Why I did it
Provide onie image install verification
How I did it
Add devices folder based on platform_asic and check if current platform inside the list
How to verify it
In onie env, install a bin image which differs the running platform's ASIC. For example;
install sonic-broadcom.bin to mellanox ASIC platform
install sonic-vs.bin to broadcom ASIC platform
Why I did it
"chassis_db_init" task of PMON should be skipped on Mellanox simx platform, since the hardware info which this task is trying to access is not available on simx platforms, It will introduce some error log.
How I did it
Add the capability for "chassis_db_init" in the template for it can be skipped by adding configuration in "pmon_daemon_control.json".
add "skip_chassis_db_init" configuration for simx platforms.
use symbol link for "pmon_daemon_control.json" since all the simx platforms share the same configuration
How to verify it
Build an image and install it on simx platform to check whether "chassis_db_init" task is skipped.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
8bb9c5a (HEAD -> master, origin/master, origin/HEAD) Add retry reading/setting mux status to simulated y-cable driver (#221)
2ebd786 [sfp-refactor] Add initial support for SFF-8636 in sonic_xcvr (#218)
221fb8a Fix QSFP-DD power class mask (#212)
4598d40 [Y-Cable][Broadcom] upgrade to support Broadcom Y-Cable API to release 1.2 (#217)
0fdd198 [sfp-refactor] Add initial support for SFF-8436 in sonic_xcvr (#215)
a09f5a3 [sfp-refactor] Add new sonic_xcvr package for common transceiver logic (#201)
7ca4f51 Update SFP index definition (#214)
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
Why I did it
Added Support for Alphanetworks SNJ60D0-320F platform
How I did it
Implemented the support for Alphanetworks SNJ60D0-320F platform
Platform: x86_64-alphanetworks_snj60d0_320f-r0
HwSKU: Alphanetworks-SNJ60D0-320F
ASIC: broadcom
ASIC Count: 1
How to verify it
Verified the show command outputs
This pull request will fix bash build break issue when re-build bash.
#### Why I did it
src/bash project using quilt to manage patches, and quilt can't apply patch correctly when cache folder '.pc' is not clean.
#### How I did it
Add command in make file to remove quilt cache folder before apply patches.
#### How to verify it
Re-build bash target target/debs/buster/bash_5.1-2_amd64.deb to validate this fix work.
Pass all UT.
#### Which release branch to backport (provide reason below if selected)
N/A
#### Description for the changelog
Fix bash build break issue when re-build bash.
#### A picture of a cute animal (not mandatory but encouraged)
It is required by stretch/sonic-device-data_1.0-1_all.deb, which is required by docker-sonic-mgmt.gz.
Stretch distribution has old Python 3.5.3.
scandir.close() is new in Python version 3.6.
ref: https://docs.python.org/3/library/os.html#os.scandir.close
Fix the check used to wait for interfaces to come up. The group name in
the supervisor config files has changed from isc-dhcp-relay to
dhcp-relay.
Also, in the wait script, wait 10 additional seconds after the vlans,
port channels, and any interfaces are up. This is because dhcrelay
listens on all interfaces (in addition to port channels and vlans), and
to ensure that it stays in a clean state during runtime, wait some extra
time to make sure that those interfaces are created as well.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
This makes it possible to install the debug symbols if needed. Also install
the package into the debug version of sonic-dhcp-relay container.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
With current code the delay will take place even if simple 'config reload' command executed and this is not desired.
This delay should be used only when fast-rebooting.
How I did it
Change the type of delay to OnBootSec instead of OnActiveSec.
How to verify it
Fast-reboot with this PR and observe the delay.
Run 'config-reload' command and observe no delay is running.
- Why I did it
Bug fix:
bad_param request due to missing parser rest command while running mlxlink
- How I did it
Advance to MFT tool version to 4.17.2-12.
- How to verify it
Manually tested on all mellanox platforms.
#### Why I did it
**Import issue will cause:**
root@sonic:/# sudo sonic-clear arp
failed to import plugin clear.plugins.dhcprelay: No module named 'show_dhcp_relay'
#### How I did it
Fix the import.
#### How to verify it
run sudo sonic-clear arp
Redis 4.0.0b1 has been uploaded to pip as a prerelease version. This
version drops support for Python 2 and only supports Python 3. Because
setup.py is being run, it will use the latest version of a package and
not the latest stable version (which is still 3.5.3).
Therefore, pin the redis package to version 3.5.3, so that it will work
for both Python 2 and 3.
#### How to verify it
Make sure that redis-dump-load for Python 2 builds today.
1. Changes for Generation LC-Graph for packet-based chassis.
2. Added Support Ipv6 Peering on Loopback4096 for voq also
3. Updated asic topology yml files to be offset of slot
4. Made slot_num to take string slot<number> instead of number
5. Consolidated template_dpg_voq_asic.j2 into dpg_asic.j2
6. Remove Loopback4096 from asic topology and parse as dut invertory for
multi-asic
7. Updated topo_facts parsing for asic topology_
8. Internal BGP Session rename from <VoqChassisInternal> to <ChassisInternal> and take switch_type as value.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
- Why I did it
Add NVIDIA Copyright header to "mellanox" files
- How I did it
Add NVIDIA Copyright header as a comment for Mellanox files
- How to verify it
Sanity tests and PR checkers.
Why I did it
Currently the mellanox platform API is validating the file extensions of firmware packages to be installed for basic sanity checking. However, ONIE packages do not have an extension and as such if there is a "." in the name it is taken to be an extension and then fails the sanity check.
How I did it
I removed the check which ensures that ONIE images don't have a file extension.
How to verify it
Name the ONIE updater file 2021.onie and attempt to install it via fwutil install fw 2021.onie --yes
Why I did it
The fwutil update all utility expects the auto_update_firmware method in the Platform API to execute the update_firmware() call and not the install_firmware() call.
How I did it
Changed the method in the mellanox platform API component implementation.
How to verify it
Run fwutil update all with a CPLD update on a Mellanox platform and verify that it properly updates the firmware using the MPFA file.
[write_standby]: Ignore non-auto interfaces
* In the event that `write_standby.py` is used to automatically switchover interfaces when linkmgrd or bgp crashes, ignore any interfaces that are not configured to auto-switch
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
[mux] Update Service Install With SONiC Target
Recent PR grouped all SONiC service into sonic.taget. The install section
of mux.service was not update and this causes delays when using config
reload as the service failed state is not being reset.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
[mux] Start Mux on Only Dual-ToR Platform
mux docker depends on the presence of mux cable hardware and is
supposed to run only Gemini ToRs. This PR change the mux feature
config in order to enable mux docker based on device configuration.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
This PR deletes local-to-buildimage linkmgrd and creates new submodule
pointing to github repo of sonic-linkmgrd.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
During warm reboot, linkmgrd would go away and so heartbeats will
be lost. This would result in standby link son peer ToR to pull the
link active. This is undesirable since we would not create tunnel
from the ToR that is being rebooted to the peer ToR. This PR
implicitly lock the state of the mux if config is not set to auto.
Also, orchagent does not initialize MUX to it hardware state, rather
it initilizes MUX to Unknown state. linkmgrd will detect this situation
and probe MUX state to correct orchagent state.
There a fix for the case when state os switched MUX is delayed. The
PR will poll the MUX for the new state. This is required to update
the state ds and hence create/tear tunnel.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Linkmgrd monitors link status, mux status, and link state. Has
the link becomes unhealthy, linkmgrd will trigger mux switchover
on a standby ToR ensuring uninterrupted service to servers/blades.
This PR is initial implementation of linkmgrd.
Also, docker-mux container hold packages related to maintaining and managing
mux cable. It currently runs linkmgrd binary that monitor and switches
the mux if needed.
This PR also introduces mux-container and starts linkmgrd as startup when
build is configured with INCLUDE_MUX=y
Edit: linkmgrd PR will follow.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Related work items: #2315, #3146150
-- Based on the new BCM configuration, Modify the portcoreid for the front panel port in the port_config.ini for line card Nokia-IXR7250e-36x400G
-- Correct the pcie.pmal file
-- Update the platform_ndk.json with new field "update-asic-pvt"
-- Add chassis-internal-intf to chassisdb.conf
-- update platform_reboot
Signed-off-by: mlok <marty.lok@nokia.com>
The default ethernet port naming style is Ethernet0, Ethernet4...Ethernet(i*4) which isn't compatible with EOS's style Ethernet1,Ethernet2...Etherent(i+1)
SONiC-mgmt usually use EOS as neighbor devices. To relieve the compatible issue on SONiC as neighbor devices, This PR introduces a new SKU SONiC VM.
Signed-off-by: Ze Gan <ganze718@gmail.com>
copp-config service needs to be started after sonic.target so that it could
render the copp-config with the latest information.
It also needs to be restarted when config reload or load_minigraph is invoked.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
This pull request extract tacacs support functions into library to share TACACS config file parse code with other project. Also fix memory leak issue in parse config code.
Why I did it
To support TACACS per command authorization, we need reuse the TACACS config file parse code in bash plugin project.
How I did it
Add libtacsupport.pc.in to extract tacacs support functions into library.
Fix memory leak issue in TACACS config parse code by convert the dynamic memory allocation memory to static memory allocation.
How to verify it
Pass all current UT.
Check shared library generated manually.
Which release branch to backport (provide reason below if selected)
N/A
Description for the changelog
Extract tacacs support functions into library, this will share TACACS config file parse code with other project.
Also fix memory leak issue in parse config code.
Since database.service has been moved to execute after rc-local.service,
and determine-reboot-cause.service rely on database.service, we have to
specify that in "After=".
Signed-off-by: Xichen Lin <xichenlin@microsoft.com>
Co-authored-by: Xichen Lin <xichenlin@microsoft.com>
* To add portchannel support in frrcfgd and bgpcfgd
* Update is_zero_ip() to handle portchannel name
Signed-off-by: d-dashkov <Dmytro_Dashkov@Jabil.com>