Commit Graph

7 Commits

Author SHA1 Message Date
abdosi
62968eca6d Update bcm soc property bcm_num_cos from 8 to 10 (#5314)
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2020-09-04 21:13:16 +00:00
Roy Lee
efe9438c61 [Accton] Correct port index and offer the default speed. (#3213)
* [as5712-54x]
Verified with index from 1.
Add qsfp_event() for command "show interaface trancerver".
Signed-off-by: roy_lee <roy_lee@accton.com>

* [as6712-32x]
Add default port speed.
Verified with index from 1.

Signed-off-by: roy_lee <roy_lee@accton.com>

* [as7726-32x]
Add default port speed.
Verified with index from 1.
Signed-off-by: roy_lee <roy_lee@accton.com>

* [as7712-32x]
Add default port speed.
Verified with index from 1.
Signed-off-by: roy_lee <roy_lee@accton.com>

* [as5812-54x]
Add default port speed.
Verified with index from 1.

Signed-off-by: roy_lee <roy_lee@accton.com>

* [as5712-54x]
Update port-config with 1-based index.
Signed-off-by: roy_lee <roy_lee@accton.com>

* [as5812-54x]
Somehow the service may block, use type=simple to work-around.
Add syslog function for monitor.
Signed-off-by: roy_lee <roy_lee@accton.com>

* [as7716-32x]
Update port-config with 1-based index.
Signed-off-by: roy_lee <roy_lee@accton.com>

* [as7816-64x]
Update port-config with 1-based index.
Implement sfputil change_event.
Signed-off-by: roy_lee <roy_lee@accton.com>

* [as7326-56x]
Update port-config with 1-based index.
Implement sfputil change_event.

Signed-off-by: roy_lee <roy_lee@accton.com>

* Remove debug code.
Signed-off-by: roy_lee <roy_lee@accton.com>

* [as7312-54x]
Update port-config with 1-based index and default port speed.

Signed-off-by: roy_lee <roy_lee@accton.com>
2019-07-24 12:14:43 -07:00
KIRAN KUMAR KELLA
e6251bd9d5 [devices]: ALPM is not working on AS5712/TD2 platforms. (#2469)
- Also initialized the number of cos queues in AS5712 to 8.
    Else the interfaces are not coming up due to a lower default value of cos queues in AS5712.

  Fix:
    - Enable alpm settings in the platform config file for AS5712.
    - With the current values of l2_mem_entries (163840) and l3_mem_entries (81920), the memory is not sufficient. Scale them down to the
      values that work for ALPM in as5712 [l2_mem_entries = 32768, l3_mem_entries = 16384].

  Signed-off-by: kiran.kella@broadcom.com
2019-01-23 01:14:47 -08:00
Ying Xie
5ab66b191a
[bcm config] remove scache_filename config entry (#2140)
Warm boot is managed by SAI. This configuration entry shouldn't be
included in bcm config.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2018-10-12 08:05:38 -07:00
Ying Xie
e7ef637a09
[config-bcm] move broadcom config files to device folder (#1947)
- Future versions of SAI packages will stop carrying these files.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2018-08-20 10:11:11 -07:00
Polly Hsu
0f903d008b [Accton]: Add a new supported platform, AS5712-54X (#1167)
* Switch Vendor: Edge-core
* Switch SKU: AS5712-54X
* ASIC Vendor: Broadcom
* Swich ASIC: TRIDENT2
* Port Configuration: 48x10G+6x40G
* SONiC Image: SONiC-ONIE-Broadcom

Signed-off-by: polly_hsu@accton.com
2017-11-22 02:59:28 -08:00
jeankuo
12ba083b66 [Accton]: Add a new supported device AS5712-54X (#898)
* [Accton]: Add a new supported device AS5712-54X
Switch Vendor: Edge-core
Switch SKU: AS5712-54X
ASIC Vendor: Broadcom
Swich ASIC: TRIDENT2
Port Configuration: 48x10G+6x40G
SONiC Image: SONiC-ONIE-Broadcom

* [Accton]: Add a new supported device AS5712-54X (Update 1)
Switch Vendor: Edge-core
Switch SKU: AS5712-54X
ASIC Vendor: Broadcom
Swich ASIC: TRIDENT2
Port Configuration: 48x10G+6x40G
SONiC Image: SONiC-ONIE-Broadcom

* [Accton]: Add a new supported device AS5712-54X (Update 2)
Switch Vendor: Edge-core
Switch SKU: AS5712-54X
ASIC Vendor: Broadcom
Swich ASIC: TRIDENT2
Port Configuration: 48x10G+6x40G
SONiC Image: SONiC-ONIE-Broadcom

* [Accton]: Add a new supported device AS5712-54X (Update 3)
Switch Vendor: Edge-core
Switch SKU: AS5712-54X
ASIC Vendor: Broadcom
Swich ASIC: TRIDENT2
Port Configuration: 48x10G+6x40G
SONiC Image: SONiC-ONIE-Broadcom
2017-08-23 12:08:43 -07:00