Commit e484ae9dd introduced systemd .timer unit to hostcfgd.
However, when stopping service that has timer, there is possibility that
timer is not running and the service would not be stopped. This PR
address this situation by handling both .timer and .service units.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
startup when doing redis PING since database_config.json getting
generated from jinja2 template is still not ready.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* [201911] skip_thermalctld for VS platform as it is
not supported
root@vlab-01:/# supervisorctl status
dependent-startup EXITED Aug 18 06:22 AM
rsyslogd RUNNING pid 18, uptime 0:12:26
start EXITED Aug 18 06:22 AM
supervisor-proc-exit-listener RUNNING pid 13, uptime 0:12:27
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* [201911] after PR #https://github.com/Azure/sonic-buildimage/pull/5204
this function is no more needed so cleaning up.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
SNMP and Telemetry services are not critical to switch startup.
They also cause fast-reboot not to meet timing requirements.
In order to delay start those service are associated with systemd
timer units, however when hostcfgd initiate service start, it start
the service and not the timer. This PR fixes this issue by
starting the timer associated with systemd unit.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
* Support for Control Plane ACL's for Multi-asic Platforms.
Following changes were done:
1) Moved from using blocking listen() on Config DB to the select() model
via python-swsscommon since we have to wait on event from multiple
config db's
2) Since python-swsscommon is not available on host added libswsscommon and python-swsscommon
and dependent packages in the base image (host enviroment)
3) Made iptables programmed in all namespace using ip netns exec
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Address Review Comments
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Fix Review Comments
* Fix Comments
* Added Change for Multi-asic to have iptables
rules to accept internal docker tcp/udp traffic
needed for syslog and redis-tcp connection.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Fix Review Comments
* Added more comments on logic.
* Fixed all warning/errors reported by http://pep8online.com/
other than line > 80 characters.
* Fix Comment
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Verified with swsscommon package. Fix issue for single asic platforms.
* Moved to new python package
* Address Review Comments.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Address Review Comments.
The template is referenced relative to the script path and this could
results in errors in case script is run from root. Add explicit
path to the template file name.
Also, moving telemetry_var template to template dir.
And remove double quotes from around json dict.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Modify port_config.ini files multi-asic vs platform. Changes done:
- Add new columns: index, asic_port_name, role(Int/Ext)
- Modify alias of interface names. Alias should match the interface names present in minigraph file.
Signed-off-by: SuvarnaMeenakshi <sumeenak@microsoft.com>
NUM_ASIC environment variable was added so that it could be used by other utilities.
This is not being used by any other utility or docker, hence removing the addition of NUM_ASIC environment variable.
Also, the environment variable was added by adding the variable value to /etc/environ file.
Upon each reboot, this file gets updated with the NUM_ASIC value but the existing value was not removed.
This causes multiple lines getting appended in /etc/environ file upon each reboot.
Signed-off-by: SuvarnaMeenakshi <sumeenak@microsoft.com>
[sonic-swsss] Fix the issue of field "next_hop_ip" not getting updated
in state DB in ERSPAN Mirror (#1375)
[vlanmgr] Support Jumbo Frame By Default (#1393)
[fec] added logic that put port down before applying fec
onfiguration (#1399)
[fec] Get FEC mode when port is already admin down (#1403)
Refine getDbId() calling to fix build after swss-common change
(#1245)
Update the name from get_npu_device_id() -to get_asic_device_id() and move from device_info.py, to the new file multi_asic.py in sonic-py-common so that it references to the correct valid constants.
when portsyncd starts, it first enumerates all front panel ports
and marks them as old interfaces. Then, for new front panel ports
it checks if their indexes exist in previous sets. If yes, it will
treats them as old interfaces and ignore them.
The reason we have this check is because broadcom SAI only removes
front panel ports after sai switch init.
So, if portsyncd starts after orchagent, new interfaces could be
created before portsyncd and treated as old interface.
Signed-off-by: Guohan Lu <lguohan@gmail.com>
Copy proper fancontrol config file to the proper destination. Also some minor refactoring for code reuse to help prevent issues like this in the future.
Fixes a bug introduced by #4599
This is to backport the #4886 to 201911
Calculate pool size in t1 as 24 * downlink port + 8 * uplink port
- Take both port and peer MTU into account when calculating headroom
- Worst case factor is decreased to 50%
- Mellanox-SN2700-C28D8 t0, assume 48 * 50G/5m + 8 * 100G/40m ports
- Mellanox-SN2700 (C32)
- t0: 16 * 100G/5m + 16 * 100G/40m
- t1: 16 * 100G/40m + 16 * 100G/300m
Signed-off-by: Stephen Sun <stephens@nvidia.com>
a) we should use get_platform() with new sonic_py-common package
b) In 201911 DB Connector is still using db id based constructor
as following PR https://github.com/Azure/sonic-buildimage/pull/4549
is not cherry-picked yet. So revert the change to use db is insatead of
db_name for now.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>