- Enable thermalctld support for our platforms
- Fix Chassis.get_num_sfp which had an off by one
- Implement read_eeprom and write_eeprom in SfpBase
- Refactor of Psus and PsuSlots. Psus they are now detected and metadata reported
- Improvements to modular support
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
The `get_serial_number()` method in the ChassisBase and ModuleBase classes was redundant, as the `get_serial()` method is inherited from the DeviceBase class. This method was removed from the base classes in sonic-platform-common and the submodule was updated in https://github.com/Azure/sonic-buildimage/pull/5625.
This PR aligns the existing vendor platform API implementations to remove the `get_serial_number()` methods and ensure the `get_serial()` methods are implemented, if they weren't previously.
Note that this PR does not modify the Dell platform API implementations, as this will be handled as part of https://github.com/Azure/sonic-buildimage/pull/5609
We want to let Monit to unmonitor the processes in containers which are disabled in `FEATURE` table such that
Monit will not generate false alerting messages into the syslog.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
- Merge chassis codebase upstream
- Add support for Otterlake supervisor
- Add support for NorthFace and Camp chassis
- Add support for Eldridge, Dragonfly and Brooks fabrics
- Add support for Clearwater2 and Clearwater2Ms linecards
- Add new arista Cli to power on/off cards
- Add new arista show Cli to inspect supervisor, chassis, fabrics and linecards
- Finish the refactor of the smbus backend (huge performance enhencement)
- Split scd-hwmon kernel module in multiple source files
- Add new scd-uart driver to manage linecard consoles within a chassis
- Bootstrap of thermal platform API implementation
- Fix psud led error message
- Fix fan led color on Smartsville
When stopping the swss, pmon or bgp containers, log messages like the following can be seen:
```
Aug 23 22:50:43.789760 sonic-dut INFO swss#supervisord 2020-08-23 22:50:10,061 ERRO pool dependent-startup event buffer overflowed, discarding event 34
Aug 23 22:50:43.789760 sonic-dut INFO swss#supervisord 2020-08-23 22:50:10,063 ERRO pool dependent-startup event buffer overflowed, discarding event 35
Aug 23 22:50:43.789760 sonic-dut INFO swss#supervisord 2020-08-23 22:50:10,064 ERRO pool dependent-startup event buffer overflowed, discarding event 36
Aug 23 22:50:43.789760 sonic-dut INFO swss#supervisord 2020-08-23 22:50:10,066 ERRO pool dependent-startup event buffer overflowed, discarding event 37
```
This is due to the number of programs in the container managed by supervisor, all generating events at the same time. The default event queue buffer size in supervisor is 10. This patch increases that value in all containers in order to eliminate these errors. As more programs are added to the containers, we may need to further adjust these values. I increased all buffer sizes to 25 except for containers with more programs or templated supervisor.conf files which allow for a variable number of programs. In these cases I increased the buffer size to 50. One final exception is the swss container, where the buffer fills up to ~50, so I increased this buffer to 100.
Resolves https://github.com/Azure/sonic-buildimage/issues/5241
when parallel build is enabled, both docker-fpm-frr and docker-syncd-brcm
is built at the same time, docker-fpm-frr requires swss which requires to
install libsaivs-dev. docker-syncd-brcm requires syncd package which requires
to install libsaibcm-dev.
since libsaivs-dev and libsaibcm-dev install the sai header in the same
location, these two packages cannot be installed at the same time. Therefore,
we need to serialize the build between these two packages. Simply uninstall
the conflict package is not enough to solve this issue. The correct solution
is to have one package wait for another package to be uninstalled.
For example, if syncd is built first, then it will install libsaibcm-dev.
Meanwhile, if the swss build job starts and tries to install libsaivs-dev,
it will first try to query if libsaibcm-dev is installed or not. if it is
installed, then it will wait until libsaibcm-dev is uninstalled. After syncd
job is finished, it will uninstall libsaibcm-dev and swss build job will be
unblocked.
To solve this issue, _UNINSTALLS is introduced to uninstall a package that
is no longer needed and to allow blocked job to continue.
Signed-off-by: Guohan Lu <lguohan@gmail.com>
make swss build depends only on libsairedis instead of syncd. This allows to build swss without depending
on vendor sai library.
Currently, libsairedis build also buils syncd which requires vendor SAI lib. This makes difficult to build
swss docker in buster while still keeping syncd docker in stretch, as swss requires libsairedis which also
build syncd and requires vendor to provide SAI for buster. As swss docker does not really contain syncd
binary, so it is not necessary to build syncd for swss docker.
* [submodule]: update sonic-sairedis
* ccbb3bc 2020-06-28 | add option to build without syncd (HEAD, origin/master, origin/HEAD) [Guohan Lu]
* 4247481 2020-06-28 | install saidiscovery into syncd package [Guohan Lu]
* 61b8e8e 2020-06-26 | Revert "sonic-sairedis: Add support to sonic-sairedis for gearbox phys (#624)" (#630) [Danny Allen]
* 85e543c 2020-06-26 | add a README to tests directory to describe how to run 'make check' (#629) [Syd Logan]
* 2772f15 2020-06-26 | sonic-sairedis: Add support to sonic-sairedis for gearbox phys (#624) [Syd Logan]
Signed-off-by: Guohan Lu <lguohan@gmail.com>
**- Why I did it**
Initially, the critical_processes file contains either the name of critical process or the name of group.
For example, the critical_processes file in the dhcp_relay container contains a single group name
`isc-dhcp-relay`. When testing the autorestart feature of each container, we need get all the critical
processes and test whether a container can be restarted correctly if one of its critical processes is
killed. However, it will be difficult to differentiate whether the names in the critical_processes file are
the critical processes or group names. At the same time, changing the syntax in this file will separate the individual process from the groups and also makes it clear to the user.
Right now the critical_processes file contains two different kind of entries. One is "program:xxx" which indicates a critical process. Another is "group:xxx" which indicates a group of critical processes
managed by supervisord using the name "xxx". At the same time, I also updated the logic to
parse the file critical_processes in supervisor-proc-event-listener script.
**- How to verify it**
We can first enable the autorestart feature of a specified container for example `dhcp_relay` by running the comman `sudo config container feature autorestart dhcp_relay enabled` on DUT. Then we can select a critical process from the command `docker top dhcp_relay` and use the command `sudo kill -SIGKILL <pid>` to kill that critical process. Final step is to check whether the container is restarted correctly or not.
**- Why I did it**
After discussed with Joe, we use the string "/usr/bin/syncd\s" in Monit configuration file to monitor
syncd process on Broadcom and Mellanox. Due to my careless, I did not find this bug during the
previous testing. If we use the string "/usr/bin/syncd" in Monit configuration file to monitor the
syncd process, Monit will not detect whether syncd process is running or not.
If we ran the command `sudo monit procmactch “/usr/bin/syncd”` on Broadcom, there will be three
processes in syncd container which matched this "/usr/bin/syncd": `/bin/bash /usr/bin/syncd.sh
wait`, `/usr/bin/dsserve /usr/bin/syncd –diag -u -p /etc/sai.d/sai.profile` and `/usr/bin/syncd –diag -
u -p /etc/sai.d/said.profile`. Monit will select the processes with the highest uptime (at there
`/bin/bash /usr/bin/syncd.sh wait`) to match and did not select `/usr/bin/syncd –diag -u -p
/etc/sai.d/said.profile` to match.
Similarly, On Mellanox Monit will also select the process with the highest uptime (at there
`/bin/bash /usr/bin/syncd.sh wait`) to match and did not select `/usr/bin/syncd –diag -u -p
/etc/sai.d/said.profile` to match.
That is why Monit is unable to detect whether syncd process is running or not if we use the string “/usr/bin/syncd” in Monit configuration file. If we use the string "/usr/bin/syncd\s" in Monit configuration file, Monit can filter out the process `/bin/bash /usr/bin/syncd.sh wait` and thus can correctly monitor the syncd process.
**- How I did it**
**- How to verify it**
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
- Sensor and Fan information added to primary platforms for thermal API.
- Refactors involving better abstractions, code reuse and dead code removal.
- Improvements to the diag capabilities
- Pylintrc added to improve code quality. Will become fatal at a later time.
Co-authored-by: Baptiste Covolato <baptiste@arista.com>
- Add Makefile rules to build debug containers for SWI images
- Fix some platform API implementation for xcvrd and thermalctld
- Improvements to arista diag command
- Miscellaneous refactors
Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
- build SONIC_STRETCH_DOCKERS in sonic-slave-stretch docker
- build image related module in sonic-slave-buster docker.
This includes all kernels modules and some packages
Signed-off-by: Guohan Lu <lguohan@gmail.com>
This patch upgrade the kernel from version
4.9.0-9-2 (4.9.168-1+deb9u3) to 4.9.0-11-2 (4.9.189-3+deb9u2)
Co-authored-by: rajendra-dendukuri <47423477+rajendra-dendukuri@users.noreply.github.com>