Why I did it
After PFC interop testing between 8102 and 7050cx3, data packet losses were observed on the Rx ports of the 7050cx3 (inflow from 8102) during testing. This was primarily due to the slower response times to react to PFC pause packets for the 8102, when receiving such frames from neighboring devices. To solve for the packet drops, the 7050cx3 pg headroom size has to be increased to 160kB.
How I did it
Modified the xoff threshold value to 160kB in the pg_profile file to allow for the buffer manager to read that value when building the image, and configuring the device
How to verify it
run "mmuconfig -l" once image is built
Signed-off-by: dojha <devojha@microsoft.com>
Why I did it
Content of platform.json was outdated and some platform_tests/api of sonic-mgmt were failing.
How I did it
Added the necessary values to platform.json
How to verify it
Running platform_tests/api of sonic-mgmt should yield 100% passrate.
Port index 22 is associated with phy23_config.json, then same port index 22 in phy24_config.json may cause gearbox port creation error. Port Ethernet22 maps to index 23.
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.
How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51
Update the bcm config file system_ref_core_clock_khz param to
handlesystems with J2cplus linecards.
We need system_ref_core_clock_khz to be set to 1600000 for supporting j2
and j2cplus linecards on the same chassis.
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
Why I did it
The SOC property changes are necessary to match #10519 which increases the number of system LAG IDs to 1024.
Description for the changelog
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
Why I did it
This linecard runs in multi-asic mode and therefore needs the use_pcie_id_chassis file to work properly.
The default_sku file was also missing which would break the boot when no minigraph is provided.
Description for the changelog
Add missing default_sku and use_pci_id_chassis configs for 7800R3A-36D2
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Improve throughput and latency for 7260 deployments
How I did it
Update the dynamic threshold to 0 and ECN settings as 2mb/10mb/5%
How to verify it
Updated unit tests to use the modified values for 7260 ecn settings.
* [device]: Add SAI checksum verify to TD3 config
* A new config option was added to control the value of IPV4_INCR_CHECKSUM_ORIGINAL_VALUE_VERIFY in the EGR_FLEX_CONFIG control register (this prevents checksums of 0xffff from being propagated to other devices)
Why I did it
This was an ask by Microsoft to provide:
7260 config.bcm file for hardware sku Arista-7260CX3-D92C16 (Named Arista-7260CX3-D96C16).
There are 16 100G uplinks:
Ethernet13-20/1
Ethernet45-52/1
All other ports are breakout to 2 50G ports.
How I did it
Copied existing Arista-7260CX3-D108C8 HWSKU and altered the bcm.config and port_config.ini files.
How to verify it
The new 100G ports do come up with a 201811 image using this HWSKU.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR
How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: bingwang <bingwang@microsoft.com>
Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950
SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64
How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.
For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7
How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
* [Tunnel PFC] Tests for adding property 'sai_remap_prio_on_tnl_egress'
Add tests for adding property 'sai_remap_prio_on_tnl_egress', this
property should only be added in dual tor environment.
Test done:
Run test test_j2files.py
Co-authored-by: richardyu <richardyu@contoso.com>
* [Tunnel PFC] Add property for tunnel PFC
Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2
* Removed unused default_config.json
* Remove asic.conf file from HW SKUs directories as they are not used by upstream code
* Enable dynamic PCI ID identification on Otterlake2
Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
Why I did it
Fixes some pmon errors/warnings by providing missing configuration files
How I did it
Add missing pcie.yaml and sensors.conf for supported linecards
How to verify it
pcie-check should pass
sensors should display proper sensor names
Why I did it
The buffer pool & profile setting in buffer template was not correct and caused the errors like the following:
ERR swss#orchagent: :- parseReference: malformed reference:[BUFFER_PROFILE|ingress_lossless_profile]. Must not be surrounded by [ ]
How I did it
Fix the buffer pool & profile setting by removing "[]".
How to verify it
Loaded image with this fix in a switch and made sure the error was not seen anymore.
The v0.7.5 has bug fix for the support of gearbox port and macsec counters. It also includes a owl firmware update with owl.lz4.fw.1.94.0.bin.
How I did it
Update credo sai url for v0.7.5
Update gearbox_config.json with using firmware owl.lz4.fw.1.94.0.bin instead of owl.lz4.fw.1.92.1.bin
How to verify it
Test gearbox port and macsec counter successfully on A7280.
This PR includes necessary changes for correct generating BUFFER_QUEUE values in DB. Changes are based on the schema.md
Why I did it
Change format of generating BUFFER_QUEUE in DB according to schema.md and yang-model.
Old format:
"BUFFER_QUEUE": {
"Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
"profile": "profile"
},
"Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
"profile": "profile"
}
},
New format:
"BUFFER_QUEUE": {
"Ethernet0|queue": {
"profile": "profile"
},
"Ethernet0|queue": {
"profile": "profile"
},
"Ethernet4|queue": {
"profile": "profile"
},
"Ethernet4|queue": {
"profile": "profile"
},
"Ethernet8|queue": {
"profile": "profile"
},
"Ethernet8|queue": {
"profile": "profile"
},
...
}
How I did it
Updated structure of buffers_defaults jinja templates.
Signed-off-by: Oleksandr Kozodoi <oleksandrx.kozodoi@intel.com>
* [device config] Adding configuration for default route fallback
* Set sai_tunnel_underlay_route_mode attribute to fallback to default route if more specific route is unavailable.