FPGA driver crash fix for stale buffer in i2c transfer
LED firmware load issue fix.
10G port swapfix
psu/sfp bug fixes to report correct states/status of hw
- Sfp,Eeprom,Chassis(transceiver change event) support added for z9264f Platform 2.0 API
- Added Interrupt handler to SFP change event in dell_z9264f_fpga_ocores.c
- Fixed few indentation and offset issues in sfputil.py for z9264f
- optoe driver truncates invalid pages(ff) but sff driver doesn't truncate.so,the DOM related calculation made by sff8436 driver will show incorrect data.
- Few optics doesn't support DOM.
- SFP plugins currently returns None for unreadable pages and this'd throw the below mentioned error in sfpshow eeprom --dom.
* Remove the divide by 4 operation to the under the hood SAI
This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture
This change must have support from SAI change to reach the correct
config
Signed-off-by: Wenda <wenni@microsoft.com>
* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool
Extend to 7060 and 6100
Signed-off-by: Wenda <wenni@microsoft.com>
* Add more TH/TH2 hwskus
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update config test
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Add TH2 ingress lossy profile
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Move the divide by 4 operation to SAI internal
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15
- Broadcom SAI 3.5 GA release 20190924.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Corrected the ingress and egress lossy and lossless buffer pool and profile values.
Single pool for lossy and lossless traffic for PFC priority 3 and 4.
In HWSKU DellEMC-S5232f-P-100GG/25G/10G. Defaults to lossy profile. No Lossless support.
2 default mmu_init.data files (TD3-DEFAULT-LOSSLESS-P3P4 and "TD3-DEFAULT" created in SAI code. This will have cpu pool configuration and MMU init related configurations.
TD3-DEFAULT.data file is only supports lossy.
TD3-DEFAULT-LOSSLESS-P3P4.data file is supports lossless on P3 and P4.
* [devices]: Add a new supported device DellEMC s5232f
* Switch Vendor: DellEMC
* Switch SKU: s5232F
* ASIC Vendor: Broadcom
* Swich ASIC: Trident3
* Port Configuration: 32x100G
* SONiC Image: sonic-broadcom.bin
* LED support for s5232f
* Changes Include ipmitool implementation for platform_sensors script is inclued in pmon startup
* Added 100G,25G,10G configruation ( 100G is default).
* s5232[device] PSU detecttion and default led state support
* Switch Vendor: DellEMC
* Switch SKU: s5232F
* ASIC Vendor: Broadcom
* Swich ASIC: Trident3
* Port Configuration: 32x100G
* SONiC Image: sonic-broadcom.bin
* LED support for s5232f
* Changes Include ipmitool implementation for platform_sensors script is inclued in pmon startup
* Added 100G,25G,10G configruation ( 100G is default).
This commit adds new code and JAON file to support PFC
and MMU setting for PFC feature on z9264f-Q64 (40G) T0
and T1 support. The buffers_defaults_t0.json and
buffers_defaults_t1.json file has the recommended values
for T0 and T1 configuration.
Unit tested and verified by running JSON file and checking
the hardware registers and table in broadcom. THe settings
in hardware are reflecting the JSON values.
Signed-off-by: Harish Venkatraman <harish_venkatraman@dell.com>
This commit adds new code and JSON file to support PFC and
broadcom recommended MMU setting for PFC feaure on z9264f
(100G) T1 support. The buffers_defaults_t1.json file has
the broadcom recommended values for T1 configuration.
Unit tested and verified by running the JSON file and checking
the hardware registers and table in broadcom. The settings in
the hardware is reflecting the broadcom recommended values.
Signed-off-by: Harish Venkatraman <harish_venkatraman@dell.com>
* DellEMC S6000, xcvrd support
* sleep 1 second to avoid busy looping
* removal of dead code
* Correct typo error to 1 second
* Introduced 1 second sleep
* Revamped script with blocking call support
* get_transceiver_change_event api definition update
* adding timeout support for get_transceiver_change_event
* [dell/Z9100] Fix for optics not detected in fanout mode
This commit fixes the issue of optics not detected
error while running sfputil show eeprom command. The root
casuse was the value of port index from port_config.ini for
fan out scenario. The port index should be starting from 0
and not 1. Platform cpld registers are assuming the port
numbers to start from 0 (lowermost bit), sfputils.py uses this
port number in get_presence function. Since the indexing passed
is wrong the optics was not detected and gave SFP EEPROM not
detected message.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* [dell/z9100] Fix for optics not detected in fanout mode
This commit fixes the issue of optics not detected error
while running sfputil show eeprom command. The root cause
was wrong port_index in fan out scenarios. Earlier fix of
changing the port_config.ini is reverted and changes made
in z9100 platform specific sfputil.py file. The port number
is decrement and tested for both 100G and 50G fanout cases.
Tested for the following show commands and test was succesful
show interfaces status, show interfaces transceiver eeprom,
show interfaces transceiver lpmode, show interface tranceiver
presence.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* QoS config change: 1) DSCP mapping; 2) link pg/queue 6 to lossy buffer;
3) redistribute scheduler
Signed-off-by: Wenda <wenni@microsoft.com>
* Add scheduling weight to queue 2
Signed-off-by: Wenda <wenni@microsoft.com>
* Link pg/queue 2 to lossy buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the pg headroom for a7060-D48C8 50G
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for qos
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom size, and update egress lossy pool size accordingly
Signed-off-by: Wenda <wenni@microsoft.com>
* Update headroom pool size; Update ingress service pool and egress lossy
pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* a7260: update headroom pool size; Update ingress service pool and egress lossy pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for buffer
Signed-off-by: Wenda <wenni@microsoft.com>
dell_ich module fails to load sometimes due to the failure of pci_get_drvdata().
This function is responsible for fetching INTEL PCI related memory handle in kernel. This is implemented in lpc_ich kernel module.
Due to race in addition/deletion of kernel modules, sometimes lpc_ich loads after dell_ich.
Because of this behaviour dell_ich module fails to load.
Fixed by addding dependency between modules.
Removed i2c_mux_gpio module from blacklist entry as it is not the original root case of this issue.
This commit has the forward porting of changes from 20180330
to master. Unit tested by checking the broadcom registers
for the values. The values in hardware reflect the correct values
except for TC to PFC priority group map values. Master branch values
for TC to PFC priority group map for both z9100 and s6100 in incorrect,
I have a build of Oct 12 master and the values are correct in
that build.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>