* Add support for vlanconfd and intfconfd
Signed-off-by: Jipan Yang <jipan.yang@alibaba-inc.com>
* Change name to vlanmgrd and intfmgrd
Signed-off-by: Jipan Yang <jipan.yang@alibaba-inc.com>
* Add missing vlan_members for parse_dpg result
Signed-off-by: Jipan Yang <jipan.yang@alibaba-inc.com>
* Remove cfgmgr debug CLI from image
Signed-off-by: Jipan Yang <jipan.yang@alibaba-inc.com>
* Update swss and swss-common submodules for VLAN trunk support
Signed-off-by: Jipan Yang <jipan.yang@alibaba-inc.com>
Modify minigraph parser output format so it fit DB schema
Modify configuration templates to fit new schema
Systemd services dependencies are modified so database starts before any configuration consumer
If routes are inserted in main table, they wont' be overwritten
by the routes learned via BGP. Then the routes will be missing
from the ASIC.
Thus a default table is used so that control plane and data plane
routes are isolated and could be configured independently.
- Do not bring up LAG member ports when LAG is not created.
This is because LAG member ports must be DOWN when joining
the teamd instances due to teamd design. Therefore, we cannot
bring up a LAG member port first and then join the port to a LAG.
Signed-off-by: Shuotian Cheng <shuche@microsoft.com>
- This change is added so that when doing ifdown/ifup to flap the
interface, it will success even when the interface is already
enslaved as a member of VLAN.
- LAG members do not have IP addresses. Thus ifconfig command is
needed.
- Do not display comments when not necessary.
Signed-off-by: Shuotian Cheng <shuche@microsoft.com>
The reason is that /etc/network/interfaces file is in base image. After booting,
docker-swss is not ready and thus the empty VLAN interfaces cannot be created
when the brctl is pointing to the binary inside the swss docker.
Add the bridge-utils into the base image and add bridge_ports none to the
/etc/network/interfaces file so that after boot-up the empty VLAN interfaces
will be created to let the members to join later.
Signed-off-by: Shuotian Cheng <shuche@microsoft.com>
* [files]: Add allow-hotplug stanza to interfaces files
- start interface <interface_name> when the kernel detects
a hotplug event from the interface
ref: https://www.debian.org/doc/manuals/debian-reference/ch05.en.html
* [interfaces]: Combine vlan_interfaces and lag_interfaces file and add allow-hotplug
1. Remove vlan_interfaces and lag_interfaces file and members in teamd.j2
2. Add all interfaces to /etc/network/interfaces file
3. Add allow-hotplug stanza
4. Add up <command> to automatically add interfaces to VLAN and LAG
5. Add unique_name filter to minigraph.py to remove duplicate interface names
6. Add brctl to base image
7. Update sonic-swss submodule
Signed-off-by: Shuotian Cheng <shuche@microsoft.com>
* Single image
* Fix review comments
* Update syncd service. Add HW mgmt to Mellanox single image.
* Add single image template for Broadcom platform.
SKU should be provided during configure:
make configure PLATFORM=broadcom SKU=Force10-S6000
* Add single image template for Cavium platform.
SKU should be provided during configure:
make configure PLATFORM=cavium SKU=AS7512
* Add description to sonic_debian_extension.j2 file.