Align SFP key names with new standard defined in https://github.com/Azure/sonic-platform-common/pull/97
- hardwarerev -> hardware_rev
- serialnum -> serial
- manufacturename -> manufacturer
- modelname -> model
- Connector -> connector
Merge most of the changes that recently made it to master.
This will be the last such merge operation and future commits will only cherry-pick fixes and targeted features.
Major fixes and features,
- reboot cause enhancement with more hardware reboot cause reporting
- fix reboot cause parsing issue with 201811 release
- fix get_change_event logic
- fix error message on missing sysfs entry by our plugins
- final piece of the platform refactors for fan and sensor reporting through the platform API
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
This PR has changes to support accessing the bcmsh and bcmcmd utilities on multi ASIC devices
Changes done
- move the link of /var/run/sswsyncd from docker-syncd-brcm.mk to docker_image_ctl.j2
- update the bcmsh and bcmcmd scripts to take -n [ASIC_ID] as an argument on multi ASIC platforms
- Xilinx/pericom peripherals are not actively used in DellEMC S6100 switch.
- These peripherals are throwing PCIE corrected messages in some of the units and filling syslog.
- Since it is not usable disabling it at startup.
**- Why I did it**
After discussed with Joe, we use the string "/usr/bin/syncd\s" in Monit configuration file to monitor
syncd process on Broadcom and Mellanox. Due to my careless, I did not find this bug during the
previous testing. If we use the string "/usr/bin/syncd" in Monit configuration file to monitor the
syncd process, Monit will not detect whether syncd process is running or not.
If we ran the command `sudo monit procmactch “/usr/bin/syncd”` on Broadcom, there will be three
processes in syncd container which matched this "/usr/bin/syncd": `/bin/bash /usr/bin/syncd.sh
wait`, `/usr/bin/dsserve /usr/bin/syncd –diag -u -p /etc/sai.d/sai.profile` and `/usr/bin/syncd –diag -
u -p /etc/sai.d/said.profile`. Monit will select the processes with the highest uptime (at there
`/bin/bash /usr/bin/syncd.sh wait`) to match and did not select `/usr/bin/syncd –diag -u -p
/etc/sai.d/said.profile` to match.
Similarly, On Mellanox Monit will also select the process with the highest uptime (at there
`/bin/bash /usr/bin/syncd.sh wait`) to match and did not select `/usr/bin/syncd –diag -u -p
/etc/sai.d/said.profile` to match.
That is why Monit is unable to detect whether syncd process is running or not if we use the string “/usr/bin/syncd” in Monit configuration file. If we use the string "/usr/bin/syncd\s" in Monit configuration file, Monit can filter out the process `/bin/bash /usr/bin/syncd.sh wait` and thus can correctly monitor the syncd process.
**- How I did it**
**- How to verify it**
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* Change port index in port_config.ini to 1-based
* Add default port index to port_config.ini, change platform plugins to accept 1-based port index
* fix port index in sfp_event.py
Verified after loading on TH platforms cpu usage gone down:
Previous:
PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND
2521 root 20 0 1512860 360452 63540 S 144.6 4.4 8:00.03 syncd
After Fix:
7500 root 20 0 1592420 350912 64184 S 45.4 4.3 3:50.99 syncd
**- Why I did it**
For decoding system EEPROM of S6000 based on Dell offset format and S6000-ON’s system EEPROM in ONIE TLV format.
**- How I did it**
- Differentiate between S6000 and S6000-ON using the product name available in ‘dmi’ ( “/sys/class/dmi/id/product_name” )
- For decoding S6000 system EEPROM in Dell offset format and updating the redis DB with the EEPROM contents, added a new class ‘EepromS6000’ in eeprom.py,
- Renamed certain methods in both Eeprom, EepromS6000 classes to accommodate the plugin-specific methods.
**- How to verify it**
- Use 'decode-syseeprom' command to list the system EEPROM details.
- Wrote a python script to load chassis class and call the appropriate methods.
UT Logs: [S6000_eeprom_logs.txt](https://github.com/Azure/sonic-buildimage/files/4735515/S6000_eeprom_logs.txt), [S6000-ON_eeprom_logs.txt](https://github.com/Azure/sonic-buildimage/files/4735461/S6000-ON_eeprom_logs.txt)
Test script: [eeprom_test_py.txt](https://github.com/Azure/sonic-buildimage/files/4735509/eeprom_test_py.txt)
**- Why I did it**
- Skip thermalctld in DellEMC S6000, S6100, Z9100 and Z9264 platforms.
- Change the return type of thermal Platform APIs in DellEMC S6000, S6100 and Z9100 platforms to 'float'.
**- How I did it**
- Add 'skip_thermalctld:true' in pmon_daemon_control.json for DellEMC S6000, S6100, Z9100 and Z9264 platforms.
- Made changes in thermal.py, for 'get_temperature', 'get_high_threshold' and 'get_low_threshold' to return 'float' value.
**- How to verify it**
- Check thermalctld is not running in 'pmon'.
- Wrote a python script to load Chassis class and then call the APIs accordingly and verify the return type.
For detecting transceiver change events through xcvrd in DellEMC S6000, S6100 and Z9100 platforms.
- In S6000, rename 'get_transceiver_change_event' in chassis.py to 'get_change_event' and return appropriate values.
- In S6100, implement 'get_change_event' through polling method (poll interval = 1 second) in chassis.py (Transceiver insertion/removal does not generate interrupts due to a CPLD bug)
- In Z9100, implement 'get_change_event' through interrupt method using select.epoll().
Update SAI/SDK/FW and MSN4700 device files to support 8 lanes 400G
Update SAI to 1.16.3
Update SDK to 4.4.0914
Update FW to *.2007.1112
Update MSN4700 device files to support 8 lanes 400G
* New SKU support for MSN3420
Signed-off-by: Shlomi Bitton <shlomibi@mellanox.com>
Conflicts:
device/mellanox/x86_64-mlnx_msn2700-r0/plugins/sfputil.py
* Add CPLD's
* Symlink fixes and semantics
* Adding new platform at end of lines
- Added support for Thermal event in Last Reboot Reason "show reboot-cause" command.
- Added support for sending log message in case of thermal shutdown.
sonic NOTICE root: Shutting down due to over temperature (40 degree, 30 degree, 34 degree)