- Why I did it
Update the sensors.conf and pcie.yaml according to the real hardware.
- How I did it
Update the sensors.conf and pcie.yaml
- How to verify it
run relevant sonic-mgmt test cases.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Why I did it
Today at most 128 LAGs are supported. This is not sufficient if there are many LAGs with just few ports.
How I did it
Increase LAG Ids to 1024 for DNX device.
Why I did it
When reboot the chassis by issuing "sudo reboot" on Supervisor card. The internal midplane communication xe0 should be shutdown to avoid double reboot on the linecard.
Added a udev link rule to disable the autoneg on AMD xgbe port Xe0 and Xe1 and make the setting in sync with the peer Broadcom greyhound ports.
How I did it
Modify the Nokia-7250IXRE specific reboot script on the Supervisor card to shutdown the internal interface xe0. Also move reboot linecard code to the top of the script to make sure the notification has been send to Linecard before shutdown the xe0 interface.
Introduced a new rule 80-net-by-driver.link to disable the autoneg on the AMD size. This change requires the latest NDK which contains the change to set the autoneg on the xe0 and xe1 port on the Greyhound.
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
Support Egress Mirroring on supported Arista platforms
How I did it
Add necessary soc properties for egress mirroring recycle ports to be created
Signed-off-by: Nathan Wolfe <nwolfe@arista.com>
Updated asic_port_names for all Arista LC SKUs to follow latest naming
conventions to remove redundant ASICx suffix. For
Arista-7800R3-48CQ2-C48, added the asic_port_name mapping.
Why I did it
sonic-sfp based sfp impl would be deprecated in future, change to sfp-refactor based implementation.
How I did it
Use the new sfp-refactor based sfp implementation for seastone.
How to verify it
Manual test sfp platform api or run sfp platform test cases.
Why I did it
For better accounting purposes, updating the ingress lossy traffic profile to use static threshold. This change is only intended for Th devices using RDMA-CENTRIC profiles
How I did it
Update the buffer templates for Th devices in RDMA-CENTRIC folder to use the correct threshold
How to verify it
Verified the changes manually on a Th device.
Existing unit tests render Th template from the RDMA-CENTRIC folder. Updated the expected output to use the correct threshold
Why I did it
Update dynamic threshold to -1 to get optimal performance for RDMA traffic
How I did it
Modified pg_profile_lookup.ini to reflect the correct value
Signed-off-by: Neetha John <nejo@microsoft.com>
Provide platform-components.json for Clearwater2 and Wolverine
These files are needed for fwutil platform sonic-mgmt tests to pass.
Fix PikeZ platform_components.json
Co-authored-by: Patrick MacArthur <pmacarthur@arista.com>
Co-authored-by: Andy Wong <andywong@arista.com>
Why I did it
Platform cases test_tx_disable, test_tx_disable_channel, test_power_override failed in dx010.
How I did it
Add i2c access algorithm for CPLD i2c adapters.
How to verify it
Verify it with platform_tests/api/test_sfp.py::TestSfpApi test cases.
To support 64 cores on arista skus. Fixesaristanetworks/sonic#77
Remapped recycle ports to lowers core port ids and set appl_param_nof_ports_per_modid to 64.
Why I did it
Seastone does not have the psu fans' status led, need to reflect it in platform.json.
How I did it
Set the psu fans status led available to false.
How to verify it
Verify it with platform_tests/api/test_psu_fans.py::TestPsuFans::test_set_fans_led case.
Why I did it
The sensors and sensord processes were reporting data on unused sensors.
This lead to ALARM messages or erroneous values that could be misinterpreted.
How I did it
Ignore the affected sensors in the sensors.conf
How to verify it
Check that there are no longer ALARM messages from sensord in the syslog or in the output of sensors
Why I did it
This change specifies the tuning values for each lane of the B52 phy chips. These values can be different for different ports. The values being set are under the assumption of optical transceivers. This change depends on the change to sonic-swss: sonic-net/sonic-swss#2158.
How to verify it
We verified the values are correctly set on the B52 chips of Arista 7280cr3, by reading them from the debug cli of the B52 driver.
*Why I did it
The current sonic image bringup failed on Silverstone:
4:56:15.957705 sonic NOTICE swss#orchagent: :- addDecapTunnel: Create overlay loopback router interface oid:6000000000520
*How I did it
Enable bcm switch Tunnel function on Silverstone.
*How to verify it
The new sonic image can bringup OK on Silverstone.
- Why I did it
Advance hw-mgmt service to V.7.0020.4100
Add missing thermal sensors that are supported by hw-mgmt package
Delay system health service before hw-mgmt has started on Mellanox platform in order to avoid reading some sensors before ready.
Depends on sonic-net/sonic-linux-kernel#305
- How I did it
1. Update hw mgmt version
2. Add missing sensors
3. Delay service
- How to verify it
Regression test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
1. fix chassis test_set_fans_led case
2. fix chassis get_name case mismatch issue
3. fix fan_drawer test_set_fans_speed
4. fix component test_components test case
How I did it
Add corresponding configuration into chassis json file
How to verify it
Run platform tests cases to verify these failure cases
Why I did it
The 720DT-48S platform has variants with different chassis names, and these need to all be included in platform_components.json to ensure that sonic-mgmt platform_tests/fwutil/test_fwutil.py::test_fwutil_show passes
How I did it
Updated platform_components.json with the variant names for 720DT-48S.
How to verify it
Ran aforementioned testcase and verified that it passes on the different variants.
Why I did it
The current platform.json contains entries for thermals and SFPs that do not exist on Wolverine.
How I did it
I removed the incorrect entries.
How to verify it
Verify using applicable sonic-mgmt platform API tests.
- Why I did it
Support DSCP remapping in dual ToR topo on T0 switch for SKU Mellanox-SN4600c-C64, Mellanox-SN4600c-D48C40, Mellanox-SN2700, Mellanox-SN2700-D48C8.
- How I did it
Regarding buffer settings, originally, there are two lossless PGs and queues 3, 4. In dual ToR scenario, the lossless traffic from the leaf switch to the uplink of the ToR switch can be bounced back.
To avoid PFC deadlock, we need to map the bounce-back lossless traffic to different PGs and queues. Therefore, 2 additional lossless PGs and queues are allocated on uplink ports on ToR switches.
On uplink ports, map DSCP 2/6 to TC 2/6 respectively
On downlink ports, both DSCP 2/6 are still mapped to TC 1
Buffer adjusted according to the ports information:
Mellanox-SN4600c-C64:
56 downlinks 50G + 8 uplinks 100G
Mellanox-SN4600c-D48C40, Mellanox-SN2700, Mellanox-SN2700-D48C8:
24 downlinks 50G + 8 uplinks 100G
- How to verify it
Unit test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
Default pcieutil uses one configuration for all models of platform
How I did it
Take the configuration file as base for all models of concrete platform where model-specific devices are not listed in this configuration
How to verify it
Run pmon#pcied and verify that there is no error/warning logs on initialization step
Why I did it
fix DX010 fan drawer and watchdog platform test case issues
How I did it
1. Add fan_drawer get_maximum_consumed_power support
2. Adjust maximum watchdog timeout value check
How to verify it
Run test_fan_drawer and test_watchdog test cases.
Why I did it
By specifying 'status_led' 'controllable' to false for psu section, it means the platform is not yet supporting psu status led
How I did it
specify 'status_led' 'controllable' to false for psu section
How to verify it
by running test in pdb, manually add {'status_led' : {'controllable' : False}} in dictionary
this flag will be able to get False and skip testing:
ce290c735d/tests/platform_tests/api/test_psu.py (L337)
After upgrade to brcmsai 8.1, the sdk running environment (container) recommended with mininum memory size as below
TH4/TD4(ltsw) uses 512MB
TH3 used 300MB
Helix4/TD2/TD3/TH/TH 256 MB
Base on this requirement, adjust the default syncd share memory size and set the memory size for special ACISs in platform_env.conf file for different types of Broadcom ASICs.
How I did it
Add the platform_env.conf file if none of it for broadcom platform (base on platform_asic file)
Add the 'SYNCD_SHM_SIZE' and set the value
for ltsw(TD4/TH4) devices set to 512M at least (update the platform_env.conf)
for Td2/TH2/TH devices set to 256M
for TH3 set to 300M
verify
How to verify it
verify the image with code fix
Check with UT
Check on lab devices
On a problematic device which cannot start successfully
Run with the command
$ cat /proc/linux-kernel-bde
Broadcom Device Enumerator (linux-kernel-bde)
Module parameters:
maxpayload=128
usemsi=0
dmasize=32M
himem=(null)
himemaddr=(null)
DMA Memory (kernel): 33554432 bytes, 0 used, 33554432 free, local mmap
No devices found
$ docker rm -f syncd
syncd
$ sudo /usr/bin/syncd.sh start
Cannot get Broadcom Chip Id. Skip set SYNCD_SHM_SIZE.
Creating new syncd container with HWSKU Force10-S6000
a4862129a7fea04f00ed71a88715eac65a41cdae51c3158f9cdd7de3ccc3dd31
$ docker inspect syncd | grep -i shm
"ShmSize": 67108864,
"Tag": "fix_8.1_shm_issue.67873427-9f7ca60a0e",
On Normal device
$ docker inspect syncd | grep -i shm
"ShmSize": 268435456,
"Tag": "fix_8.1_shm_issue.67873427-9f7ca60a0e"
change the config syncd_shm.ini to b85=128m
$ docker rm -f syncd
syncd
$ sudo /usr/bin/syncd.sh start
Creating new syncd container with HWSKU Force10-S6000
3209ffc1e5a7224b99640eb9a286c4c7aa66a2e6a322be32fb7fe2113bb9524c
$ docker inspect syncd | grep -i shm
"ShmSize": 134217728,
"Tag": "fix_8.1_shm_issue.67873427-9f7ca60a0e",
change the config under
/usr/share/sonic/device/x86_64-dell_s6000_s1220-r0/Force10-S6000/platform_env.conf
and run command
$ cat /usr/share/sonic/device/x86_64-dell_s6000_s1220-r0/platform_env.conf
SYNCD_SHM_SIZE=300m
$ sudo /usr/bin/syncd.sh start
Creating new syncd container with HWSKU Force10-S6000
897f6fcde1f669ad2caab7da4326079abd7e811bf73f018c6dacc24cf24bfda5
$ docker inspect syncd | grep -i shm
"ShmSize": 314572800,
"Tag": "fix_8.1_shm_issue.67873427-9f7ca60a0e",
Signed-off-by: richardyu-ms <richard.yu@microsoft.com>
Eariler the SDK stat polling was erroneously set to once every msec
which is far more frequent than required by SWSS. The new setting, which
is consistent with other vendor SKUs, is once a second. The net result
is reduced CPU MHz by syncd.
Why I did it
Fix the following issues for Seastone platform:
- system-health issue: show system-health detail will not complete #9530, Celestica Seastone DX010-C32: show system-health detail fails with 'Chassis' object has no attribute 'initizalize_system_led' #11322
- show platform firmware updates issue: Celestica Seastone DX010-C32: show platform firmware updates #11317
- other platform optimization
How I did it
Modify and optimize the platform implememtation.
How to verify it
Manual run the test commands described in these issues.
Why I did it
Ragile adapter ra-b6510-32c ra-b6510-48v8c ra-b6910-64c ra-b6920-4s to kernel 5.x
Signed-off-by: “pettershao” pettershao@ragilenetworks.com
Fix code issue when SonicV2Connector.get() return None.
#### Why I did it
When database key does not exist, SonicV2Connector.get() will return None.
Code will break if not check return value.
#### How I did it
Check SonicV2Connector.get() return value before use it.
#### How to verify it
Pass all E2E test case.
Why I did it
Add two platform that support s3IP framework
How I did it
Add two platforms supporting S3IP SYSFS (TCS8400, TCS9400)
How to verify it
Manual test
Adding platform support for FS s5800-48t4s and s5800-48t8s-mars8p.
Both s5800-48t4s and s5800-48t8s-mars8p have 48 * 10/100/1000 Base-T ports, 4 * 10GE SFP+ Ports on Centec TsingMa.
s5800-48t4s is different from s5800-48t8s-mars8p in that:
The phy chip used by s5800-48t4s is Marvell 88e1680;
The phy chip used by s5800-48t4s-mars8p is Centec ctc21108;
Why I did it
This is to fix test_forward_ip_packet_with_0xffff_chksum_tolerant test failure on 720DT-48S. IP packets with checksum set to 0xffff will be forwarded with the same checksum on this platform, instead of updating to the correct value.
How I did it
Add bcm config sai_verify_incoming_chksum=0 so that checksum is updated instead of being left unchanged when checksum is 0xffff. Note that packets with invalid checksum are still dropped with this config.
Why I did it
On DNX (J2/J2c/J2c+) platforms, Single Path Nexthops and ECMp Nexthop resources(FECs) are shared. BRCM SAI do not have partition of this resource, and hence more single path Nexthop entries, causes ECMP programming to fail in scaled setup.
How I did it
Broadcom provided SAI changes to reserve resources for single path nexthop entries(More details in CSP: https://brcmsemiconductor-csm.wolkenservicedesk.com/wolken-support/allcases/request-details?requestId=CS00012251649).
Along with SAI changes, they provided configurable Macro/flag to reserve NON_ECMP entries.
This PR is to add that flag in various sai.profile files wherever applicable.
PS: We are reserving 3072 single path Nexthop entries on each Linecard. Calculation is as follows.
Max Slots per chassis: 8
Max No of Ports(each LC): 64
MyIP/Subnet Entries per port: 4(v4/v6)
Nbr Entries Per port: 2(v4/v6)
Total Non_ECMP Count: 8x64x(4+2) = 3072
How to verify it
Without this change, the ECMP group count will be shown as Max_count in 'crm show resources all' command, and with this change the ECMP group count will be decreased by 24(3072/128).
Port indexes of front panel ports are not contiguous in multi-asic because we didn't distiguish between
front panel and internal ports, e.g., recycle ports. Fix this by assigning index to front panel port first
and then internal ports.
Add missing aggregate port_config.ini needed by sonic-mgmt
Concatenate the ASIC specific port_config.ini from device/arista/x86_64-arista_7800r3a_36d2_lc/Arista-7800R3A-36D2-C36/[01] to create the aggregate file.