Fixes#13568
Upgrade from old image always requires squashfs mount to get the next image FW binary. This can be avoided if we put FW binary under platform directory which is easily accessible after installation:
admin@r-spider-05:~$ ls /host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
/host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
admin@r-spider-05:~$ ls -al /tmp/image-fw-new-loc.0-dirty-20230208.193534-fs/etc/mlnx/fw-SPC.mfa
lrwxrwxrwx 1 root root 66 Feb 8 17:57 /tmp/image-fw-new-loc.0-dirty-20230208.193534-fs/etc/mlnx/fw-SPC.mfa -> /host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
- Why I did it
202211 and above uses different squashfs compression type that 201911 kernel can not handle. Therefore, we avoid mounting squashfs altogether with this change.
- How I did it
Place FW binary under /host/image-/platform/mlnx/, soft links in /etc/mlnx are created to avoid breaking existing scripts/automation.
/etc/mlnx/fw-SPCX.mfa is a soft link always pointing to the FW that should be used in current image
mlnx-fw-upgrade.sh is updated to prefer /host/image-/platform/mlnx location and fallback to /etc/mlnx in squashfs in case new location does not exist. This is necessary to do image downgrade.
- How to verify it
Upgrade from 201911 to master
master to 201911 downgrade
master -> master reboot
ONIE -> master boot (First FW burn)
Which release branch to backport (provide reason below if selected)
- Why I did it
FW for Spectrum-4 ASIC not yet available
- How I did it
Remove in Mellanox fw make files to Spectrum-4 ASIC firmware binaries.
Remove from firmware upgrade scripts to be able Spectrum-4 ASIC.
- How to verify it
Run regression test
- Why I did it
To improve ASIC FW upgrade logging and have information about the cause of FW update failure in the log.
- How I did it
Added syslog logger support
In case the FW update has failed the update tool will give the cause of the failure in the output in the last line, starting with "Fail".
When running the tool, in case of a failed update, we will parse the output to retrieve the cause and log it.
Device #1:
----------
Device Type: ConnectX6DX
Part Number: MCX623106AN-CDA_Ax
Description: ConnectX-6 Dx EN adapter card; 100GbE; Dual-port QSFP56; PCIe 4.0/3.0 x16;
PSID: MT_0000000359
PCI Device Name: /dev/mst/mt4125_pciconf0
Base GUID: 0c42a103007d22d4
Base MAC: 0c42a17d22d4
Versions: Current Available
FW 22.32.0498 22.32.0498
PXE 3.6.0500 3.6.0500
UEFI 14.25.0015 14.25.0015
Status: Forced update required
---------
Found 1 device(s) requiring firmware update...
Device #1: Updating FW ...
FSMST_INITIALIZE - OK
Writing Boot image component - OK
Fail : The Digest in the signature is wrong
- How to verify it
mlnx-fw-upgrade.sh --upgrade
- Why I did it
Add support for compiling Spectrum-4 ASIC firmware to the SONiC image
Add support for Spectrum-4 ASIC firmware upgrade
- How I did it
Update Mellanox fw make files to include Spectrum-4 ASIC firmware binaries.
Update firmware upgrade scripts to be able to detect Spectrum-4 ASIC.
- How to verify it
Run regression tests
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
System is stuck on 'starting' state on SimX platform because of infinite loop on 'hw-management-ready.sh' script .
The loop is polling to check if the hw-mgmt sysfs created before proceeding with the flow, for SimX platform the sysfs will never create so the system is not starting properly.
- How I did it
Add a condition to poll on hw-mgmt sysfs only if the switch is real HW and not SimX platform.
- How to verify it
Check "systemctl status hw-management.service" output on a SimX switch with this patch, the state will be "active".
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
**- Why I did it**
Reduce the time it takes for the ASIC FW burn as part of the automatic FW upgrade procedure.
**- How I did it**
Add -d option to mlxfwmanager tool to use the faster MST device and not the default one which is not the fastest one.
**- How to verify it**
I manually changed ASIC FW followed by reboot command in order for FW upgrade to take place on deinit.
I manually changed ASIC FW followed by hard reset in order for FW upgrade to take place on init.
Signed-off-by: liora <liora@nvidia.com>
Install a new FW by specifying FW path (mlnx-fw-upgrade.sh /path/to/FW)
or use default at '/etc/mlnx/fw-SPC.mfa'
Signed-off-by: Stepan Blyschak <stepanb@mellanox.com>