- Why I did it
Added the fwtrace config files in order to be able to call the mlxstrace utility during the show techsupport dump.
Work item tracking
Microsoft ADO (number only):
- How I did it
Added fwtrace config files. Added path to these files to sai.profile for each mlnx device.
- How to verify it
Execute the show techsupport command and check if mlxstrace output is in system dump.
Signed-off-by: vadymhlushko-mlnx <vadymh@nvidia.com>
- Why I did it
Remove obsolete parameter that enables static VXLAN src port range
provide functionality no generate json config file according to appropriate parameter in config_db
Done for
SN3800:
• Mellanox-SN3800-D28C50
• Mellanox-SN3800-C64
• Mellanox-SN3800-D28C49S1 (New 10G SKU)
SN2700:
• Mellanox-SN2700-D48C8
- How I did it
Remove SAI_VXLAN_SRCPORT_RANGE_ENABLE=1 from appropriate sai.profile files
Created vxlan.json file and added few params that depends on DEVICE_METADATA.localhost.vxlan_port_range
- How to verify it
File /etc/swss/config.d/vxlan.json should be generated inside swss docker when it restart
[
{
"SWITCH_TABLE:switch": {
"vxlan_src": "0xFF00",
"vxlan_mask": "8"
},
"OP": "SET"
}
]
Signed-off-by: Andriy Yurkiv <ayurkiv@nvidia.com>
- Why I did it
To create SDK dump on Mellanox devices when SDK event has occurred.
- How I did it
Set the SKUs keys needed to initialize the feature in SAI.
- How to verify it
Simulate SDK event and check that dump is created in the expected path.
Calculate pool size in t1 as 24 * downlink port + 8 * uplink port
- Take both port and peer MTU into account when calculating headroom
- Worst case factor is decreased to 50%
- Mellanox-SN2700-C28D8 t0, assume 48 * 50G/5m + 8 * 100G/40m ports
- Mellanox-SN2700 (C32)
- t0: 16 * 100G/5m + 16 * 100G/40m
- t1: 16 * 100G/40m + 16 * 100G/300m
Signed-off-by: Stephen Sun <stephens@mellanox.com>
Co-authored-by: Stephen Sun <stephens@mellanox.com>