Revert "Move /var/log to RAM for Mellanox SN2700, Nokia 7215 and Dell S6100 (#15077)" (#16775) (#16886) 2023-10-14 15:38:25 +08:00
vmittal-msft
9ffa4bdfff [nokia]: Updated total headroom pool size to accommodate 100G ports on T2 uplinks (#16690)
Microsoft ADO (25266920)

sonic-mgmt xoff test was failing for [100g,120km]. Needed to update total headroom pool size when 100G line card is used as T2 uplink.

This size was calculated assuming 100g is used for downlink so cable length was 2km whereas it can also be used for uplink (cable length - 120km). so we need to do calculation based on 120km not 2km. Although it will be some wastage for 2km scenario but it should cover both cases.
2023-09-27 12:32:28 +08:00
mssonicbld
74dbafe728
[Nokia-IXR7250E] Modify the platform_ndk.json for Nokia-IXR7250E platform (#16355) (#16382)
Signed-off-by: mlok <marty.lok@nokia.com>
Co-authored-by: Marty Y. Lok <76118573+mlok-nokia@users.noreply.github.com>
2023-09-01 20:12:14 -07:00
mssonicbld
88d692f987
[Nokia][DeviceData] Update the Nokia platform IXR-7250E device data (#16028) (#16381)
Why I did it
Update the platform_reboot of Nokia Platform IXR-7250E-36x400G to displays the correct reboot-cause history when reboot from supervisor card.

Work item tracking
Microsoft ADO (number only):
How I did it
Modify the platform_reboot script to copy the correct reboo-cause.txt file from NDK to the /host/reboot-cause directory at the down cycle when the reboot is issued from Supervisor (for both reboot right after install a new image and normal reboot)

Signed-off-by: mlok <marty.lok@nokia.com>
Co-authored-by: Marty Y. Lok <76118573+mlok-nokia@users.noreply.github.com>
2023-09-01 16:19:22 -07:00
vmittal-msft
134a22221c
Update CPU transmitted packets to queue 7 for chassis (#16349) 2023-08-31 08:57:02 -07:00
Pavan-Nokia
5d4a201453
[armhf][Nokia-7215]Add HWSKU files for new SAI (#16175)
Add new easy bringup (EZB) files for new SAI 1.10.2-5
2023-08-18 11:23:23 -07:00
mssonicbld
a5eda5aaa8
Updated PG headroom settings for 40g port speed (#16038) (#16177)
Co-authored-by: vmittal-msft <46945843+vmittal-msft@users.noreply.github.com>
2023-08-17 08:40:00 -07:00
mssonicbld
365afbb3f0
Move /var/log to RAM for Mellanox SN2700, Nokia 7215 and Dell S6100 (#15077) (#15804) 2023-07-13 05:01:14 +08:00
Marty Y. Lok
e8e8c019c2
[Nokia-IXR7250E][Devicedata] update the device data for Nokia IXR7250E platform (#15605)
Signed-off-by: mlok <marty.lok@nokia.com>
(cherry picked from commit 478ba478f5)
2023-06-23 15:41:46 -07:00
vmittal-msft
41cd22d04e
Updated default ECN settings for T2 chassis (#15541)
* Updated default ECN settings for T2 chassis (#14388)

Why I did it
Update ECN settings for T2 chassis

How I did it
Updated qos config file to load these settings during switch bootup

How to verify it
Verified on line card on T2 chassis

* Fix for test failures

* Test case failures

* test case fix
2023-06-22 08:17:45 -07:00
vmittal-msft
723c508a30
Update PG headroom settings ports based on port speed/cable length (#15287)
Why I did it
Update cable length for uplink/downlink ports for chassis and and update PG/pool headroom size accordingly.

Work item tracking
17880812

How I did it
Updated cable length as well as buffer config in HWSKU files.
2023-06-02 15:48:11 -07:00
Marty Y. Lok
6335f610c8 [Nokia][device-data] Modify the Nokia-7250IXRE platform specific reboot script (#14568)
Why I did it

When reboot the chassis by issuing "sudo reboot" on Supervisor card. The internal midplane communication xe0 should be shutdown to avoid double reboot on the linecard.
Added a udev link rule to disable the autoneg on AMD xgbe port Xe0 and Xe1 and make the setting in sync with the peer Broadcom greyhound ports.

How I did it

Modify the Nokia-7250IXRE specific reboot script on the Supervisor card to shutdown the internal interface xe0. Also move reboot linecard code to the top of the script to make sure the notification has been send to Linecard before shutdown the xe0 interface.
Introduced a new rule 80-net-by-driver.link to disable the autoneg on the AMD size. This change requires the latest NDK which contains the change to set the autoneg on the xe0 and xe1 port on the Greyhound.

Signed-off-by: mlok <marty.lok@nokia.com>
2023-05-17 12:32:42 +08:00
Pavan-Nokia
f6f060f49d
[armhf][Nokia-7215]Add SFP refactor support for Nokia-7215 platform (#14551)
Why I did it
Add support for SFP refactor on Nokia-7215 Marvell armhf platform.

Platform: armhf-nokia_ixs7215_52x-r0
HwSKU: Nokia-7215
ASIC: marvell
Port Config: 48x1G + 4x10G (SFP+)
How I did it
Modify sfp.py to support SFP refactor optoe driver and platform.json to facilitate proper OC test completion.

How to verify it
Build armhf target for Nokia-7215 and verify proper Xcvrd and SFP refactor operation.
2023-04-17 17:26:15 -07:00
Pavan-Nokia
cb2e03da8e
[Nokia-7215]Update Marvell EZB XML files (#14261)
Update cnc-base counters to 4096 from 0 in the Marvell SAI
Easy bringup XML files
2023-03-17 10:58:55 -07:00
Marty Y. Lok
e6fde1d9e5
[Nokia][devicedata] Modified the port autoneg default setting for Nokia-7215 platform (#13459)
Why I did it
autoneg is not supported in the previous release 202012 on Nokia-7215 platform. To migrate to the 202205 image with autoneg support, we need to disable the autoneg to allow the link to be up when issue load minigraph. This requires to change the autoneg setting to be off in the port_config.ini file.

How I did it
Modify the port_config.ini to set the autoneg off.

How to verify it
Running the new image, with load mingraph.xml, execute "show int autonet status" should show autoneg disabled
2023-02-09 13:13:42 -08:00
Tejaswini Chadaga
3c485e02b2
[202205] Update BRCM SAI version to 7.1.31.4 (#13346)
Why I did it
To bring in the following fixes:

Revert temporary fix added to disable SA equal DA drops
CS00012273013 - [7.1][J2, J2c+] Disable SA Equals DA trap on DNX
CS00012274222 - How to block the voq for given destination port for a flow from a remote mod-id
CS00012275381 - SAI_INGRESS_PRIORITY_GROUP_STAT_PACKETS is incremented for port's PG's even if there are no traffic sent to that PG
CS00012274433 - Local Fault and Remote Fault are not polled by linkscan thread
How I did it
Merged above fixes to SAI code

How to verify it
Validated by running the basic sanity tests on XGS and DNX chassis platforms including

fib/test_fib.py
decap/test_decap.py
drop_counters/test_drop_counters.py
arp/test_arpall.py
2023-01-12 23:49:24 -08:00
Marty Y. Lok
44b661f63b
[Nokia-7215] Update Nokia-7215 device data which is required by the new version of Marvell SAI 1.10.2-2 (#13278)
Why I did it
Update the Nokia-7215 device data which is required by the new version of the Marvell SAI 1.10.2-2 to fix the syncd crash issue.

How I did it
Update the device data in folder device/nokia/armhf-nokia_ixs7215_52x-r0 /Nokia-7215.

How to verify it
With this PR, syncd should be running fine. Syncd should not crash.

Signed-off-by: mlok <marty.lok@nokia.com>
2023-01-06 14:47:03 -08:00
Marty Y. Lok
ad3beb6905 [Nokia][device-data] Rename the port name in the port_config.ini and also remove ECN setting in the BCM config file (#13053)
Signed-off-by: mlok <marty.lok@nokia.com>
2023-01-05 12:37:26 +08:00
mssonicbld
332480f4eb
DNX(J2/J2c/J2c+): Reserve Non-ECMP Fec Resource for Non-ECMP Route Nexthops/NBR Entries (#13076) (#13089) 2022-12-17 15:12:34 +08:00
judyjoseph
ab713dcfb6 Use the macsec_enabled flag in platform to enable macsec feature state (#11998)
* Use the macsec_enabled flag in platform to enable macesc feature state
* Add macsec supported metadata in DEVICE_RUNTIME_METADATA
2022-11-10 18:08:42 +00:00
vmittal-msft
89ac469d62 Updated config files to disable DLR_INIT capability (#12401) 2022-10-25 20:42:28 +00:00
henry huang
138c428dea fixed nokia platform m0 asic mismatch (#12148)
changed the platform device name under nokia directory; we now need to specify marvell armhf/arm64 to provide more accurate platform identity. otherwise onie discovery won't recognize the asic being installed.

Why I did it
when we load images using onie discovery, the process was failing because of marvell ASIC mismatch

How I did it
replace the platform asic with marvell-armhf under 7215

How to verify it
load a new image using http server and verify that the image can be loaded successfully
2022-10-25 20:38:45 +00:00
Marty Y. Lok
626d516c54 [Nokia] Update Nokia platform IXR7250E device data (#11611)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-10-11 21:47:53 +00:00
saksarav-nokia
5f385de2b7 [Nokia][Nokia-IXR7250E-36x100G & Nokia-IXR7250E-36x400G] Update BCM (#11577)
config to support ERSPAN egress mirror and also set flag to preserve ECN
2022-09-01 00:05:12 +00:00
saksarav-nokia
a5171349a7
[NOKIA][DEVICE]Updated BCM config file to disable the cmic dma abort during cold boot and recycle port setting (#11825)
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
2022-08-24 15:53:50 -07:00
Marty Y. Lok
948c932cee [Nokia][IXR7250E] Add Nokia platform Nokia-IXR7250E-36x100GE 100G line card device dat (#11382)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-07-28 20:34:05 +00:00
vmittal-msft
8035e3d9a7 Updated Chassis MMU settings for 40G/100G/400G line cards (#11108)
* Updated Chassis MMU settings for 40G/100G/400G line cards
2022-07-05 16:10:50 +00:00
saksarav-nokia
5a3c8d693f Updated Nokia device BCM and platform config (#11106) 2022-06-22 23:08:51 +00:00
Jon Goldberg
3f12919dee [Nokia ixs7215] change var/log size to 4GB (#11122)
This makes use of #11121 to add support for configuration of VAR_LOG_SIZE on Nokia IXS7215
2022-06-16 02:12:59 +00:00
abdosi
0285bfe42e
[chassis] Fix issues regarding database service failure handling and mid-plane connectivity for namespace. (#10500)
What/Why I did:

Issue1: By setting up of ipvlan interface in interface-config.sh we are not tolerant to failures. Reason being interface-config.service is one-shot and do not have restart capability. 

Scenario: For example if let's say database service goes in fail state  then interface-services also gets failed because of dependency check but later database service gets restart but interface service will remain in stuck state and the ipvlan interface nevers get created.

Solution: Moved all the logic in database service from interface-config service which looks more align logically also since the namespace is created here and all the network setting (sysctl) are happening here.With this if database starts we recreate the interface.

Issue 2: Use of IPVLAN vs MACVLAN

Currently we are using ipvlan mode.  However above failure scenario is not handle correctly by ipvlan mode. Once the ipvlan interface is created and ip address assign to it and if we restart interface-config or database (new PR) service Linux Kernel gives error "Error: Address already assigned to an ipvlan device."  based on this:https://github.com/torvalds/linux/blob/master/drivers/net/ipvlan/ipvlan_main.c#L978Reason being if we do not do cleanup of ip address assignment (need to be unique for IPVLAN)  it remains in Kernel Database and never goes to free pool even though namespace is deleted. 

Solution: Considering this hard dependency of unique ip macvlan mode is better for us and since everything is managed by Linux Kernel and no dependency for on user configured IP address.

Issue3: Namespace database Service do not check reachability to Supervisor Redis Chassis   Server.

Currently there is no explicit check as we never do Redis PING from namespace to Supervisor Redis Chassis  Server. With this check it's possible we will start database and all other docker even though there is no connectivity and will hit the error/failure late in cycle

Solution: Added explicit PING from namespace that will check this reachability.

Issue 4:flushdb give exception when trying to accces Chassis Server DB over Unix Sokcet.

Solution: Handle gracefully via try..except and log the message.
2022-05-24 16:54:12 -07:00
Marty Y. Lok
937bf09c92
{nokia] Update Nokia IXR7250e supervisor card device data (#10595)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-05-19 11:38:34 -07:00
saksarav-nokia
f311947cfa
[Nokia][device] Updated the BCM config file to reduce the CPU usage (#10485)
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
2022-04-07 14:34:32 -07:00
Marty Y. Lok
13353dffe8
[Nokia][device] Update the BCM config with Recycle ports info for Nokia IXR7250E platform (#10389)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-03-31 20:54:40 -07:00
dflynn-Nokia
99b7891e4d
[Nokia ixs7215] Fixes to support Debian bullseye (#10309)
The following changes are provided to support bullseye and the latest master
branch content.
    - Accommodate relocated fan and thermal sysfs entries in bullseye
    - Add support for chassis and PSU HW revision


Why I did it
Fix platform issues introduced by the bullseye kernel upgrade.

How I did it
Minor fixes to Nokia ixs7215 platform code

How to verify it
Execute the following CLI commands
show platform summary
show platform fan
show platform temperature
2022-03-22 17:58:46 -07:00
Marty Y. Lok
e919f4dafa
[Nokia][IXR7250E]Update Nokia IXR7250E platform device data file (#10091)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-03-21 17:58:03 +05:30
Marty Y. Lok
5a531f4eb2
[Nokia][VoQ] The role of the Inband port should be "Inb" and recycle port (#9950)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-03-15 09:21:50 -07:00
saksarav-nokia
5e1acf0225
[Nokia][platform]Modify BCM config & platform_reboot for Nokia-IXR7250E-36x400G (#9990)
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
2022-02-25 19:57:38 -08:00
saksarav-nokia
d136a39524
[Nokia][platform] Modified Nokia device data to support midplane (#9914)
Added midplane_subnet in chassisdb.conf for interfaces-config.sh to create midplane interface in multi-asic namespaces.

Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
2022-02-08 14:03:12 -08:00
saksarav-nokia
e7877bf9df
[Nokia][platform] Modified the bcm config file for Nokia-IXR7250E-36x400G (#9622)
Why I did it
Updated the BCM config recommended by Broadcom for Nokia-IXR7250E-36x400G

How I did it
Updated the BCM config file

How to verify it
Verified running the image with this BCM config in Nokia-IXR7250E-36x400G and ensured that the syncd container was stable, ports were up and passing the traffic.

Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
2022-01-31 09:53:07 -08:00
Marty Y. Lok
0fa687a458
Update Nokia platform IXR7250E device data (#9209)
Add BCM config files for linecard Nokia-IXR7250E-36x400G and Supervisor card Nokia-IXR7250E-SUP.
2021-11-16 17:11:49 -08:00
Marty Y. Lok
41756194c7
[Nokia][supervisor]Fixed the asic_type for Nokia IXR7250E supervisor card. (#9139)
The Nokia IXR7250E supervisor card asic_type should be broadcom-dnx instead of broadcom. Fixes #9140
2021-11-03 15:58:44 -07:00
dflynn-Nokia
1957558362
[Nokia ixs7215] Add new platform capabilities to platform.json (#9032)
This commit more fully declares the HW capabilities of the Nokia-7215
platform. For example, support for the threshold values associated with each
thermal sensor is described. The intent here is to inform the sonic-mgmt
platform test cases of which HW features are supported.

This commit must align with PR# 4521 within the sonic-mgmt git repo which is
currently under review. Any changes to that PR will need to be reflected in
this commit.
2021-10-27 09:56:46 +08:00
Marty Y. Lok
c37470544a
[Nokia][port]Modify the Nokia-IXR7250E-36x400G device data (#8875)
-- Based on the new BCM configuration, Modify the portcoreid for the front panel port in the port_config.ini for line card Nokia-IXR7250e-36x400G
 -- Correct the pcie.pmal file
 -- Update the platform_ndk.json with new field "update-asic-pvt"
 -- Add chassis-internal-intf to chassisdb.conf
 -- update platform_reboot

Signed-off-by: mlok <marty.lok@nokia.com>
2021-10-14 13:47:12 -07:00
Qi Luo
add9b651b6
Add platform_asic file to each platform folder in sonic-device-data based package (#8542)
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.

One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.

After this PR merged, each platform vendor has to add one mandatory text file  `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.

I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.

You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```

Also support
```
broadcom-dnx
```

#### How I did it

#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
2021-10-08 19:27:48 -07:00
Ying Xie
3e397ce8b2
[Nokia 7215] Rename alias column with etpN normination (#8879)
also add hwsku alias Nokia-M0-7215

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2021-09-30 15:27:54 -07:00
Ashok Daparthi-Dell
6cbdf11e53
SONIC QOS YANG - Remove qos tables field value refernce format (#7752)
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754

QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.

Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},

This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".

Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},

Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
2021-09-28 09:21:24 -07:00
dflynn-Nokia
1a2e852483
[Nokia ixs7215] Support show system-health (#8771)
* [Nokia ixs7215] Support show system-health
* [Nokia ixs7215] Fix LGTM alert
2021-09-17 12:01:12 +08:00
Marty Y. Lok
a675493a5a
Added Nokia IXR7250E support (#7809)
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards

How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
2021-08-17 12:26:04 -07:00
carl-nokia
88cbcb4045
[Nokia ixs7215] sfputil support + component tests (#8445)
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes

Co-authored-by: Carl Keene <keene@nokia.com>
2021-08-13 03:27:06 -07:00
carl-nokia
28dca68925
[Nokia] Add hwsku.json for the Nokia-7215 (#8372)
* add hwsku.json for the Nokia-7215
* added required default_brkout_mode to hwsku as its not optional
* remove tabs from the file so spacing consistent

Co-authored-by: Carl Keene <keene@nokia.com>
2021-08-12 15:41:41 +08:00