Why I did it
This PR is to update TC_TO_QUEUE_MAP|AZURE for SKU Arista-7050CX3-32S-D48C8 and Arista-7260CX3 T0.
The change is only to align the TC_TO_QUEUE_MAP for regular traffic and bounced traffic. It has no impact on business because we have no traffic being mapped to TC2 or TC6.
How I did it
Update TC_TO_QUEUE_MAP|AZURE , and test cases as well.
How to verify it
Verified by running test case test_j2files.py
/sonic/src/sonic-config-engine$ python3 setup.py test -s tests/test_j2files.py
running test
......
----------------------------------------------------------------------
Ran 29 tests in 25.390s
OK
- Why I did it
Remove extra empty lines in the SN2201 pg_profile_lookup.ini to make it aligned with other platforms.
This extra empty line could confuse some test cases which need to parse this file.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Why I did it
After PFC interop testing between 8102 and 7050cx3, data packet losses were observed on the Rx ports of the 7050cx3 (inflow from 8102) during testing. This was primarily due to the slower response times to react to PFC pause packets for the 8102, when receiving such frames from neighboring devices. To solve for the packet drops, the 7050cx3 pg headroom size has to be increased to 160kB.
How I did it
Modified the xoff threshold value to 160kB in the pg_profile file to allow for the buffer manager to read that value when building the image, and configuring the device
How to verify it
run "mmuconfig -l" once image is built
Signed-off-by: dojha <devojha@microsoft.com>
Why I did it
Content of platform.json was outdated and some platform_tests/api of sonic-mgmt were failing.
How I did it
Added the necessary values to platform.json
How to verify it
Running platform_tests/api of sonic-mgmt should yield 100% passrate.
Port index 22 is associated with phy23_config.json, then same port index 22 in phy24_config.json may cause gearbox port creation error. Port Ethernet22 maps to index 23.
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.
How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51
- Why I did it
This new breakout mode is required when a QSFP cable is used on the QSFP-DD supported 4700 port. since QSFP only uses the first 4 lanes, this mode is required to restrict the child ports to only use the first four lanes
- How I did it
Updated the platfrom.json file with the extended data
- How to verify it
Tested on one port:
root@msn-4700:/home/admin# show int status
Interface Lanes Speed MTU FEC Alias Vlan Oper Admin Type Asym PFC
----------- ------------------------------- ------- ----- ----- ------- ------ ------ ------- ----------------------------------------------- ----------
Ethernet0 0 25G 9100 N/A etp1a routed up up QSFP28 or later N/A
Ethernet1 1 25G 9100 N/A etp1b routed down up N/A N/A
Ethernet2 2 25G 9100 N/A etp1c routed down up N/A N/A
Ethernet3 3 25G 9100 N/A etp1d routed down up N/A N/A
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
Update the bcm config file system_ref_core_clock_khz param to
handlesystems with J2cplus linecards.
We need system_ref_core_clock_khz to be set to 1600000 for supporting j2
and j2cplus linecards on the same chassis.
- Why I did it
SN5600 has an additional service interface with a different parameters than other interfaces.
- How I did it
Added the etp65 interface with the correct parameters.
- How to verify it
Run platform test on SN5600 platform.
Check the service port can startup correctly.
- Why I did it
New SKU for MSN-4700 Platform i.e. Mellanox-SN4700-C128
Requirements:
* Breakout: Port 1-32: 4x100G
* Downlinks: 120 (1-30)
* Uplinks: 8 (31-32)
* Shared Headroom: Enabled
* Over Subscribe Ratio: 1:8
* Default Topology: T2
* Default Cable Length for T2: 1500m
* QoS params: The default ones defined in qos_config.j2 will be applied
* Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used
Additional Details:
Switch Type has to be programmed as SpineRouter through config_db.json in DEVICE_METADATA|localhost|type field for the buffer values & cable lengths defined in the buffers_defaults_t2.j2 to apply on the device
Cable Lengths Used for generating buffer_defaults_{t0,t1,t2}.j2 values
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
Why I did it
The SOC property changes are necessary to match #10519 which increases the number of system LAG IDs to 1024.
Description for the changelog
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
Why I did it
This linecard runs in multi-asic mode and therefore needs the use_pcie_id_chassis file to work properly.
The default_sku file was also missing which would break the boot when no minigraph is provided.
Description for the changelog
Add missing default_sku and use_pci_id_chassis configs for 7800R3A-36D2
Why I did it:
To fix hlx platform sfp+ module tx disable issue
How I did it:
Fix sfp+ tx disable function according SFF-8472 specification
Co-authored-by: Eric Zhu <erzhu@celestica.com>
- Why I did it
Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario
This is to port #11032 and #11299 from 202012 to master.
Support additional queue and PG in buffer templates, including both traditional and dynamic model
Support mapping DSCP 2/6 to lossless traffic in the QoS template.
Add macros to generate additional lossless PG in the dynamic model
Adjust the order in which the generic/dedicated (with additional lossless queues) macros are checked and called to generate buffer tables in common template buffers_config.j2
Buffer tables are rendered via using macros.
Both generic and dedicated macros are defined on our platform. Currently, the generic one is called as long as it is defined, which causes the generic one always being called on our platform. To avoid it, the dedicated macrio is checked and called first and then the generic ones.
Support MAP_PFC_PRIORITY_TO_PRIORITY_GROUP on ports with additional lossless queues.
On Mellanox-SN4600C-C64, buffer configuration for t1 is calculated as:
40 * 100G downlink ports with 4 lossless PGs/queues, 1 lossy PG, and 3 lossy queues
16 * 100G uplink ports with 2 lossless PGs/queues, 1 lossy PG, and 5 lossy queues
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Support new platform SN2201 and RJ45 port
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* remove unused import and redundant function
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* fix error introduced by rebase
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* Revert the special handling of RJ45 ports (#56)
* Revert the special handling of RJ45 ports
sfp.py
sfp_event.py
chassis.py
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove deadcode
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Support CPLD update for SN2201
A new class is introduced, deriving from ComponentCPLD and overloading _install_firmware
Change _install_firmware from private (starting with __) to protected, making it overloadable
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Initialize component BIOS/CPLD
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove swb_amb which doesn't on DVT board any more
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove the unexisted sensor - switch board ambient - from platform.json
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Do not report error on receiving unknown status on RJ45 ports
Translate it to disconnect for RJ45 ports
Report error for xSFP ports
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Add reinit for RJ45 to avoid exception
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Co-authored-by: Stephen Sun <5379172+stephenxs@users.noreply.github.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Improve throughput and latency for 7260 deployments
How I did it
Update the dynamic threshold to 0 and ECN settings as 2mb/10mb/5%
How to verify it
Updated unit tests to use the modified values for 7260 ecn settings.
* [device]: Add SAI checksum verify to TD3 config
* A new config option was added to control the value of IPV4_INCR_CHECKSUM_ORIGINAL_VALUE_VERIFY in the EGR_FLEX_CONFIG control register (this prevents checksums of 0xffff from being propagated to other devices)
Why I did it
This was an ask by Microsoft to provide:
7260 config.bcm file for hardware sku Arista-7260CX3-D92C16 (Named Arista-7260CX3-D96C16).
There are 16 100G uplinks:
Ethernet13-20/1
Ethernet45-52/1
All other ports are breakout to 2 50G ports.
How I did it
Copied existing Arista-7260CX3-D108C8 HWSKU and altered the bcm.config and port_config.ini files.
How to verify it
The new 100G ports do come up with a 201811 image using this HWSKU.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR
How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: bingwang <bingwang@microsoft.com>
Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950
SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64
How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.
For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7
How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
* [Tunnel PFC] Tests for adding property 'sai_remap_prio_on_tnl_egress'
Add tests for adding property 'sai_remap_prio_on_tnl_egress', this
property should only be added in dual tor environment.
Test done:
Run test test_j2files.py
Co-authored-by: richardyu <richardyu@contoso.com>
- Why I did it
1. SN2201 sai profile needs to be updated according to the latest hardware.
2. In the reboot script, need to use the common symbol link of the power_cycle sysfs instead of directly accessing it due to SN2201 sysfs is different than other platforms.
3. echo 1 > $SYSFS_PWR_CYCLE will trigger the reboot immediately, the following sleep 3 and echo 0 > $SYSFS_PWR_CYCLE will never be executed, can be removed.
- How I did it
1. Replace the SN2201 sai profile with the latest one.
2. In the platform_reboot script, replace the direct sysfs path with the symbol link path.
3. Remove the redundant code from platform_reboot
- How to verify it
Perform reboot on all the Nvidia platforms, and check all can be rebooted successfully.
Signed-off-by: Kebo Liu <kebol@nvidia.com>