- Why I did it
platform.json of 4600C only has 2 CPU core thermal sensors, but there are 4 actually
- How I did it
Added thermal sensors for CPU core 2 and core 3.
- How to verify it
Build.
- Why I did it
The chassis name in MSN4410 platform_components.json is not correct
- How I did it
Fix the chassis name
- How to verify it
Run relevant platform API test
Signed-off-by: Kebo Liu <kebol@nvidia.com>
ded0344 Return both 'vendor_rev' and 'hardware_rev' keys from get_transceiver_info to support both earlier and later versions of xcvrd
b3442cc Change log_error to log_info when transceiver module is transitioned
3d3a73c Fix problem introduced with new SFP caching paradigm
2915746 Add script to reboot all IMMs
17ad221 Fix the position_in_parent for the psu entity
207e731 No longer force read pages at SFP init time
b387921 Fixed the voltage and power with rounding to 2 digit decimals
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
Updated the BCM config recommended by Broadcom for Nokia-IXR7250E-36x400G
How I did it
Updated the BCM config file
How to verify it
Verified running the image with this BCM config in Nokia-IXR7250E-36x400G and ensured that the syncd container was stable, ports were up and passing the traffic.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
[Build]: Fix hundreds of thousands lines of logs printed in marvell-armhf
It is caused by the bad format of the marvell sai package mrvllibsai_armhf_1.7.1-6.deb, increasing the waiting time to reduce the logs, and reduce the waste of the CPU.
- Why I did it
Need to remove old static configs from sai.profile files.
New implementation: Azure/sonic-swss#1959
New configuration: #9658
- How I did it
Remove SAI_VXLAN_SRCPORT_RANGE_ENABLE=1 lines from files per HWSKU
- How to verify it
When static config is removed following test will fail (src port will be in range 0-255)
py.test vxlan/test_vnet_vxlan.py --inventory "../ansible/inventory, ../ansible/veos" --host-pattern (testbed)-t0 --module-path ../ansible/library/ --testbed (testbed)-t0 --testbed_file ../ansible/testbed.csv --allow_recover --assert plain --log-cli-level info --show-capture=no -ra --showlocals --disable_loganalyzer --skip_sanity --upper_bound_udp_port 65535 --lower_bound_udp_port 64128
- Why I did it
Remove obsolete parameter that enables static VXLAN src port range
provide functionality no generate json config file according to appropriate parameter in config_db
Done for
SN3800:
• Mellanox-SN3800-D28C50
• Mellanox-SN3800-C64
• Mellanox-SN3800-D28C49S1 (New 10G SKU)
SN2700:
• Mellanox-SN2700-D48C8
- How I did it
Remove SAI_VXLAN_SRCPORT_RANGE_ENABLE=1 from appropriate sai.profile files
Created vxlan.json file and added few params that depends on DEVICE_METADATA.localhost.vxlan_port_range
- How to verify it
File /etc/swss/config.d/vxlan.json should be generated inside swss docker when it restart
[
{
"SWITCH_TABLE:switch": {
"vxlan_src": "0xFF00",
"vxlan_mask": "8"
},
"OP": "SET"
}
]
Signed-off-by: Andriy Yurkiv <ayurkiv@nvidia.com>
- Why I did it
New version of mellanox platform management code available adding support for new platforms and fixing bugs.
- How I did it
1. Updated the submodule
2. Updated makefile version references
3. Regenerated SONiC patches
Added midplane_subnet in chassisdb.conf for interfaces-config.sh to create midplane interface in multi-asic namespaces.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
#### Why I did it
PR9611 - sonic-scheduler.yang pattern issue
#### How I did it
Modified the scheduler name pattern string to accept any string
#### How to verify it
Sonic yang tests
Why I did it
Need to be able to run smartctl when pmon docker is not running.
How I did it
Removed the pmon dependency for pmon as well as the command wrapper and added it to the debian-extension.
How to verify it
Stop pmon
Run smartctl from the host and verify it runs without error
Updates include the following changes in order to support new Mellanox platforms and drivers (Azure/sonic-linux-kernel#259)
10ef390 Update kconfig to support / enable newly backported mellanox patches.
6a949e1 Add backported patches for Mellanox hw-mgmt V.7.0020.1300
e1913f7 Rename and reformat patch headers
#### Why I did it
Include sonic-bgp-monitor to setup.py so it gets included in /usr/local/yang-models when installing the package
#### How I did it
#### How to verify it
install the package
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
#### Description for the changelog
<!--
Write a short (one line) summary that describes the changes in this
pull request for inclusion in the changelog:
-->
#### A picture of a cute animal (not mandatory but encouraged)
- Why I did it
Fix issue: 'sx_port_mapping_t' object has no attribute 'slot_id'. sx_port_mapping_t only has attribute slot.
- How I did it
Change slot_id to slot.
- How to verify it
Manual test
- Why I did it
Python select.select accept a optional timeout value in seconds, however, the value passes to it is a value in millisecond.
- How I did it
Transfer the value to millisecond.
- How to verify it
Manual test
Why I did it
To enable test support for BFD-related features, the PTF docker needs to have the proper support for BFD. This PR aims to add BFD support in ptf docker.
How I did it
Clone and build OpenBFDD for PTF docker.
How to verify it
Build locally and verify BFD is supported.
- Why I did it
To include latest SDK fixes:
1. On CMIS modules, after low power configuration, the firmware waited for the module state to be ModuleReady instead of ModuleLowPower causing delays.
2. When connecting SN4600C, 100GbE port with CWDM4 module (Gen 3.0), link up time is 30 seconds.
and to include SAI fixes \ changes:
1. Reduce verbosity for resource check vendor data not found
2. Fix metadata validation, check default value on conditions check
3. Add 100MB, 10MB to 2201 system
4. L3 VXLAN overlay ECMP
5. VXLAN srcport API implementation
6. Fix scheduler profile null (default values) when set on sub group scheduler group
7. Fix ACL binding restoration when port leaves a LAG
8. Fix route logic for set next hop/action and reference counter for ECMP overlay
- How I did it
1. Updated SDK/FW submodule and relevant makefiles with the required versions.
2. Update SAI submodule and relevant makefile with the required version.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Why I did it
Requirements from Microsoft for fwutil update all state that all firmwares which support this upgrade flow must support upgrade within a single boot cycle. This conflicted with a number of Mellanox upgrade flows which have been revised to safely meet this requirement.
How I did it
Added --no-power-cycle flags to SSD and ONIE firmware scripts
Modified Platform API to call firmware upgrade flows with this new flag during fwutil update all
Added a script to our reboot plugin to handle installing firmwares in the correct order with prior to reboot
How to verify it
Populate platform_components.json with firmware for CPLD / BIOS / ONIE / SSD
Execute fwutil update all fw --boot cold
CPLD will burn / ONIE and BIOS images will stage / SSD will schedule for reboot
Reboot the switch
SSD will install / CPLD will refresh / switch will power cycle into ONIE
ONIE installer will upgrade ONIE and BIOS / switch will reboot back into SONiC
In SONiC run fwutil show status to check that all firmware upgrades were successful
- Why I did it
The feature state can be a jinja template, like in this file - https://github.com/Azure/sonic-buildimage/blob/master/files/build_templates/init_cfg.json.j2#L39.
Without this change it is not possible to validate a configuration file.
- How I did it
Relaxes the constraint on feature state. Feature state leaf can be any string.
- How to verify it
Run UT.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Why I did it
Update Broadcom SAI to version 6.0.0.13, SDK 6.5.24, saibcm-modules to 6.5.24.gpl
How I did it
Brcm SAI 6.0 EA with fixes for CS00012203367, CS00012219613, CS00012213974, CS00012218290, CS00012217169, CS00012211718, CS00012213944, CS00012215529, CS00012218100, CS00012214196, CS00012212681, CS00012205138, CS00012208537, CS00012185316, CS00012208524, CS00012203367, CS00012197364.
51a9fbf [debug dump] Missing Dict Key handled in the MatchOptimizer (#2014)
ac8fdd3 [Auto Techsupport] Added Event Driven TS to Command Reference (#1985)
458a0c2 [fdbshow] Adding more options for fdbshow and show mac (#1982)
#### Why I did it
src\tacacs\bash_tacplus\debian\rules file mode is 644, and debian build will change it to 755, which will cause image version contains 'dirty'
#### How I did it
Change src\tacacs\bash_tacplus\debian\rules file mode to 755
#### How to verify it
Check the image version not contains dirty
#### Which release branch to backport (provide reason below if selected)
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [*] 202111
#### Description for the changelog
Change src\tacacs\bash_tacplus\debian\rules file mode to 755
#### A picture of a cute animal (not mandatory but encouraged)
Why I did it
sonic-broadcom-dnx.bin should be able to installed on DNX supported platform, whereas it doesn't.
How I did it
Changed CONFIGUTED_PLATFORM to TARGET_MACHINE to distinguish broadcom and broadcom-dnx
How to verify it
tar sonic-broadcom-dnx.bin and verify its platforms_asic contians dnx platforms
Also verify on image with other asic, no regression.
Why I did it
Eliminate benign firsttime boot error reported when running on platforms that do not support kdump.
How I did it
Change rc.local to check for presence of the file /etc/default/kdump-tools before referencing it.
How to verify it
Install a new image on an armhf or arm64 platform and check for a failed reference to /etc/default/kdump-tools on firsttime boot.
- External PHY is managed via gearbox (gbsybcd docker container) in SONiC
- Enhanced 'External PHY management' from SONiC's single-ASIC environment to multi-ASIC
- Enhanced gbsyncd docker container from single Namespace to multi-Namspace mode
- Added gbsyncd.service.j2 on per_namespace basis.
- Each namepace/ASIC now to have its unique gbsyncd<ASIC#> docker container with its
own Gearbox table, redis-DB
Signed-off-by: Shyam Kumar <shyakuma@cisco.com>
Why I did it
ConfigDB schema generated by minigraph parser can't pass yang validation.
How I did it
Modify minigraph.py, and use 'state' to replace 'status'.
How to verify it
Run UT for sonic-config-engine.
Use minigraph parser to generate ConfigDB schema, and run yang validation.
Signed-off-by: Gang Lv ganglv@microsoft.com
Why I did it
end2end test is blocked by Yang model for BGP monitor.
How I did it
Create new yang files for BGP monitor, and add UT.
How to verify it
Follow the steps in #9711.
Run UT for sonic-yang-models.
Signed-off-by: Gang Lv ganglv@microsoft.com
#### Why I did it
AAA yang model is not up to date.
#### How I did it
Add fallback and trace field, and replace boolean_type
#### How to verify it
Run UT for sonic_yang_models.
Follow the steps from #9710
Why I did it
Config db schema generated by minigraph can’t pass yang validation, bgp_asn must not be None.
How I did it
Update sampe-voq-graph.xml to add bgp_asn.
How to verify it
Build sonic-config-engine.
Run command 'sonic-cfggen -m tests/sample-voq-graph.xml -p tests/voq-sample-port-config.ini --print-data', and check bgp_asn.
Signed-off-by: Gang Lv ganglv@microsoft.com
Tested on a Celestica Seastone2 DX030 switch
Testing scenarios:
- Various QSFP ports in both normal and breakout config.
- 100G and 40G link speed show different colors.
- SFP1 port works.
Signed-off-by: Christian Svensson <blue@cmd.nu>
- Why I did it
For MSN4410/MSN4600/MSN4700 now they can support fetching PSU voltage threshold, no need to skip the psu voltage check in system health monitoring, so update the system health monitoring configuration file for these platforms.
- How I did it
remove skip PSU change config from the system_health_monitoring_config.json file
- How to verify it
Build image run on these platforms, system health monitoring will not report error against PSU voltage
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Optimize thermal control policies to simplify the logic and add more protection code in policies to make sure it works even if kernel algorithm does not work.
- How I did it
Reduce unused thermal policies
Add timely ASIC temperature check in thermal policy to make sure ASIC temperature and fan speed is coordinated
Minimum allowed fan speed now is calculated by max of the expected fan speed among all policies
Move some logic from fan.py to thermal.py to make it more readable
- How to verify it
1. Manual test
2. Regression
- Why I did it
MSN4700 platform has 8 lanes per port and thus can support 2x40G with each lane running at 10G
- How I did it
Added 40G to 2x200G breakout mode in platform.json
- How to verify it
Run config int break Ethernet0 2x40G[200G,100G,50G,25G,10G,1G]
And verify the command runs successfully and the port speed was set to 40G with a 2x breakout.
* Description: Currently IPv4 routes with IPv6 link local next hops are
not properly installed in FPM.
Reason is the netlink decoding truncates the ipv6 LL address to 4 byte
ipv4 address.
Ex : fe80:: is directly converted to ipv4 and it results in 254.128.0.0
as next hop for below routes
show ip route
Codes: K - kernel route, C - connected, S - static, R - RIP,
O - OSPF, I - IS-IS, B - BGP, E - EIGRP, N - NHRP,
T - Table, v - VNC, V - VNC-Direct, A - Babel, D - SHARP,
F - PBR, f - OpenFabric,
> - selected route, * - FIB route, q - queued, r - rejected, b - backup
B>* 2.1.0.0/16 [200/0] via fe80::268a:7ff:fed0:d40, Ethernet0, weight 1,
02:22:26
B>* 5.1.0.0/16 [200/0] via fe80::268a:7ff:fed0:d40, Ethernet0, weight 1,
02:22:26
B>* 10.1.0.2/32 [200/0] via fe80::268a:7ff:fed0:d40, Ethernet0, weight
1, 02:22:26
Hence this fix converts the ipv6-LL address to ipv4-LL (169.254.0.1)
address before sending it to FPM. This is inline with how these types of
routes are currently programmed into kernel.
Signed-off-by: Nikhil Kelapure <nikhil.kelapure@broadcom.com>
- Why I did it
The feature state can be a jinja template, like in this file - https://github.com/Azure/sonic-buildimage/blob/master/files/build_templates/init_cfg.json.j2#L39.
Without this change it is not possible to validate a configuration file.
- How I did it
Relaxes the constraint on feature state. Feature state leaf can be any string.
- How to verify it
Run UT.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>