Calculate pool size in t1 as 24 * downlink port + 8 * uplink port
- Take both port and peer MTU into account when calculating headroom
- Worst case factor is decreased to 50%
- Mellanox-SN2700-C28D8 t0, assume 48 * 50G/5m + 8 * 100G/40m ports
- Mellanox-SN2700 (C32)
- t0: 16 * 100G/5m + 16 * 100G/40m
- t1: 16 * 100G/40m + 16 * 100G/300m
Signed-off-by: Stephen Sun <stephens@mellanox.com>
Co-authored-by: Stephen Sun <stephens@mellanox.com>
The new feature system health support a platform based configuration file. Add configuration files for all Mellanox platform.
Add a configuration file for SN2700, other platform will use a soft link to it.
Add related files to the device folder:
buffer config templates
pg lookup profile
port_config.ini
sai profile
sensor conf
plugins
Co-authored-by: Stephen Sun <stephens@mellanox.com>
* Change port index in port_config.ini to 1-based
* Add default port index to port_config.ini, change platform plugins to accept 1-based port index
* fix port index in sfp_event.py