Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Improve throughput and latency for 7260 deployments
How I did it
Update the dynamic threshold to 0 and ECN settings as 2mb/10mb/5%
How to verify it
Updated unit tests to use the modified values for 7260 ecn settings.
* [device]: Add SAI checksum verify to TD3 config
* A new config option was added to control the value of IPV4_INCR_CHECKSUM_ORIGINAL_VALUE_VERIFY in the EGR_FLEX_CONFIG control register (this prevents checksums of 0xffff from being propagated to other devices)
Why I did it
This was an ask by Microsoft to provide:
7260 config.bcm file for hardware sku Arista-7260CX3-D92C16 (Named Arista-7260CX3-D96C16).
There are 16 100G uplinks:
Ethernet13-20/1
Ethernet45-52/1
All other ports are breakout to 2 50G ports.
How I did it
Copied existing Arista-7260CX3-D108C8 HWSKU and altered the bcm.config and port_config.ini files.
How to verify it
The new 100G ports do come up with a 201811 image using this HWSKU.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR
How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: bingwang <bingwang@microsoft.com>
Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950
SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64
How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.
For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7
How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
* [Tunnel PFC] Tests for adding property 'sai_remap_prio_on_tnl_egress'
Add tests for adding property 'sai_remap_prio_on_tnl_egress', this
property should only be added in dual tor environment.
Test done:
Run test test_j2files.py
Co-authored-by: richardyu <richardyu@contoso.com>
- Why I did it
1. SN2201 sai profile needs to be updated according to the latest hardware.
2. In the reboot script, need to use the common symbol link of the power_cycle sysfs instead of directly accessing it due to SN2201 sysfs is different than other platforms.
3. echo 1 > $SYSFS_PWR_CYCLE will trigger the reboot immediately, the following sleep 3 and echo 0 > $SYSFS_PWR_CYCLE will never be executed, can be removed.
- How I did it
1. Replace the SN2201 sai profile with the latest one.
2. In the platform_reboot script, replace the direct sysfs path with the symbol link path.
3. Remove the redundant code from platform_reboot
- How to verify it
Perform reboot on all the Nvidia platforms, and check all can be rebooted successfully.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* [Tunnel PFC] Add property for tunnel PFC
Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2
* Removed unused default_config.json
* Remove asic.conf file from HW SKUs directories as they are not used by upstream code
* Enable dynamic PCI ID identification on Otterlake2
Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
What/Why I did:
Issue1: By setting up of ipvlan interface in interface-config.sh we are not tolerant to failures. Reason being interface-config.service is one-shot and do not have restart capability.
Scenario: For example if let's say database service goes in fail state then interface-services also gets failed because of dependency check but later database service gets restart but interface service will remain in stuck state and the ipvlan interface nevers get created.
Solution: Moved all the logic in database service from interface-config service which looks more align logically also since the namespace is created here and all the network setting (sysctl) are happening here.With this if database starts we recreate the interface.
Issue 2: Use of IPVLAN vs MACVLAN
Currently we are using ipvlan mode. However above failure scenario is not handle correctly by ipvlan mode. Once the ipvlan interface is created and ip address assign to it and if we restart interface-config or database (new PR) service Linux Kernel gives error "Error: Address already assigned to an ipvlan device." based on this:https://github.com/torvalds/linux/blob/master/drivers/net/ipvlan/ipvlan_main.c#L978Reason being if we do not do cleanup of ip address assignment (need to be unique for IPVLAN) it remains in Kernel Database and never goes to free pool even though namespace is deleted.
Solution: Considering this hard dependency of unique ip macvlan mode is better for us and since everything is managed by Linux Kernel and no dependency for on user configured IP address.
Issue3: Namespace database Service do not check reachability to Supervisor Redis Chassis Server.
Currently there is no explicit check as we never do Redis PING from namespace to Supervisor Redis Chassis Server. With this check it's possible we will start database and all other docker even though there is no connectivity and will hit the error/failure late in cycle
Solution: Added explicit PING from namespace that will check this reachability.
Issue 4:flushdb give exception when trying to accces Chassis Server DB over Unix Sokcet.
Solution: Handle gracefully via try..except and log the message.
Why I did it
add celestica belgite platform
How I did it
add belgite platform in celestica
Co-authored-by: nicwu-cel <nicwu@celestica.com>
Co-authored-by: anjian <anjian@celestica.com>
Co-authored-by: sandycelestica <sandyli@celestica.com>
- Why I did it
Platform_reboot files for simx doesn't do aything different apart from calling /sbin/reboot. which is anyway done in the /usr/local/bin/reboot script i.e. the parent script which calls the platform specific reboot scripts if present.
Moreover, /sbin/reboot invoked in the platform specific reboot script is a non-blocking call and thus it returns back to the original script (although /sbin/reboot does it job in the background) and we see messages like this.
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
Why I did it
To include ONIE version in show platform firmware status command output in DellEMC S6100 and Z9332f platforms.
How I did it
Include ‘ONIE’ in the list of components provided by platform APIs in DellEMC S6100 and Z9332f.
Unmount ONIE-BOOT if mounted using fast/soft/warm-reboot plugins in DellEMC S6100.
Why I did it
Fixes some pmon errors/warnings by providing missing configuration files
How I did it
Add missing pcie.yaml and sensors.conf for supported linecards
How to verify it
pcie-check should pass
sensors should display proper sensor names
* [PDDF] Rename temp for 7816/7326/7726
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
* Change naming to pddf device
Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
Co-authored-by: ecsonic <ecsonic@edge-core.com>
Why I did it
The customer report of the PCIe Bus Errors upon the SDK initialization of as7816-64x.
How I did it
Based on the internal info and discussion, update "pcie_aspm=off" into ONIE_PLATFORM_EXTRA_CMDLINE_LINUX of installer.conf to resolve it.
Why I did it
The buffer pool & profile setting in buffer template was not correct and caused the errors like the following:
ERR swss#orchagent: :- parseReference: malformed reference:[BUFFER_PROFILE|ingress_lossless_profile]. Must not be surrounded by [ ]
How I did it
Fix the buffer pool & profile setting by removing "[]".
How to verify it
Loaded image with this fix in a switch and made sure the error was not seen anymore.
The v0.7.5 has bug fix for the support of gearbox port and macsec counters. It also includes a owl firmware update with owl.lz4.fw.1.94.0.bin.
How I did it
Update credo sai url for v0.7.5
Update gearbox_config.json with using firmware owl.lz4.fw.1.94.0.bin instead of owl.lz4.fw.1.92.1.bin
How to verify it
Test gearbox port and macsec counter successfully on A7280.
- Why I did it
There is a hardware bug that PSU voltage threshold sysfs returns incorrect value. The workaround is to call "sensor -s" to refresh it.
- How I did it
Call "sensor -s" when the threshold value is not incorrect and PSU is "DELTA 1100"
- How to verify it
Unit test and Manual test
This PR includes necessary changes for correct generating BUFFER_QUEUE values in DB. Changes are based on the schema.md
Why I did it
Change format of generating BUFFER_QUEUE in DB according to schema.md and yang-model.
Old format:
"BUFFER_QUEUE": {
"Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
"profile": "profile"
},
"Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
"profile": "profile"
}
},
New format:
"BUFFER_QUEUE": {
"Ethernet0|queue": {
"profile": "profile"
},
"Ethernet0|queue": {
"profile": "profile"
},
"Ethernet4|queue": {
"profile": "profile"
},
"Ethernet4|queue": {
"profile": "profile"
},
"Ethernet8|queue": {
"profile": "profile"
},
"Ethernet8|queue": {
"profile": "profile"
},
...
}
How I did it
Updated structure of buffers_defaults jinja templates.
Signed-off-by: Oleksandr Kozodoi <oleksandrx.kozodoi@intel.com>
* [device config] Adding configuration for default route fallback
* Set sai_tunnel_underlay_route_mode attribute to fallback to default route if more specific route is unavailable.
Why I did it
Prevent from i2c bus to get locked.
How I did it
Add sysfs driver to access ioport.
Command to reset i2c mux:
echo 1 > /sys/devices/platform/as9716_32d_ioport/i2c_mux_rst
Command to bring i2c mux out of reset:
echo 0 > /sys/devices/platform/as9716_32d_ioport/i2c_mux_rst
Signed-off-by: Brandon Chuang <brandon_chuang@edge-core.com>
Why I did it
Support pddf to as4630/as7816/as7326
How I did it
Send needed file to the PR for these platform
How to verify it
Test sensors and show platform cmd.
root@as7326-56x-3:/home/admin# show platform psustatus
PSU Model Serial HW Rev Voltage (V) Current (A) Power (W) Status LED
PSU 1 FSF045-611 FSF0451912000505 N/A 12.06 5.50 66.00 OK green
PSU 2 FSF045-611 FSF0451912000568 N/A 12.00 5.50 66.00 OK green
root@as7326-56x-3:/home/admin# sensors
lm75-i2c-15-4a
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +35.5 C (high = +80.0 C, hyst = +75.0 C)
lm75-i2c-15-4b
Adapter: i2c-1-mux (chan_id 6)
CPU Board Temperature: +29.0 C (high = +80.0 C, hyst = +75.0 C)
fan_ctrl-i2c-11-66
Adapter: i2c-1-mux (chan_id 2)
fan1: 9100 RPM
fan2: 9400 RPM
fan3: 9300 RPM
fan4: 9600 RPM
fan5: 9000 RPM
fan6: 9100 RPM
fan7: 9100 RPM
fan8: 9300 RPM
fan9: 9200 RPM
fan10: 9400 RPM
fan11: 9200 RPM
fan12: 9400 RPM
pch_haswell-virtual-0
Adapter: Virtual device
temp1: +43.0 C
psu_pmbus-i2c-17-59
Adapter: i2c-1-mux (chan_id 0)
in3: +12.06 V
fan1: 6272 RPM
temp1: +37.0 C
power2: 60.00 W
curr2: +6.00 A
lm75-i2c-15-49
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +40.0 C (high = +80.0 C, hyst = +75.0 C)
lm75-i2c-15-48
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +39.0 C (high = +80.0 C, hyst = +75.0 C)
psu_pmbus-i2c-13-5b
Adapter: i2c-1-mux (chan_id 4)
in3: +12.00 V
fan1: 6144 RPM
temp1: +36.0 C
power2: 66.00 W
curr2: +5.50 A
coretemp-isa-0000
Adapter: ISA adapter
Package id 0: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 0: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 1: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 2: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 3: +50.0 C (high = +82.0 C, crit = +104.0 C)
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
Why I did it
Added platform.json file for N3248TE
How I did it
Defined the platform.json file with the required components under chassis.
How to verify it
validated the API 2.0 test suite
Co-authored-by: Arun LK <Arun_L_K@dell.com>
DellEMC: N3248TE platform API2.0 changes
Why I did it
N3248TE Platform API 2.0 changes
How I did it
Implemented the functional API's needed for Platform API 2.0
Added system_health_monitoring_config.json file
How to verify it
Used the API 2.0 test suite to validate the test cases.
Co-authored-by: Arun LK <Arun_L_K@dell.com>
When do "skip_thermalcltd: true" will let "show platform fan" and "show platform temp" fail.
When enable thermalctld, these cmd will work well.
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
- Why I did it
Update NVIDIA Copyright header to "mellanox" files which were changed since 1.1.2022
- How I did it
Update the copyright header
- How to verify it
Sanity tests and PR checkers.
The following changes are provided to support bullseye and the latest master
branch content.
- Accommodate relocated fan and thermal sysfs entries in bullseye
- Add support for chassis and PSU HW revision
Why I did it
Fix platform issues introduced by the bullseye kernel upgrade.
How I did it
Minor fixes to Nokia ixs7215 platform code
How to verify it
Execute the following CLI commands
show platform summary
show platform fan
show platform temperature
Why I did it
The current code assumes that the value part does not have whitespace. So everything after the whitespace will be ignored. The syseeprom values returned from platform API do not match the output of "show platform syseeprom" on dx010 and e1031 device.
How I did it
This change improved the regular expression for parsing syseeprom values to accommodate whitespaces in the value.
PR 10021 provides the solution, but committed to the wrong place for dx010 and e1031.
How to verify it
Compile the sonic_platform wheel for dx010, then upload to device and install the wheel, verify the platform eeprom API.
Signed-off-by: Eric Zhu <erzhu@celestica.com>
Update device-specific files for new platform SN2201, including:
device/mellanox/x86_64-nvidia_sn2201-r0/ACS-SN2201/buffers_defaults_objects.j2
device/mellanox/x86_64-nvidia_sn2201-r0/ACS-SN2201/hwsku.json
device/mellanox/x86_64-nvidia_sn2201-r0/default_sku
device/mellanox/x86_64-nvidia_sn2201-r0/pcie.yaml
device/mellanox/x86_64-nvidia_sn2201-r0/platform.json
device/mellanox/x86_64-nvidia_sn2201-r0/platform_components.json
device/mellanox/x86_64-nvidia_sn2201-r0/sensors.conf
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
* Initial pass of EdgeCore platform changes.
* Remove libevent dependency from lldpd.
* Remove python2 dependencies python3.7 force from platform install script.
* Include usbmount support changes.
* Add missing 4630 install file.
* Update a few file permissions. Add umask line to Makefile. Specify python3.9 in install script.
* Misc platform updates:
- Add missing fan drawer component to sonic_platform
- Remove kernel version specification from Makefile
- Update to 4630 utility
* - Fix file permissions on source files
- Fix compile issue with 4630 driver modules (set_fs, get_fs, no longer supported in kernel 5.10)
* Fix missing/extra parens in 4630 util script.
* Fix indentation in fanutil.py.
* Integrate deltas from Edgecore to ec_platform branch.
* Installer update from Edgecore to resolve smbus serial console errors.
* Update stable_size for warm boot.
* Fix SFP dictionary key to match xcvrd.
* - Add missing define in event.py files needed for xcvrd
- Fix SFP info dict key for 7xxx switches
* 5835 platform file updates including installer and 5835 utility.
* 5835 fix for DMAR errors on serial console.
* Don't skip starting thermalctld in the pmon container.
* Revert several changes that were not related to platform.
* Run thermalctld in pmon container.
* Don't disable thermalctld in the pmon container.
* Fix prints/parens in 7816 install utility.
* - Incorporate 7816 changes from Edgecore
- Fix 7326 driver file using old kernel function
* Update kernel modules to use kernel_read().
* Fix compile errors with 7816 and 7326 driver modules.
* Fix some indents preventing platform files from loading.
* Update 7816 platform sfp dictionary to match field names in xcvrd.
* Add missing service and util files for 7816.
* Update file names, etc. based on full SKU for 7816.
* Delete pddf files not needed. These were causing conflicts with API2.0
implementation.
* Remove pddf files suggested by Edgecore that were preventing API2.0 support from starting.
* Install API2.0 file instead of pddf.
* Update 7326 mac service file to not use pddf. Fix syntax errors in 7326 utility script.
* Fix sonic_platform setup file for 7326.
* Fix syntax errors in python scripts.
* Updates to 7326 platform files.
* Fix some tab errors pulled down from master merge.
* Remove pddf files that were added from previous merge.
* Updates for 5835.
* Fix missing command byte for 5835 psu status.
* Fix permission bits on 4630 service files.
* Update platforms to use new SFP refactoring.
* Fix unused var warnings.
* [BFN] Implementation API for platform component
SONiC has a concept of "platform components"
this may include - CPLD, FPGA, BIOS, BMC, etc.
These changes are needed to read the version of the BIOS and BMC component.
What I did
Create components.py module
Add funcion for reading componet version to thrift interface
How I did it
The previous implementaion didn't have platform components API, so fwutil return an empty list.
After implementation of the platform component API, we have actual list of platform components and firmware versions
How to verify it
Run manually 'fwutil show status' or run unit tests
Previous command output
Chassis Module Component Version Description
------------------------ -------- ----------- --------- -------------
New command output
Chassis Module Component Version Description
------------------------ -------- ----------- --------- -------------
Chassis1 N/A BIOS 1.2.3 Chassis BIOS
BMC 5.1 Chassis BMC
Signed-off-by: Taras Keryk <tarasx.keryk@intel.com>
* [BFN] Implementation API for platform component
SONiC has a concept of "platform components"
this may include - CPLD, FPGA, BIOS, BMC, etc.
These changes are needed to read the version of the BIOS and BMC component.
What I did
Create components.py module
Add funcion for reading componet version to thrift interface
How I did it
The previous implementaion didn't have platform components API, so fwutil return an empty list.
After implementation of the platform component API, we have actual list of platform components and firmware versions
How to verify it
Run manually 'fwutil show status' or run unit tests
Previous command output
Chassis Module Component Version Description
------------------------ -------- ----------- --------- -------------
New command output
Chassis Module Component Version Description
------------------------ -------- ----------- --------- -------------
Chassis1 N/A BIOS 1.2.3 Chassis BIOS
BMC 5.1 Chassis BMC
Signed-off-by: Taras Keryk <tarasx.keryk@intel.com>
* [BFN] Implementation API for platform component
get chassis name from json
* [BFN] Implementation API for platform component
Updated platform and platrom_components json
* [BFN] Implementation API for platform component
Fixed spaces in component.py
* [BFN] Implementation API for platform component
Fixed exception in component.py
* Update chassis.py
* [BFN] Implementation API for platform component
Fixed spaces in component.py, chassis.py
* [BFN] Implementation API for platform component: Fixed spaces in component.py, chassis.py
* Fixed exception in get_bios_version
Signed-off-by: Jostar Yang jostar_yang@accton.com.tw
Why I did it
Fix led drv because CPLD SPEC is updated.
Fix i2c bus order
How I did it
Fix led drv. Set blacklist to i801 and ismt. Let accton util to modprobe i801 and ismt.
How to verify it
Test led and sensors cmd. Results are fine.
Why I did it
To fix I2C bus order to meet with HW SPEC. Let i801 use bus-0 and ismt use bus-1
How I did it
Modprobe i801 and then do ismt. So i801 will use bus-0 and ismt will use bus-1.
How to verify it
Test show cmd and sensors work well
Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
Signed-off-by: Jostar Yang jostar_yang@accton.com.tw
Why I did it
Linux kernel 5.10, 'force_deselct_on_exit' parameter used for driver i2c_mux_pca954x is no longer valid. Instead an attribute 'idle_state' is added per MUX device. So set idle_state=-2 will let do deselect to pca954 when device channel exit . To avoid cause another device channel access i2c fail.
How I did it
Remove force_deselect_on_exit because not use this parameter.
Add "idle_state":"-2" to each "virt_bus"
How to verify it
Test all sysfs are fine.
* Add support for Accton wedge100bf_32qs platform
This pull request is based on wedge100bf_32x.
The components on the mainboard are the same as wedge100bf_32x, except for tofino 32Q and COMe models, so it refers to wedge100bf_32x to create new model: wedge100bf_32qs.
Signed-off-by: alvin_feng <alvin_feng@accton.com>
* Fix lgtm alerts issues
Signed-off-by: alvin_feng <alvin_feng@accton.com>
* Modify some file permissions and use symlink to link wedge100bf-32qs/sonic_platform
Signed-off-by: alvin_feng <alvin_feng@accton.com>
* Remove switch-sai.conf file
Signed-off-by: alvin_feng <alvin_feng@accton.com>
* Modify platform.json to avoid platform TCs issues and changes for correct generating BUFFER_QUEUE values in DB.
Signed-off-by: alvin_feng <alvin_feng@accton.com>
* Fix error name in platform.json
* Fix KeyError exception while sfputil show eeprom.
* Implement reset/lpmode related APIs, which need PR8115's sysfs.
* Fix EEPROM byte offset in several APIs
* Fix typos
* Implement get_position_in_parent() and is_replaceable()
Signed-off-by: Sean Wu <sean_wu@edge-core.com>
- Why I did it
The chassis name in MSN4410 platform_components.json is not correct
- How I did it
Fix the chassis name
- How to verify it
Run relevant platform API test
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Need to remove old static configs from sai.profile files.
New implementation: Azure/sonic-swss#1959
New configuration: #9658
- How I did it
Remove SAI_VXLAN_SRCPORT_RANGE_ENABLE=1 lines from files per HWSKU
- How to verify it
When static config is removed following test will fail (src port will be in range 0-255)
py.test vxlan/test_vnet_vxlan.py --inventory "../ansible/inventory, ../ansible/veos" --host-pattern (testbed)-t0 --module-path ../ansible/library/ --testbed (testbed)-t0 --testbed_file ../ansible/testbed.csv --allow_recover --assert plain --log-cli-level info --show-capture=no -ra --showlocals --disable_loganalyzer --skip_sanity --upper_bound_udp_port 65535 --lower_bound_udp_port 64128
* [AS4630-54PE] Add to support PDDF
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
* Fix LGTM alerts
* Fix LGTM alerts
* Fix LGTM alerts
* Add post_device.sh to turn off stk led
* Add to support system_health
* Correct the wait and timeout mechanism for better CPU usage
* Add event.c to support port evt change
Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
- Why I did it
platform.json of 4600C only has 2 CPU core thermal sensors, but there are 4 actually
- How I did it
Added thermal sensors for CPU core 2 and core 3.
- How to verify it
Build.
- Why I did it
There was a missing file of platform.json on SN4800 SIMx platform
- How I did it
Add symbolic link to platform.json file from the real SN4800 platform
- How to verify it
Run SN4800 SIMx and verify that platfrom.json file exist at the following folder:
/usr/share/sonic/device/x86_64-nvidia_sn4800_simx-r0
Added midplane_subnet in chassisdb.conf for interfaces-config.sh to create midplane interface in multi-asic namespaces.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
* [AS7726-32X] Add to support mulit PSU in PDDF
Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
* Modify SN offset and include path
* Fix device_name to PSU2-EEPROM in PSU2
Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
Why I did it
Updated the BCM config recommended by Broadcom for Nokia-IXR7250E-36x400G
How I did it
Updated the BCM config file
How to verify it
Verified running the image with this BCM config in Nokia-IXR7250E-36x400G and ensured that the syncd container was stable, ports were up and passing the traffic.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
- Why I did it
Remove obsolete parameter that enables static VXLAN src port range
provide functionality no generate json config file according to appropriate parameter in config_db
Done for
SN3800:
• Mellanox-SN3800-D28C50
• Mellanox-SN3800-C64
• Mellanox-SN3800-D28C49S1 (New 10G SKU)
SN2700:
• Mellanox-SN2700-D48C8
- How I did it
Remove SAI_VXLAN_SRCPORT_RANGE_ENABLE=1 from appropriate sai.profile files
Created vxlan.json file and added few params that depends on DEVICE_METADATA.localhost.vxlan_port_range
- How to verify it
File /etc/swss/config.d/vxlan.json should be generated inside swss docker when it restart
[
{
"SWITCH_TABLE:switch": {
"vxlan_src": "0xFF00",
"vxlan_mask": "8"
},
"OP": "SET"
}
]
Signed-off-by: Andriy Yurkiv <ayurkiv@nvidia.com>
* [y_cable] Support for initialization of new Daemon ycable to support
ycables
This PR also adds the commit in sonic-platform-daemons
94fa239 [y_cable] refactor y_cable to a seperate logic and new daemon from xcvrd (#219)
Why I did it
This PR separates the logic of Y-Cable from xcvrd. Before this change we were utilizing xcvrd daemon to control all aspects of Y-Cable right from initialization to processing requests from other entities like orch,linkmgr.
Now we would have another daemon ycabled which will serve this purpose.
Logically everything still remains the same from the perspective of other daemons.
it also take care aspects like init/delete daemon from Y-Cable perspective.
How I did it
To serve the purpose we build a new wheel sonic_ycabled-1.0-py3-none-any.whl and install it inside pmon.
We also initalize the daemon ycabled which serves our purpose for refactor inside pmon
How to verify it
Ran the changes with an image for dualtor tests on a 7050cx3 platform
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
Why I did it
Requirements from Microsoft for fwutil update all state that all firmwares which support this upgrade flow must support upgrade within a single boot cycle. This conflicted with a number of Mellanox upgrade flows which have been revised to safely meet this requirement.
How I did it
Added --no-power-cycle flags to SSD and ONIE firmware scripts
Modified Platform API to call firmware upgrade flows with this new flag during fwutil update all
Added a script to our reboot plugin to handle installing firmwares in the correct order with prior to reboot
How to verify it
Populate platform_components.json with firmware for CPLD / BIOS / ONIE / SSD
Execute fwutil update all fw --boot cold
CPLD will burn / ONIE and BIOS images will stage / SSD will schedule for reboot
Reboot the switch
SSD will install / CPLD will refresh / switch will power cycle into ONIE
ONIE installer will upgrade ONIE and BIOS / switch will reboot back into SONiC
In SONiC run fwutil show status to check that all firmware upgrades were successful
Tested on a Celestica Seastone2 DX030 switch
Testing scenarios:
- Various QSFP ports in both normal and breakout config.
- 100G and 40G link speed show different colors.
- SFP1 port works.
Signed-off-by: Christian Svensson <blue@cmd.nu>
- Why I did it
For MSN4410/MSN4600/MSN4700 now they can support fetching PSU voltage threshold, no need to skip the psu voltage check in system health monitoring, so update the system health monitoring configuration file for these platforms.
- How I did it
remove skip PSU change config from the system_health_monitoring_config.json file
- How to verify it
Build image run on these platforms, system health monitoring will not report error against PSU voltage
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
MSN4700 platform has 8 lanes per port and thus can support 2x40G with each lane running at 10G
- How I did it
Added 40G to 2x200G breakout mode in platform.json
- How to verify it
Run config int break Ethernet0 2x40G[200G,100G,50G,25G,10G,1G]
And verify the command runs successfully and the port speed was set to 40G with a 2x breakout.