- Use SfpOptoeBase by default to leverage new `sonic_xcvr` refactor
- Add support for `Woodleaf` product
- Move `libsfp-eeprom.so` to a different `.deb` package
- Add new logrotate configuration for arista logs
- Improve logging mechanism for the drivers (IO loglevel, fix syslog duplicates)
- Initialize chassis cards in parallel
- Refactor of `get_change_event` to fix interrupts treated as presence change
Why I did it
To implement fan control using thermalctld in DellEMC S6000 platform
Requires: Azure/sonic-linux-kernel#241
How I did it
Add thermal policies in 'thermal_policy.json'
Implemented thermal_manager.py and the necessary modules to perform fan control via thermalctld
Removed fancontrol.sh
How to verify it
Verified that the fan speeds are set based on the fan and temperature status.
Logs: S6000_fan_control_test_logs.txt
- Why I did it
Also recalculated all parameters with the latest algorithm with per-speed peer response time taken into account
- How I did it
Detailed information of each SKU:
C64:
t0: 32 100G downlinks and 32 100G uplinks
t1: 56 100G downlinks and 8 100G uplinks with 2km-cable supported
D112C8: 112 50G downlinks and 8 100G uplinks.
D48C40: 48 50G downlinks, 32 100G downlinks, and 8 100G uplinks
D100C12S2: 4 100G downlinks, 2 10G downlinks, 100 50G downlinks, and 8 100G uplinks
2km cable is supported for C64 on t1 only
- How to verify it
Run regression test (QoS)
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
To support iTCO watchdog using watchdog APIs.
How I did it
Implemented a new watchdog class WatchdogTCO for interfacing with iTCO watchdog.
Updated reboot cause determination logic.
How to verify it
Verified that the watchdog APIs' return values are as expected.
Logs: UT_logs.txt
- Why I did it
Add support for SN2201 platform
- How I did it
Add required content for SN2201 platform
Note: still missing kernel driver support for this system. Once all is upstream will be updated as well.
- How to verify it
Install and basic sanity tests including traffic.
Signed-off-by: liora liora@nvidia.com
Signed-off-by: Stephen Sun stephens@nvidia.com
Why I did it
Support zero buffer profiles
Add buffer profiles and pool definition for zero buffer profiles
Support applying zero profiles on INACTIVE PORTS
Enable dynamic buffer manager to load zero pools and profiles from a JSON file
Dependency: It depends on Azure/sonic-swss#1910 and submodule advancing PR once the former merged.
How I did it
Add buffer profiles and pool definition for zero buffer profiles
If the buffer model is static:
Apply normal buffer profiles to admin-up ports
Apply zero buffer profiles to admin-down ports
If the buffer model is dynamic:
Apply normal buffer profiles to all ports
buffer manager will take care when a port is shut down
Update buffers_config.j2 to support INACTIVE PORTS by extending the existing macros to generate the various buffer objects, including PGs, queues, ingress/egress profile lists
Originally, all the macros to generate the above buffer objects took active ports only as an argument
Now that buffer items need to be generated on inactive ports as well, an extra argument representing the inactive ports need to be added
To be backward compatible, a new series of macros are introduced to take both active and inactive ports as arguments
The original version (with active ports only) will be checked first. If it is not defined, then the extended version will be called
Only vendors who support zero profiles need to change their buffer templates
Enable buffer manager to load zero pools and profiles from a JSON file:
The JSON file is provided on a per-platform basis
It is copied from platform/<vendor> folder to /usr/share/sonic/temlates folder in compiling time and rendered when the swss container is being created.
To make code clean and reduce redundant code, extract common macros from buffer_defaults_t{0,1}.j2 of all SKUs to two common files:
One in Mellanox-SN2700-D48C8 for single ingress pool mode
The other in ACS-MSN2700 for double ingress pool mode
Those files of all other SKUs will be symbol link to the above files
Update sonic-cfggen test accordingly:
Adjust example output file of JSON template for unit test
Add unit test in for Mellanox's new buffer templates.
How to verify it
Regression test.
Unit test in sonic-cfggen
Run regression test and manually test.
Why I did it
Fix#9059. It provides common gbsyncd.service.j2 to start for platform specific gbsyncd docker, which must be named 'gbsyncd'.
How I did it
All of platform specific gbsyncd dockers use a common name 'gbsyncd'
Use a unique systemd service template gbsyncd.service.j2 for gbsyncd docker
Signed-off-by: pettershao-ragilenetworks pettershao@ragilenetworks.com
What I did it
Add new platform x86_64-ragile_ra-b6510-32c-r0 (Trident 3)
ASIC Vendor: Broadcom
Switch ASIC: Trident 3
Port Config: 32x100G
Add new platform x86_64-ragile_ra-b6920-4s-r0 (Tomahawk 3)
ASIC Vendor: Broadcom
Switch ASIC: Tomahawk 3
Port Config: 128x100G
-How I did it
Provide device and platform related files.
-How to verify it
show platform fan
show platform ssdhealth
show platform psustatus
show platform summary
show platform syseeprom
show platform temperature
show interface status
Why I did it
For sonic-mgmt Platform API tests to have data to compare with
How I did it
updated platform info for device x86_64-accton_wedge100bf_32x-r0
How to verify it
Run sonic-mgmt Platform API tests get_name fo:
chassis
fans
fan_drawers
psus
thermals
Why I did it
To include capabilities fields in platform.json of DellEMC S6000, S6100, Z9332f platforms.
How I did it
Add the capabilities fields in each platform's respective platform.json.
How to verify it
Ran sonic-mgmt platform api test cases that use capabilities fields and verified that the results are as expected.
- Why I did it
Wrong SKU configuration will lead to longer init flow.
This will affect fast-reboot feature by increasing the traffic downtime.
Since MLNX met the required downtime period with this SKU this bug found with a delay.
- How I did it
Add the required split labels for ports.
- How to verify it
Run fast-reboot with this platform using SN3800-D112C8 SKU.
This commit more fully declares the HW capabilities of the Nokia-7215
platform. For example, support for the threshold values associated with each
thermal sensor is described. The intent here is to inform the sonic-mgmt
platform test cases of which HW features are supported.
This commit must align with PR# 4521 within the sonic-mgmt git repo which is
currently under review. Any changes to that PR will need to be reflected in
this commit.
* [202012][platform/barefoot] (#8543)
Why I did it
Pcied running by python 2.
How I did it
dropped python2 support and add python3 support for pcied in file docker-pmon.supervisord.conf.j2
How to verify it
docker exec pmon supervisorctl status
* [Netberg][nba715] Initial support for Netberg Aurora 715 switch
Signed-off-by: Andrew Sapronov <andrew.sapronov@gmail.com>
Co-authored-by: Kostiantyn Yarovyi <kostiantynx.yarovyi@intel.com>
Adding platform support for centec v682-48y8c_d.
Why I did it
Adding platform support for centec v682-48y8c_d.
This switch has 48 SFP+ (1G/10G/25G) ports, 8 QSFP28 (40G/100G) ports on CENTEC TsingMa.MX.
CPU used in v682-48y8c_d is Intel(R) Xeon(R) CPU D-1527.
How I did it
Modify related code in platform and device directory.
Upgrade sai to v1.8.
fix bug for parallel compile centec platform modules.
How to verify it
Build centec amd64 sonic image, verify platform functions (port, sfp, led etc) on centec v682-48y8c_d board.
Co-authored-by: Shi Lei <shil@centecnetworks.com>
Why I did it
Added Support for Dell EMC S5212f platform
How I did it
Implemented the support for Dell EMC S5212f platform
Platform: x86_64-dellemc_s5212f_c3538-r0
HwSKU: DellEMC-S5212f-P-25G
ASIC: broadcom
ASIC Count: 1
How to verify it
Verified the show command outputs
Why I did it
"chassis_db_init" task of PMON should be skipped on Mellanox simx platform, since the hardware info which this task is trying to access is not available on simx platforms, It will introduce some error log.
How I did it
Add the capability for "chassis_db_init" in the template for it can be skipped by adding configuration in "pmon_daemon_control.json".
add "skip_chassis_db_init" configuration for simx platforms.
use symbol link for "pmon_daemon_control.json" since all the simx platforms share the same configuration
How to verify it
Build an image and install it on simx platform to check whether "chassis_db_init" task is skipped.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Why I did it
Added Support for Alphanetworks SNJ60D0-320F platform
How I did it
Implemented the support for Alphanetworks SNJ60D0-320F platform
Platform: x86_64-alphanetworks_snj60d0_320f-r0
HwSKU: Alphanetworks-SNJ60D0-320F
ASIC: broadcom
ASIC Count: 1
How to verify it
Verified the show command outputs
- Why I did it
Add NVIDIA Copyright header to "mellanox" files
- How I did it
Add NVIDIA Copyright header as a comment for Mellanox files
- How to verify it
Sanity tests and PR checkers.
-- Based on the new BCM configuration, Modify the portcoreid for the front panel port in the port_config.ini for line card Nokia-IXR7250e-36x400G
-- Correct the pcie.pmal file
-- Update the platform_ndk.json with new field "update-asic-pvt"
-- Add chassis-internal-intf to chassisdb.conf
-- update platform_reboot
Signed-off-by: mlok <marty.lok@nokia.com>
The default ethernet port naming style is Ethernet0, Ethernet4...Ethernet(i*4) which isn't compatible with EOS's style Ethernet1,Ethernet2...Etherent(i+1)
SONiC-mgmt usually use EOS as neighbor devices. To relieve the compatible issue on SONiC as neighbor devices, This PR introduces a new SKU SONiC VM.
Signed-off-by: Ze Gan <ganze718@gmail.com>
#### Why I did it
Fixing https://github.com/Azure/sonic-buildimage/issues/8938
Fixing 1x10G DPB mode in Mellanox-SN2700-D40C8S8 SKU as it was causing sonic-cfggen to fail.
#### How I did it
Added correct mode format in hwksu.json in Mellanox-SN2700-D40C8S8 and updated platform.json for the new mode.
#### How to verify it
Using sonic-cfggen verify it works fine
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.
One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.
After this PR merged, each platform vendor has to add one mandatory text file `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.
I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.
You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```
Also support
```
broadcom-dnx
```
#### How I did it
#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Why I did it
Added support for the device S5224F
How I did it
Implemented the support for the platform S5224F
Switch Vendor: DellEMC
Switch SKU: S5224F-ON
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform/interface commands
Why I did it
Added support for the device N3248PXE
How I did it
Implemented the support for the platform N3248PXE
n3248pxe_unit_test_log.txt
Switch Vendor: DellEMC
* Switch SKU: N3248PXE
* ASIC Vendor: Broadcom
* SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform commands
Why I did it
Added support for the device N3248TE
How I did it
Implemented the support for the platform N3248TE
Switch Vendor: DellEMC
Switch SKU: N3248TE
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform commands
This PR aims to fix the healthd crash issue by adding system health monitoring configuration file for platform Celestica E1031 by adding a new configuration file under the path device/celestica/x86_64-cel_e1031-r0/.
How to verify it
I manually restart the system-health.service and confirmed that healthd is running.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
What I did:
add platform components
How I did it:
In platform_components.json add chassis and empty component
How to verify it:
Run show platform firmware updates
- Why I did it
Removed 2x40G for SN3800. This mode is not supported by hardware.
- How I did it
Removing it from hwsku.json and platform.json
- How to verify it
Load it in the device and check supported modes
Why I did it
Fix an issue on the Clearwater2 linecard.
When the linecard is started with a fresh image without configuration, phys would not be initialized.
How I did it
Added default_sku for Clearwater2 which prevents config-setup from failing to create a default config_db.json.
Added some extra logic in the phy-credo-init script to run the phy_config.sh of the hwsku pointed by default_sku if the DEVICE_METADATA.localhost.hwsku information is not populated in CONFIG_DB.
How to verify it
Booting an image with this change and without configuration will lead to the phys being initialized using the phy_config.sh from default_sku.
What I did it
Add new platform x86_64-ragile_ra-b6910-64c-r0 (Tomahawk 3)
ASIC Vendor: Broadcom
Switch ASIC: Tomahawk 3
Port Config: 64x100G
-How I did it
Provide device and platform related files.
-How to verify it
show platform fan
show platform ssdhealth
show platform psustatus
show platform summary
show platform syseeprom
show platform temperature
show interface status
- Why I did it
SN4600 A0 platform was EOL, so there is no need to support it, sensor conf can be removed and we don't need to maintain 2 sensor conf files, only A1 platform is needed.
- How I did it
Remove get_sensors_conf_path which intends to load correct sensor conf for different(A0/A1) platforms.
Remove the sensor conf for A0 platform, rename previous sensor.conf.a1 to sensor.conf
- How to verify it
Run sensor test on the SN4600 platform.
- Disable health monitoring of `psu.voltage` until support is implemented
- chassis: disable provisioning bit once linecard has booted
- chassis: fix issue in `show version` when running as `admin`
- chassis: fix race when reading an eeprom before it's available
- chassis: implement `get_all_asics` call
- api: fix `ChassisBase.get_system_eeprom_info` implementation
- api: add missing thermal condition and info
- api: fix return value of `ChassisBase.set_status_led`
- sfp: introduce SfpOptoeBase implementation used based on configuration knob
- psu: rely on pmbus to read input/output status when other mechanism is missing
- misc: other refactors and improvements
Why I did it
End goal: To have azure pipeline job to run multi-asic VS tests.
Intermediate goal: Require multi-asic KVM image so that the test can be run.
The difference between single asic and multi-asic KVM image is asic.conf file which has different NUM_ASIC values.
Idea behind the approach in this PR to attain the intermediate goal above:
Ease of building multi-asic KVM image so that any user or azure pipeline can use a simple make command to generate single or multi-asic KVM images as required.
Use a single onie installer image and multiple KVM images for single and multi-asic images.
Current scenario:
For VS platform, sonic-vs.bin is generated which is the onie installer image and sonic-vs.img.gz is generated which is the KVM iamge.
Scenario to be achieved:
sonic-vs.bin - which will include single asic platform, 4 asic platform and 6 asic platform.
sonic-vs.img.gz - single asic KVM image
sonic-4asic-vs.img.gz - 4 asic KVM image
sonic-6asic-vs.img.gz - 6 asic KVM image
In this PR, 2 new platforms are added for 4-asic and 6-asic VS.
How I did it
Create 4-asic and 6-asic device directories with the required files and hwsku files.
Add onie-recovery image information in vs platform.
How to verify it
After this PR change, no build change.
sonic-vs.bin onie installer image should include information of new multi-asic vs platforms.
Why I did it
The first 4 ports on this dut are breakout ports. They might not always be connected in lab. Mark them as 'RJ45' to skip the SFP check since they are by default disabled.
How to verify it
run platform test_reboot.py
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- Why I did it
Update platform data files for SN4800 to support chassis management
- How I did it
Update pcie.yml
Update sensors.conf
Update platform.json
- How to verify it
Run platform test suite in sonic-mgmt
- Why I did it
The MSN4410 platform was missing 2x100G and 4x50G supported breakout modes in platform.json
- How I did it
Added the aforementioned breakout modes to platform.json
- How to verify it
Run show interface breakout on a MSN4410 and verify that 2x100G and 4x50G are listed in the supported breakout modes for ports 1-24.
This change introduces 3 columns in the port_config.ini file.
These are coreId, corePortId and numVoq.
The ports for inband and recirc were also renamed properly.
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Why I did it
The SFP1 port was disabled in the default configuration.
How I did it
This commit enables the 10G front port for usage.
This was done using a DX030 together with an Arista switch using bcmsh and phy diag xe0 dsc to figure out what lane mappings make sense.
Validated on Celestica Seastone2 DX030.
How to verify it
Own a Celestica DX030
Connect the front SFP1 port to something.
It works :-)
You can do tcpdump -i Ethernet128 -n and you will see both incoming and outgoing LLDP.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
To support dynamic port breakout Broadcom configurations on Arista platforms.
How I did it
Updated platform.json for platforms and added new hwsku, Broadcom config, and hwsku.json for dynamic port breakout usage.
The name of the new hwsku name used is very similar to the platform name (platform x86_64-arista_7050_qx32s hwsku Arista-7050QX-32S) as the flex hwsku is meant to be the default in the future.
How to verify it
Boot up device with the new hwsku, interfaces are up.
Change hwsku.json with new default breakout mode and reload device, breakout will have successfully been applied.
#### Why I did it
The values of the syseeprom were not valid
#### How I did it
I took the correct hexdump values from a real switch and created this hex file again
#### How to verify it
decode-syseeprom will display the new values
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
* add hwsku.json for the Nokia-7215
* added required default_brkout_mode to hwsku as its not optional
* remove tabs from the file so spacing consistent
Co-authored-by: Carl Keene <keene@nokia.com>
#### Why I did it
New SN410 A1 system has a different sensor layout with A0 system, needs a new sensor conf file to support it.
#### How I did it
Since the SN4410 A1 system use exactly the same sensor layout as the SN4700 A1 system, so add a symbol link linking to the SN4700 A1 sensor conf file to reuse.
#### How to verify it
Run sensor test against the SN4410 A1 system;
Run platform related regression test against the SN4410 A1 system
Co-authored-by: Arun LK <Arun_L_K@dell.com>
Why I did it
Support for show system-health command in s5232f
How I did it
Added the configuration, API changes to support system health
How to verify it
Execute "show system-health summary/detail/monitor-list" CLI.
* Update default cable len to 0m for TD2 (#8298)
* Update sonic-cfggen tests with the correct cable len
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
- With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Cfggen tests passed with the cable len update
Why I did it
To support "pcied" and "pcieutil" commands in DellEMC Z9332f.
How I did it
Add 'pcie.yaml' in device/dell/[PLATFORM]/ directory.
How to verify it
Execute "pcieutil check" command.
Logs: UT_logs.txt
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Improve chassis linecard restartability
- Fix 'show system-health' cli by adding non standard api
- Fix ledd crash on linecards with Recycle/Inband ports
- Refactor DPM management and add ADM1266 support
- Add state machine to update DPM RTC clock periodically
- Improve xcvr temperature reporting
- Fix lane mapping and `default_sku` for `x86_64-arista_7170_32c` platform
- Fix `7170-32C/CD` platform definition
1. Implement FanDrawer-Fan hierarchy.
2. Enable thermalctld, disable pcied.
3. Implement SystemLED in Chassis.
4. Correct Fan direction
5. Implement require Fan APIs for SystemHealthMonitoring.
6. Handle non-ascii character while reading PSU model/serial num.
```
Check if System-health can pass the check and display the SystemLED correctly.
///////// booting, DIAG_LED = GREEN_BLINKING /////////
root@sonic:/tmp# show system-health detail
System is currently booting...
root@sonic:/tmp# cat /sys/class/leds/diag/brightness
5
///////// container_checker fail, DIAG_LED = AMBER /////////
root@sonic:/sys/bus/i2c/devices# show system-health detail
System status summary
System status LED STATUS_LED_COLOR_AMBER
Services:
Status: OK
Hardware:
Status: Not OK
Reasons: container_checker is not Status ok
System services and devices monitor list
Name Status Type
-------------------------- -------- ----------
container_checker Not OK Program
sonic OK System
rsyslog OK Process
root-overlay OK Filesystem
var-log OK Filesystem
routeCheck OK Program
diskCheck OK Program
container_memory_telemetry OK Program
FAN-1F OK Fan
FAN-1R OK Fan
FAN-2F OK Fan
FAN-2R OK Fan
FAN-3F OK Fan
FAN-3R OK Fan
PSU-1 FAN-1 OK Fan
PSU-2 FAN-1 OK Fan
PSU 1 OK PSU
PSU 2 OK PSU
System services and devices ignore list
Name Status Type
--------------- -------- ------
asic Ignored Device
psu.temperature Ignored Device
///////// skip container_checker, DIAG_LED = GREEN /////////
root@sonic:/sys/bus/i2c/devices# vi /usr/share/sonic/device/x86_64-accton_as4630_54te-r0/system_health_monitoring_config.json
root@sonic:/sys/bus/i2c/devices#
root@sonic:/sys/bus/i2c/devices#
root@sonic:/sys/bus/i2c/devices# show system-health detail
System status summary
System status LED STATUS_LED_COLOR_GREEN
Services:
Status: OK
Hardware:
Status: OK
System services and devices monitor list
Name Status Type
-------------------------- -------- ----------
sonic OK System
rsyslog OK Process
root-overlay OK Filesystem
var-log OK Filesystem
routeCheck OK Program
diskCheck OK Program
container_memory_telemetry OK Program
FAN-1F OK Fan
FAN-1R OK Fan
FAN-2F OK Fan
FAN-2R OK Fan
FAN-3F OK Fan
FAN-3R OK Fan
PSU-1 FAN-1 OK Fan
PSU-2 FAN-1 OK Fan
PSU 1 OK PSU
PSU 2 OK PSU
System services and devices ignore list
Name Status Type
----------------- -------- -------
container_checker Ignored Service
psu.temperature Ignored Device
asic Ignored Device
```
Signed-off-by: Sean Wu <sean_wu@edge-core.com>
- Why I did it
To fix failed test cases of Haliburton platform APIs that found on platform_tests script
- How I did it
Add device/celestica/x86_64-cel_e1031-r0/platform.json
Update functions to support python3.7
Add more functions follow latest sonic_platform_base
Fix the bug
- How to verify it
Run platform_tests script
Signed-off-by: Wirut Getbamrung [wgetbumr@celestica.com]
*Edited platform.json for 4600 & 4600C
*Edited hwsku.json and port_config.ini files for all the SKU's present under these platforms
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>