**- Why I did it**
Initially, the critical_processes file contains either the name of critical process or the name of group.
For example, the critical_processes file in the dhcp_relay container contains a single group name
`isc-dhcp-relay`. When testing the autorestart feature of each container, we need get all the critical
processes and test whether a container can be restarted correctly if one of its critical processes is
killed. However, it will be difficult to differentiate whether the names in the critical_processes file are
the critical processes or group names. At the same time, changing the syntax in this file will separate the individual process from the groups and also makes it clear to the user.
Right now the critical_processes file contains two different kind of entries. One is "program:xxx" which indicates a critical process. Another is "group:xxx" which indicates a group of critical processes
managed by supervisord using the name "xxx". At the same time, I also updated the logic to
parse the file critical_processes in supervisor-proc-event-listener script.
**- How to verify it**
We can first enable the autorestart feature of a specified container for example `dhcp_relay` by running the comman `sudo config container feature autorestart dhcp_relay enabled` on DUT. Then we can select a critical process from the command `docker top dhcp_relay` and use the command `sudo kill -SIGKILL <pid>` to kill that critical process. Final step is to check whether the container is restarted correctly or not.
**- Why I did it**
After discussed with Joe, we use the string "/usr/bin/syncd\s" in Monit configuration file to monitor
syncd process on Broadcom and Mellanox. Due to my careless, I did not find this bug during the
previous testing. If we use the string "/usr/bin/syncd" in Monit configuration file to monitor the
syncd process, Monit will not detect whether syncd process is running or not.
If we ran the command `sudo monit procmactch “/usr/bin/syncd”` on Broadcom, there will be three
processes in syncd container which matched this "/usr/bin/syncd": `/bin/bash /usr/bin/syncd.sh
wait`, `/usr/bin/dsserve /usr/bin/syncd –diag -u -p /etc/sai.d/sai.profile` and `/usr/bin/syncd –diag -
u -p /etc/sai.d/said.profile`. Monit will select the processes with the highest uptime (at there
`/bin/bash /usr/bin/syncd.sh wait`) to match and did not select `/usr/bin/syncd –diag -u -p
/etc/sai.d/said.profile` to match.
Similarly, On Mellanox Monit will also select the process with the highest uptime (at there
`/bin/bash /usr/bin/syncd.sh wait`) to match and did not select `/usr/bin/syncd –diag -u -p
/etc/sai.d/said.profile` to match.
That is why Monit is unable to detect whether syncd process is running or not if we use the string “/usr/bin/syncd” in Monit configuration file. If we use the string "/usr/bin/syncd\s" in Monit configuration file, Monit can filter out the process `/bin/bash /usr/bin/syncd.sh wait` and thus can correctly monitor the syncd process.
**- How I did it**
**- How to verify it**
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* Change port index in port_config.ini to 1-based
* Add default port index to port_config.ini, change platform plugins to accept 1-based port index
* fix port index in sfp_event.py
**- Why I did it**
The tx_disable function isn't work for the accton_ax5835-54x device.
**- How I did it**
Fix the incorrect path of the sfp node path inside the util file.
**- How to verify it**
Test with
"sudo accton_as5835_54x_util.py show"
"sudo accton_as5835_54x_util.py set sfp"
There should see correct value for module_present and module_tx_disable. And should able to set it.
Signed-off-by: kuanyu_chen <kuanyu_chen@edge-core.com>
The `-sv2` suffix was used to differentiate SNMP Dockers when we transitioned from "SONiCv1" to "SONiCv2", about four years ago. The old Docker materials were removed long ago; there is no need to keep this suffix. Removing it aligns the name with all the other Dockers.
Also edit Monit configuration to detect proper snmp-subagent command line in Buster, and make snmpd command line matching more robust.
- Add .gitignore files in each subdirectory of src/, so as to reduce the size of the .gitignore file in the project root, and also make it easier to maintain (i.e., if a directory in src/ is removed, there will not be outdated entries in the root .gitignore file.
- Also add missing .gitignore entries and remove outdated entries and duplicates.
The -sv2 suffix was used to differentiate SNMP Dockers when we transitioned from "SONiCv1" to "SONiCv2", about four years ago. The old Docker materials were removed long ago; there is no need to keep this suffix. Removing it aligns the name with all the other Dockers.
**- Why I did it**
For decoding system EEPROM of S6000 based on Dell offset format and S6000-ON’s system EEPROM in ONIE TLV format.
**- How I did it**
- Differentiate between S6000 and S6000-ON using the product name available in ‘dmi’ ( “/sys/class/dmi/id/product_name” )
- For decoding S6000 system EEPROM in Dell offset format and updating the redis DB with the EEPROM contents, added a new class ‘EepromS6000’ in eeprom.py,
- Renamed certain methods in both Eeprom, EepromS6000 classes to accommodate the plugin-specific methods.
**- How to verify it**
- Use 'decode-syseeprom' command to list the system EEPROM details.
- Wrote a python script to load chassis class and call the appropriate methods.
UT Logs: [S6000_eeprom_logs.txt](https://github.com/Azure/sonic-buildimage/files/4735515/S6000_eeprom_logs.txt), [S6000-ON_eeprom_logs.txt](https://github.com/Azure/sonic-buildimage/files/4735461/S6000-ON_eeprom_logs.txt)
Test script: [eeprom_test_py.txt](https://github.com/Azure/sonic-buildimage/files/4735509/eeprom_test_py.txt)
- Sensor and Fan information added to primary platforms for thermal API.
- Refactors involving better abstractions, code reuse and dead code removal.
- Improvements to the diag capabilities
- Pylintrc added to improve code quality. Will become fatal at a later time.
Co-authored-by: Baptiste Covolato <baptiste@arista.com>
Cleanup description string
First port (management port) are excluded from general port naming scheme.
Management port are excluded from general port naming scheme.
before:
|on GNS3 |in SONiC |
|---------|---------|
|Ethernet0|eth0 |
|Ethernet1|Ethernet0|
|Ethernet2|Ethernet4|
|Ethernet3|Ethernet8|
after:
|on GNS3 |in SONiC |
|---------|---------|
|eth0 |eth0 |
|Ethernet0|Ethernet0|
|Ethernet1|Ethernet4|
|Ethernet2|Ethernet8|
Signed-off-by: Masaru OKI <masaru.oki@gmail.com>
* Update sonic-sairedis (sairedis with SAI 1.6 headers)
* Update SAIBCM to 3.7.4.2, which is built upon SAI1.6 headers
* missed updating BRCM_SAI variable, fixed it
* Update SAIBCM to 3.7.4.2, updated link to libsaibcm
* [Mellanox] Update SAI (release:v1.16.3; API:v1.6)
Signed-off-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
* Update sonic-sairedis pointer to include SAI1.6 headers
* [Mellanox] Update SDK to 4.4.0914 and FW to xx.2007.1112 to match SAI 1.16.3 (API:v1.6)
Signed-off-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
* ensure the veth link is up in docker VS container
* ensure the veth link is up in docker VS container
* [Mellanox] Update SAI (release:v1.16.3.2; API:v1.6)
Signed-off-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
* use 'config interface startup' instead of using ifconfig command, also undid the previous change'
Co-authored-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
- Skip thermalctld in DellEMC S6000, S6100, Z9100 and Z9264 platforms.
- Change the return type of thermal Platform APIs in DellEMC S6000, S6100, Z9100 and Z9264 platforms to 'float'.
* [platform]: Add a new supported platform, Delta-agc032
Switch Vendor: Delta
Switch SKU: Delta-agc032
CPU: BROADWELL-DE
ASIC Vendor: Broadcom
Switch ASIC: Tomahawk3, BCM56980
Port Configuration: 32x400G + 2x10G
- What I did
Add a new Delta platform Delta-agc032.
- How I did it
Add files by following SONiC Porting Guide.
- How to verify it
1. decode-syseeprom
2. sensors
3. psuutil
4. sfputil
5. show interface status
6. bcmcmd
Signed-off-by: zoe-kuan <ZOE.KUAN@deltaww.com>
3y Power YPEB-1200am PSU doens't support read fan_dir from pmbus register
Check with vendor this PUS type only support F2B fan direction. So add to show "F2B"
when red psu_fan_dir sysfs.
* Trigger thermal action log only if thermal condition changes
* test file existence before read file content
* fix error for set psu fan speed
* Remove logs because it print too frequently
- bug fix : Fixed an issue which the nps ko file was not loaded due to the wrong service file name
- Optimize the code to reduce changes due to the kernel upgrade
- Remove nephos ko file loaded in swss.service.j2 because it has loaded at syncd.service.j2
For detecting transceiver change events through xcvrd in DellEMC S6000, S6100 and Z9100 platforms.
- In S6000, rename 'get_transceiver_change_event' in chassis.py to 'get_change_event' and return appropriate values.
- In S6100, implement 'get_change_event' through polling method (poll interval = 1 second) in chassis.py (Transceiver insertion/removal does not generate interrupts due to a CPLD bug)
- In Z9100, implement 'get_change_event' through interrupt method using select.epoll().