Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Why I did it
Added support for the device S5224F
How I did it
Implemented the support for the platform S5224F
Switch Vendor: DellEMC
Switch SKU: S5224F-ON
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform/interface commands
Why I did it
Added support for the device N3248PXE
How I did it
Implemented the support for the platform N3248PXE
n3248pxe_unit_test_log.txt
Switch Vendor: DellEMC
* Switch SKU: N3248PXE
* ASIC Vendor: Broadcom
* SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform commands
Why I did it
Added support for the device N3248TE
How I did it
Implemented the support for the platform N3248TE
Switch Vendor: DellEMC
Switch SKU: N3248TE
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform commands
This PR aims to fix the healthd crash issue by adding system health monitoring configuration file for platform Celestica E1031 by adding a new configuration file under the path device/celestica/x86_64-cel_e1031-r0/.
How to verify it
I manually restart the system-health.service and confirmed that healthd is running.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
What I did:
add platform components
How I did it:
In platform_components.json add chassis and empty component
How to verify it:
Run show platform firmware updates
- Why I did it
Removed 2x40G for SN3800. This mode is not supported by hardware.
- How I did it
Removing it from hwsku.json and platform.json
- How to verify it
Load it in the device and check supported modes
Why I did it
Fix an issue on the Clearwater2 linecard.
When the linecard is started with a fresh image without configuration, phys would not be initialized.
How I did it
Added default_sku for Clearwater2 which prevents config-setup from failing to create a default config_db.json.
Added some extra logic in the phy-credo-init script to run the phy_config.sh of the hwsku pointed by default_sku if the DEVICE_METADATA.localhost.hwsku information is not populated in CONFIG_DB.
How to verify it
Booting an image with this change and without configuration will lead to the phys being initialized using the phy_config.sh from default_sku.
What I did it
Add new platform x86_64-ragile_ra-b6910-64c-r0 (Tomahawk 3)
ASIC Vendor: Broadcom
Switch ASIC: Tomahawk 3
Port Config: 64x100G
-How I did it
Provide device and platform related files.
-How to verify it
show platform fan
show platform ssdhealth
show platform psustatus
show platform summary
show platform syseeprom
show platform temperature
show interface status
- Why I did it
SN4600 A0 platform was EOL, so there is no need to support it, sensor conf can be removed and we don't need to maintain 2 sensor conf files, only A1 platform is needed.
- How I did it
Remove get_sensors_conf_path which intends to load correct sensor conf for different(A0/A1) platforms.
Remove the sensor conf for A0 platform, rename previous sensor.conf.a1 to sensor.conf
- How to verify it
Run sensor test on the SN4600 platform.
- Disable health monitoring of `psu.voltage` until support is implemented
- chassis: disable provisioning bit once linecard has booted
- chassis: fix issue in `show version` when running as `admin`
- chassis: fix race when reading an eeprom before it's available
- chassis: implement `get_all_asics` call
- api: fix `ChassisBase.get_system_eeprom_info` implementation
- api: add missing thermal condition and info
- api: fix return value of `ChassisBase.set_status_led`
- sfp: introduce SfpOptoeBase implementation used based on configuration knob
- psu: rely on pmbus to read input/output status when other mechanism is missing
- misc: other refactors and improvements
Why I did it
End goal: To have azure pipeline job to run multi-asic VS tests.
Intermediate goal: Require multi-asic KVM image so that the test can be run.
The difference between single asic and multi-asic KVM image is asic.conf file which has different NUM_ASIC values.
Idea behind the approach in this PR to attain the intermediate goal above:
Ease of building multi-asic KVM image so that any user or azure pipeline can use a simple make command to generate single or multi-asic KVM images as required.
Use a single onie installer image and multiple KVM images for single and multi-asic images.
Current scenario:
For VS platform, sonic-vs.bin is generated which is the onie installer image and sonic-vs.img.gz is generated which is the KVM iamge.
Scenario to be achieved:
sonic-vs.bin - which will include single asic platform, 4 asic platform and 6 asic platform.
sonic-vs.img.gz - single asic KVM image
sonic-4asic-vs.img.gz - 4 asic KVM image
sonic-6asic-vs.img.gz - 6 asic KVM image
In this PR, 2 new platforms are added for 4-asic and 6-asic VS.
How I did it
Create 4-asic and 6-asic device directories with the required files and hwsku files.
Add onie-recovery image information in vs platform.
How to verify it
After this PR change, no build change.
sonic-vs.bin onie installer image should include information of new multi-asic vs platforms.
Why I did it
The first 4 ports on this dut are breakout ports. They might not always be connected in lab. Mark them as 'RJ45' to skip the SFP check since they are by default disabled.
How to verify it
run platform test_reboot.py
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- Why I did it
Update platform data files for SN4800 to support chassis management
- How I did it
Update pcie.yml
Update sensors.conf
Update platform.json
- How to verify it
Run platform test suite in sonic-mgmt
- Why I did it
The MSN4410 platform was missing 2x100G and 4x50G supported breakout modes in platform.json
- How I did it
Added the aforementioned breakout modes to platform.json
- How to verify it
Run show interface breakout on a MSN4410 and verify that 2x100G and 4x50G are listed in the supported breakout modes for ports 1-24.
This change introduces 3 columns in the port_config.ini file.
These are coreId, corePortId and numVoq.
The ports for inband and recirc were also renamed properly.
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Why I did it
The SFP1 port was disabled in the default configuration.
How I did it
This commit enables the 10G front port for usage.
This was done using a DX030 together with an Arista switch using bcmsh and phy diag xe0 dsc to figure out what lane mappings make sense.
Validated on Celestica Seastone2 DX030.
How to verify it
Own a Celestica DX030
Connect the front SFP1 port to something.
It works :-)
You can do tcpdump -i Ethernet128 -n and you will see both incoming and outgoing LLDP.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
To support dynamic port breakout Broadcom configurations on Arista platforms.
How I did it
Updated platform.json for platforms and added new hwsku, Broadcom config, and hwsku.json for dynamic port breakout usage.
The name of the new hwsku name used is very similar to the platform name (platform x86_64-arista_7050_qx32s hwsku Arista-7050QX-32S) as the flex hwsku is meant to be the default in the future.
How to verify it
Boot up device with the new hwsku, interfaces are up.
Change hwsku.json with new default breakout mode and reload device, breakout will have successfully been applied.
#### Why I did it
The values of the syseeprom were not valid
#### How I did it
I took the correct hexdump values from a real switch and created this hex file again
#### How to verify it
decode-syseeprom will display the new values
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
* add hwsku.json for the Nokia-7215
* added required default_brkout_mode to hwsku as its not optional
* remove tabs from the file so spacing consistent
Co-authored-by: Carl Keene <keene@nokia.com>
#### Why I did it
New SN410 A1 system has a different sensor layout with A0 system, needs a new sensor conf file to support it.
#### How I did it
Since the SN4410 A1 system use exactly the same sensor layout as the SN4700 A1 system, so add a symbol link linking to the SN4700 A1 sensor conf file to reuse.
#### How to verify it
Run sensor test against the SN4410 A1 system;
Run platform related regression test against the SN4410 A1 system
Co-authored-by: Arun LK <Arun_L_K@dell.com>
Why I did it
Support for show system-health command in s5232f
How I did it
Added the configuration, API changes to support system health
How to verify it
Execute "show system-health summary/detail/monitor-list" CLI.
* Update default cable len to 0m for TD2 (#8298)
* Update sonic-cfggen tests with the correct cable len
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
- With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Cfggen tests passed with the cable len update
Why I did it
To support "pcied" and "pcieutil" commands in DellEMC Z9332f.
How I did it
Add 'pcie.yaml' in device/dell/[PLATFORM]/ directory.
How to verify it
Execute "pcieutil check" command.
Logs: UT_logs.txt
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Improve chassis linecard restartability
- Fix 'show system-health' cli by adding non standard api
- Fix ledd crash on linecards with Recycle/Inband ports
- Refactor DPM management and add ADM1266 support
- Add state machine to update DPM RTC clock periodically
- Improve xcvr temperature reporting
- Fix lane mapping and `default_sku` for `x86_64-arista_7170_32c` platform
- Fix `7170-32C/CD` platform definition