For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
Why I did it
The SOC property changes are necessary to match #10519 which increases the number of system LAG IDs to 1024.
Description for the changelog
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
Why I did it
This linecard runs in multi-asic mode and therefore needs the use_pcie_id_chassis file to work properly.
The default_sku file was also missing which would break the boot when no minigraph is provided.
Description for the changelog
Add missing default_sku and use_pci_id_chassis configs for 7800R3A-36D2
Why I did it:
To fix hlx platform sfp+ module tx disable issue
How I did it:
Fix sfp+ tx disable function according SFF-8472 specification
Co-authored-by: Eric Zhu <erzhu@celestica.com>
- Why I did it
Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario
This is to port #11032 and #11299 from 202012 to master.
Support additional queue and PG in buffer templates, including both traditional and dynamic model
Support mapping DSCP 2/6 to lossless traffic in the QoS template.
Add macros to generate additional lossless PG in the dynamic model
Adjust the order in which the generic/dedicated (with additional lossless queues) macros are checked and called to generate buffer tables in common template buffers_config.j2
Buffer tables are rendered via using macros.
Both generic and dedicated macros are defined on our platform. Currently, the generic one is called as long as it is defined, which causes the generic one always being called on our platform. To avoid it, the dedicated macrio is checked and called first and then the generic ones.
Support MAP_PFC_PRIORITY_TO_PRIORITY_GROUP on ports with additional lossless queues.
On Mellanox-SN4600C-C64, buffer configuration for t1 is calculated as:
40 * 100G downlink ports with 4 lossless PGs/queues, 1 lossy PG, and 3 lossy queues
16 * 100G uplink ports with 2 lossless PGs/queues, 1 lossy PG, and 5 lossy queues
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Support new platform SN2201 and RJ45 port
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* remove unused import and redundant function
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* fix error introduced by rebase
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* Revert the special handling of RJ45 ports (#56)
* Revert the special handling of RJ45 ports
sfp.py
sfp_event.py
chassis.py
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove deadcode
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Support CPLD update for SN2201
A new class is introduced, deriving from ComponentCPLD and overloading _install_firmware
Change _install_firmware from private (starting with __) to protected, making it overloadable
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Initialize component BIOS/CPLD
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove swb_amb which doesn't on DVT board any more
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove the unexisted sensor - switch board ambient - from platform.json
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Do not report error on receiving unknown status on RJ45 ports
Translate it to disconnect for RJ45 ports
Report error for xSFP ports
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Add reinit for RJ45 to avoid exception
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Co-authored-by: Stephen Sun <5379172+stephenxs@users.noreply.github.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Improve throughput and latency for 7260 deployments
How I did it
Update the dynamic threshold to 0 and ECN settings as 2mb/10mb/5%
How to verify it
Updated unit tests to use the modified values for 7260 ecn settings.
* [device]: Add SAI checksum verify to TD3 config
* A new config option was added to control the value of IPV4_INCR_CHECKSUM_ORIGINAL_VALUE_VERIFY in the EGR_FLEX_CONFIG control register (this prevents checksums of 0xffff from being propagated to other devices)
Why I did it
This was an ask by Microsoft to provide:
7260 config.bcm file for hardware sku Arista-7260CX3-D92C16 (Named Arista-7260CX3-D96C16).
There are 16 100G uplinks:
Ethernet13-20/1
Ethernet45-52/1
All other ports are breakout to 2 50G ports.
How I did it
Copied existing Arista-7260CX3-D108C8 HWSKU and altered the bcm.config and port_config.ini files.
How to verify it
The new 100G ports do come up with a 201811 image using this HWSKU.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR
How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: bingwang <bingwang@microsoft.com>
Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950
SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64
How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.
For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7
How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
* [Tunnel PFC] Tests for adding property 'sai_remap_prio_on_tnl_egress'
Add tests for adding property 'sai_remap_prio_on_tnl_egress', this
property should only be added in dual tor environment.
Test done:
Run test test_j2files.py
Co-authored-by: richardyu <richardyu@contoso.com>
- Why I did it
1. SN2201 sai profile needs to be updated according to the latest hardware.
2. In the reboot script, need to use the common symbol link of the power_cycle sysfs instead of directly accessing it due to SN2201 sysfs is different than other platforms.
3. echo 1 > $SYSFS_PWR_CYCLE will trigger the reboot immediately, the following sleep 3 and echo 0 > $SYSFS_PWR_CYCLE will never be executed, can be removed.
- How I did it
1. Replace the SN2201 sai profile with the latest one.
2. In the platform_reboot script, replace the direct sysfs path with the symbol link path.
3. Remove the redundant code from platform_reboot
- How to verify it
Perform reboot on all the Nvidia platforms, and check all can be rebooted successfully.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* [Tunnel PFC] Add property for tunnel PFC
Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2
* Removed unused default_config.json
* Remove asic.conf file from HW SKUs directories as they are not used by upstream code
* Enable dynamic PCI ID identification on Otterlake2
Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
What/Why I did:
Issue1: By setting up of ipvlan interface in interface-config.sh we are not tolerant to failures. Reason being interface-config.service is one-shot and do not have restart capability.
Scenario: For example if let's say database service goes in fail state then interface-services also gets failed because of dependency check but later database service gets restart but interface service will remain in stuck state and the ipvlan interface nevers get created.
Solution: Moved all the logic in database service from interface-config service which looks more align logically also since the namespace is created here and all the network setting (sysctl) are happening here.With this if database starts we recreate the interface.
Issue 2: Use of IPVLAN vs MACVLAN
Currently we are using ipvlan mode. However above failure scenario is not handle correctly by ipvlan mode. Once the ipvlan interface is created and ip address assign to it and if we restart interface-config or database (new PR) service Linux Kernel gives error "Error: Address already assigned to an ipvlan device." based on this:https://github.com/torvalds/linux/blob/master/drivers/net/ipvlan/ipvlan_main.c#L978Reason being if we do not do cleanup of ip address assignment (need to be unique for IPVLAN) it remains in Kernel Database and never goes to free pool even though namespace is deleted.
Solution: Considering this hard dependency of unique ip macvlan mode is better for us and since everything is managed by Linux Kernel and no dependency for on user configured IP address.
Issue3: Namespace database Service do not check reachability to Supervisor Redis Chassis Server.
Currently there is no explicit check as we never do Redis PING from namespace to Supervisor Redis Chassis Server. With this check it's possible we will start database and all other docker even though there is no connectivity and will hit the error/failure late in cycle
Solution: Added explicit PING from namespace that will check this reachability.
Issue 4:flushdb give exception when trying to accces Chassis Server DB over Unix Sokcet.
Solution: Handle gracefully via try..except and log the message.
Why I did it
add celestica belgite platform
How I did it
add belgite platform in celestica
Co-authored-by: nicwu-cel <nicwu@celestica.com>
Co-authored-by: anjian <anjian@celestica.com>
Co-authored-by: sandycelestica <sandyli@celestica.com>
- Why I did it
Platform_reboot files for simx doesn't do aything different apart from calling /sbin/reboot. which is anyway done in the /usr/local/bin/reboot script i.e. the parent script which calls the platform specific reboot scripts if present.
Moreover, /sbin/reboot invoked in the platform specific reboot script is a non-blocking call and thus it returns back to the original script (although /sbin/reboot does it job in the background) and we see messages like this.
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
Why I did it
To include ONIE version in show platform firmware status command output in DellEMC S6100 and Z9332f platforms.
How I did it
Include ‘ONIE’ in the list of components provided by platform APIs in DellEMC S6100 and Z9332f.
Unmount ONIE-BOOT if mounted using fast/soft/warm-reboot plugins in DellEMC S6100.
Why I did it
Fixes some pmon errors/warnings by providing missing configuration files
How I did it
Add missing pcie.yaml and sensors.conf for supported linecards
How to verify it
pcie-check should pass
sensors should display proper sensor names
* [PDDF] Rename temp for 7816/7326/7726
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
* Change naming to pddf device
Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
Co-authored-by: ecsonic <ecsonic@edge-core.com>
Why I did it
The customer report of the PCIe Bus Errors upon the SDK initialization of as7816-64x.
How I did it
Based on the internal info and discussion, update "pcie_aspm=off" into ONIE_PLATFORM_EXTRA_CMDLINE_LINUX of installer.conf to resolve it.
Why I did it
The buffer pool & profile setting in buffer template was not correct and caused the errors like the following:
ERR swss#orchagent: :- parseReference: malformed reference:[BUFFER_PROFILE|ingress_lossless_profile]. Must not be surrounded by [ ]
How I did it
Fix the buffer pool & profile setting by removing "[]".
How to verify it
Loaded image with this fix in a switch and made sure the error was not seen anymore.