* Add new device CIG CS6436-56P
* Delete minigraph.xml
It isn't necessary in the current system, just delete it
* Update qos.json.j2
* Update port_config.ini
Add the speed column. The cmd to show interface status as:
root@switch1:~# show interface status
Interface Lanes Speed MTU Alias Oper Admin Type Asym PFC
----------- --------------- ------- ----- ------------ ------ ------- ------ ----------
Ethernet0 8 25G 9100 Ethernet1/1 up up SFP N/A
Ethernet1 9 25G 9100 Ethernet2/1 up up SFP N/A
Ethernet2 10 25G 9100 Ethernet3/1 down down N/A N/A
Ethernet3 11 25G 9100 Ethernet4/1 down down N/A N/A
Ethernet4 12 25G 9100 Ethernet5/1 down down N/A N/A
Ethernet5 13 25G 9100 Ethernet6/1 down down N/A N/A
Ethernet6 14 25G 9100 Ethernet7/1 down down N/A N/A
Ethernet7 15 25G 9100 Ethernet8/1 down down N/A N/A
Ethernet8 16 25G 9100 Ethernet9/1 down down N/A N/A
Ethernet9 17 25G 9100 Ethernet10/1 down down N/A N/A
Ethernet10 18 25G 9100 Ethernet11/1 down down N/A N/A
Ethernet11 19 25G 9100 Ethernet12/1 down down N/A N/A
Ethernet12 20 25G 9100 Ethernet13/1 down down N/A N/A
Ethernet13 21 25G 9100 Ethernet14/1 down down N/A N/A
Ethernet14 22 25G 9100 Ethernet15/1 down down N/A N/A
Ethernet15 23 25G 9100 Ethernet16/1 down down N/A N/A
Ethernet16 32 25G 9100 Ethernet17/1 down down N/A N/A
Ethernet17 33 25G 9100 Ethernet18/1 down down N/A N/A
Ethernet18 34 25G 9100 Ethernet19/1 down down N/A N/A
Ethernet19 35 25G 9100 Ethernet20/1 down down N/A N/A
Ethernet20 40 25G 9100 Ethernet21/1 down down N/A N/A
Ethernet21 41 25G 9100 Ethernet22/1 down down N/A N/A
Ethernet22 42 25G 9100 Ethernet23/1 down down N/A N/A
Ethernet23 43 25G 9100 Ethernet24/1 down down N/A N/A
Ethernet24 48 25G 9100 Ethernet25/1 down down N/A N/A
Ethernet25 49 25G 9100 Ethernet26/1 down down N/A N/A
Ethernet26 50 25G 9100 Ethernet27/1 down down N/A N/A
Ethernet27 51 25G 9100 Ethernet28/1 down down N/A N/A
Ethernet28 56 25G 9100 Ethernet29/1 down down N/A N/A
Ethernet29 57 25G 9100 Ethernet30/1 down down N/A N/A
Ethernet30 58 25G 9100 Ethernet31/1 down down N/A N/A
Ethernet31 59 25G 9100 Ethernet32/1 down down N/A N/A
Ethernet32 64 25G 9100 Ethernet33/1 down down N/A N/A
Ethernet33 65 25G 9100 Ethernet34/1 down down N/A N/A
Ethernet34 66 25G 9100 Ethernet35/1 down down N/A N/A
Ethernet35 67 25G 9100 Ethernet36/1 down down N/A N/A
Ethernet36 68 25G 9100 Ethernet37/1 down down N/A N/A
Ethernet37 69 25G 9100 Ethernet38/1 down down N/A N/A
Ethernet38 70 25G 9100 Ethernet39/1 down down N/A N/A
Ethernet39 71 25G 9100 Ethernet40/1 down down N/A N/A
Ethernet40 72 25G 9100 Ethernet41/1 down down N/A N/A
Ethernet41 73 25G 9100 Ethernet42/1 down down N/A N/A
Ethernet42 74 25G 9100 Ethernet43/1 down down N/A N/A
Ethernet43 75 25G 9100 Ethernet44/1 down down N/A N/A
Ethernet44 76 25G 9100 Ethernet45/1 down down N/A N/A
Ethernet45 77 25G 9100 Ethernet46/1 down down N/A N/A
Ethernet46 78 25G 9100 Ethernet47/1 down down N/A N/A
Ethernet47 79 25G 9100 Ethernet48/1 down down N/A N/A
Ethernet48 84,85,86,87 100G 9100 Ethernet49/1 up up QSFP28 N/A
Ethernet49 80,81,82,83 100G 9100 Ethernet50/1 up up QSFP28 N/A
Ethernet50 92,93,94,95 100G 9100 Ethernet51/1 down down N/A N/A
Ethernet51 88,89,90,91 100G 9100 Ethernet52/1 down down N/A N/A
Ethernet52 108,109,110,111 100G 9100 Ethernet53/1 down down N/A N/A
Ethernet53 104,105,106,107 100G 9100 Ethernet54/1 down down N/A N/A
Ethernet54 116,117,118,119 100G 9100 Ethernet55/1 down down N/A N/A
Ethernet55 112,113,114,115 100G 9100 Ethernet56/1 down down N/A N/A
root@switch1:~#
Fixes "No ISSU version file found /etc/mlnx/issu-version"
when rebooting to different image;
Add aditional check condition.
Signed-off-by: Stepan Blyschak <stepanb@mellanox.com>
dell_ich module fails to load sometimes due to the failure of pci_get_drvdata().
This function is responsible for fetching INTEL PCI related memory handle in kernel. This is implemented in lpc_ich kernel module.
Due to race in addition/deletion of kernel modules, sometimes lpc_ich loads after dell_ich.
Because of this behaviour dell_ich module fails to load.
Fixed by addding dependency between modules.
Removed i2c_mux_gpio module from blacklist entry as it is not the original root case of this issue.
- Include helix4 fix.
- Include support for TD2 56854.
- Add dummy support for SAI_PORT_ATTR_ADVERTISED_SPEED.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [security kernel] Upgrade kernel from 4.9.110-3+deb9u2 to 4.9.110-3+deb9u6
short version: 4.9.0-7 to 4.9.0-8
See changelogs for security fixes:
https://tracker.debian.org/media/packages/l/linux/changelog-4.9.110-3deb9u6
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
* Update sonic-linux-kernel submodule after it was merged
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
knet driver unload takes about 30 seconds to remove netdevs. This cuts
into our warm reboot time budget.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Upgrade SAI to v1.2.4
* Add a new supported device accton as7116
* Add maintainer info for deb
* Add mk file for accton 7116
* fix some bug for sai 1.2.4
* fix git commit error for sdk and sai
* change sai and sdk deb name
* add config file for qos support
* initial commit
* Delete qos.json
* Delete buffers.json.j2
* Delete qos.json
* Delete buffers.json.j2
* Delete buffers.json.j2
* Delete qos.json
* add support for sai 1.3.0
* add qos and buffer file for device and add sensor driver for 7116
* change buffer template
* fix fan led bug
* add support for linux-4.9
* update device driver and update sdk and sai for support kernel 4.9
* Update arista drivers submodule
* Ignore the possible timestamp warning in tar extraction
* Add verbosity toggle to boot0
Console logging is slow because of the 9600 baud rate.
Some time can be saved by decreasing the console verbosity.
* Add hook mechanism in boot0.
Support additional features in boot0 via hooks.
Hooks are unpacked and executed at post-install or pre-exec time.
* Fix 7170 sensors.conf file
Fix critical temperature settings for MAX6658 sensors
* Fix the random swap of storage devices
For arista 7050 switches running with linux 4.9, it is likely the device
name of flash drive (/dev/sda) and usb (/dev/sdb) randomly swap in kernel
booting, depending on which one is ready first. It breaks the expectation
that flash will be mounted as root by setting root=/dev/sda1. This patch
will correct ROOT to flash device refering to the path under block_flash.
* Fix 7170 fancontrol
* Do not remove aquota.user file in boot0
This file is a filesystem protected file used by EOS.
It can be simply removed and will make the SONiC installation failed if