Commit Graph

1103 Commits

Author SHA1 Message Date
Bohan Yang
18bdd154a6 [Arista]Add media_settings.json for x86_64-arista_7800r3a_36d2_lc (#12444)
Why I did it
TX FIR tuning should be done based on the type of inserted transceiver

How I did it
Add media_settings.json which contains the tuning data for 100G optic and 400G optic.

How to verify it
Tested against x86_64-arista_7800r3a_36d2_lc
2022-11-28 18:49:17 +00:00
Vivek
db09bef671 [Mellanox] [SKU] Added Mellanox-SN4700-A96C8V8 SKU (#12347)
- Why I did it
A new SKU for MSN4700 Platform i.e. Mellanox-SN4700-V16A96

Requirements:

Breakout:
Port 1-24: 4x25G(4)[10G,1G]
Port 25-28: 2x100G[200G,50G,40G,25G,10G,1G]
Port 29-32: 2x200G[100G,50G,40G,25G,10G,1G]
Downlinks: 96 (1-24) + 4 (25-28)
Uplinks: 4 (29-32)
Shared Headroom: Enabled
Over Subscribe Ratio: 1:4
Default Topology: T0
Default Cable Length for T1: 5m
VxLAN source port range set: No
Static Policy Based Hashing Supported: No

Additional Details:
QoS params: The default ones defined in qos_config.j2 will be applied
Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used
SKU was drafted under the assumption that the downlink ports uses xcvr's that will only support the first 4 lanes of the physical port they are connected to. Hence for the ports 1-24, the last four lanes are not used
Cable Lengths used for generating buffer_defaults_{t0,t1}.j2 values

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-11-28 18:49:05 +00:00
Vivek
18a1252268 [Mellanox] [SKU] Mellanox-SN4700-V48C32 SKU added (#12250)
A new SKU for MSN4700 Platform i.e. Mellanox-SN4700-V48C32

Requirements:
Breakout:
Port 1-24: 2x200G
Port 25-32: 4x100G
Downlinks: 48 (1-24)
Uplinks: 32 (25-32)
Shared Headroom: Enabled
Over Subscribe Ratio: 1:8
Default Topology: T1
Default Cable Length for T1: 300m
VxLAN source port range set: No
Static Policy Based Hashing Supported: No
Additional Details:
QoS params: The default ones defined in qos_config.j2 will be applied
Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used
Cable Lengths used for generating buffer_defaults_{t0,t1}.j2 values

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-11-28 18:48:51 +00:00
Dror Prital
aeefeff4db
[Mellanox] add NVIDIA copyright header to new files added (#12710)
Why I did it
Add NVIDIA Copyright header for new "NVIDIA" files

How I did it
Add the copyright header as remark at the head of the file
2022-11-23 17:12:03 +02:00
andywongarista
c086987fc4
Mark thermals as not controllable (#12393) 2022-11-21 14:38:22 -08:00
Kebo Liu
f4806091bb [Mellanox] Add Sensor conf to support respined platforms(SN3700/SN3700C/SN4600C) (#11553)
- Why I did it
Add new sensor conf file to support respined platforms(SN3700/SN3700C/SN4600C)

- How I did it
Add new sensor conf
Update the get_sensors_conf_path scripts to apply the sensor conf according to the HW respin version info

- How to verify it
run platform test(including sensor test)

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-11-10 18:17:49 +00:00
Ying Xie
0d26dcb785 Enable Dx010 LPM (#12642)
Why I did it
DX010 platform has limited routing table size.

How I did it
Enabling LPM.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2022-11-10 18:16:06 +00:00
wenyiz2021
aaea93ce2d [Chassis] [Arista] correct platform.json for sup and LC6 names (#12627)
add platform.json separately for LC6 that has different name, bc of supporting macsec
Signed-off-by: Wenyi Zhang <wenyizhang@microsoft.com>
2022-11-10 18:15:58 +00:00
arlakshm
ce45f23a57 [chassis][Arista] add supervisor to the platform_env.conf (#12615)
Why I did it
Fixes #12614

How I did it
In the container_checker the database_chassis is added to expected container if device is supervisor
To detect the device is superviso, add supervisor=1 to the platform_env.conf of 7808 sup platform

How to verify it
run container_checker monit check
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
2022-11-10 18:15:42 +00:00
judyjoseph
ab713dcfb6 Use the macsec_enabled flag in platform to enable macsec feature state (#11998)
* Use the macsec_enabled flag in platform to enable macesc feature state
* Add macsec supported metadata in DEVICE_RUNTIME_METADATA
2022-11-10 18:08:42 +00:00
vmittal-msft
89ac469d62 Updated config files to disable DLR_INIT capability (#12401) 2022-10-25 20:42:28 +00:00
Sudharsan Dhamal Gopalarathnam
81486021c1 [Mellanox]Adding SKU Mellanox-SN2700-D44C10 (#12396)
#### Why I did it
To add new SKU Mellanox-SN2700-D44C10 with following requirements:

| Port configuration | Value |
| ------  |--------- |
 | Breakout mode for each port  |**Defined in port mapping** |
| Speed of the port |  **Defined in Port mapping** |
| Auto-negotiation enable/disable | **No setting required** |
| FEC mode | **No setting required** |
|Type of transceiver used | **Not needed**|

 Buffer configuration | Value
------  |---------
 Shared headroom | **Enabled**
 Shared headroom pool factor  |  **2**
 Dynamic Buffer | **Disable**
 In static buffer scenario how many uplinks and downlinks? | **44 x50G and 2x100G Downlinks 8x100G uplinks**
 2km cable support required? | **No**

Switch configuration | Value
------  |---------
 Warmboot enabled? | **yes**
 Should warmboot be added to SAI profile when enabled? | **yes**
 Is VxLAN source port range set? | **No**
 Should Vxlan source port range be added to SAI profile when set. | **No**
 Is Static Policy Based Hashing enabled? | **No**

Port Mapping

| Ports  | Mode      |
| ------  |--------- |
| 1,2      | 1x100G |
|  3-6    | 2x50G   | 
| 7-10   | 1x100G |
| 11-22 | 2x50G   |
| 23-26 | 1x100G | 
| 27-32 | 2x50G   |

Number of Uplinks / Downlinks:
TO topology: **44 x50G and 2x100G Downlinks 8x100G uplinks**.

#### How I did it
Defined the SKU as per requirements

#### How to verify it
Load the SKU and verify if all links come up and traffic passes.
2022-10-25 20:39:34 +00:00
henry huang
138c428dea fixed nokia platform m0 asic mismatch (#12148)
changed the platform device name under nokia directory; we now need to specify marvell armhf/arm64 to provide more accurate platform identity. otherwise onie discovery won't recognize the asic being installed.

Why I did it
when we load images using onie discovery, the process was failing because of marvell ASIC mismatch

How I did it
replace the platform asic with marvell-armhf under 7215

How to verify it
load a new image using http server and verify that the image can be loaded successfully
2022-10-25 20:38:45 +00:00
Ying Xie
6578b9d790 [RDMA] create split profiles for Arista-7050CX3-32S (#12228)
Moving buffer configuration files to sub folders to enable multiple buffer profiles. Otherwise, non-functional change.

Signed-off-by: Ying Xie ying.xie@microsoft.com
2022-10-25 20:37:57 +00:00
Bohan Yang
08da4efe34 Add 36 port 400g SKU for x86_64-arista_7800r3a_36d series of Linecards. (#11872)
Add 36 port 400g SKU for x86_64-arista_7800r3a_36d series of Linecards.
2022-10-25 20:36:37 +00:00
Sambath Kumar Balasubramanian
a4d6676f83 Add 36 port 100g sku for x86_64-arista_7800r3a_36d series of linecards. (#11813)
Add 36 port 100g sku for x86_64-arista_7800r3a_36d series of linecards.
2022-10-25 20:35:45 +00:00
Marty Y. Lok
626d516c54 [Nokia] Update Nokia platform IXR7250E device data (#11611)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-10-11 21:47:53 +00:00
andywongarista
2b36f81063
[202205][Arista] Fix content of platform.json for DCS-7050CX3-32S (#12265)
* Fix platform.json for 7050cx3

* Add platform_components.json
2022-10-06 08:05:46 -07:00
andywongarista
c6bcf24019 [Arista] Add components for 720DT-48S (#12217)
Why I did it
Add components data for sonic-mgmt testing

How I did it
Update platform.json and add platform_components.json

How to verify it
Ran sonic-mgmt tests (test_chassis and test_component)
2022-10-03 19:00:52 +00:00
Dror Prital
d5bd2dd6bf
[202205] [Mellanox] update NVIDIA copyright header for added files (#12126)
- Why I did it
Add NVIDIA Copyright header for new "NVIDIA" files

- How I did it
Add the copyright header as remark at the head of the file
2022-09-22 19:08:08 +03:00
Junhua Zhai
5479892d1b [PikeZ] Update port alias in Arista-720DT-48S (#12086)
Fix #12037, by following HLD https://github.com/sonic-net/SONiC/blob/master/doc/sonic-port-name.md.
2022-09-21 21:19:14 +00:00
Samuel Angebault
366ded2936 Implement ssd_util plugin for Arista products (#11981)
Why I did it
Some Arista products do not have an SSD but use an eMMC instead.
The SsdUtil plugin is therefore extended to support both.

How I did it
Implemented ssd_util.py platform plugin loaded by ssdutil.
This plugin fallback to the default SONiC implementation if the arista one can't be found.

How to verify it
Run show platform ssdhealth on a product with an eMMC
2022-09-21 21:16:03 +00:00
Mai Bui
a63af72142 [device/ruijie] Mitigation for security vulnerability #11779
Signed-off-by: maipbui maibui@microsoft.com
Why I did it
The xml.etree.ElementTree module is not secure against maliciously constructed data.
How I did it
Remove xml. Use lxml XML parsers package that prevent potentially malicious operation.
2022-09-21 21:14:14 +00:00
Maxime Lorrillere
458b12b4af [Chassis][Voq]Configure midplane network on supervisor (#11725)
Multi-asic Docker instances are created behind Docker's default bridge
which doesn't allow talking to other Docker instances that are in the
host network (like database-chassis).

On linecards, we configure midplane interfaces to let per-asic docker
containers talk to CHASSIS_DB on the supervisor through internal chassis
network.

On the supervisor we don't need to use chassis internal network, but we
still need a similar setup in order to allow fabric containers to talk
to database-chassis
2022-09-21 21:12:40 +00:00
bingwang-ms
96588d20e0 Map TC6 to Queue 1 for regular traffic (#11904)
Why I did it
This PR is to update TC_TO_QUEUE_MAP|AZURE for SKU Arista-7050CX3-32S-D48C8 and Arista-7260CX3 T0.

The change is only to align the TC_TO_QUEUE_MAP for regular traffic and bounced traffic. It has no impact on business because we have no traffic being mapped to TC2 or TC6.

How I did it
Update TC_TO_QUEUE_MAP|AZURE , and test cases as well.

How to verify it
Verified by running test case test_j2files.py

/sonic/src/sonic-config-engine$ python3 setup.py test -s tests/test_j2files.py
running test
......
----------------------------------------------------------------------
Ran 29 tests in 25.390s

OK
2022-09-08 16:34:31 +00:00
Kebo Liu
67d9acda39 [SN2201] remove extra empty lines in the pg_profile_lookup.ini (#11923)
- Why I did it
Remove extra empty lines in the SN2201 pg_profile_lookup.ini to make it aligned with other platforms.
This extra empty line could confuse some test cases which need to parse this file.

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-09-08 15:48:45 +00:00
Jiahua Wang
fa21a82d22
Add sai_mdio_access_clause22=1 in td3x2-a720dt-48s-flex.config.bcm (#11899)
Back port #11303 to 202205 branch manually
2022-09-01 09:21:59 +08:00
Dev Ojha
648ddee39c [Arista7050cx3] TD3 SKU changes for pg headroom value after interop testing with cisco 8102 (#11901)
Why I did it
After PFC interop testing between 8102 and 7050cx3, data packet losses were observed on the Rx ports of the 7050cx3 (inflow from 8102) during testing. This was primarily due to the slower response times to react to PFC pause packets for the 8102, when receiving such frames from neighboring devices. To solve for the packet drops, the 7050cx3 pg headroom size has to be increased to 160kB.

How I did it
Modified the xoff threshold value to 160kB in the pg_profile file to allow for the buffer manager to read that value when building the image, and configuring the device

How to verify it
run "mmuconfig -l" once image is built


Signed-off-by: dojha <devojha@microsoft.com>
2022-09-01 00:13:15 +00:00
saksarav-nokia
5f385de2b7 [Nokia][Nokia-IXR7250E-36x100G & Nokia-IXR7250E-36x400G] Update BCM (#11577)
config to support ERSPAN egress mirror and also set flag to preserve ECN
2022-09-01 00:05:12 +00:00
Samuel Angebault
31b208ecfc [Arista] Fix content of platform.json for DCS-720DT-48S (#11855)
Why I did it
Content of platform.json was outdated and some platform_tests/api of sonic-mgmt were failing.

How I did it
Added the necessary values to platform.json

How to verify it
Running platform_tests/api of sonic-mgmt should yield 100% passrate.
2022-09-01 00:01:45 +00:00
andywongarista
1e91ad314b Enable AN for Ethernet24-47 (#11839)
Enable port AN ON explicitly and then port will become (oper status) UP. Somehow those ports AN are not default ON in bcm sdk.
2022-08-31 23:57:31 +00:00
Junhua Zhai
2ff3b84ae8 Correct port index in Arista-720DT-48S/phy24_config.json (#11699)
Port index 22 is associated with phy23_config.json, then same port index 22 in phy24_config.json may cause gearbox port creation error. Port Ethernet22 maps to index 23.
2022-08-31 23:57:25 +00:00
andywongarista
1885e565eb
[Arista] Add missing configs for 720DT-48S (#11898)
Backport of #11362
2022-08-31 18:44:40 +08:00
andywongarista
0adfd724e6
[202205][Arista] Add initial support for 720DT-48S (#10656) (#11860)
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.

How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51
2022-08-30 12:39:26 +08:00
vmittal-msft
2eb6c3d03c PFCWD fix for multi port multi priority scenario for HWSKU Dell Z9332 (#11640)
PFCWD fix for multi port multi priority scenario for HWSKU Dell Z9332
2022-08-26 20:52:56 +00:00
Vivek
5654524a3e [Mellanox] [4700] Update platform capability file to support new breakout mode (#11614)
- Why I did it
This new breakout mode is required when a QSFP cable is used on the QSFP-DD supported 4700 port. since QSFP only uses the first 4 lanes, this mode is required to restrict the child ports to only use the first four lanes

- How I did it
Updated the platfrom.json file with the extended data

- How to verify it
Tested on one port:

root@msn-4700:/home/admin# show int status
  Interface                            Lanes    Speed    MTU    FEC    Alias    Vlan    Oper    Admin                                             Type    Asym PFC
-----------  -------------------------------  -------  -----  -----  -------  ------  ------  -------  -----------------------------------------------  ----------
  Ethernet0                                0      25G   9100    N/A    etp1a  routed      up       up                                  QSFP28 or later         N/A
  Ethernet1                                1      25G   9100    N/A    etp1b  routed    down       up                                              N/A         N/A
  Ethernet2                                2      25G   9100    N/A    etp1c  routed    down       up                                              N/A         N/A
  Ethernet3                                3      25G   9100    N/A    etp1d  routed    down       up                                              N/A         N/A

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-08-26 20:52:24 +00:00
saksarav-nokia
a5171349a7
[NOKIA][DEVICE]Updated BCM config file to disable the cmic dma abort during cold boot and recycle port setting (#11825)
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
2022-08-24 15:53:50 -07:00
Sambath Kumar Balasubramanian
1d627f73c8
[Chassis][Voq] Update bcm config file system_ref_core_clock_khz param for j2cplus linecards. (#11760)
Update the bcm config file system_ref_core_clock_khz param to
handlesystems with J2cplus linecards.
We need system_ref_core_clock_khz to be set to 1600000 for supporting j2
and j2cplus linecards on the same chassis.
2022-08-19 16:15:12 -07:00
DavidZagury
25e48f9a12 [Mellanox] Add support for Service Port in SN5600 (#11609)
- Why I did it
SN5600 has an additional service interface with a different parameters than other interfaces.

- How I did it
Added the etp65 interface with the correct parameters.

- How to verify it
Run platform test on SN5600 platform.
Check the service port can startup correctly.
2022-08-17 17:08:14 +00:00
Vivek
adccd64bb4 [Mellanox] [SKU] Mellanox-SN4700-C128 SKU added (#11574)
- Why I did it
New SKU for MSN-4700 Platform i.e. Mellanox-SN4700-C128

Requirements:
* Breakout: Port 1-32: 4x100G
* Downlinks: 120 (1-30)
* Uplinks: 8 (31-32)
* Shared Headroom: Enabled
* Over Subscribe Ratio: 1:8
* Default Topology: T2
* Default Cable Length for T2: 1500m
* QoS params: The default ones defined in qos_config.j2 will be applied
* Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used

Additional Details:
Switch Type has to be programmed as SpineRouter through config_db.json in DEVICE_METADATA|localhost|type field for the buffer values & cable lengths defined in the buffers_defaults_t2.j2 to apply on the device
Cable Lengths Used for generating buffer_defaults_{t0,t1,t2}.j2 values

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-08-11 16:17:39 +00:00
Stephen Sun
8a12a4ba02 Support queue 7 in dual ToR scenario (#11571)
Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-08-08 20:45:17 +00:00
bingwang-ms
fda1290926 Support different DSCP_TO_TC_MAP for T1 in dualtor deployment (#11569)
* Support different DSCP_TO_TC_MAP for T1 in dualtor deployment
2022-08-08 20:44:32 +00:00
kenneth-arista
2280f3854c [Arista] Enable larger number of LAGs on 7800 LCs (#11070)
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.

Why I did it
The SOC property changes are necessary to match #10519 which increases the number of system LAG IDs to 1024.

Description for the changelog
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
2022-08-08 20:40:54 +00:00
Samuel Angebault
cf282747e6 [Arista] Update configurations for 7800R3A-36D2 (#10987)
Why I did it
This linecard runs in multi-asic mode and therefore needs the use_pcie_id_chassis file to work properly.
The default_sku file was also missing which would break the boot when no minigraph is provided.

Description for the changelog
Add missing default_sku and use_pci_id_chassis configs for 7800R3A-36D2
2022-08-08 20:39:57 +00:00
Ikki Zhu
400b401f4b [hlx/sfp] fix hlx platform sfp+ tx disable issue (#11532)
Why I did it:
To fix hlx platform sfp+ module tx disable issue

How I did it:
Fix sfp+ tx disable function according SFF-8472 specification

Co-authored-by: Eric Zhu <erzhu@celestica.com>
2022-07-28 20:37:55 +00:00
Marty Y. Lok
948c932cee [Nokia][IXR7250E] Add Nokia platform Nokia-IXR7250E-36x100GE 100G line card device dat (#11382)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-07-28 20:34:05 +00:00
Stephen Sun
b4d8ee3fec [Mellanox] Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario (#11261)
- Why I did it
Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario
This is to port #11032 and #11299 from 202012 to master.

Support additional queue and PG in buffer templates, including both traditional and dynamic model
Support mapping DSCP 2/6 to lossless traffic in the QoS template.
Add macros to generate additional lossless PG in the dynamic model
Adjust the order in which the generic/dedicated (with additional lossless queues) macros are checked and called to generate buffer tables in common template buffers_config.j2
Buffer tables are rendered via using macros.
Both generic and dedicated macros are defined on our platform. Currently, the generic one is called as long as it is defined, which causes the generic one always being called on our platform. To avoid it, the dedicated macrio is checked and called first and then the generic ones.
Support MAP_PFC_PRIORITY_TO_PRIORITY_GROUP on ports with additional lossless queues.
On Mellanox-SN4600C-C64, buffer configuration for t1 is calculated as:

40 * 100G downlink ports with 4 lossless PGs/queues, 1 lossy PG, and 3 lossy queues
16 * 100G uplink ports with 2 lossless PGs/queues, 1 lossy PG, and 5 lossy queues

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-07-28 20:30:00 +00:00
Kebo Liu
67e46e1004 add flag skip_xcvrd_cmis_mgr to skip cmis task on Nvidia platform (#11120)
Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-07-28 20:26:25 +00:00
Kebo Liu
2f59460fc4 [Mellanox] Enhance Platform API to support SN2201 - RJ45 ports and new components mgmt. (#10377)
* Support new platform SN2201 and RJ45 port

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* remove unused import and redundant function

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* fix error introduced by rebase

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* Revert the special handling of RJ45 ports (#56)

* Revert the special handling of RJ45 ports

sfp.py
sfp_event.py
chassis.py

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove deadcode

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Support CPLD update for SN2201

A new class is introduced, deriving from ComponentCPLD and overloading _install_firmware
Change _install_firmware from private (starting with __) to protected, making it overloadable

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Initialize component BIOS/CPLD

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove swb_amb which doesn't on DVT board any more

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove the unexisted sensor - switch board ambient - from platform.json

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Do not report error on receiving unknown status on RJ45 ports

Translate it to disconnect for RJ45 ports
Report error for xSFP ports

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Add reinit for RJ45 to avoid exception

Signed-off-by: Stephen Sun <stephens@nvidia.com>

Co-authored-by: Stephen Sun <5379172+stephenxs@users.noreply.github.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
2022-07-28 20:24:49 +00:00
Neetha John
f92e3e8262 Update 7260 MMU and ECN settings (#11449)
Signed-off-by: Neetha John <nejo@microsoft.com>

Why I did it
Improve throughput and latency for 7260 deployments

How I did it
Update the dynamic threshold to 0 and ECN settings as 2mb/10mb/5%

How to verify it
Updated unit tests to use the modified values for 7260 ecn settings.
2022-07-22 22:14:41 +00:00