- Why I did it
To create SDK dump on Mellanox devices when SDK event has occurred.
- How I did it
Set the SKUs keys needed to initialize the feature in SAI.
- How to verify it
Simulate SDK event and check that dump is created in the expected path.
#### Why I did it
Support 2km cables for Microsoft SKUs
#### How I did it
1. Update pg_profile_lookup.ini with 2000m cable supported
2. Update buffer configuration for t1 with uplink cable 2000m
- For SN3800 platform:
- C64:
- t0: 32 100G down links and 32 100G up links.
- t1: 56 100G down links and 8 100G up links with 2 km cable.
- D112C8: 112 50G down links and 8 100G up links.
- D24C52: 24 50G down links, 20 100G down links, and 32 100G up links.
- D28C50: 28 50G down links, 18 100G down links, and 32 100G up links.
- For SN2700 platform:
- D48C8: 48 50G down links and 8 100G up links.
- C32:
- t0: 16 100G down links and 16 100G up links.
- t1: 24 100G down links and 8 100G up links with 2 km cable.
- For SN4600C platform:
- D112C8: 112 50G down links and 8 100G up links.
#### How to verify it
Run regression test
#### Why I did it
The label for PSU related sensors on the Spectrum-2 platform is not aligned with the physical location of the PSU.
#### How I did it
Update the label in the sensor conf file for those relevant platforms
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Enable VXLAN src port range configuration via SAI profile for Mellanox-SN3800-D28C49S1 SKU
- How I did it
Added SAI_VXLAN_SRCPORT_RANGE_ENABLE=1 configuration to appropriate sai.profile
Signed-off-by: Andriy Yurkiv <ayurkiv@nvidia.com>
#### Why I did it
Current platform.json lacks some peripheral device related facts, like chassis/fan/pasu/drawer/thermal/components names, numbers, etc.
#### How I did it
Add platform device facts to the platform.json file
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
To fix PCIEd errors in log.
- How I did it
Update pcie.yaml with the right PCI addresses.
- How to verify it
Check logs, operation occurs each minute.
Signed-off-by: liora <liora@nvidia.com>
To fix [DPB| wrong aliases for interfaces](https://github.com/Azure/sonic-buildimage/issues/6024) issue, implimented flexible alias support [design doc](https://github.com/Azure/SONiC/pull/749)
> [[dpb|config] Fix the validation logic of breakout mode](https://github.com/Azure/sonic-utilities/pull/1440) depends on this
#### How I did it
1. Removed `"alias_at_lanes"` from port-configuration file(i.e. platfrom.json)
2. Added dictionary to "breakout_modes" values. This defines the breakout modes available on the platform for this parent port, and it maps to the alias list. The alias list presents the alias names for individual ports in order under this breakout mode.
```
{
"interfaces": {
"Ethernet0": {
"index": "1,1,1,1",
"lanes": "0,1,2,3",
"breakout_modes": {
"1x100G[40G]": ["Eth1"],
"2x50G": ["Eth1/1", "Eth1/2"],
"4x25G[10G]": ["Eth1/1", "Eth1/2", "Eth1/3", "Eth1/4"],
"2x25G(2)+1x50G(2)": ["Eth1/1", "Eth1/2", "Eth1/3"],
"1x50G(2)+2x25G(2)": ["Eth1/1", "Eth1/2", "Eth1/3"]
}
}
}
```
#### How to verify it
`config interface breakout`
Signed-off-by: Sangita Maity <samaity@linkedin.com>
- Why I did it
Support shared headroom pool
Signed-off-by: Stephen Sun stephens@nvidia.com
- How I did it
Port configurations for SKUs based on 2700/3800 platform from 201911
For SN3800 platform:
C64: 32 100G down links and 32 100G up links.
D112C8: 112 50G down links and 8 100G up links.
D24C52: 24 50G down links, 20 100G down links, and 32 100G up links.
D28C50: 28 50G down links, 18 100G down links, and 32 100G up links.
For SN2700 platform:
D48C8: 48 50G down links and 8 100G up links
C32: 16 100G downlinks and 16 100G uplinks
Add configuration for Mellanox-SN4600C-D112C8
112 50G down links and 8 100G up links.
- How to verify it
Run regression test.
- Why I did it
platform.json and hwsku.json files are required for a feature called Dynamic Port Breakout
- How I did it
Created capability files according to platform specification SN3800
- How to verify it
Full qualification requires bugs fixes reported under sonic-buildimage
Signed-off-by: Vadym Hlushko <vadymh@nvidia.com>
**- Why I did it**
To support dynamic buffer calculation.
This PR also depends on the following PRs for sub modules
- [sonic-swss: [buffermgr/bufferorch] Support dynamic buffer calculation #1338](https://github.com/Azure/sonic-swss/pull/1338)
- [sonic-swss-common: Dynamic buffer calculation #361](https://github.com/Azure/sonic-swss-common/pull/361)
- [sonic-utilities: Support dynamic buffer calculation #973](https://github.com/Azure/sonic-utilities/pull/973)
**- How I did it**
1. Introduce field `buffer_model` in `DEVICE_METADATA|localhost` to represent which buffer model is running in the system currently:
- `dynamic` for the dynamic buffer calculation model
- `traditional` for the traditional model in which the `pg_profile_lookup.ini` is used
2. Add the tables required for the feature:
- ASIC_TABLE in platform/\<vendor\>/asic_table.j2
- PERIPHERAL_TABLE in platform/\<vendor\>/peripheral_table.j2
- PORT_PERIPHERAL_TABLE on a per-platform basis in device/\<vendor\>/\<platform\>/port_peripheral_config.j2 for each platform with gearbox installed.
- DEFAULT_LOSSLESS_BUFFER_PARAMETER and LOSSLESS_TRAFFIC_PATTERN in files/build_templates/buffers_config.j2
- Add lossless PGs (3-4) for each port in files/build_templates/buffers_config.j2
3. Copy the newly introduced j2 files into the image and rendering them when the system starts
4. Update the CLI options for buffermgrd so that it can start with dynamic mode
5. Fetches the ASIC vendor name in orchagent:
- fetch the vendor name when creates the docker and pass it as a docker environment variable
- `buffermgrd` can use this passed-in variable
6. Clear buffer related tables from STATE_DB when swss docker starts
7. Update the src/sonic-config-engine/tests/sample_output/buffers-dell6100.json according to the buffer_config.j2
8. Remove buffer pool sizes for ingress pools and egress_lossy_pool
Update the buffer settings for dynamic buffer calculation
This PR has a dependency on community change to move PCIe config files from $PLATFORM/plugin folder to $PLATFORM/ folder
- Why I did it
To support PCIed daemon on Mellanox platforms
- How I did it
Add PCIed config yaml files for all Mellanox platforms
Update pmon daemon config files for SimX platforms
C64: 32 100G down links and 32 100G up links.
D112C8: 112 50G down links and 8 100G up links.
D24C52: 24 50G down links, 20 100G down links, and 32 100G up links.
D28C50: 28 50G down links, 18 100G down links, and 32 100G up links.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Calculate pool size in t1 as 24 * downlink port + 8 * uplink port
- Take both port and peer MTU into account when calculating headroom
- Worst case factor is decreased to 50%
- Mellanox-SN2700-C28D8 t0, assume 48 * 50G/5m + 8 * 100G/40m ports
- Mellanox-SN2700 (C32)
- t0: 16 * 100G/5m + 16 * 100G/40m
- t1: 16 * 100G/40m + 16 * 100G/300m
Signed-off-by: Stephen Sun <stephens@mellanox.com>
Co-authored-by: Stephen Sun <stephens@mellanox.com>
* Update the buffer size based on the latest excel
Signed-off-by: Stephen Sun <stephens@mellanox.com>
* Align the buffer configuration with the latest formula:
- reduce redundant "*2" in formula
- use port MTU for local sending the PFC frame and peer lossless MTU for peer sending lossless traffic
Buffer pool size updated accordingly.
Signed-off-by: Stephen Sun <stephens@mellanox.com>
The new feature system health support a platform based configuration file. Add configuration files for all Mellanox platform.
Add a configuration file for SN2700, other platform will use a soft link to it.
* Change port index in port_config.ini to 1-based
* Add default port index to port_config.ini, change platform plugins to accept 1-based port index
* fix port index in sfp_event.py
sai_xml contains info about port splits, previously it simply linked to the MSN3800 sai xml, which does not have splits. New version describes splits and speeds according to Mellanox-SN3800-D112-C8 SKU.
Practically it can cause port recreation on SAI init.
Signed-off-by: Mykola Faryma <mykolaf@mellanox.com>
* [plugins]add fan functions, add voltage, current, power for psu
* [plugins]link fanutil.py and psuutil.py to those in 2700
* [plugin]add thermal
* [plugin]add symbol links for thermalutil for all SKUs