb 15 00:09:55.374130 r-leopard-simx-74 ERR systemd-modules-load[269]: Failed to find module 'emc2305'
Feb 15 00:09:55.374141 r-leopard-simx-74 ERR systemd-modules-load[269]: Failed to find module 'ads1015'
To resolve this we can patch hw-mgmt to no longer attempt to load these modules by default.
- How I did it
Added a SONiC patch to Mellanox hw-mgmt in order to remove the unused kernel modules which were not upstreamed to sonic-linux-kernel
- How to verify it
Boot switch and verify there are no error logs regarding kernel modules failing to load.
- Why I did it
In SONiC thermal control algorithm, it compares thermal zone temperature with thermal zone threshold. Previously, a thermal zone with no thermal sensor can still get its threshold. However, a recently driver patch changes this behavior: a thermal zone with no thermal sensor will return 0 for threshold. We need to ignore such thermal zone.
- How I did it
Ignore thermal zones whose temperature is 0.
- How to verify it
Added unit test case and Manual test
- Why I did it
Update MFT to version 4.18.1-16 for bugs fixes and new SN2201 support
- How I did it
Advance to MFT tool version to 4.18.1-16
- How to verify it
Manually tested on all Mellanox platforms (ASIC FW Upgrade, link debug tools, CPLD upgrade, etc.)
- Why I did it
New version of mellanox platform management code available adding support for new platforms and fixing bugs.
- How I did it
1. Updated the submodule
2. Updated makefile version references
3. Regenerated SONiC patches
- Why I did it
Fix issue: 'sx_port_mapping_t' object has no attribute 'slot_id'. sx_port_mapping_t only has attribute slot.
- How I did it
Change slot_id to slot.
- How to verify it
Manual test
- Why I did it
Python select.select accept a optional timeout value in seconds, however, the value passes to it is a value in millisecond.
- How I did it
Transfer the value to millisecond.
- How to verify it
Manual test
- Why I did it
To include latest SDK fixes:
1. On CMIS modules, after low power configuration, the firmware waited for the module state to be ModuleReady instead of ModuleLowPower causing delays.
2. When connecting SN4600C, 100GbE port with CWDM4 module (Gen 3.0), link up time is 30 seconds.
and to include SAI fixes \ changes:
1. Reduce verbosity for resource check vendor data not found
2. Fix metadata validation, check default value on conditions check
3. Add 100MB, 10MB to 2201 system
4. L3 VXLAN overlay ECMP
5. VXLAN srcport API implementation
6. Fix scheduler profile null (default values) when set on sub group scheduler group
7. Fix ACL binding restoration when port leaves a LAG
8. Fix route logic for set next hop/action and reference counter for ECMP overlay
- How I did it
1. Updated SDK/FW submodule and relevant makefiles with the required versions.
2. Update SAI submodule and relevant makefile with the required version.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Why I did it
Requirements from Microsoft for fwutil update all state that all firmwares which support this upgrade flow must support upgrade within a single boot cycle. This conflicted with a number of Mellanox upgrade flows which have been revised to safely meet this requirement.
How I did it
Added --no-power-cycle flags to SSD and ONIE firmware scripts
Modified Platform API to call firmware upgrade flows with this new flag during fwutil update all
Added a script to our reboot plugin to handle installing firmwares in the correct order with prior to reboot
How to verify it
Populate platform_components.json with firmware for CPLD / BIOS / ONIE / SSD
Execute fwutil update all fw --boot cold
CPLD will burn / ONIE and BIOS images will stage / SSD will schedule for reboot
Reboot the switch
SSD will install / CPLD will refresh / switch will power cycle into ONIE
ONIE installer will upgrade ONIE and BIOS / switch will reboot back into SONiC
In SONiC run fwutil show status to check that all firmware upgrades were successful
- Why I did it
Optimize thermal control policies to simplify the logic and add more protection code in policies to make sure it works even if kernel algorithm does not work.
- How I did it
Reduce unused thermal policies
Add timely ASIC temperature check in thermal policy to make sure ASIC temperature and fan speed is coordinated
Minimum allowed fan speed now is calculated by max of the expected fan speed among all policies
Move some logic from fan.py to thermal.py to make it more readable
- How to verify it
1. Manual test
2. Regression
Why I did it
Recently additional sensors that were needed only for specific system added to all systems and caused errors.
How I did it
* Include CPU board and switch board sensors only on SN2201 system
* Fix issue in test_chassis_thermal, now it skips non existing thermals.
How to verify it
Run show platform temperature
Signed-off-by: liora <liora@nvidia.com>
- Why I did it
Add new Spectrum-4 system support SN5600 on top of Nvidia ASIC simulator.
- How I did it
Add all relevant system and simulator SKU.
Updated syseeprom.hex and related directories to reflect Nvidia SN5600 brand name.
- How to verify it
Tested init flow, basic show commands, up interfaces, traffic test.
Signed-off-by: Raphael Tryster <raphaelt@nvidia.com>
- Why I did it
Rename platform x86_64-mlnx_msn4800 to x86_64-nvidia_msn4800
- How I did it
Rename platform folder as well as all code that reference the platform name
- How to verify it
Manual test
Depends on #9358
Why I did it
Adjust LED logical according to hw-mgmt change.
How I did it
Add a trigger to set LED to blink.
How to verify it
Manual test
The same docker image is built multiple times after upgrading to bullseye, the build time is increased to about 15 hours from 6 hours.
See log: https://dev.azure.com/mssonic/be1b070f-be15-4154-aade-b1d3bfb17054/_apis/build/builds/50390/logs/9
Line 1437: 2021-11-11T11:15:02.7094923Z [ building ] [ target/docker-sonic-telemetry.gz ]
Line 1446: 2021-11-11T11:37:41.1073304Z [ finished ] [ target/docker-sonic-telemetry.gz ]
Line 1459: 2021-11-11T11:38:20.6293007Z [ building ] [ target/docker-sonic-telemetry.gz-load ]
Line 1462: 2021-11-11T11:38:28.1250201Z [ finished ] [ target/docker-sonic-telemetry.gz-load ]
Line 2906: 2021-11-11T18:57:42.8207365Z [ building ] [ target/docker-sonic-telemetry.gz ]
Line 2917: 2021-11-11T19:43:47.1860961Z [ finished ] [ target/docker-sonic-telemetry.gz ]
Line 3997: 2021-11-11T22:49:35.0196252Z [ building ] [ target/docker-sonic-telemetry.gz ]
Line 4002: 2021-11-11T23:14:00.4127728Z [ finished ] [ target/docker-sonic-telemetry.gz ]
How I did it
Place the python wheels in another folder relative to the build distribution.
Co-authored-by: Ubuntu <xumia@xumia-vm1.jqzc3g5pdlluxln0vevsg3s20h.xx.internal.cloudapp.net>
Why I did it
Nvidia platform API does not support set LED to orange
How I did it
Allow user to set LED to orange
How to verify it
Added unit test
Manual test
- Why I did it
Add support for SN2201 platform
- How I did it
Add required content for SN2201 platform
Note: still missing kernel driver support for this system. Once all is upstream will be updated as well.
- How to verify it
Install and basic sanity tests including traffic.
Signed-off-by: liora liora@nvidia.com
- Why I did it
To include latest fixes.
SAI
1. Reclaim buffers for port which is admin down
2. Support for Spectrum-4 os Nvidia ASIC simulation
3. Support for SN2201
4. Fix host interface table entry, one channel per trap (fix sflow double registration)
5. 2 new queue counters - ecn marked packets + shared current occupancy
6. Fix storm policer unknown unicast
7. Add key/value for accuflow counters
8. Add MAC move
9. Add mirror congestion mode attribute
SDK
1. Under various circumstances, Ethernet ports falsely showed that InfiniBand cables were connected.
2. In SN4600C, at times, the link up time in both DAC and optics cables may, in the worst case, take up to 15 seconds.
3. Using SN4600C with copper or optics loopback cables in NRZ speeds, link may raise in long link up times
4. When ECMP has high amount of next-hops based on VLAN interfaces, in some rare cases, packets will get a wrong VLAN tag and will be dropped.
5. When connecting Spectrum devices with optical transceivers that support RXLOS, remote side port down might cause the switch firmware to get stuck and cause unexpected switch behavior.
6. Aggregation event is missing for WJH L2 drop reason 'Unicast egress port list is empty'.
7. Tying the SCL and SDA of the optical modules to 3.3V causes errors.
8. On SN4600, there was a delay of more than 10 seconds from the time a data packet is sent from CPU until it is transmitted through one of the switch ports.
9. While using SN4600C system with Finisar FTLC1157RGPL 100GbE CWDM4 modules, intermittent link flaps across multiple ports may be observed.
10. In Spectrum-2 and Spectrum-3 systems, link did not work in auto-negotiation when connected to Marvell PHY. KR mechanism has been enhanced to integrate with Marvell PHY.
11. The tunnel counter counts the drop packets now for Spectrum-2 and Spectrum-3 and consistent with Spectrum behavior and count the ECN dropped packets as well.
12. When connecting SN3800 to Cisco-9000, fast-linkup flow will fail and will rise in the normal flow.
13. Race condition in WJH library: when multiple threads load the LAG shared memory concurrently, the program may crash.
14. Add WJH L2 drop reason 'Unicast egress port list is empty' as a new drop reason.
15. Fixed a memory leak in sx_api_port_sflow_statistics_get API.
16. During initialization flow, the command interface that is used by the minimal driver and SDK caused the collision in the firmware since the same buffer is used in the firmware for the two interfaces.
17. Fix route issue on Kernel 5.10
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
To have an ability to use PRM sniffer.
- How I did it
Enabled the option in configure flags.
- How to verify it
Built and ran on switch. Enabled the feature in runtime and checked the sniffer recording.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
- Why I did it
To fix an issue that hw-mgmt patches were not applied. One patch was already in upstream hw-mgmt package thus applying it again caused an error and no other patches were applied. Also, I did it to improve the Makefile, so that the make will fail in case patches fail to apply.
- How I did it
Removed obsolete patch, made applying patches a hard failure in the build.
- How to verify it
Run the make and verify patches are applied.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
#### Why I did it
Updated hw-mgmt pointer to updated branch and to include new bugfixes. The hw-mgmt submodule was previously pointing to an orphaned commit which could not be fetched from github, this has now been resolved.
#### How I did it
Updated submodule pointer.
#### How to verify it
Clone down repository and update all submodules.
Signed-off-by: Stephen Sun stephens@nvidia.com
Why I did it
Support zero buffer profiles
Add buffer profiles and pool definition for zero buffer profiles
Support applying zero profiles on INACTIVE PORTS
Enable dynamic buffer manager to load zero pools and profiles from a JSON file
Dependency: It depends on Azure/sonic-swss#1910 and submodule advancing PR once the former merged.
How I did it
Add buffer profiles and pool definition for zero buffer profiles
If the buffer model is static:
Apply normal buffer profiles to admin-up ports
Apply zero buffer profiles to admin-down ports
If the buffer model is dynamic:
Apply normal buffer profiles to all ports
buffer manager will take care when a port is shut down
Update buffers_config.j2 to support INACTIVE PORTS by extending the existing macros to generate the various buffer objects, including PGs, queues, ingress/egress profile lists
Originally, all the macros to generate the above buffer objects took active ports only as an argument
Now that buffer items need to be generated on inactive ports as well, an extra argument representing the inactive ports need to be added
To be backward compatible, a new series of macros are introduced to take both active and inactive ports as arguments
The original version (with active ports only) will be checked first. If it is not defined, then the extended version will be called
Only vendors who support zero profiles need to change their buffer templates
Enable buffer manager to load zero pools and profiles from a JSON file:
The JSON file is provided on a per-platform basis
It is copied from platform/<vendor> folder to /usr/share/sonic/temlates folder in compiling time and rendered when the swss container is being created.
To make code clean and reduce redundant code, extract common macros from buffer_defaults_t{0,1}.j2 of all SKUs to two common files:
One in Mellanox-SN2700-D48C8 for single ingress pool mode
The other in ACS-MSN2700 for double ingress pool mode
Those files of all other SKUs will be symbol link to the above files
Update sonic-cfggen test accordingly:
Adjust example output file of JSON template for unit test
Add unit test in for Mellanox's new buffer templates.
How to verify it
Regression test.
Unit test in sonic-cfggen
Run regression test and manually test.
- Why I did it
When PSU is powered off, the PSU is still on the switch and the air flow is still the same. In this case, it is not necessary to set FAN speed to 100%.
- How I did it
When PSU is powered of, don't treat it as absent.
- How to verify it
Adjust existing unit test case
Add new case in sonic-mgmt
- Why I did it
Support PSU voltage high/low thresholds and power max threshold
1. Add thresholds support for voltage and power.
2. As thresholds are not supported on all platforms, we need to check the capability first and fetch thresholds only if it is supported.
- How I did it
- How to verify it
Run regression test and manual test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
#### Why I did it
Mellanox builds were failing intermittently due to the `issue_version` file and MFT package not building correctly in the Azure pipeline environment (both of these packages were patched to build correctly with bullseye running on the host and buster running on the dockers)
#### How I did it
Fixed two problems:
1. BLDENV is not passed to the Makefiles so the references to this were replaced with correct logic
2. `issue_version` was not defined as a target for bullseye and as such was not cached. Altered the build such that it is defined as a target for bullseye (in the case of buster it builds the file, in the case of bullseye it copies from buster)
The previous PR fixing this was reverted as it is no longer necessary for a passing build and was not a long-term fix. https://github.com/Azure/sonic-buildimage/pull/9235
#### How to verify it
Build on AZP and verify success.
The issu-version file for Mellanox is generated from the Mellanox SDK
libraries. The SDK is installed into a Buster docker container, but the
issu-version file goes onto the base OS, which is Bullseye. To work
around this, the issu-version build rules explicitly copies the
issu-version file to target/files/bullseye/ during the Buster build.
Because of our build infra, if caching is enabled and a cache is being
used, then for issu-version, since it is technically built as part of
Buster, then only target/files/buster/issu-version is saved into the
cache, and target/files/bullseye/issu-version isn't cached. If this
cache gets used, then target/files/bullseye/issu-version is missing, and
the final image build fails.
This is to work around the current build issue where Mellanox builds are
failing. This is so that issu-version is always "built", so that copy is
made into the bullseye directory.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
* Make neccesary changed to mellanox platform code to build on Debian 11
* Revert use of backported kernel to build mft and elect to only build kernel module under bullseye
Allow mellanox platform to build and successfully switch packets in
Debian 11
Upgraded
* Mellanox SDK
* Mellanox Hardware Management
* Mellanox Firmware
* Mellanox Kernel Patches
Adjusted build system to support host system running bullseye and
dockers running buster.
ISSU will likely be broken. As of right now, the issu-version file is
not being generated during build.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
- Why I did it
In case an app.ext requires a dependency syncd^1.0.0, the RPC version of syncd will not satisfy this constraint, since 1.0.0-rpc < 1.0.0. This is not correct to put 'rpc' as a prerelease identifier. Instead put 'rpc' as build metadata in the version: 1.0.0+rpc which satisfies the constraint ^1.0.0.
- How I did it
Changed the way how to version in RPC and DBG images are constructed.
- How to verify it
Install app.ext with syncd^1.0.0 dependency on a switch with RPC syncd docker.
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
- Why I did it
* To support systems with dynamic port configuration
* Apply lazy initialization to faster the speed of loading platform API
- How I did it
* Add module.py to implement dynamic port configuration (aka line card model)
* Adjust chassis.py, platform.py, thermal.py, sfp.py to support dynamic port configuration
* Optimize existing code
- How to verify it
Platform regression on MSN4700, MSN3800 and MSN2700, 100% pass
Unit test covers all new changes.
- Why I did it
Bug fix:
bad_param request due to missing parser rest command while running mlxlink
- How I did it
Advance to MFT tool version to 4.17.2-12.
- How to verify it
Manually tested on all mellanox platforms.
- Why I did it
Add NVIDIA Copyright header to "mellanox" files
- How I did it
Add NVIDIA Copyright header as a comment for Mellanox files
- How to verify it
Sanity tests and PR checkers.
Why I did it
Currently the mellanox platform API is validating the file extensions of firmware packages to be installed for basic sanity checking. However, ONIE packages do not have an extension and as such if there is a "." in the name it is taken to be an extension and then fails the sanity check.
How I did it
I removed the check which ensures that ONIE images don't have a file extension.
How to verify it
Name the ONIE updater file 2021.onie and attempt to install it via fwutil install fw 2021.onie --yes
Why I did it
The fwutil update all utility expects the auto_update_firmware method in the Platform API to execute the update_firmware() call and not the install_firmware() call.
How I did it
Changed the method in the mellanox platform API component implementation.
How to verify it
Run fwutil update all with a CPLD update on a Mellanox platform and verify that it properly updates the firmware using the MPFA file.
- Why I did it
Advance to new Nvidia SAI release with the following changes:
New features:
- Align with new SDK/FW version 4.5.1006 and above and in parallel to existing used SDK/FW bundle
- Implement timestamp and egress_queue_index hostif packet attributes.
Bugs fixes:
- Fix compilation issues with gcc10
- Fix return code for buffer overflow for query enum values and query statistics capabilities
- Reduce verbosity of print in case packet ingress on invalid port
- Fix mirror Qos settings
- How I did it
Updated SAI version and submodule pointer
- How to verify it
Run regression tests from sonic-mgmt
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high, so that thermal algorithm would set fan speed to minimum allowed earlier and save power.
- How I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high
- How to verify it
Manual test
- Why I did it
Advance to Mellanox SAI ver 1.19.2 to pick up dynamic Policy Based Hashing support.
For this version above the static Policy Based Hashing is no longer supported.
For detailed release notes check https://github.com/Mellanox/SAI-Implementation/blob/sonic2111/release%20notes.txt
- How I did it
Updated SAI-Implementation submodule
- How to verify it
1. make configure PLATFORM=mellanox
2. make target/sonic-mellanox.bin
Run full regression as well as new dynamic PBH tests
Signed-off-by: Nazarii Hnydyn <nazariig@nvidia.com>
#### Why I did it
New PSU could install different type of fan, so fan max/min speed should be read per PSU
#### How I did it
The existing implementation read PSU max/min fan speed from a common file, change it to read from per PSU file
#### How to verify it
Manual test
- Why I did it
Update SDK\FW version to 4.4.3326\2008.3326. This version contains:
New Features:
1. Add support for Fast Boot for SN3800
Bug Fixing:
1. In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
2. On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
3. On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
4. Some Molex cables do not support speed after reboot
- How I did it
- How to verify it
Was verified by running regression tests that includes complete sonic-mgmt tests supported
- Why I did it
New release of MFT has the following changelog / RN
Fixed an issue that resulted in getting MVPD read errors from the mlxfwmanager during fast reboot.
Fixed mlxuptime sometimes generating a time less than previous due the wrong frequency calculation
- How I did it
Update makefile pointer to new version.
- How to verify it
Manually tested on all Mellanox platforms.