Commit Graph

1068 Commits

Author SHA1 Message Date
Stepan Blyshchak
2d4299308d
[swss.sh/syncd.sh] Trap only on EXIT (#11590)
When using trap on SIGTERM the script will not react to the SIGTERM signal sent while a child is executing.
I.e, the following script does not react on SIGTERM sent to it if it is
waiting for sleep to finish:

```

trap "echo Handled SIGTERM" 0 2 3 15

echo "Before sleep"
sleep inf
echo "After sleep"
```

Instead, trap only on EXIT which covers also a scenario with exit on
SIGINT, SIGTERM.

Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
2022-08-10 20:57:07 -07:00
Lawrence Lee
889741c9bc
[arp_update]: Resolve failed neighbors on dualtor (#11615)
In arp_update, check for FAILED or INCOMPLETE kernel neighbor entries and manually ping them to try and resolve the neighbor

Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
2022-08-09 16:19:42 -07:00
Ying Xie
a3e3530d1d
[write_standby] update write_standby.py script (#11650)
Why I did it
The initial value has to be present for the state machines to work. In active-standby dual-tor scenario, or any hardware mux scenario, the value will be updtaed eventually with a delay.

However, in active-active dual-tor scenario, there is no other mechanism to initialize the value and get state machines started.
So this script will have to write something at start up time.

For active-active dualtor, 'active' is a more preferred initial value, the state machine will switch the state to standby soon if
link prober found link not in good state.

How I did it
Update the script to always provide initial values.

How to verify it
Tested on active-active dual-tor testbed.

Signed-off-by: Ying Xie ying.xie@microsoft.com
2022-08-09 14:21:29 -07:00
Sudharsan Dhamal Gopalarathnam
5dc4eb9693
[vs]Preventing ebtables cfg to be applied on vs (#11585)
*Preventing ebtables rules to be applied on KVM image. The ebtables rules in SONiC are added to prevent ARP as well as L2 forwarding to be blocked in linux kernel since the hardware will take care of the actual L2 forward. However this is not the case with KVM where linux needs to forward even L2 packets
2022-08-04 09:18:00 -07:00
bingwang-ms
dc799356aa
Support different DSCP_TO_TC_MAP for T1 in dualtor deployment (#11569)
* Support different DSCP_TO_TC_MAP for T1 in dualtor deployment
2022-08-01 09:35:34 +08:00
Nikola Dancejic
8f6b568acf
[swss] Adding bgp container as dependent of swss (#11000)
What I did:
Added bgp as a dependent of swss

Why I did it:
bgp container was not restarting on swss crash. When swss crashes, linkmgrd
doesn't initate a switchover because it cannot access the default route from
orchagent. Bringing down bgp with swss will isolate the ToR, causing linkmgrd
to initiate a switchover to the peer ToR avoiding significant packet loss.

How I did it:
Added bgp to DEPENDENT

Signed-off-by: Nikola Dancejic <ndancejic@microsoft.com>
2022-07-29 16:22:20 -07:00
Jing Zhang
626919e250
Update WARM START FINALIZER to wait for linkmgrd to reconcile (#11477)
Spanning from sonic-net/sonic-linkmgrd#76, this PR is to update warm restart finalizer to wait for linkmgrd to be reconciled.

sign-off: Jing Zhang zhangjing@microsoft.com

Why I did it
To make sure finalizer save config after linkmgrd's reconciliation.

How I did it
Add linkmgrd to the reconciliation wait list of warmboot finalizer.

How to verify it
Verified on lab device, linkmgrd reconciled as expected.
2022-07-28 09:08:53 -07:00
Stepan Blyshchak
925a393e3d
[swss.sh] clear counters cache folder on swss cold/fast reload (#11244)
A change in sonic-utilities makes all cache files be saved into a
/tmp/cache. On swss restart this cache has to be removed in case swss
starts in cold or fast mode. A related cache restoration in the warmboot
finalizer script is also updated to use new location.

- Why I did it
To fix #9817. Clear the cache directory on swss.sh except for warm start.
Also, adopted finalize-warmboot script to take the cache directory.

- How I did it
A change in sonic-utilities makes all cache files be saved into a /tmp/cache. On swss restart this cache has to be removed in case swss starts in cold or fast mode. A related cache restoration in the warmboot finalizer script is also updated to use new location.

- How to verify it
Run togather with Azure/sonic-utilities#2232. Verify counters cache is removed on config reload, cold/fast reboots, swss restart.

Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
2022-07-28 12:03:22 +03:00
Lior Avramov
069b3a4669
[memory_checker] Do not check memory usage of containers if docker daemon is not running (#11476)
Fix in Monit memory_checker plugin. Skip fetching running containers if docker engine is down (can happen in deinit).
This PR fixes issue #11472.

Signed-off-by: liora liora@nvidia.com

Why I did it
In the case where Monit runs during deinit flow, memory_checker plugin is fetching the running containers without checking if Docker service is still running. I added this check.

How I did it
Use systemctl is-active to check if Docker engine is still running.

How to verify it
Use systemctl to stop docker engine and reload Monit, no errors in log and relevant print appears in log.

Which release branch to backport (provide reason below if selected)
The fix is required in 202205 and 202012 since the PR that introduced the issue was cherry picked to those branches (#11129).
2022-07-27 16:18:36 -07:00
abdosi
a380105461
Enable ARP Update Script for Packet based chassis. (#11465)
What I did:

    Following changes done for packet based chassis:-
    1> Run arp_update on LC's to resolve static route nexthops over backend
    port-channel interfaces.
    2> On Supervisor make sure arp_update exit gracefully
2022-07-26 16:50:16 -07:00
Iris Hsu
f323f56c54
flush VRF_OBJECT_TABLE table on state db when swss start (#11509)
*flush VRF_OBJECT_TABLE table on state db when swss start
2022-07-21 18:01:39 -07:00
gregshpit
5df09490dc
Ported Marvell armhf build on amd64 host for debian buster to use cross-comp… (#8035)
* Ported Marvell armhf build on x86 for debian buster to use cross-compilation instead of qemu emulation

Current armhf Sonic build on amd64 host uses qemu emulation. Due to the
nature of the emulation it takes a very long time, about 22-24 hours to
complete the build. The change I did to reduce the building time by
porting Sonic armhf build on amd64 host for Marvell platform for debian
buster to use cross-compilation on arm64 host for armhf target. The
overall Sonic armhf building time using cross-compilation reduced to
about 6 hours.

Signed-off-by: marvell <marvell@cpss-build3.marvell.com>

* Fixed final Sonic image build with dockers inside

* Update Dockerfile.j2

Fixed qemu-user-static:x86_64-aarch64-5.0.0-2 .

* Update cross-build-arm-python-reqirements.sh

Added support for both armhf and arm64 cross-build platform using $PY_PLAT environment variable.

* Update Makefile

Added TARGET=<cross-target> for armhf/arm64 cross-compilation.

* Reviewer's @qiluo-msft requests done

Signed-off-by: marvell <marvell@cpss-build3.marvell.com>

* Added new radius/pam patch for arm64 support

* Update slave.mk

Added missing back tick.

* Added libgtest-dev: libgmock-dev: to the buster Dockerfile.j2. Fixed arm perl version to be generic

* Added missing armhf/arm64 entries in /etc/apt/sources.list

* fix libc-bin core dump issue from xumia:fix-libc-bin-install-issue commit

* Removed unnecessary 'apt-get update' from sonic-slave-buster/Dockerfile.j2

* Fixed saiarcot895 reviewer's requests

* Fixed README and replaced 'sed/awk' with patches

* Fixed ntp build to use openssl

* Unuse sonic-slave-buster/cross-build-arm-python-reqirements.sh script (put all prebuilt python packages cross-compilation/install inside Dockerfile.j2). Fixed src/snmpd/Makefile to use -j1 in all cases

* Clean armhf cross-compilation build fixes

* Ported cross-compilation armhf build to bullseye

* Additional change for bullseye

* Set CROSS_BUILD_ENVIRON default value n

* Removed python2 references

* Fixes after merge with the upstream

* Deleted unused sonic-slave-buster/cross-build-arm-python-reqirements.sh file

* Fixed 2 @saiarcot895 requests

* Fixed @saiarcot895 reviewer's requests

* Removed use of prebuilt python wheels

* Incorporated saiarcot895 CC/CXX and other simplification/generalization changes

Signed-off-by: marvell <marvell@cpss-build3.marvell.com>

* Fixed saiarcot895 reviewer's  additional requests

* src/libyang/patch/debian-packaging-files.patch

* Removed --no-deps option when installing wheels. Removed unnecessary lazy_object_proxy arm python3 package instalation

Co-authored-by: marvell <marvell@cpss-build3.marvell.com>
Co-authored-by: marvell <marvell@cpss-build2.marvell.com>
2022-07-21 14:15:16 -07:00
Nazarii Hnydyn
e4e3adcbc2
[ssip]: Update config generator (#10991)
- Why I did it

To implement Syslog Source IP feature
In order to include the following commit: 8e5d478 [ssip]: Add CLI (#2191)

- How I did it
Updated syslog config template
Advanced submodule sonic-utilities

ea11b22 [sonic-bootchart] add sonic-bootchart (#2195)
8e5d478 [ssip]: Add CLI (#2191)
1dacb7f Replace pyswsssdk with swsscommon (#2251)

- How to verify it
make configure PLATFORM=mellanox
make target/sonic-mellanox.bin

Signed-off-by: Nazarii Hnydyn <nazariig@nvidia.com>
2022-07-20 10:05:13 +03:00
Stephen Sun
8f4a1b7b85
[Mellanox] Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario (#11261)
- Why I did it
Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario
This is to port #11032 and #11299 from 202012 to master.

Support additional queue and PG in buffer templates, including both traditional and dynamic model
Support mapping DSCP 2/6 to lossless traffic in the QoS template.
Add macros to generate additional lossless PG in the dynamic model
Adjust the order in which the generic/dedicated (with additional lossless queues) macros are checked and called to generate buffer tables in common template buffers_config.j2
Buffer tables are rendered via using macros.
Both generic and dedicated macros are defined on our platform. Currently, the generic one is called as long as it is defined, which causes the generic one always being called on our platform. To avoid it, the dedicated macrio is checked and called first and then the generic ones.
Support MAP_PFC_PRIORITY_TO_PRIORITY_GROUP on ports with additional lossless queues.
On Mellanox-SN4600C-C64, buffer configuration for t1 is calculated as:

40 * 100G downlink ports with 4 lossless PGs/queues, 1 lossy PG, and 3 lossy queues
16 * 100G uplink ports with 2 lossless PGs/queues, 1 lossy PG, and 5 lossy queues

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-07-20 09:48:15 +03:00
andywongarista
88d0ce5ce8
Add gbsyncd container for broncos (#11154)
* Add docker-gbsyncd-broncos support
* Address review comments
* Add socket to gbsyncd
* Upgrade gbsyncd-broncos to bullseye
2022-07-18 10:57:27 +08:00
bingwang-ms
52c36cd31f
Add flag to control the generation of PORT_QOS_MAP|global entry (#11448)
Why I did it
This PR is to add a flag to control whether to generate PORT_QOS_MAP|global entry or not.
It's because for some HWSKU, such as BackEndToRRouter and BackEndLeafRouter, there is no DSCP_TO_TC_MAP defined.
Hence, if the PORT_QOS_MAP|global entry is generated, OA will report some error because the DSCP_TO_TC_MAP map AZURE can not be found.

Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- saiObjectTypeQuery: invalid object id oid:0x7fddb43605d0
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- meta_generic_validation_objlist: SAI_SWITCH_ATTR_QOS_DSCP_TO_TC_MAP:SAI_ATTR_VALUE_TYPE_OBJECT_ID object on list [0] oid 0x7fddb43605d0 is not valid, returned null object id
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- applyDscpToTcMapToSwitch: Failed to apply DSCP_TO_TC QoS map to switch rv:-5
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- doTask: Failed to process QOS task, drop it
This PR is to address the issue.

How I did it
Add a flag require_global_dscp_to_tc_map to control whether to generate the PORT_QOS_MAP|global entry. The default value for require_global_dscp_to_tc_map is true. If the device type is storage backend, the value is changed to false. Then the PORT_QOS_MAP|global entry is not generated.

How to verify it
Update the current test_qos_dscp_remapping_render_template to cover storage backend.
2022-07-14 10:19:00 -07:00
Alexander Allen
429254cb2d
[arm] Refactor installer and build to allow arm builds targeted at grub platforms (#11341)
Refactors the SONiC Installer to support greater flexibility in building for a given architecture and bootloader. 

#### Why I did it

Currently the SONiC installer assumes that if a platform is ARM based that it uses the `uboot` bootloader and uses the `grub` bootloader otherwise. This is not a correct assumption to make as ARM is not strictly tied to uboot and x86 is not strictly tied to grub. 

#### How I did it

To implement this I introduce the following changes:
* Remove the different arch folders from the `installer/` directory
* Merge the generic components of the ARM and x86 installer into `installer/installer.sh`
* Refactor x86 + grub specific functions into `installer/default_platform.conf` 
* Modify installer to call `default_platform.conf` file and also call `platform/[platform]/patform.conf` file as well to override as needed
* Update references to the installer in the `build_image.sh` script
* Add `TARGET_BOOTLOADER` variable that is by default `uboot` for ARM devices and `grub` for x86 unless overridden in `platform/[platform]/rules.mk`
* Update bootloader logic in `build_debian.sh` to be based on `TARGET_BOOTLOADER` instead of `TARGET_ARCH` and to reference the grub package in a generic manner

#### How to verify it

This has been tested on a ARM test platform as well as on Mellanox amd64 switches as well to ensure there was no impact. 

#### Description for the changelog
[arm] Refactor installer and build to allow arm builds targeted at grub platforms

#### Link to config_db schema for YANG module changes

N/A
2022-07-12 15:00:57 -07:00
geogchen
5171589f4d
Add support to generate /e/n/i when there are multiple MGMT_INTERFACE (#11368)
Why I did it
Currently interfaces.j2 hardcodes to eth0 even when there are multiple interfaces in MGMT_INTERFACE. This change adds support to generate /e/n/i when there are multiple interfaces in MGMT_INTERFACE.

How I did it
By removing hardcoded eth0 when looping through MGMT_INTERFACE.

How to verify it
Verified through unit test.

Which release branch to backport (provide reason below if selected)
 201811
 201911
 202006
 202012
 202106
 202111
 202205
Description for the changelog
Link to config_db schema for YANG module changes
A picture of a cute animal (not mandatory but encouraged)
2022-07-12 14:55:15 -07:00
tjchadaga
4f95974669
Add load_minigraph option to include traffic-shift-away during config migration (#11403) 2022-07-12 10:08:58 -07:00
tjchadaga
849eb4bf32
Changes to persist TSA/B state across reloads (#11257) 2022-07-12 00:22:48 -07:00
Neetha John
7cd10019b8
Add backend acl template (#11220)
Why I did it
Storage backend has all vlan members tagged. If untagged packets are received on those links, they are accounted as RX_DROPS which can lead to false alarms in monitoring tools. Using this acl to hide these drops.

How I did it
Created a acl template which will be loaded during minigraph load for backend. This template will allow tagged vlan packets and dropped untagged

How to verify it
Unit tests

Signed-off-by: Neetha John <nejo@microsoft.com>
2022-07-06 10:24:16 -07:00
Stepan Blyshchak
ef8675d7ab
[sonic_debian_extension] install systemd-bootchart (#11047)
- Why I did it
Implemented sonic-net/SONiC#1001

- How I did it
Install systemd-bootchart tool and provide default config for it.

- How to verify it
Run build and verify systemd-bootchart is installed.

Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
2022-07-06 14:03:31 +03:00
judyjoseph
baaf8b085f
Revert "Update include_macsec flag if type is SpineRouter (#11141)" (#11306)
This reverts commit c9f36957db.
2022-07-01 11:00:30 -07:00
Jing Zhang
5d03b5d0df
Avoid write_standby in warm restart context (#11283)
Avoid write_standby in warm restart context.

sign-off: Jing Zhang zhangjing@microsoft.com

Why I did it
In warm restart context, we should avoid mux state change.

How I did it
Check warm restart flag before applying changes to app db.

How to verify it
Ran write_standby in table missing, key missing, field missing scenarios.
Did a warm restart, app db changes were skipped. Saw this in syslog:
WARNING write_standby: Taking no action due to ongoing warmrestart.
2022-06-29 21:34:02 -07:00
andywongarista
6e0559d5fa
[Arista] Add initial support for 720DT-48S (#10656)
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.

How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51
2022-06-29 09:56:24 -07:00
davidpil2002
8b7d069880
Add support for Password Hardening (#10323)
- Why I did it
New security feature for enforcing strong passwords when login or changing passwords of existing users into the switch.

- How I did it
By using mainly Linux package named pam-cracklib that support the enforcement of user passwords, the daemon named hostcfgd, will support add/modify password policies that enforce and strengthen the user passwords.

- How to verify it
Manually Verification-
1. Enable the feature, using the new sonic-cli command passw-hardening or manually add the password hardening table like shown in HLD by using redis-cli command

2. Change password policies manually like in step 1.
Notes:
password hardening CLI can be found in sonic-utilities repo-
P.R: Add support for Password Hardening sonic-utilities#2121
code config path: config/plugins/sonic-passwh_yang.py
code show path: show/plugins/sonic-passwh_yang.py

3. Create a new user (using adduser command) or modify an existing password by using passwd command in the terminal. And it will now request a strong password instead of default linux policies.

Automatic Verification - Unitest:
This PR contained unitest that cover:
1. test default init values of the feature in PAM files
2. test all the types of classes policies supported by the feature in PAM files
3. test aging policy configuration in PAM files
2022-06-29 15:34:56 +03:00
bingwang-ms
ac86f71287
Add extra lossy PG profile for ports between T1 and T2 (#11157)
Signed-off-by: bingwang <wang.bing@microsoft.com>

Why I did it
This PR brings two changes

Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable

DSCP_TO_TC_MAP
Before	After	Why do this change
"2" : "1"	"2" : "2"	Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1"	"6" : "6"	Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC

TC_TO_PRIORITY_GROUP_MAP
Before	After	Why do this change
"2" : "0"	"2" : "2"	Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0"	"6" : "6"	Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG

So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.

We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6

Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.

How I did it
Update the qos and buffer template.

How to verify it
Verified by UT.
2022-06-28 12:50:33 -07:00
judyjoseph
c9f36957db
Update include_macsec flag if type is SpineRouter (#11141)
Add the support to enable macsec when type is SpineRouter
2022-06-24 10:32:02 -07:00
geogchen
6a9c058a92
Revert "Add support for generating interface configuration in /etc/network/interfaces for multiple management interfaces (#11204)" (#11241)
This reverts commit 90a849ea85.

#### Why I did it
The interfaces unit test did not cover some of the conditions in interfaces.j2 that was changed in #11204.  Therefore reverting the change and add the tests before making the change to interfaces.j2.

#### How I did it
Git revert.

#### How to verify it

#### Which release branch to backport (provide reason below if selected)


- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
- [ ] 202205

#### Description for the changelog

#### Link to config_db schema for YANG module changes

#### A picture of a cute animal (not mandatory but encouraged)
2022-06-24 06:30:33 -07:00
Sudharsan Dhamal Gopalarathnam
9452095e25
[lldp]Fix lldp spawned after reboot when disabled (#11080)
- Why I did it
When LLDP is disabled through feature command, it gets spawned after reboot.

- How I did it
In syncd.sh check if the service is enabled before spawning automatically during cold reboot.

- How to verify it
Disable lldp feature. Perform cold reboot and verify its not spawned.
2022-06-22 03:11:41 +03:00
geogchen
90a849ea85
Add support for generating interface configuration in /etc/network/interfaces for multiple management interfaces (#11204)
* [Interfaces] Modify template to support multiple management interfaces

* Modify minigraph to process interfaces in sorted order

Signed-off-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>

* Add UT minigraph

Signed-off-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>

* make case insensitve comparison

Signed-off-by: George Chen <gechen@microsoft.com>

* Use natural sort

Signed-off-by: George Chen <gechen@microsoft.com>

Co-authored-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>
2022-06-21 10:16:10 -07:00
xumia
fdef1f0342
[Build]: Support to use symbol links for lazy installation targets to reduce the image size (#10923)
Why I did it
Support to use symbol links in platform folder to reduce the image size.
The current solution is to copy each lazy installation targets (xxx.deb files) to each of the folders in the platform folder. The size will keep growing when more and more packages added in the platform folder. For cisco-8000 as an example, the size will be up to 2G, while most of them are duplicate packages in the platform folder.

How I did it
Create a new folder in platform/common, all the deb packages are copied to the folder, any other folders where use the packages are the symbol links to the common folder.

Why platform.tar?
We have implemented a patch for it, see #10775, but the problem is the the onie use really old unzip version, cannot support the symbol links.
The current solution is similar to the PR 10775, but make the platform folder into a tar package, which can be supported by onie. During the installation, the package.tar will be extracted to the original folder and removed.
2022-06-21 13:03:55 +08:00
jingwenxie
fdc65d7600
Remove minigraph loading in updategraph script (#11146)
Why I did it
Minigraph will be deprecated in the future. So minigraph related reload should be deleted.

How I did it
Remove unused load_minigraph
2022-06-21 08:57:57 +08:00
Stepan Blyshchak
42576d2664
[auto-ts] add memory check (#10433)
#### Why I did it

To support automatic techsupport invokation in case memory usage is too high.

#### How I did it

Implemented according to https://github.com/Azure/SONiC/pull/939

#### How to verify it

UT, manual test on the switch.

*DEPENDS* on https://github.com/Azure/sonic-utilities/pull/2116
2022-06-20 09:39:05 -07:00
yozhao101
241f4454b4
[memory_checker] Do not check memory usage of containers which are not created (#11129)
Signed-off-by: Yong Zhao yozhao@microsoft.com

Why I did it
This PR aims to fix an issue (#10088) by enhancing the script memory_checker.

Specifically, if container is not created successfully during device is booted/rebooted, then memory_checker do not need check its memory usage.

How I did it
In the script memory_checker, a function is added to get names of running containers. If the specified container name is not in current running container list, then this script will exit without checking its memory usage.

How to verify it
I tested on a lab device by following the steps:

Stops telemetry container with command sudo systemctl stop telemetry.service

Removes telemetry container with command docker rm telemetry

Checks whether the script memory_checker ran by Monit will generate the syslog message saying it will exit without checking memory usage of telemetry.
2022-06-17 12:13:18 -07:00
bingwang-ms
83f23e26ff
Generate switch level dscp_to_tc_map entry from qos_config template (#11087)
* Generate switch level dscp_to_tc_map

Signed-off-by: bingwang <wang.bing@microsoft.com>
2022-06-17 08:44:30 +08:00
byu343
89020f53e4
[Arista] Add support support for 7060dx5_64s and 7060px5_64s (#10888)
Why I did it
This change adds the support for Arista 7060dx5_64s and 7060px5_64s

How I did it
How to verify it
We verified the platform driver is working and the ports are up on 7060dx5_64s and 7060px5_64s.
2022-06-16 09:51:42 -07:00
Samuel Angebault
30bfed92fd
[Arista] Add configuration files for 7050X4-32S platform (#10799)
Add most configuration files for the DCS-7050PX4-32S and DCS-7050DX4-32S.
This review only contains platform configuration files, dataplane ones will follow in future change.

Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
2022-06-16 09:42:10 -07:00
shlomibitton
1474ad76d8
[Mellanox] [pmon] Fix for PMON service not starting when restarting SWSS service after fast/warm reboot (#10901)
- Why I did it
Recent change to delay PMON service in case of fast/warm reboot introduce an issue when restarting only SWSS service after fast/warm reboot for Nvidia platform.
Since the timer is triggered only when the system boot, in a scenario when the system is after a fast/warm reboot and the user restart SWSS service, as part of syncd.sh script, PMON service will stop but the timer will not start again.

- How I did it
On syncd.sh script, in case of fast/warm indication, check if pmon.timer is running.
If it is running it means we are at the first boot and continue normally.
If it is not running, meaning the service was restarted, start the timer to keep the system behavior consistent.

- How to verify it
Run fast/warm reboot.
service swss restart.
Observe PMON service starting.

Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
2022-06-16 12:15:09 +03:00
jingwenxie
cca3b5be5b
Reduce logic in updategraph (#11010)
Why I did it
The dhcp_graph_url used by internal service is always set as "N/A". So we can make the updategraph logic short.

How I did it
Shorten 'if statement' logic for /tmp/dhcp_graph_url
2022-06-14 22:18:47 +08:00
judyjoseph
0b1ae9c43c
Cleanup macsec stateDB tables on restart (#11066)
Clean macsec tables in STATE_DB on start
2022-06-09 15:32:24 -07:00
bingwang-ms
1cc602c6af
Add two extra lossless queues for bounced back traffic (#10496)
Signed-off-by: bingwang <bingwang@microsoft.com>

Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950

SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64

How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.

For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7

How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
2022-06-02 13:03:27 -07:00
bingwang-ms
0c9bbee735
Update qos template to support SYSTEM_DEFAULT table (#10936)
* Update qos template to support SYSTEM_DEFAULT table

Signed-off-by: bingwang <wang.bing@microsoft.com>
2022-06-02 21:48:57 +08:00
xumia
0552d6b172
Support symcrypt fips config for aboot/uboot (#10729)
Why I did it
Support symcrypt fips config for aboot/uboot
2022-06-02 15:35:17 +08:00
Hua Liu
96954f0134
[swsscommon] Add c++ version sonic-db-cli from sonic-swss-common (#10825)
#### Why I did it
    Fix sonic-db-cli high CPU usage on SONiC startup issue: https://github.com/Azure/sonic-buildimage/issues/10218
    ETA of this issue will be 2022/05/31

#### How I did it
    Re-write sonic-cli with c++ in sonic-swss-common: https://github.com/Azure/sonic-swss-common/pull/607
    Modify swss-common rules and slave.mk to install c++ version sonic-db-cli.
    

#### How to verify it
    Pass all E2E test scenario.

#### Which release branch to backport (provide reason below if selected)

<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->

- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111

#### Description for the changelog
    Build and install c++ version sonic-db-cli from swss-common.

#### Link to config_db schema for YANG module changes
<!--
Provide a link to config_db schema for the table for which YANG model
is defined
Link should point to correct section on https://github.com/Azure/SONiC/wiki/Configuration.
-->

#### A picture of a cute animal (not mandatory but encouraged)
2022-06-01 08:05:53 +08:00
Lukas Stockner
c9b27cde71
[swss] Clear VXLAN tunnel table from State DB on startup (#10822)
* When reloading config after crashes, VTEP interfaces are sometimes not created since the tunnel still exists in the STATE_DB.
* Adding VXLAN_TUNNEL_TABLE to the list of tables to be cleaned in swss.sh fixes the problem.
2022-05-31 08:54:31 -07:00
davidpil2002
ab0930313b
[YANG] Add support for Password Hardening (#10322)
- Why I did it
Yang Model about password hardening feature, the sonic CLI of this feature was autogenerated from this Yang model

- How I did it
Create new Yang model in src/sonic-yang-models/yang-models/sonic-passwh.yang.

- How to verify it
There are unitests(yang test) in this P.R covering all the passwords policies with good and bad values cases.
Or is possible manually using the config/show password commands that were autogenerated from this Yang model. (this CLI code added in sonic-utilities)
2022-05-29 13:54:51 +03:00
xumia
f0dfd398a6
Revert "Reduce image size for lazy installation packages (#10775)" (#10916)
This reverts commit 15cf9b0d70.
Why I did it
Revert the PR #10775, for it has impact on onie installation.
It is caused by the symbol links not supported in some of the onie unzip.
We will enable after fixing the issue, see #10914
2022-05-26 09:39:48 +08:00
abdosi
0285bfe42e
[chassis] Fix issues regarding database service failure handling and mid-plane connectivity for namespace. (#10500)
What/Why I did:

Issue1: By setting up of ipvlan interface in interface-config.sh we are not tolerant to failures. Reason being interface-config.service is one-shot and do not have restart capability. 

Scenario: For example if let's say database service goes in fail state  then interface-services also gets failed because of dependency check but later database service gets restart but interface service will remain in stuck state and the ipvlan interface nevers get created.

Solution: Moved all the logic in database service from interface-config service which looks more align logically also since the namespace is created here and all the network setting (sysctl) are happening here.With this if database starts we recreate the interface.

Issue 2: Use of IPVLAN vs MACVLAN

Currently we are using ipvlan mode.  However above failure scenario is not handle correctly by ipvlan mode. Once the ipvlan interface is created and ip address assign to it and if we restart interface-config or database (new PR) service Linux Kernel gives error "Error: Address already assigned to an ipvlan device."  based on this:https://github.com/torvalds/linux/blob/master/drivers/net/ipvlan/ipvlan_main.c#L978Reason being if we do not do cleanup of ip address assignment (need to be unique for IPVLAN)  it remains in Kernel Database and never goes to free pool even though namespace is deleted. 

Solution: Considering this hard dependency of unique ip macvlan mode is better for us and since everything is managed by Linux Kernel and no dependency for on user configured IP address.

Issue3: Namespace database Service do not check reachability to Supervisor Redis Chassis   Server.

Currently there is no explicit check as we never do Redis PING from namespace to Supervisor Redis Chassis  Server. With this check it's possible we will start database and all other docker even though there is no connectivity and will hit the error/failure late in cycle

Solution: Added explicit PING from namespace that will check this reachability.

Issue 4:flushdb give exception when trying to accces Chassis Server DB over Unix Sokcet.

Solution: Handle gracefully via try..except and log the message.
2022-05-24 16:54:12 -07:00
Maxime Lorrillere
392899682f
[Arista] Add support for Wolverine linecards (#8887)
Add support for WolverineQCpu, WolverineQCpuMs, WolverineQCpuBk, WolverineQCpuBkMs

Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
2022-05-20 14:11:06 -07:00
Senthil Kumar Guruswamy
f37dd770cd
System Ready (#10479)
Why I did it
At present, there is no mechanism in an event driven model to know that the system is up with all the essential sonic services and also, all the docker apps are ready along with port ready status to start the network traffic. With the asynchronous architecture of SONiC, we will not be able to verify if the config has been applied all the way down to the HW. But we can get the closest up status of each app and arrive at the system readiness.

How I did it
A new python based system monitor tool is introduced under system-health framework to monitor all the essential system host services including docker wrapper services on an event based model and declare the system is ready. This framework gives provision for docker apps to notify its closest up status. CLIs are provided to fetch the current system status and also service running status and its app ready status along with failure reason if any.

How to verify it
"show system-health sysready-status" click CLI
Syslogs for system ready
2022-05-20 13:25:11 -07:00
Arun Saravanan Balachandran
f4b22f67a4
[initramfs]: SSD firmware upgrade in initramfs (#10748)
Why I did it
To upgrade SSD firmware in initramfs while rebooting from SONiC to SONiC and during NOS to SONiC migration.

How I did it
New option 'ssd-upgrader-part’ is introduced in grub command line, to indicate the partition and its filesystem type in which the SSD firmware updater is present. ‘ssd-upgrader-part’ syntax is ssd-upgrader-part=<partition>,<filesystem type>. Example: ssd-upgrader-part=/dev/sda8,ext4

A new initramfs script ‘ssd-upgrade’ is included in init-premount and it invokes the SSD firmware updater (ssd-fw-upgrade) present in the partition indicated by the boot option 'ssd-upgrader-part'

How to verify it
In SONiC, the SSD firmware updater is copied to “/host/” directory.
Fast-reboot is to be initiated with the ‘-u’ option ([scripts/fast-reboot] Add option to include ssd-upgrader-part boot option with SONiC partition sonic-utilities#2150)
After reboot, while booting into SONiC the SSD firmware updater will be executed in initramfs.
2022-05-12 08:11:02 -07:00
Marty Y. Lok
23f9126f59
[VoQ][config] Multiasic Supervisor card fails to load config_db#.json in chassis when system is reboot (#10106)
Supervisor card fails to load config_db#.json in chassis when system reboot. 
This is an intermittent issue, fixes #10105
2022-05-09 11:06:11 -07:00
xumia
15cf9b0d70
Reduce image size for lazy installation packages (#10775)
Why I did it
The image size is too large, when there are multiple lazy packages and multiple platforms. It is not necessary to keep the lazy installation packages in multiple copies.
For cisco image, the image size will reduce from 3.5G to 1.7G.

How I did it
Use symbol links to only keep one package for each of the lazy package.
Make a new folder fsroot/platform/common
Copy the lazy packages into the folder.
When using a package in each of the platform, such as x86_64-grub, x86_64-8800_rp-r0, x86_64-8201_on-r0, etc, only make a symbol link to the package in the common folder.
2022-05-09 08:26:09 -07:00
xumia
8ec8900d31
Support SONiC OpenSSL FIPS 140-3 based on SymCrypt engine (#9573)
Why I did it
Support OpenSSL FIPS 140-3, see design doc: https://github.com/Azure/SONiC/blob/master/doc/fips/SONiC-OpenSSL-FIPS-140-3.md.

How I did it
Install the fips packages.
To build the fips packages, see https://github.com/Azure/sonic-fips
Azure pipelines: https://dev.azure.com/mssonic/build/_build?definitionId=412

How to verify it
Validate the SymCrypt engine:

admin@sonic:~$ dpkg-query -W | grep openssl
openssl 1.1.1k-1+deb11u1+fips
symcrypt-openssl        0.1

admin@sonic:~$ openssl engine -v | grep -i symcrypt
(symcrypt) SCOSSL (SymCrypt engine for OpenSSL)
admin@sonic:~$
2022-05-06 07:21:30 +08:00
Junchao-Mellanox
681c24878b
Fix race condition between networking service and interface-config service (#10573)
Why I did it
The PR is aimed to fix a bug that mgmt port eth0 may loss IP even if user configured static IP of eth0. This is not a always reproduceable issue, the reproducing flow is like:

Systemd starts networking service, which runs a dhcp based configuration and assigned an ip from dhcp.
Systemd starts interface-config service who depends on networking service
Interface-config service runs command “ifdown –force eth0”, check line. but networking service is still running so that this line failed with error: “error: Another instance of this program is already running.”. This error is printed by ifupdown2 lib who is the main process of networking service. So, ifdown actually does not work here, the ip of eth0 is not down.
Interface-config service updates /etc/networking/interface to static configuration.
Interface-config service runs command “systemctl restart networking”. This command kills the previous networking related processes (log: networking.service: Main process exited, code=killed, status=15/TERM), and try to reconfigure the ip address with static configuration. But it detects that the configured IP and the existing IP are the same, and it does not really configure the ip to kernel. Hence, the ip is still getting from dhcp. (this could be a bug of ifupdown2: previous ip is from dhcp, new ip is a static ip, it treats them as same instead of re-configuring the IP)
When the lease of the ip expires, the ip of eth0 is removed by kernel and the issue reproduces.
The issue is not always reproduceable because networking service usually runs fast so that it won't hit step#3.

How I did it
Check networking service state before running "ifdown –force eth0", wait for it done if it is activating.

How to verify it
Manual test.
2022-05-05 15:21:44 -07:00
shlomibitton
4ec3af86af
[Fastboot] Delay PMON service for better fastboot performance (#10567)
- Why I did it
Profiling the system state on init after fast-reboot during create_switch function execution, it is possible to see few python scripts running at the same time.
This parallel execution consume CPU time and the duration of create_switch is longer than it should be.
Following this finding, and the motivation to ensure these services will not interfere in the future, PMON is delayed in 90 seconds until the system finish the init flow after fastboot.

- How I did it
Add a timer for PMON service.
Exclude for MLNX platform the start trigger of PMON when SYNCD starts in case of fastboot.
Copy the timer file to the host bin image.

- How to verify it
Run fast-reboot on MLNX platform and observe faster create_switch execution time.
2022-05-02 10:44:17 +03:00
shlomibitton
1d84e0d7df
[Fastboot] Delay LLDP service for better fastboot performance (#10568)
- Why I did it
Profiling the system state on init after fast-reboot during create_switch function execution, it is possible to see few python scripts running at the same time.
This parallel execution consume CPU time and the duration of create_switch is longer than it should be.
Following this finding, and the motivation to ensure these services will not interfere in the future, LLDP is delayed in 90 seconds until the system finish the init flow after fastboot.

- How I did it
Add a timer for LLDP service.
Copy the timer file to the host bin image.

- How to verify it
Run fast-reboot on MLNX platform and observe faster create_switch execution time.
This PR is dependent on PR: #10567
2022-04-28 10:35:14 +03:00
ganglv
9d7387a18e
[sonic-host-services]: Fix import and invalid path (#10660)
Why I did it
Can not start sonic-hostservice

How I did it
Install python3-dbus and systemd-python, and replace invalid path

How to verify it
Start the service with below commands:
sudo systemctl start sonic-hostservice
sudo systemctl status sonic-hostservice

Signed-off-by: Gang Lv ganglv@microsoft.com
2022-04-27 07:14:51 +08:00
Saikrishna Arcot
64187a1b15
Remove SSH host keys after installing the custom version of sshd (#10633)
* Remove SSH host keys after installing the custom version of sshd

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>

* Use an override for for sshd instead of overwriting the service file

Don't overwrite upstream's .service file, and instead use an override
file for making sure the host key(s) are generated.

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
2022-04-25 10:38:52 -07:00
bingwang-ms
3fc3259a35
Define qos map AZURE_TUNNEL for QoS remapping of tunnel traffic (#10565)
* Add AZURE_TUNNEL map

Signed-off-by: bingwang <wang.bing@microsoft.com>
2022-04-25 15:06:10 +08:00
yozhao101
e24fe9bc60
[Monit] Fix the issue which shows Monit can not reset its counter. (#10288)
Signed-off-by: Yong Zhao <yozhao@microsoft.com>

Why I did it
This PR aims to fix the Monit issue which shows Monit can't reset its counter when monitoring memory usage of telemetry container.

Specifically the Monit configuration file related to monitoring memory usage of telemetry container is as following:

  check program container_memory_telemetry with path "/usr/bin/memory_checker telemetry 419430400"
      if status == 3 for 10 times within 20 cycles then exec "/usr/bin/restart_service telemetry"
If memory usage of telemetry container is larger than 400MB for 10 times within 20 cycles (minutes), then it will be restarted.
Recently we observed, after telemetry container was restarted, its memory usage continuously increased from 400MB to 11GB within 1 hour, but it was not restarted anymore during this 1 hour sliding window.

The reason is Monit can't reset its counter to count again and Monit can reset its counter if and only if the status of monitored service was changed from Status failed to Status ok. However, during this 1 hour sliding window, the status of monitored service was not changed from Status failed to Status ok.

Currently for each service monitored by Monit, there will be an entry showing the monitoring status, monitoring mode etc. For example, the following output from command sudo monit status shows the status of monitored service to monitor memory usage of telemetry:

    Program 'container_memory_telemetry'
         status                             Status ok
         monitoring status          Monitored
         monitoring mode          active
         on reboot                      start
         last exit value                0
         last output                    -
         data collected               Sat, 19 Mar 2022 19:56:26
Every 1 minute, Monit will run the script to check the memory usage of telemetry and update the counter if memory usage is larger than 400MB. If Monit checked the counter and found memory usage of telemetry is larger than 400MB for 10 times
within 20 minutes, then telemetry container was restarted. Following is an example status of monitored service:

    Program 'container_memory_telemetry'
         status                             Status failed
         monitoring status          Monitored
         monitoring mode          active
         on reboot                      start
         last exit value                0
         last output                    -
         data collected               Tue, 01 Feb 2022 22:52:55
After telemetry container was restarted. we found memory usage of telemetry increased rapidly from around 100MB to more than 400MB during 1 minute and status of monitored service did not have a chance to be changed from Status failed to Status ok.

How I did it
In order to provide a workaround for this issue, Monit recently introduced another syntax format repeat every <n> cycles related to exec. This new syntax format will enable Monit repeat executing the background script if the error persists for a given number of cycles.

How to verify it
I verified this change on lab device str-s6000-acs-12. Another pytest PR (Azure/sonic-mgmt#5492) is submitted in sonic-mgmt repo for review.
2022-04-20 18:08:06 -07:00
Samuel Angebault
fb147764b5
[Arista] Fix arista-net initramfs hook (#10624)
The interface renaming logic fails if one interface is missing.
Because of the `set -e` the whole initramfs hook would abort early on
error.
This change fixes the current behavior to make sure missing interfaces
are properly skipped and ensure existing interface are renamed.
2022-04-20 10:03:05 -07:00
Junhua Zhai
128d762af3
[gearbox] Add peer gbsyncd for swss if gearbox exists (#10504)
Fix the issues #10501 and #9733

If having gearbox, we need:
    * add gbsyncd as a peer since swss also has dependency on gbsyncd
    * add service gbsyncd to FEATURE table if it is missing
2022-04-20 19:02:49 +08:00
kellyyeh
2a516a7763
[dhcp_relay] Enable dhcp_relay on EPMS, MgmtTsTor, MgmtToRRouter and BackEndToRRouter (#10474) 2022-04-15 18:01:24 -07:00
Yakiv Huryk
d9117d9411
[Mellanox][asan] add address sanitizer support for syncd (#10266)
Why I did it
To support address sanitizer for Mellanox syncd

How I did it
/var/log/asan is mapped for syncd container (the same as for swss)
container stop() has a timeout (60s) for syncd (the same as for swss)
This is so libasan has enough time to generate a report.
added ASAN's log path to Mellanox syncd supervisord.conf
added "asan: yes" to sonic_version.yml
How to verify it
Added artificial memory leaks
Compiled with ENABLE_ASAN=y
Installed the image on DUT
Rebooted the DUT
Verified that /var/log/asan/syncd-asan.log contains the leaks

Signed-off-by: Yakiv Huryk <yhuryk@nvidia.com>
2022-04-14 15:00:32 -07:00
Saikrishna Arcot
12ebe3ffa0
Run tune2fs during initramfs instead of image install (#10536)
If it is run during image install, it's not guaranteed that the
installation environment will have tune2fs available. Therefore, run it
during initramfs instead.

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
2022-04-12 16:24:13 -07:00
byu343
f7a6553933
[docker-syncd]: Add optional shm-size to syncd container (#10516)
Why I did it
In the bringup of tomahawk4/trident4, we realized that such chips need a larger size of /dev/shm in syncd container, so we added the option --shm-size to the docker create for syncd. The default value for shm-size is 64m; after this change, people can add SYNCD_SHM_SIZE=128m to platform_env.conf to change it to 128m.

How to verify it
We verified that after this change, 1) on existing platforms without platform_env.conf, the size of /dev/shm in syncd container (df -h | grep shm) is still the default 64M; 2) after we add SYNCD_SHM_SIZE=128m to platform_env.conf, /dev/shm in syncd becomes 128M.
2022-04-09 10:47:18 -07:00
Vivek R
ed14eb5263
[interfaces-config] "main exception: cannot find interfaces: eth0" error log avoided (#10463)
- Why I did it
Fixes #9628
During bootup, this error log is seen

Dec 22 04:26:29 sonic interfaces-config.sh[2546]: error: main exception: cannot find interfaces: eth0 (interface was probably never up ?)
This is of non-functional nature and doesn't affect the flow.

- How I did it
Dont take the ifdown if not needed

- How to verify it
Verified during reboot. Log did not appear and IP was acquired on eth0 as expected

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-04-06 16:59:47 +03:00
bingwang-ms
b9dd1df372
Update qos config to clear queues for bounced back traffic (#10176)
* Update qos config to clear queues for bounced back traffic

Signed-off-by: bingwang <bingwang@microsoft.com>
2022-04-05 22:32:25 +08:00
judyjoseph
8e642848c2
Introduce the asic_subtype field for adding the sub platform variants. (#10235)
* Introduce the asic_subtype field for adding the sub platform variants. 
   It uses the value of TARGET_MACHINE variable in slave.mk.
2022-03-28 11:22:32 -07:00
Santhosh Kumar T
e2502edefd
Refactoring DELL platform init to reduce rc.local processing time porting changes in master (#10318)
Why I did it
To reduce the processing time of rc.local, refactoring s6100 platform initialization.
Porting changes from 202012 branch [202012] Refactoring DELL platform init to reduce rc.local processing time #10171
2022-03-24 11:14:37 -07:00
xumia
e9ac13678d
[Build]: Fix armhf mirrors not existing issue (#10312)
Why I did it
[Build]: Fix armhf mirrors not existing issue
The mirror endpoint debian-archive.trafficmanager.net does not support armhf, change to use deb.debian.org and security.debian.org.
2022-03-22 15:24:15 +08:00
Kostiantyn Yarovyi
bf4ab4a338
[Barefoot][Syncd] restart of the interface for cleaning txquee through which communication takes place between Sonic and openBMC (#9941)
Why I did it
improvement of starting barefoot SDK

How I did it
restart of the interface for cleaning txquee through which communication takes place between Sonic and openBMC

How to verify it
run sonic autorestart tests
2022-03-21 10:07:20 -07:00
Samuel Angebault
e4b507fa03
[Arista] rename management interface in initrd (#9856)
On some products the pci enumeration adds randomness into which nic gets
initialized first.
Because SONiC doesn't use deterministic interface naming but instead old
style interface naming, this leads to eth0 not always being the
management port.
To make sure eth0 is always the management port (SONiC expectation)
rename the interfaces in the initramfs for Arista products.
2022-03-21 17:55:23 +05:30
xumia
1017ee6002
[Build]: Use one debian mirror config (#10274)
Why I did it
Use one debian mirror config.
The empty config in https://github.com/Azure/sonic-buildimage/blob/master/files/image_config/apt/sources.list overrides the file https://github.com/Azure/sonic-buildimage/blob/master/files/apt/sources.list.amd64 (armhf/arm64), it does not make sense.
All the content in files/image_config/apt is no use, any one wants to add mirror config, please add in files/apt.

How I did it
Remove files/image_config/apt and the reference.
2022-03-21 16:47:20 +08:00
Saikrishna Arcot
5617b1ae3e
Image disk space reduction (#10172)
# Why I did it

Reduce the disk space taken up during bootup and runtime.

# How I did it

1. Remove python package cache from the base image and from the containers.
2. During bootup, if logs are to be stored in memory, then don't create the `var-log.ext4` file just to delete it later during bootup.
3. For the partition containing `/host`, don't reserve any blocks for just the root user. This just makes sure all disk space is available for all users, if needed during upgrades (for example).


* Remove pip2 and pip3 caches from some containers

Only containers which appeared to have a significant pip cache size are
included here.

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>

* Don't create var-log.ext4 if we're storing logs in memory

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>

* Run tune2fs on the device containing /host to not reserve any blocks for just the root user

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
2022-03-15 18:12:49 -07:00
Stepan Blyshchak
18d00dfbe7
[teamd.sh] kill teamd docker on warm shutdown for faster shutdown (#10219)
This can save 6 sec for teamd LAG restoration - the time between:

```
Mar  9 13:51:10.467757 r-panther-13 WARNING teamd#teamd_PortChannel1[28]: Got SIGUSR1.
Mar  9 13:52:33.310707 r-panther-13 INFO teamd#teamd_PortChannel1[27]: carrier changed to UP
```

- Why I did it
Optimize warm boot. Specifically reduce the time needed for LAG restoration.

- How I did it
Kill teamd docker after graceful shutdown of teamd processes.

- How to verify it
Run warm reboot.

Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
2022-03-15 09:20:36 +02:00
xumia
0243ed9538
[build]: Fix marvell-armhf build hung issue (#10156) (#10229)
Why I did it
The marvel-armhf build is hung, it does not exit after waiting for a long time.
It is caused by the process /etc/entropy.py which is started by the postinst script in target/debs/buster/sonic-platform-nokia-7215_1.0_armhf.deb
2022-03-15 10:03:54 +08:00
Saikrishna Arcot
d7c3ce0045
Specify the filesystem type when mounting to /host (#10169)
When mounting the partition that contains `/host` during initramfs, the
mount binary available there (coming from busybox) tries each filesystem
in `/proc/filesystems` and sees which one succeeds. During this time,
there may be some error messages logged into dmesg because some of the
incorrect filesystems failed to mount the partition.

Specify the filesystem type explicitly so that initramfs knows it's that
type, and we know what filesystem will always get used there.

Fixes #9998

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
2022-03-14 11:34:02 -07:00
Stepan Blyshchak
2919b4820f
[hostcfgd] record feature state in STATE DB (#9842)
- Why I did it
To implement blocking feature state change.

- How I did it
Record the actual feature state in STATE DB from hostcfg.

- How to verify it
UT + verification by running on the switch and checking STATE DB.

Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
2022-03-14 13:45:27 +02:00
xumia
eea3cc7ad1
[Build]: only install grpc in amd64 (#10212)
[Build]: only install grpc in amd64
Unblock marvell-armhf build.
2022-03-14 13:41:37 +08:00
Samuel Angebault
8d419ca2c5
[Arista] Remove arista.log from rsyslog default logrotate (#9731)
Why I did it
In parallel of this change Arista added a custom logrotate configuration as part of its driver library.
Having 2 logrotate configuration for the same log file triggers an issue.

Fixes aristanetworks/sonic#38

How I did it
Arista merged a few changes in sonic-buildimage which added a logrotate configuration aristanetworks/sonic@e43c797
It is therefore the right path to remove the arista.log line from the logrotate.d/rsyslog configuration.

How to verify it
Logrotate works without any error message, arista log rotation happens and arista daemons still append logs once file was truncated.
2022-03-11 08:09:07 -08:00
xumia
9cdf81230b
[Build]: Fix /proc not mounted issue (#10164)
[Build]: Fix /proc not mounted issue
2022-03-11 09:23:37 +08:00
Song Yuan
01798447ab
[Chassis][QoS template] Skip configuring buffer and QoS config on recirc ports (#7869)
* Added test case to verify the template changes.
2022-03-09 16:04:36 -08:00
Kebo Liu
fe0a7693f4
[smartmontools] Install smartmontools with apt-get and upgrade it to 7.2-1 (#10087)
Why I did it
Smartmontools 6.6 has an issue with reading SMART info of nvme SSD
Smartmontools can be installed with apt-get, no need to build and install

How I did it
Use apt-get to install smartmontools 7.2-1
Remove previous make files for smartmontools 6.6

How to verify it
verify with "smartctl" can read out correct SMART info on NVME ssd.
verify "show platform ssdhealth" can still work

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-03-07 09:39:33 -08:00
Marty Y. Lok
c40f04f0e2
[chassis][supervisor]monit container-checker failed due to unexpected "database-chassis" docker running #9042 (#9043)
Why I did it
Fixed the monit container_checker fails due to unexpected "database-chassis" docker running on Supervisor card in the VOQ chassis. fixes #9042

How I did it
Added database-chassis to the always running docker list if platform is supervisor card.

How to verify it
Execute the CLI command "sudo monit status container_checker"


Signed-off-by: mlok <marty.lok@nokia.com>
2022-03-03 17:56:08 -08:00
Aravind Mani
1740beb1f2
[sonic-cfggen]: Fix sonic-cfggen build failures for armhf (#10132)
Why I did it
amrhf build fails while building sonic-config-engine whl package
https://dev.azure.com/mssonic/be1b070f-be15-4154-aade-b1d3bfb17054/_apis/build/builds/77089/logs/9

The reason for the failure is due to the fact that there is a new line generated at the top of the file in buffer config test cases while building for broadcom based platform and this issue is not seen in Marvell based platforms.

How I did it
Removed the new line for all the buffer test cases as there is no need to add it and accordingly changed the buffer_config.j2 where the new line is generated.
2022-03-02 13:06:20 -08:00
Lawrence Lee
a50d1f1fc8
[write_standby]: Increase timeout to 60s (#10065)
- Avoid scenarios where script times out before orchagent can establish IPinIP tunnel

Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
2022-02-24 14:55:45 -08:00
wenyiz2021
2d0b063191
Update container_checker for multi-asic devices when state is 'always_enabled' (#10067)
* Update container_checker for multi-asic devices 

Update container_checker for multi-asic devices to add database containers in always_running_containers. 
Previous change was made for single-asic, and that database containers were not considered as feature when writing to state_db.

* Update container_checker

Update an indent
2022-02-23 18:06:30 -08:00
vmittal-msft
bc1dfea619
Updated traffic scheduler settings for HWSKUs : DellEMC-Z9332f-O32 and DellEMC-Z9332f-M-O16C64 (#9828) 2022-02-23 17:22:41 -08:00
Stepan Blyshchak
fb752a4ae5
[rsyslog.j2] fix typo in VAR_LOG_SIZE_KB (#9954)
This issue causes negative threshold value and thus deleting log files even when there is enough space.

This issue causes negative threshold value and thus deleting log files even when there is enough space.

- Why I did it
To fix an issue when log files get deleted even if there is enough space.

- How I did it
Fixed an typo.

- How to verify it
Run the portion of the script that calculates threshold, see that the threshold is calculated correctly.

Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
2022-02-17 10:16:44 +02:00
byu343
155220be9b
Support multi-asic on macsec container (#9921)
This change enables the support of running multiple macsec containers, each for one ASIC.
2022-02-13 22:45:24 -08:00
Oleksandr Ivantsiv
25a0ce5eb1
[asan] Add address sanitizer support. (#9857)
Implement infrastructure that allows enabling address sanitizer
for docker containers. Enable address sanitizer for SWSS container.

- Why I did it
To add a possibility to compile SONiC applications with address sanitizer (ASAN).
ASAN is a memory error detector for C/C++. It finds:
1. Use after free (dangling pointer dereference)
2. Heap buffer overflow
3. Stack buffer overflow
4. Global buffer overflow
5. Use after return
6. Use after the scope
7. Initialization order bugs
8. Memory leaks

- How I did it
By adding new ENABLE_ASAN configuration option.

- How to verify it
By default ASAN is disabled and the SONiC image is not affected.
When ASAN is enabled it inspects all allocation, deallocation, and memory usage that the application does in run time. To verify whether the application has memory errors tests that trigger memory usage of the application should be run. Ideally, the whole regression tests should be run. Memory leaks reports will be placed in /var/log/asan/ directory of SONiC host OS.

Signed-off-by: Oleksandr Ivantsiv <oivantsiv@nvidia.com>
2022-02-09 13:29:18 +02:00
Prince George
ff14aebef9
Close console session due to user inactivity (#9890)
Signed-off-by: Prince George <prgeor@microsoft.com>
2022-02-02 09:41:21 +05:30
tbgowda
4e32f85a31
Enable SAI_SWITCH_ATTR_UNINIT_DATA_PLANE_ON_REMOVAL attribute (#9419)
Why I did it
Fixes #8980 partly.

The corresponding changes in sonic-sairedis is here :
Azure/sonic-sairedis#975

How I did it
Include changes from both repos and build an image for verification.

How to verify it
Trigger fast-reboot with the changes, see the attribute SAI_SWITCH_ATTR_UNINIT_DATA_PLANE_ON_REMOVAL being set at the SAI level.

Signed-off-by: Thushar Gowda <24815472+tbgowda@users.noreply.github.com>
2022-02-01 08:44:17 -08:00
Alexander Allen
8a07af95e5
[Mellanox] Modified Platform API to support all firmware updates in single boot (#9608)
Why I did it
Requirements from Microsoft for fwutil update all state that all firmwares which support this upgrade flow must support upgrade within a single boot cycle. This conflicted with a number of Mellanox upgrade flows which have been revised to safely meet this requirement.

How I did it
Added --no-power-cycle flags to SSD and ONIE firmware scripts
Modified Platform API to call firmware upgrade flows with this new flag during fwutil update all
Added a script to our reboot plugin to handle installing firmwares in the correct order with prior to reboot
How to verify it
Populate platform_components.json with firmware for CPLD / BIOS / ONIE / SSD
Execute fwutil update all fw --boot cold
CPLD will burn / ONIE and BIOS images will stage / SSD will schedule for reboot
Reboot the switch
SSD will install / CPLD will refresh / switch will power cycle into ONIE
ONIE installer will upgrade ONIE and BIOS / switch will reboot back into SONiC
In SONiC run fwutil show status to check that all firmware upgrades were successful
2022-01-24 00:56:38 -08:00
dflynn-Nokia
b6939b9927
[firsttime boot] suppress error message on platforms not supporting kdump (#9521)
Why I did it
Eliminate benign firsttime boot error reported when running on platforms that do not support kdump.

How I did it
Change rc.local to check for presence of the file /etc/default/kdump-tools before referencing it.

How to verify it
Install a new image on an armhf or arm64 platform and check for a failed reference to /etc/default/kdump-tools on firsttime boot.
2022-01-20 18:27:10 -08:00
Shyam
20f32dc072
Added gbsyncd infra for multi-ASIC, multi-PHY mode (#9722)
- External PHY is managed via gearbox (gbsybcd docker container) in SONiC
  - Enhanced 'External PHY management' from SONiC's single-ASIC environment to multi-ASIC
  - Enhanced gbsyncd docker container from single Namespace to multi-Namspace mode
  - Added gbsyncd.service.j2 on per_namespace basis.
  - Each namepace/ASIC now to have its unique gbsyncd<ASIC#> docker container with its
    own Gearbox table, redis-DB

Signed-off-by: Shyam Kumar <shyakuma@cisco.com>
2022-01-21 10:08:16 +08:00
Alexander Allen
5f596aef63
[pmon] Move smartctl from pmon to host (#9607)
Why I did it
Need to be able to run smartctl when pmon docker is not running.

How I did it
Removed the pmon dependency for pmon as well as the command wrapper and added it to the debian-extension.

How to verify it
Stop pmon
Run smartctl from the host and verify it runs without error
2022-01-19 10:53:10 -08:00