**- Why I did it**
BGP_MONITORS sessions don't have corresponding DEVICE_NEIGHBOR_METADATA CONFIG_DB entries in the minigraphs. Prevent bgpcfgd to wait on such entries for BGP_MONITORS sessions.
**- How I did it**
Set constructor argument to False that means - don't wait for device neighbors metadata info for BGP_MONITORS
**- How to verify it**
Build an image, write on your device, use a minigraph with BGP_MONITORS sessions. Check that sessions are populated in the config.
Avoiding recursive update of maps as it consumes stack frames. This
PR introduces iterative version of deep_update method.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Rendering templates show different orders when rendered using Python
2 vs Python 3. This PR prepare for Python 3 packaging by creating
new dir 'py2' for Python 2 rendered test cases.
singed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Jinja2 templates rendered using Python 3 interpreter, are required
to conform with Python 3 new semantics.
singed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Natural sorting of SONiC config gen output consumes lot of CPU cycles.
The sole use of natsorted was to make test comparison easier and so,
the natsorting logic is now relocated to the test suite. As a result
sonic-cfggen gained nearly 1 sec per call since we no longer import
natsorted module!
singed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
CONiC config gen requires jinja2<3.0.0 for stretch and byangbind
versions 0.60.0/0.80.1 for Python 2/3 respectively. byangbind
is installed in the build docker because when it installed it
pulls enum34 as dependent package which is not required for
Python 3 and it breaks the build.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
implements a new feature: "BGP Allow list."
This feature allows us to control which IP prefixes are going to be advertised via ebgp from the routes received from EBGP neighbors.
* [Multi-Asic] Forward SNMP requests destined to loopback IP, and coming in through the front panel interface
present in the network namespace, to SNMP agent running in the linux host.
* Updates based on comments
* Further updates in docker_image_ctl.j2 and caclmgrd
* Change the variable for net config file.
* Updated the comments in the code.
* No need to clean up the exising NAT rules if present, which could be created by some other process.
* Delete our rule first and add it back, to take care of caclmgrd restart.
Another benefit is that we delete only our rules, rather than earlier approach of "iptables -F" which cleans up all rules.
* Keeping the original logic to clean the NAT entries, to revist when NAT feature added in namespace.
* Missing updates to log_info call.
**- Why I did it**
There is error i2c mapping for port 11,12 and port 19, 20.
**- How I did it**
Fix to correct i2c mapping
Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
**- Why I did it**
- Platform API implementation using sonic-cfggen to get platform name and SKU name, which will fail when the database is not available.
- Chassis name is not correctly assigned, it shall be assigned with EEPROM TLV "Product Name", instead of SKU name
- Chassis model is not implemented, it shall be assigned with EEPROM TLV "Part Number"
**- How I did it**
1. Chassis
> - Get platform name from /host/machine.conf
> - Remove get SKU name with sonic-cfggen
> - Get Chassis name and model from EEPROM TLV "Product Name" and "Part Number"
> - Add function to return model
2. EEPROM
> - Add function to return product name and part number
3. Platform
> - Init EEPROM on the host side, so also can get the Chassis name model from EEPROM on the host side.
* src/sonic-platform-common 7255d3a...111dcf7 (2):
> [EEPROM] Add new function part_number_str to TlvInfoDecoder (#121)
> Fix fp_port_index error to get correct index type (#111)
**- Why I did it**
As discussed, This PR covers the below points.
1. Give precedence to platform.json only if both platform.json and hwsku.json file exist. In case only platform.json exists, we don’t allow breakout for that HWSKU and fallback to port_config.ini.
**- How I did it**
check for `hwsku.json` file presence under get_path_to_port_config_file function.
Signed-off-by: Sangita Maity <sangitamaity0211@gmail.com>
* buildimage: Add gearbox phy device files and a new physyncd docker to support VS gearbox phy feature
* scripts and configuration needed to support a second syncd docker (physyncd)
* physyncd supports gearbox device and phy SAI APIs and runs multiple instances of syncd, one per phy in the device
* support for VS target (sonic-sairedis vslib has been extended to support a virtual BCM81724 gearbox PHY).
HLD is located at b817a12fd8/doc/gearbox/gearbox_mgr_design.md
**- Why I did it**
This work is part of the gearbox phy joint effort between Microsoft and Broadcom, and is based
on multi-switch support in sonic-sairedis.
**- How I did it**
Overall feature was implemented across several projects. The collective pull requests (some in late stages of review at this point):
https://github.com/Azure/sonic-utilities/pull/931 - CLI (merged)
https://github.com/Azure/sonic-swss-common/pull/347 - Minor changes (merged)
https://github.com/Azure/sonic-swss/pull/1321 - gearsyncd, config parsers, changes to orchargent to create gearbox phy on supported systems
https://github.com/Azure/sonic-sairedis/pull/624 - physyncd, virtual BCM81724 gearbox phy added to vslib
**- How to verify it**
In a vslib build:
root@sonic:/home/admin# show gearbox interfaces status
PHY Id Interface MAC Lanes MAC Lane Speed PHY Lanes PHY Lane Speed Line Lanes Line Lane Speed Oper Admin
-------- ----------- --------------- ---------------- --------------- ---------------- ------------ ----------------- ------ -------
1 Ethernet48 121,122,123,124 25G 200,201,202,203 25G 204,205 50G down down
1 Ethernet49 125,126,127,128 25G 206,207,208,209 25G 210,211 50G down down
1 Ethernet50 69,70,71,72 25G 212,213,214,215 25G 216 100G down down
In addition, docker ps | grep phy should show a physyncd docker running.
Signed-off-by: syd.logan@broadcom.com
redis-py 3.0 used in master branch only accepts user data as bytes,
strings or numbers (ints, longs and floats). Attempting to specify a key
or a value as any other type will raise a DataError exception.
This PR address the issue bt converting datetime to str
We want to let Monit to unmonitor the processes in containers which are disabled in `FEATURE` table such that
Monit will not generate false alerting messages into the syslog.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
SWSS config script restore ARP/FDB/Routes. Restore neighbor script
uses config DB ARP information to restore ARP entries and so needs
to be started after swssconfig exits.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
buffer_default_*.j2 because of which internal cable length never gets
define and cause failure in test case test_multinpu_cfggen.py
Signed-off-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
Co-authored-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
libzmq5 is tcp/ipc communication library, needed by sairedis/syncd to communicate, as a new way (compared to current REDIS channel) to exchange messages which is faster than REDIS library and allows synchronous mode
this library is required in sairedis repo, swss repo, sonic-buildimage and sonic-build-tools to make it work
As part of Platform api testing for multiple platforms, this pull request adds a platform.json file which contains all
the static data for Mellanox-2700 platform. This file would provide all the platform specific data required for testing of all the Platform tests . As part of testing the API's the values of static/default objects within this specific platform file will be compared against the values returned by calling the Platform specific API's in a typical platform test
- Why I did it
For fixing PCA MUX attachment issue in Dell S6100 platform.
- How I did it
Wait till IOM MUX powered up properly and start I2C enumeration.
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
C64: 32 100G down links and 32 100G up links.
D112C8: 112 50G down links and 8 100G up links.
D24C52: 24 50G down links, 20 100G down links, and 32 100G up links.
D28C50: 28 50G down links, 18 100G down links, and 32 100G up links.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Enhanced Feature Table state enable/disbale for multi-asic platforms.
In Multi-asic for some features we can service per asic so we need to
get list of all services.
Also updated logic to return if any one of systemctl command return failure
and make sure syslog of feature getting enable/disable only come when
all commads are sucessful.
Moved the service list get api from sonic-util to sonic-py-common
Signed-off-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
* Make sure to retun None for both service list in case of error.
Signed-off-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
* Return empty list as fail condition
Signed-off-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
* Address Review Comments.
Made init_cfg.json.j2 knowledegable of Feature
service is global scope or per asic scope
Signed-off-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
* Fix merge conflict
* Address Review Comment.
Signed-off-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
Co-authored-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
for ipv6 communication between container and host in multi-asic
platforms. Address is assign is private address space of fd::/80
with prefix len selected as 80 so that last 48 bits can be
container mac address and and you prevent NDP neighbor cache
invalidation issues in the Docker layer.
Ref: https://docs.docker.com/config/daemon/ipv6/
Ref:https://medium.com/@skleeschulte/how-to-enable-ipv6-for-docker-containers-on-ubuntu-18-04-c68394a219a2
Signed-off-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
Co-authored-by: Abhishek Dosi <abdosi@abdosi-ubuntu-vm0.nwp1qucpfg5ejooejenqshkj3e.cx.internal.cloudapp.net>
To fix the following error when running
`logrotate /etc/logrotate.conf` :
```
error: dpkg:10 duplicate log entry for /var/log/alternatives.log
error: found error in file dpkg, skipping
```
update-alternatives is provided with dedicated logrotate config in newer dpkg package versions (probably starting from buster)
Signed-off-by: Volodymyr Boyko <volodymyrx.boiko@intel.com>
Install a newer version of rsyslog from stretch-backports to support -iNONE
Previous backport from master use -iNONE option which is only
available after v8.32.0
Signed-off-by: Guohan Lu <lguohan@gmail.com>