The interface renaming logic fails if one interface is missing.
Because of the `set -e` the whole initramfs hook would abort early on
error.
This change fixes the current behavior to make sure missing interfaces
are properly skipped and ensure existing interface are renamed.
Fix the issues #10501 and #9733
If having gearbox, we need:
* add gbsyncd as a peer since swss also has dependency on gbsyncd
* add service gbsyncd to FEATURE table if it is missing
#### Why I did it
Fix several bugs:
1. If one vlan member belongs to multiple vlans, and if any of the vlans is "Tagged" type, we respect the tagged type
2. If one vlan member belongs to multiple vlans, and all of the vlans have no "Tagged" type, we override it to be a tagged member
3. make sure `vlantype_name` is assigned correctly in each iteration
#### How to verify it
1. Test the command line to parse a minigraph and make sure the output does not change.
```
./sonic-cfggen -m minigraph.mlnx20.xml
```
The minigraph is for HwSKU Mellanox-SN2700-D40C8S8.
2. Test on a DUT with HwSKU Mellanox-SN2700-D40C8S8
```
sudo config load_minigraph
show vlan brief
```
Checked the "Port Tagging" column in the output.
sign-off: Jing Zhang zhangjing@microsoft.com
#### Why I did it
As part of the process moving containers from buster to bullseye.
#### How I did it
1. change base image from buster to bullseye.
2. remove unused addition to orchagent run options
#### How to verify it
Tested building locally.
* [build]: Patch debootstrap to not unmount the host's /proc filesystem
Currently, when the final image is being built (sonic-vs.img.gz,
sonic-broadcom.bin, or similar), each invocation of sudo in the
build_debian.sh script takes 0.8 seconds to run and execute the actual
command. This is because the /proc filesystem in the slave container has
been unmounted somehow. This is happening when debootstrap is running,
and it incorrectly unmounts the host's (in our case, the slave
container's) /proc filesystem because in the new image being built,
/proc is a symlink to the host's (the slave container's) /proc. Because
of that, /proc is gone, and each invocation of sudo adds 0.8 seconds
overhead. As a side effect, docker exec into the slave container during
this time will fail, because /proc/self/fd doesn't exist anymore, and
docker exec assumes that that exists.
Debootstrap has fixed this in 1.0.124 and newer, so backport the patch
that fixes this into the version that Bullseye has.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
* [build_debian.sh]: Use eatmydata to speed up deb package installations
During package installations, dpkg calls fsync multiples times (for each
package) to ensure that tht efiles are written to disk, so that if
there's some system crash during package installation, then it is in at
least a somewhat recoverable state. For our use case though, we're
installing packages in a chroot in fsroot-* from a slave container and
then packaging it into an image. If there were a system crash (or even
if docker crashed), the fsroot-* directory would first be removed, and
the process would get restarted. This means that the fsync calls aren't
really needed for our use case.
The eatmydata package includes a library that will block/suppress the
use of fsync (and similar) system calls from applications and will
instead just return success, so that the application is not blocked on
disk writes, which can instead happen in the background instead as
necessary. If dpkg is run with this library, then the fsync calls that
it does will have no effect.
Therefore, install the eatmydata package at the beginning of
build_debian.sh and have dpkg be run under eatmydata for almost all
package installations/removals. At the end of the installation, remove
it, so that the final image uses dpkg as normal.
In my testing, this saves about 2-3 minutes from the image build time.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
* Change ln syntax to use chroot
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
To sign SONiC kernel image and allow secure boot based system to verify SONiC image before loading into the system.
How I did it
Pass following parameter to rules/config.user
Ex:
SONIC_ENABLE_SECUREBOOT_SIGNATURE := y
SIGNING_KEY := /path/to/key/private.key
SIGNING_CERT := /path/to/public/public.cert
How to verify it
Secure boot enabled system enrolled with right public key of the, image in the platform UEFI database will able to verify image before load.
Alternatively one can verify with offline sbsign tool as below.
export SBSIGN_KEY=/abc/bcd/xyz/
sbverify --cert $SBSIGN_KEY/public_cert.cert fsroot-platform-XYZ/boot/vmlinuz-5.10.0-8-2-amd64 mage
O/P:
Signature verification OK
- Why I did it
Implement newly added reboot causes in PR Azure/sonic-platform-common#277
- How I did it
Map the reboot cause sysfs to the newly added reboot causes.
- How to verify it
manual test, check whether the reboot cause is correct after rebooting the switch in various ways.
run the community reboot test to see whether the reboot cause checker is passing.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
9ac12bf (HEAD -> master, origin/master, origin/HEAD) Fix platform daemon chassisd to handle auto restart on fail (#247)
24fba04 [ycable] fix the logic to update cable_info values when ycable is not present; fix read side logic for ycable (#249)
The v0.7.5 has bug fix for the support of gearbox port and macsec counters. It also includes a owl firmware update with owl.lz4.fw.1.94.0.bin.
How I did it
Update credo sai url for v0.7.5
Update gearbox_config.json with using firmware owl.lz4.fw.1.94.0.bin instead of owl.lz4.fw.1.92.1.bin
How to verify it
Test gearbox port and macsec counter successfully on A7280.
Updating sonic-utilities sub module with the following commits
f09bd31 Fix UT failed cause by change pycommon to use swsscommon
c092300 Increased pcied unit test coverage to > 80%
7d7c85e Modular chassis: Psud set master led on first run
7195dcc Remove py2 from pipeline
c2e7393 [ycabled] increase UT coverage of ycabled daemon
#### Why I did it
When change pycommon to use swsscommon UT failed in sonic-platform-daemon, need submodule update with UT issue fix.
#### How I did it
#### How to verify it
#### Which release branch to backport (provide reason below if selected)
#### Description for the changelog
Fix UT failed cause by change pycommon to use swsscommon
Increased pcied unit test coverage to > 80%
Modular chassis: Psud set master led on first run
Remove py2 from pipeline
[ycabled] increase UT coverage of ycabled daemon
#### A picture of a cute animal (not mandatory but encouraged)
Why I did it
To support address sanitizer for Mellanox syncd
How I did it
/var/log/asan is mapped for syncd container (the same as for swss)
container stop() has a timeout (60s) for syncd (the same as for swss)
This is so libasan has enough time to generate a report.
added ASAN's log path to Mellanox syncd supervisord.conf
added "asan: yes" to sonic_version.yml
How to verify it
Added artificial memory leaks
Compiled with ENABLE_ASAN=y
Installed the image on DUT
Rebooted the DUT
Verified that /var/log/asan/syncd-asan.log contains the leaks
Signed-off-by: Yakiv Huryk <yhuryk@nvidia.com>
- Why I did it
There is a hardware bug that PSU voltage threshold sysfs returns incorrect value. The workaround is to call "sensor -s" to refresh it.
- How I did it
Call "sensor -s" when the threshold value is not incorrect and PSU is "DELTA 1100"
- How to verify it
Unit test and Manual test
Why I did it
Add libgmock-dev to the package list required by linkmgrd unittests.
Required by PR: Azure/sonic-linkmgrd#45
How I did it
Add the package to the package list.
How to verify it
Build docker-mux with KEEP_SLAVE_ON=yes and verify libgmock-dev is present.
Signed-off-by: Longxiang Lyu <lolv@microsoft.com>
This PR includes necessary changes for correct generating BUFFER_QUEUE values in DB. Changes are based on the schema.md
Why I did it
Change format of generating BUFFER_QUEUE in DB according to schema.md and yang-model.
Old format:
"BUFFER_QUEUE": {
"Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
"profile": "profile"
},
"Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
"profile": "profile"
}
},
New format:
"BUFFER_QUEUE": {
"Ethernet0|queue": {
"profile": "profile"
},
"Ethernet0|queue": {
"profile": "profile"
},
"Ethernet4|queue": {
"profile": "profile"
},
"Ethernet4|queue": {
"profile": "profile"
},
"Ethernet8|queue": {
"profile": "profile"
},
"Ethernet8|queue": {
"profile": "profile"
},
...
}
How I did it
Updated structure of buffers_defaults jinja templates.
Signed-off-by: Oleksandr Kozodoi <oleksandrx.kozodoi@intel.com>
Why I did it
[Build]: Fix pip version constraint conflict issue
When a version is specified in the constraint file, if upgrading the version in build script, it will have conflict issue.
How I did it
If a specified version has specified in pip command line, then the version constraint will be skipped.
It upgraded scapy to 2.4.5 in docker-ptf container, after this upgrade, all scripts under ansible/roles/test/files/ptftests will import scapy 2.4.5, some test cases will fail because they are not upgraded accordingly.
Reverts #10507 to avoid breaking regression test.
This reverts commit 92efc01270.
If it is run during image install, it's not guaranteed that the
installation environment will have tune2fs available. Therefore, run it
during initramfs instead.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
* [device config] Adding configuration for default route fallback
* Set sai_tunnel_underlay_route_mode attribute to fallback to default route if more specific route is unavailable.
Why I did it
Config db schema generated by minigraph can’t pass yang validation, PORT table does not have 'lanes' and 'speed' field.
How I did it
Make cfggen command fail when 'lanes' and 'speed' are not provided
How to verify it
Run 'sonic-cfggen -m xxx.xml --print-data' to make sure command fail when 'lanes' and 'speed' not in PORT table
Removed python2 support for sonic-platform-daemons that was causing unit
test errors in sonic_pcied.
* Removed config from docker supervisord jinja templates per VD review comment
* Removed space and python3 per QL comments
Why I did it
Prevent from i2c bus to get locked.
How I did it
Add sysfs driver to access ioport.
Command to reset i2c mux:
echo 1 > /sys/devices/platform/as9716_32d_ioport/i2c_mux_rst
Command to bring i2c mux out of reset:
echo 0 > /sys/devices/platform/as9716_32d_ioport/i2c_mux_rst
Signed-off-by: Brandon Chuang <brandon_chuang@edge-core.com>
Why I did it
In the bringup of tomahawk4/trident4, we realized that such chips need a larger size of /dev/shm in syncd container, so we added the option --shm-size to the docker create for syncd. The default value for shm-size is 64m; after this change, people can add SYNCD_SHM_SIZE=128m to platform_env.conf to change it to 128m.
How to verify it
We verified that after this change, 1) on existing platforms without platform_env.conf, the size of /dev/shm in syncd container (df -h | grep shm) is still the default 64M; 2) after we add SYNCD_SHM_SIZE=128m to platform_env.conf, /dev/shm in syncd becomes 128M.
Why I did it
For trident4/tomahawk4, linux_ngknet.ko and linux_ngknetcb.ko have to be installed. Also, the kernel modules to load on such chips are different from existing ones, so we add an option is_ltsw_chip to determine the kernel modules to load. The option is_ltsw_chip is controlled by adding 'is_ltsw_chip=1' to platform_env.conf or not.
How to verify it
We verified that existing platforms still work after this change; and for platforms with trident4/tomahawk4, we can load the different kernel modules as expected after adding 'is_ltsw_chip=1' to platform_env.conf
Why I did it
Existing dataplane tests cannot be tested under MACsec environment due to the traffic under MACsec link is encrypted. So, I will override the dp_poll of ptf to MACsec dp_poll to decrypt the MACsec packets on injected ports (PR: Azure/sonic-mgmt#5490). MACsec decryption library depends on scapy 2.4.5.
How I did it
Upgrade scapy library to 2.4.5 by pip.
How to verify it
Check the scapy version in docker-ptf by
python -c "import scapy; print(scapy.__version__)"
2.4.5
Signed-off-by: Ze Gan <ganze718@gmail.com>
b67d479 Fixed the sfp refactor issue
827c5a6 Added nokia_cmd command nokia_common grpc support for power down/up SFM module
aeb7f56 Added the nokia cli commands for midplane
c57d083 Fix the get_my_module issue and the thermal_infos exception issue.
0536293 Change the output of "show chassis module status"
63212d7 Enhance the help display for nokia_cmd command
e8d2599 Fix the sonic_install_ndk_service script issue
d52bdcf Add command nokia_cmd show sfm-eeprom support
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
minigraph parser has introduced new type.
How I did it
Update yang models to support BmcMgmtToRRouter.
How to verify it
Run unit test for sonic-yang-models
Signed-off-by: Gang Lv ganglv@microsoft.com
#### Why I did it
As of https://github.com/Azure/sonic-swss-common/pull/587 the blackout issue in ConfigDBConnector has been resolved.
In the past hostcfgd was refactored to use SubscriberStateTable instead of ConfigDBConnector for subscribing to CONFIG_DB updates due to a "blackout" period between hostcfgd pulling the table data down and running the initialization and actually calling `listen()` on ConfigDBConnector which starts the update handler.
However SusbscriberStateTable creates many file descriptors against the redis DB which is inefficient compared to ConfigDBConnector which only opens a single file descriptor.
With the new fix to ConfigDBConnector I refactored hostcfgd to take advantage of these updates.
#### How I did it
Replaced SubscriberStateTable with ConfigDBConnector
#### How to verify it
The functionality of hostcfgd can be verified by booting the switch and verifying that NTP is properly configured.
To check the blackout period you can add a delay in the hostcfgd `load()` function and also add a print statement before and after the load so you know when it occurs. Then restart hostcfgd and wait for the load to start, then during the load push a partial change to the FEATURE table and verify that the change is picked up and the feature is enabled after the load period finishes.
#### Description for the changelog
[hostcfgd] Move hostcfgd back to ConfigDBConnector for subscribing to updates