- Why I did it
interfaces-config service restarts networking service, during the restart loopback interface address is being removed and reassigned back, leaving loopback without an ipv4 address for a while.
On SONiC startup and config reload interfaces-config and bgp services start in parallel and sometimes
fpmsyncd in bgp attempts bind to loopback while it does not have an address, fails with the log
Exception "Cannot assign requested address" had been thrown in daemon
and exits with rc 0.
root@sonic:/# supervisorctl status
fpmsyncd EXITED Jul 20 05:04 AM
zebra RUNNING pid 35, uptime 6:15:05
zsocket EXITED Jul 20 05:04 AM
docker logs bgp
INFO exited: fpmsyncd (exit status 0; expected)
With fpmsyncd dead, configured routes do not appear in the database.
- How I did it
Added ordering dependency on interfaces-config service into bgp.config
- How to verify it
Itself the issue reproduces quite rarely, but one can gain the time interval between networking down and networking up in interfaces-config.sh like this:
diff --git a/files/image_config/interfaces/interfaces-config.sh b/files/image_config/interfaces/interfaces-config.sh
index f6aa4147a..87caceeff 100755
--- a/files/image_config/interfaces/interfaces-config.sh
+++ b/files/image_config/interfaces/interfaces-config.sh
@@ -63,7 +63,11 @@ done
# Read sysctl conf files again
sysctl -p /etc/sysctl.d/90-dhcp6-systcl.conf
-systemctl restart networking
+# systemctl restart networking
+
+systemctl start networking
+sleep 10
+systemctl stop networking
# Clean-up created files
rm -f /tmp/ztp_input.json /tmp/ztp_port_data.json
with this change the issue reproduces on every config reload.
Signed-off-by: Volodymyr Boyko <volodymyrx.boiko@intel.com>
Multi-asic Docker instances are created behind Docker's default bridge
which doesn't allow talking to other Docker instances that are in the
host network (like database-chassis).
On linecards, we configure midplane interfaces to let per-asic docker
containers talk to CHASSIS_DB on the supervisor through internal chassis
network.
On the supervisor we don't need to use chassis internal network, but we
still need a similar setup in order to allow fabric containers to talk
to database-chassis
Manually cherry-picking #11893
- Why I did it
The timer execution may fail if triggered during a config reload (when the sonic.target is stopped). This might happen in a rare situation if config reload is executed after reboot in a small time slot (for 0 to 30 seconds) before the tacacs-config timer is triggered:
systemctl status tacacs-config.timer
tacacs-config.timer - Delays tacacs apply until SONiC has started
Loaded: loaded (/lib/systemd/system/tacacs-config.timer; enabled-runtime; vendor preset: enabled)
Active: failed (Result: resources) since Mon 2022-08-29 15:53:03 IDT; 1min 28s ago
Trigger: n/a
Triggers: tacacs-config.service
Aug 29 15:47:53 r-boxer-sw01 systemd[1]: Started Delays tacacs apply until SONiC has started.
Aug 29 15:53:03 r-boxer-sw01 systemd[1]: tacacs-config.timer: Failed to queue unit startup job: Transaction for tacacs-config.service/start is destructive (mgmt-framework.timer has 's>
Aug 29 15:53:03 r-boxer-sw01 systemd[1]: tacacs-config.timer: Failed with result 'resources'.
- How I did it
To ensure that timer execution will be resumed after a config reload the WantedBy section of the systemd service is updated to describe relation to sonic.target.
- How to verify it
Reboot the system
After reboot monitor tacacs-config.timer status. 30 seconds before timer activation run "config reload -y" command.
Check system status.
Signed-off-by: Oleksandr Ivantsiv <oivantsiv@nvidia.com>
* Pin version of bazelisk to v1.13.0
This tries to avoid builds failures due to the latest version of
bazelisk changing and causing hash mismatches.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
bazelisk package with hash value 1227b24db77557d552701f6add122edc is deleted from github release.
Reproducible build only cached hash value. Package file didn't be cached. Because they are in different pipelines.
Using latest package hash instead.
Why I did it
If the SWSS services was restarted, the MACsec service should also be restarted. Otherwise the data in wpa_supplicant and orchagent will not be consistent.
How I did it
Add dependency in docker-macsec.mk.
How to verify it
Manually check by 'sudo service swss restart'.
The MACsec container should be started after swss, the syslog will look like
Sep 8 14:36:29.562953 sonic INFO swss.sh[9661]: Starting existing swss container with HWSKU Force10-S6000
Sep 8 14:36:30.024399 sonic DEBUG container: container_start: BEGIN
...
Sep 8 14:36:33.391706 sonic INFO systemd[1]: Starting macsec container...
Sep 8 14:36:33.392925 sonic INFO systemd[1]: Starting Management Framework container...
Signed-off-by: Ze Gan <ganze718@gmail.com>
* [mux] skip mux operations during warm shutdown
- Enhance write_standby.py script to skip actions during warm shutdown.
- Expand the support to BGP service.
- MuX support was added by a previous PR.
- don't skip action during warm recovery
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
After pinging any failed IPv6 neighbor entries, set the remaining failed/incomplete entries to a permanent INCOMPLETE state. This manual setting to INCOMPLETE prevents these entries from automatically transitioning to FAILED state, and since they are now incomplete any subsequent NA messages for these neighbors is able to resolve the entry in the cache.
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
It could happen that a container has already crashed but docker-wait-any
will wait forever till it starts. It should, however, immediately exit
to make the serivce restart.
#### Why I did it
It is observed in some circumstances that the auto-restart mechanism does not work. Specifically for ```swss.service```, ```orchagent``` had crashed before ```docker-wait-any``` started in ```swss.sh```. This led ```docker-wait-any``` wait forever for ```swss``` to be in ```"Running"``` state and it results in:
```
CONTAINER ID IMAGE COMMAND CREATED STATUS PORTS NAMES
1abef1ecebff bcbca2b74df6 "/usr/local/bin/supe…" 22 hours ago Up 22 hours what-just-happened
3c924d405cd5 docker-lldp:latest "/usr/bin/docker-lld…" 22 hours ago Up 22 hours lldp
eb2b12a98c13 docker-router-advertiser:latest "/usr/bin/docker-ini…" 22 hours ago Up 22 hours radv
d6aac4a46974 docker-sonic-mgmt-framework:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours mgmt-framework
d880fd07aab9 docker-platform-monitor:latest "/usr/bin/docker_ini…" 22 hours ago Up 22 hours pmon
75f9e22d4fdd docker-snmp:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours snmp
76d570a4bd1c docker-sonic-telemetry:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours telemetry
ee49f50344b3 docker-syncd-mlnx:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours syncd
1f0b0bab3687 docker-teamd:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours teamd
917aeeaf9722 docker-orchagent:latest "/usr/bin/docker-ini…" 22 hours ago Exited (0) 22 hours ago swss
81a4d3e820e8 docker-fpm-frr:latest "/usr/bin/docker_ini…" 22 hours ago Up 22 hours bgp
f6eee8be282c docker-database:latest "/usr/local/bin/dock…" 22 hours ago Up 22 hours database
```
The check for ```"Running"``` state is not needed because for cold boot case we do ```start_peer_and_dependent_services``` and for warm boot case the loop will retry to wait for container if this container is doing warm boot:
d01a91a569/files/image_config/misc/docker-wait-any (L56)
#### How I did it
Removed the check for ```"Running"```.
#### How to verify it
Kill swss before ```docker-wait-any``` is reached and verify auto restart will restart swss serivce.
As part of PR #11754
Change was added to use variable SONIC_DB_NS_CLI for
namespace but that will not work since ./files/scripts/syncd_common.sh
uses SONIC_DB_CLI. So revert back to use SONIC_DB_CLI and define new
variable for SONIC_GLOBAL_DB_CLI for global/host db cli access
Also fixed DB_CLI not working for namespace.
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.
How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51
Change `sxdkernel start` to `sxdkernel restart`. If `syncd` service crashes in `ExecStartPre` systemd will not call `ExecStop` and thus will not call `sxdkernel stop`. Use of `sxdkernel restart` is more robust in terms of guarantees to restore the system after unexpected crashes.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Why I did it
On a supervisor card in a chassis, syncd/teamd/swss/lldp etc dockers are created for each Switch Fabric card. However, not all chassis would have all the switch fabric cards present. In this case, only dockers for Switch Fabrics present would be created.
The monit 'container_checker' fails in this scenario as it is expecting dockers for all Switch Fabrics (based on NUM_ASIC defined in asic.conf file).
This was done manually, to try to get past a build error due to changing
package versions in Debian.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did:
In case of multi-asic platforms gbsyncd is not getting added to Feature Table of Host Config DB. Without this container_checker complains of not needed gbsyncd container's are running.
How I did:
Update Both Host and Namespace config db when gbsyncd docker is starting.
How I verify:
Verified on Multi-asic platforms.
bgp should be a per-asic service, and runs for each namespace on
multi-asic platforms. However, putting bgp in MULTI_INST_DEPENDENT
causes swss to be restarted as well as bgp. this is causing issues after #11000
Issue: #11653
This fix:
removes bgp from dependents list
adds a conditional that either adds bgp, or bgp@$DEV to separate
between single and multi-asic platforms
Cherry pick PR https://github.com/sonic-net/sonic-buildimage/pull/10825 to 202205 branch
#### Why I did it
Fix sonic-db-cli high CPU usage on SONiC startup issue: https://github.com/sonic-net/sonic-buildimage/issues/10218
ETA of this issue will be 2022/05/31
#### How I did it
Re-write sonic-cli with c++ in sonic-swss-common: https://github.com/sonic-net/sonic-swss-common/pull/607
Modify swss-common rules and slave.mk to install c++ version sonic-db-cli.
#### How to verify it
Pass all E2E test scenario.
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
#### Description for the changelog
Build and install c++ version sonic-db-cli from swss-common.
#### Link to config_db schema for YANG module changes
<!--
Provide a link to config_db schema for the table for which YANG model
is defined
Link should point to correct section on https://github.com/Azure/SONiC/wiki/Configuration.
-->
#### A picture of a cute animal (not mandatory but encouraged)
In arp_update, check for FAILED or INCOMPLETE kernel neighbor entries and manually ping them to try and resolve the neighbor
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
When using trap on SIGTERM the script will not react to the SIGTERM signal sent while a child is executing.
I.e, the following script does not react on SIGTERM sent to it if it is
waiting for sleep to finish:
```
trap "echo Handled SIGTERM" 0 2 3 15
echo "Before sleep"
sleep inf
echo "After sleep"
```
Instead, trap only on EXIT which covers also a scenario with exit on
SIGINT, SIGTERM.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Why I did it
The initial value has to be present for the state machines to work. In active-standby dual-tor scenario, or any hardware mux scenario, the value will be updtaed eventually with a delay.
However, in active-active dual-tor scenario, there is no other mechanism to initialize the value and get state machines started.
So this script will have to write something at start up time.
For active-active dualtor, 'active' is a more preferred initial value, the state machine will switch the state to standby soon if
link prober found link not in good state.
How I did it
Update the script to always provide initial values.
How to verify it
Tested on active-active dual-tor testbed.
Signed-off-by: Ying Xie ying.xie@microsoft.com
*Preventing ebtables rules to be applied on KVM image. The ebtables rules in SONiC are added to prevent ARP as well as L2 forwarding to be blocked in linux kernel since the hardware will take care of the actual L2 forward. However this is not the case with KVM where linux needs to forward even L2 packets
A change in sonic-utilities makes all cache files be saved into a
/tmp/cache. On swss restart this cache has to be removed in case swss
starts in cold or fast mode. A related cache restoration in the warmboot
finalizer script is also updated to use new location.
- Why I did it
To fix#9817. Clear the cache directory on swss.sh except for warm start.
Also, adopted finalize-warmboot script to take the cache directory.
- How I did it
A change in sonic-utilities makes all cache files be saved into a /tmp/cache. On swss restart this cache has to be removed in case swss starts in cold or fast mode. A related cache restoration in the warmboot finalizer script is also updated to use new location.
- How to verify it
Run togather with Azure/sonic-utilities#2232. Verify counters cache is removed on config reload, cold/fast reboots, swss restart.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
What I did:
Added bgp as a dependent of swss
Why I did it:
bgp container was not restarting on swss crash. When swss crashes, linkmgrd
doesn't initate a switchover because it cannot access the default route from
orchagent. Bringing down bgp with swss will isolate the ToR, causing linkmgrd
to initiate a switchover to the peer ToR avoiding significant packet loss.
How I did it:
Added bgp to DEPENDENT
Signed-off-by: Nikola Dancejic <ndancejic@microsoft.com>
Spanning from sonic-net/sonic-linkmgrd#76, this PR is to update warm restart finalizer to wait for linkmgrd to be reconciled.
sign-off: Jing Zhang zhangjing@microsoft.com
Why I did it
To make sure finalizer save config after linkmgrd's reconciliation.
How I did it
Add linkmgrd to the reconciliation wait list of warmboot finalizer.
How to verify it
Verified on lab device, linkmgrd reconciled as expected.
Fix in Monit memory_checker plugin. Skip fetching running containers if docker engine is down (can happen in deinit).
This PR fixes issue #11472.
Signed-off-by: liora liora@nvidia.com
Why I did it
In the case where Monit runs during deinit flow, memory_checker plugin is fetching the running containers without checking if Docker service is still running. I added this check.
How I did it
Use systemctl is-active to check if Docker engine is still running.
How to verify it
Use systemctl to stop docker engine and reload Monit, no errors in log and relevant print appears in log.
Which release branch to backport (provide reason below if selected)
The fix is required in 202205 and 202012 since the PR that introduced the issue was cherry picked to those branches (#11129).
What I did:
Following changes done for packet based chassis:-
1> Run arp_update on LC's to resolve static route nexthops over backend
port-channel interfaces.
2> On Supervisor make sure arp_update exit gracefully
- Why I did it
Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario
This is to port #11032 and #11299 from 202012 to master.
Support additional queue and PG in buffer templates, including both traditional and dynamic model
Support mapping DSCP 2/6 to lossless traffic in the QoS template.
Add macros to generate additional lossless PG in the dynamic model
Adjust the order in which the generic/dedicated (with additional lossless queues) macros are checked and called to generate buffer tables in common template buffers_config.j2
Buffer tables are rendered via using macros.
Both generic and dedicated macros are defined on our platform. Currently, the generic one is called as long as it is defined, which causes the generic one always being called on our platform. To avoid it, the dedicated macrio is checked and called first and then the generic ones.
Support MAP_PFC_PRIORITY_TO_PRIORITY_GROUP on ports with additional lossless queues.
On Mellanox-SN4600C-C64, buffer configuration for t1 is calculated as:
40 * 100G downlink ports with 4 lossless PGs/queues, 1 lossy PG, and 3 lossy queues
16 * 100G uplink ports with 2 lossless PGs/queues, 1 lossy PG, and 5 lossy queues
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
This PR is to add a flag to control whether to generate PORT_QOS_MAP|global entry or not.
It's because for some HWSKU, such as BackEndToRRouter and BackEndLeafRouter, there is no DSCP_TO_TC_MAP defined.
Hence, if the PORT_QOS_MAP|global entry is generated, OA will report some error because the DSCP_TO_TC_MAP map AZURE can not be found.
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- saiObjectTypeQuery: invalid object id oid:0x7fddb43605d0
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- meta_generic_validation_objlist: SAI_SWITCH_ATTR_QOS_DSCP_TO_TC_MAP:SAI_ATTR_VALUE_TYPE_OBJECT_ID object on list [0] oid 0x7fddb43605d0 is not valid, returned null object id
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- applyDscpToTcMapToSwitch: Failed to apply DSCP_TO_TC QoS map to switch rv:-5
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- doTask: Failed to process QOS task, drop it
This PR is to address the issue.
How I did it
Add a flag require_global_dscp_to_tc_map to control whether to generate the PORT_QOS_MAP|global entry. The default value for require_global_dscp_to_tc_map is true. If the device type is storage backend, the value is changed to false. Then the PORT_QOS_MAP|global entry is not generated.
How to verify it
Update the current test_qos_dscp_remapping_render_template to cover storage backend.
Why I did it
Storage backend has all vlan members tagged. If untagged packets are received on those links, they are accounted as RX_DROPS which can lead to false alarms in monitoring tools. Using this acl to hide these drops.
How I did it
Created a acl template which will be loaded during minigraph load for backend. This template will allow tagged vlan packets and dropped untagged
How to verify it
Unit tests
Signed-off-by: Neetha John <nejo@microsoft.com>