* [bgpcfgd]: Batch bgp updates.
vtysh -f command is slow. It is sometimes takes about 3 seconds.
When we need to run many vtysh -f commands that slows down the system.
Batch vtysh -f updates.
* Use correct file to import run_command
Added new flag value 'always_enabled' for the state and auto-restart field of feature table
init_cfg.json is updated to initialize state field of database/swss/syncd/teamd feature and auto-restart field of database feature
as always_enabled
Once the state/auto-restart value is initialized as "always_enabled" it is immutable and cannot be change via feature config commands. (config feature..) PR#Azure/sonic-utilities#1271
hostcfgd will not take any action if state field value is 'always_enabled'
Since we have always_enabled field for auto-restart updated supervisor-proc-exit-listener
not to have special check for database and always rely on value from Feature table.
- Why I did it
frr is creating /var/log/frr/frr.log inside the frr docker and letting it grow. It will eventually exhaust hard drive space.
To fixe issue #5965
- How I did it
Remove rsyslog file outchannel so that frr won't generate /var/log/frr/frr.log inside the docker.
- How to verify it
Manually removed the outchannel and restart BGP docker, making sure that /var/log/frr/frr.log is no longer created inside the docker.
While restarting bgp docker, observed that base image /var/log/quagga/bgpd.log continued to grow and captured all FRR logs.
When forced mgmt routes are present, the issue fixed as part of #5754 is not complete.
Added a preference(priority) field to forced mgmt route ip rules
756dd9c8123cd06dc581d9b2eb236334deee1850 (HEAD -> 201911, origin/201911)
[201911 sonic-swss] Flushing FDB entries before removing BridgePort (#1516)
e3f22ea6685104a819440ecc0efe89c4bd3a0003 [201911/portsorch] Add
correct stat list for port buffer drop counters (#1509)
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Add explicit default state into the constants.yml
* Enable/disable only peer-groups, available in the config
* Retrieve updates from frr before using configuration
Co-authored-by: Pavel Shirshov <pavel.contrib@gmail.com>
As new hw-mgmt expose the sysfs for PSU fan max speed, we need support max/min speed for PSU fan in mellanox platform API.
Conflicts:
platform/mellanox/mlnx-platform-api/sonic_platform/fan.py
New driver support fetching additional pages from the cable EEPROM.
There are additional information to parse now: RX/TX power, TX bias, TX fault and RX LOS.
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
**- Why I did it**
Converted two SP model to single pool model and modified the buffer size.
**- How I did it**
Changed buffer_default settings for all the DellEMC Z9264f HWSKU's.
**- How to verify it**
Check SP register values in NPU shell.
**- Which release branch to backport (provide reason below if selected)**
Need to be cherry picked for 201911 branch.
HW set qsfp port to reset at default. so need SW to set to normal when boot.
1. Modify cpld driver to invert reset offset value
2. Set to normal when boot.
* Remove 'backend' from device type strings so that backend devices ('BackEndToRRouter' and 'BackEndLeafRouter') are given the same cable lengths as regular device types.
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Treat devices that are ToRRouters (ToRRouters and BackEndToRRouters) the same when rendering templates
Except for BackEndToRRouters belonging to a storage cluster, since these devices have extra sub-interfaces created
Treat devices that are LeafRouters (LeafRouters and BackEndLeafRouters) the same when rendering templates
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Fixed TSA bugs:
1. TSA didn't advertise Loopback ipv6 address
2. TSA and TSB changed BGP dynamic and BGP monitors sessions
**- How to verify it**
Build an image and run on your DUT.
```
admin@str-s6100-acs-1:~$ TSA
System Mode: Normal -> Maintenance
admin@str-s6100-acs-1:~$ vtysh -c 'show bgp ipv4 neighbors 10.0.0.1 advertised-routes'
BGP table version is 6, local router ID is 10.1.0.32, vrf id 0
Default local pref 100, local AS 64601
Status codes: s suppressed, d damped, h history, * valid, > best, = multipath,
i internal, r RIB-failure, S Stale, R Removed
Nexthop codes: @NNN nexthop's vrf id, < announce-nh-self
Origin codes: i - IGP, e - EGP, ? - incomplete
Network Next Hop Metric LocPrf Weight Path
*> 10.1.0.32/32 0.0.0.0 0 32768 i
Total number of prefixes 1
admin@str-s6100-acs-1:~$ vtysh -c 'show bgp ipv6 neighbors fc00::a advertised-routes'
BGP table version is 6, local router ID is 10.1.0.32, vrf id 0
Default local pref 100, local AS 64601
Status codes: s suppressed, d damped, h history, * valid, > best, = multipath,
i internal, r RIB-failure, S Stale, R Removed
Nexthop codes: @NNN nexthop's vrf id, < announce-nh-self
Origin codes: i - IGP, e - EGP, ? - incomplete
Network Next Hop Metric LocPrf Weight Path
*> fc00:1::/64 :: 0 32768 i
Total number of prefixes 1
admin@str-s6100-acs-1:~$ TSB
System Mode: Maintenance -> Normal
```
Co-authored-by: Pavel Shirshov <pavel.contrib@gmail.com>
To make Control plane ACLs handle case insensitive ACL rules. Currently, it handles only upper case ACL rules.
Co-authored-by: Madhan Babu <madhan@arc-build-server.mtr.labs.mlnx>
- Why I did it
Update the routine is_bgp_session_internal() by checking the BGP_INTERNAL_NEIGHBOR table.
Additionally to address the review comment #5520 (comment)
Add timer settings as will in the internal session templates and keep it minimal as these sessions which will always be up.
Updates to the internal tests data + add all of it to template tests.
- How I did it
Updated the APIs and the template files.
- How to verify it
Verified the internal BGP sessions are displayed correctly with show commands with this API is_bgp_session_internal()
* Initial commit for BGP internal neighbor table support.
> Add new template named "internal" for the internal BGP sessions
> Add a new table in database "BGP_INTERNAL_NEIGHBOR"
> The internal BGP sessions will be stored in this new table "BGP_INTERNAL_NEIGHBOR"
* Changes in template generation tests with the introduction of internal neighbor template files.
In multi asic platforms the "show ip bgp summary" commands is not available for user with read only privileges, so to fix this the vtysh command with the new "-n" option, added for multi asic platforms, needs to be added to the READ_ONLY_COMMANDS list in the sudoers files. Added the command vtysh -n [0-9] -c show * to list of READ_ONLY_COMMANDS in the sudoers files in this commit.
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
API getMount() API was not updated to handle multi-asic platforms
Updated API getMount() to return abspath() for Docker Mount Point
and use that one for mount point comparison
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Some platforms don't leverage the brcm led coprocessor.
However ledinit will try to load a non existing file and exit with an
error code.
This change is a cosmetic fix mostly.
- How to verify it
Boot a platform without the configuration and verify in the syslog that the exit status of ledinit is 0
Boot a platform with the configuration and verify in the syslog that the exit status of ledinit is 0 and the leds are working.
Verified by adding a dumb led_proc_init.soc on an Arista platform which usually doesn't use it.
Our use case is to register new features in runtime. The previous change which introduced the cache broke this capability and caused hostcfgd crash.
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
- Fix bug: `CORE_FILE_DIR` previously was set to `os.path.basename(__file__)`, which would resolve to the script name. Fix this by hardcoding to `/var/core/`
- Remove locally-define logging functions; use Logger class from sonic-py-common instead
Increase startretires value from default of 10 to 50 to prevent supervisor from placing thermalctld in FATAL state during regression testing. Also ensures supervisord tries hard to get thermalctld running in production, as thermalctld is critical to prevent device from overheating.
Update SDK 4.4.1956 and FW *.2008.1956
Bugs fixes:
1. Link | Clear operational speed when link is not active
2. Spectrum-2, SN3800 | On rare occasion, link flapping due to bad BER causes traffic loss
3. Spectrum-3 | On rare occasion, link flapping due to bad BER causes traffic loss as a result of new PAM4 link maintenance flow on Spectrum-3 devices
4. Shared Buffers | On rare occasion, modifying shared buffers on a system with split port while traffic is running may cause the firmware to get stuck
5. Spectrum-3, SN4700 | Fence may fail while running 400GbE 8x port when modifying mirror session configurations under traffic