- Why I did it
When PSU is powered off, the PSU is still on the switch and the air flow is still the same. In this case, it is not necessary to set FAN speed to 100%.
- How I did it
When PSU is powered of, don't treat it as absent.
- How to verify it
Adjust existing unit test case
Add new case in sonic-mgmt
- Why I did it
This is to update the common sonic-buildimage infra for reclaiming buffer.
- How I did it
Render zero_profiles.j2 to zero_profiles.json for vendors that support reclaiming buffer
The zero profiles will be referenced in PR [Reclaim buffer] Reclaim unused buffers by applying zero buffer profiles #8768 on Mellanox platforms and there will be test cases to verify the behavior there.
Rendering is done here for passing azure pipeline.
Load zero_profiles.json when the dynamic buffer manager starts
Generate inactive port list to reclaim buffer
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* [Nokia ixs7215] Platform API fixes
This commit delivers the following fixes
- Fix bug preventing access to second PSU eeprom
- Fix bug preventing updates to front panel PSU status led
- Fix SFP reset test case failure
* Fix LGTM alert
* Changed Debian package dependency in order to support both python or python3 packages
* Fix Python scripts to be compatible with python2.7/python3 versions
* hw-mgmt: attributes: Fix PSU power sensor attributes capability
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
In case an app.ext requires a dependency syncd^1.0.0, the RPC version of syncd will not satisfy this constraint, since 1.0.0-rpc < 1.0.0. This is not correct to put 'rpc' as a prerelease identifier. Instead put 'rpc' as build metadata in the version: 1.0.0+rpc which satisfies the constraint ^1.0.0.
- How I did it
Changed the way how to version in RPC and DBG images are constructed.
- How to verify it
Install app.ext with syncd^1.0.0 dependency on a switch with RPC syncd docker.
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
Depends on Mellanox hw-mgmt 7.0010.3300
Why I did it
Adjust LED logical according to hw-mgmt change.
How I did it
Add a trigger to set LED to blink.
How to verify it
Manual test
- Why I did it
Bug fix:
bad_param request due to missing parser rest command while running mlxlink
- How I did it
Advance to MFT tool version to 4.17.2-12.
- How to verify it
Manually tested on all mellanox platforms.
- Why I did it
Upgrade to the latest version of hardware management in order to incorporate the latest bugfixes and drivers in the kernel.
- How I did it
Updated the version number and submodule for hw-mgmt.
- How to verify it
This has been verified on all Mellanox platforms through a combination of sonic-mgmt tests and other internal verification.
Why I did it
Currently the mellanox platform API is validating the file extensions of firmware packages to be installed for basic sanity checking. However, ONIE packages do not have an extension and as such if there is a "." in the name it is taken to be an extension and then fails the sanity check.
How I did it
I removed the check which ensures that ONIE images don't have a file extension.
How to verify it
Name the ONIE updater file 2021.onie and attempt to install it via fwutil install fw 2021.onie --yes
Why I did it
The fwutil update all utility expects the auto_update_firmware method in the Platform API to execute the update_firmware() call and not the install_firmware() call.
How I did it
Changed the method in the mellanox platform API component implementation.
How to verify it
Run fwutil update all with a CPLD update on a Mellanox platform and verify that it properly updates the firmware using the MPFA file.
the branch refers the branch name that the commit is in,
for example master, 202012, 201911, ...
In case there is no branch, the name will be HEAD.
release is encoded in /etc/sonic/sonic_release file.
the file is only available for a release branch.
It is not available in master branch.
example for master branch
```
build_version: 'master.602-6efc0a88'
debian_version: '10.7'
kernel_version: '4.19.0-9-2-amd64'
asic_type: vs
commit_id: '6efc0a88'
branch: 'master'
release: 'none'
build_date: Tue Dec 29 06:54:02 UTC 2020
build_number: 602
built_by: johnar@jenkins-worker-23
```
example for 202012 release branch
```
build_version: '202012.602-6efc0a88'
debian_version: '10.7'
kernel_version: '4.19.0-9-2-amd64'
asic_type: vs
commit_id: '6efc0a88'
branch: '202012'
release: '202012'
build_date: Tue Dec 29 06:54:02 UTC 2020
build_number: 602
built_by: johnar@jenkins-worker-23
```
Signed-off-by: Guohan Lu <lguohan@gmail.com>
- Why I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high, so that thermal algorithm would set fan speed to minimum allowed earlier and save power.
- How I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high
- How to verify it
Manual test
To Fix#8697 . The config load_minigraph initializes 'admin_status' to up when platform.json has DPB configs. This doesn't happen when using port_config.ini
The update minigraph has logic to initialize only the ports whose neighbors are defined or those belonging to portchannel
However, a change was introduced to have default admin status to be 'up' in portconfig.py when the minigraph was using platform.json
This will lead to sanity check failure in sonic-mgmt and thus no test cases could be run
* [Nokia ixs7215] Miscellaneous platform API fixes
This commit delivers the following fixes for the Nokia ixs7215 platform
- Fix bug in a fan API error path
- Add support for setting the fan drawer led
- Add support for getting/setting the front panel PSU status led
- Add support for getting the min/max observed temperature value
* [Nokia ixs7215] code review changes: temperature min/max values
To enable saiserver docker on different platforms, it needs different configuration files. make the saiserver docker mount them in hwsku folder.
Co-authored-by: Ubuntu <richardyu@richardyu-ubuntu-vm0.trsxrdzozv2e1czsze2t05vqzh.ix.internal.cloudapp.net>
#### Why I did it
New PSU could install different type of fan, so fan max/min speed should be read per PSU
#### How I did it
The existing implementation read PSU max/min fan speed from a common file, change it to read from per PSU file
#### How to verify it
Manual test
This commit adds support for changing the default console baud rate configured
within the U-Boot bootloader. That default baud rate is exposed via the value
of the U-Boot 'baudrate' environment variable. This commit removes logic that
hardcoded the console baud rate to 115200 and instead ensures that the U-Boot
'baudrate' variable is always used when constructing the Linux kernel boot
arguments used when booting Sonic.
A change is also made to rc.local to ensure that the specified baud rate is set
correctly in the serial getty service.
Update 202106 release with the Arista drivers from master.
This update is mostly targeted at chassis and is deemed stable.
Most notable chassis improvements:
- fix psu reporting in platform api
- powercycle fabrics on supervisor reboot
- improve card powercycle reliability
- fix led plugin when dealing with `Ethernet-Rec` and `Ethernet-IB`
- fix system-health cli reporting
- unset provisioning mode once the linecard has started
- fix `show version` when running as `admin`
- fix race between loading the eeprom module and sysfs file availablity
- implement `get_all_asics` platform API
- Why I did it
New release of MFT has the following changelog / RN
Fixed an issue that resulted in getting MVPD read errors from the mlxfwmanager during fast reboot.
Fixed mlxuptime sometimes generating a time less than previous due the wrong frequency calculation
- How I did it
Update makefile pointer to new version.
- How to verify it
Manually tested on all Mellanox platforms.
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
Why I did it
fix the dx010 system eeprom unavailable issue
How I did it
enable the i2c slave 30ms timeout mechanism
How to verify it
i2cstress test in DX010 iSMT controller bus
Co-authored-by: nicwu-cel <nicwu@celestica.com>
Why I did it
Update Makefile, so it does the following:
For a given platform, verify if platform/checkout/.ini exists and hence run the platform/checkout/template.j2. This allows platform code to be checked out during the 'make configure' stage.
How I did it
git clone git@github.com:Azure/sonic-buildimage.git
mkdir platform/cisco-8000
make init
make configure PLATFORM=cisco-8000
make all
Why I did it
serial-getty service exited in Dell S6100 device randomly.
How I did it
Added serial-getty to monit services.
How to verify it
Stop serial-getty in ssh session and check whether the service restarts or not.
Why I did it
platform test suite failed for few API's in DellEMC Z9332f platform.
How I did it
Modified the API's to return the expected values in the script.
How to verify it
Run platform test suite after making the changes.
- Why I did it
To fix failed test cases of Haliburton platform APIs that found on platform_tests script
- How I did it
Add device/celestica/x86_64-cel_e1031-r0/platform.json
Update functions to support python3.7
Add more functions follow latest sonic_platform_base
Fix the bug
- How to verify it
Run platform_tests script
Signed-off-by: Wirut Getbamrung [wgetbumr@celestica.com]
Move SAI libraries for Broadcom for XGS and DNX families to 5.0.0.6
Included fixes
```
CS00012195263 | [4.3][5.0][TD3] Packets with broken IP headers received on VLAN interface are not dropped
CS00012192505 | [4.3] Re-encap IPinIP decap packets
CS00012192502 | [3.7.5.2] Start LED shell script execution on all DELL based platforms causing all ports flapping on SAI 3.7.5.2
CS00012191363 | [4.3] Support of memscan thread to detect TCAM parity error
CS00012190932 | [4.3] SAI_PORT_PFC_X_RX_PKTS incremented incorrectly even when no PFC frames are received on that priority
CS00012183901 | [4.3][WARMBOOT] WARMReboot with active traffic causes port flap reported during warm reboot
CS00011382163 | [4.4] Support warm-boot from 3.5 to 4.3
CS00011318937 | [4.3] MACSec SAI Support for Jericho2c+
CS00011318926 | [4.3] Provide SAI support for Jericho2c+
CS00012195263 | [4.3][5.0][TD3] Packets with broken IP headers received on VLAN interface are not dropped
CS00012195261 | [4.3][5.0][TD3]VLAN tagged IP packet received on untagged interface being routed instead of dropped
CS00012183901 | [4.3][WARMBOOT] WARMReboot with active traffic causes port flap reported during warm reboot
CS00012196056 | [4.3.3.8][WARMBOOT] syncd[2584]: segfault at 5616ad6c3d80 ip 00007f61e0c6bc65 sp 00007fff0c5a7a90 error 4 in libsai.so.1.0[7f61e0a95000+3cd8000]
CS00012195262 | [4.3][5.0][TD3] Malformed IP packet(missing IP header) received on a VLAN Interface is flooded to other LVAN members instead of being dropped
CS00012195956 | [4.3.3.8] [TD3]Syncd Crash at brcm_sai_tnl_mp_create_tunnel()
PR 4346163: Add support for AN/LT
```
Why I did it
BIOS upgrade on rare cases cannot guarantee bus value remain the same on every BIOS release. Ignoring this field in order for pcied not to fail but still verify device id in a different way. The solution is future proof and will not require changes in code when new BIOS version is available
How I did it
Since bus is not a fixed value (it is determined by the bios version) we are ignoring this field, and instead checking if there is a device that match on all other fields that and in addition has a matching device id.
How to verify it
Verify no errors or failures in pcied on different BIOS version with the same code base.
- Why I did it
Update SAI version to 1.19.1. The following was changed:
1. Update license
2. Do not remove and re-apply the same SDK mirror session on LAG
3. FEC fix to support all speeds
4. Improve PG counters performance
5. Fix number of switch priorities for port mirroring
Signed-off-by: Dror Prital <drorp@nvidia.com>
Avoid initializing sfp/thermal/components/fan/psu/leds on simx and create vpd_info file on hw_management when we use mellanox simulator platform
- Why I did it
this is a fix for issue in mellanox simulator platforms. the syseepromd failed on the pmon docker. also "decode-syseeprom" failed also
- How I did it
before initializing thermal/components/fan/psu/leds --> check if we are running on simx
creating the vpd_info on the hw_management folder.
- How to verify it
check if syseepromd process was loaded properly on the pmon docker.
decode-syseeprom is working well without errors/warnings
- Why I did it
to prevent python exception error when executing warm-reboot command on mellanox simulator platform
- How I did it
return None on the watchdog python script on cases that watchdog file is not exist
- How to verify it
warm-reboot is running well without the python error. error message will appear on log on these cases.
in order to avoid this error message we can simulate the watchdog on mellanox simulator platform