- Why I did it
Need to remove old static configs from sai.profile files.
New implementation: Azure/sonic-swss#1959
New configuration: #9658
- How I did it
Remove SAI_VXLAN_SRCPORT_RANGE_ENABLE=1 lines from files per HWSKU
- How to verify it
When static config is removed following test will fail (src port will be in range 0-255)
py.test vxlan/test_vnet_vxlan.py --inventory "../ansible/inventory, ../ansible/veos" --host-pattern (testbed)-t0 --module-path ../ansible/library/ --testbed (testbed)-t0 --testbed_file ../ansible/testbed.csv --allow_recover --assert plain --log-cli-level info --show-capture=no -ra --showlocals --disable_loganalyzer --skip_sanity --upper_bound_udp_port 65535 --lower_bound_udp_port 64128
- Why I did it
To create SDK dump on Mellanox devices when SDK event has occurred.
- How I did it
Set the SKUs keys needed to initialize the feature in SAI.
- How to verify it
Simulate SDK event and check that dump is created in the expected path.
sai_xml contains info about port splits, previously it simply linked to the MSN3800 sai xml, which does not have splits. New version describes splits and speeds according to Mellanox-SN3800-D112-C8 SKU.
Practically it can cause port recreation on SAI init.
Signed-off-by: Mykola Faryma <mykolaf@mellanox.com>