* Install ipaddress python package that has deprecated current ipaddr. ipaddress has backport to python2.7
* Install python ipaddress module as required by route_check.py sonic utility. BTW, ipaddress deprecates ipaddr and ipaddress has python2 backport
* Revert the old chaneg per review comments.
Signed-off-by: Renuka Manavalan <remanava@microsoft.com>
- Why it is required
since SONiC master switches ifupdown package to the new implementation (ifupdown2), it is required to change the configuration of a platform-specific interface for wedge100bf_32x and wedge100bf_65x platforms (bc of ifupdown2 doesn't support auto mode for inet6 protocol).
Also, need to make some refactoring and remove if platform == smth then.. from the system level scripts.
- What I did
removed customization of /usr/bin/interfaces-config.sh
explicitly created directory /etc/network/interfaces.d
added "source" to the /etc/network/interfaces generation template (to include platform-specific interfaces processing)
added platform-specific interfaces config itself (for wedge100bf_32x and wedge100bf_65x)
fixed testcase in sonic-config-engine
- How to verify it
build image for wedge100bf_32x
perform sudo config reload -y on new installation
check the correct configuration of usb0 interface
- Description for the changelog
Allow configuration of platform-specific interfaces
Lossy traffic does not need to be mapped to different ingress PGs. They can all share the same ingress PG.
Signed-off-by: Wenda Ni <wenni@microsoft.com>
start() is called by service startPre method, which is blocking. Starting
syncd service here is causing deadlock.
attach() is called by service start method, which is non-blocking.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [services] Ensure swss and syncd services start before dependent services
* Add 'attach' functions to scripts which get installed to /usr/local/bin so that services only reference the one script each
* Add 'After=swss.service' to syncd.service
We are going to use initramfs hook for firmware upgrades
To install Arista hook:
- create folder /mnt/flash/<image dir>/platform/hooks/boot1/ from Aboot or
/host/<image dir>/platform/hooks/boot1/ from Sonic
- add executable script to created folder
need to flush asic db in swss.sh instead of syncd.sh
orchagent might already started in swss.sh and put commands
into asic db before asic db is flushed in syncd.sh. This
causes race condition such as INIT_VIEW not passing to syncd.
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* Add a log message for each notification of add/del TACACS server.
Signed-off-by: Renuka Manavalan <remanava@microsoft.com>
* Moved another syslog message from DEBUG to INFO to be able to see those notifications.
All these changes are to help with a one-time-seen-bug, that hostcfgd did not act upon changes to redis for TACACS servers. We could not repro the bug.
Signed-off-by: Renuka Manavalan <remanava@microsoft.com>
* [build]: put stretch debian packages under target/debs/stretch/
* in stretch build phase, all debian packages built in that stage are placed under target/debs/stretch directory.
* for python-based debian packages, since they are really the same for jessie and stretch, they are placed under target/python-debs directory.
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* [updategraph] After system upgrade, restore files/directories with
original attributes etc.
Restore a few more files that was missed before.
Restore FRR configuration directory if exists on old system
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
* Removed deployment_id_asn_map.yml from copy list
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
* QoS config change: 1) DSCP mapping; 2) link pg/queue 6 to lossy buffer;
3) redistribute scheduler
Signed-off-by: Wenda <wenni@microsoft.com>
* Add scheduling weight to queue 2
Signed-off-by: Wenda <wenni@microsoft.com>
* Link pg/queue 2 to lossy buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the pg headroom for a7060-D48C8 50G
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for qos
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom size, and update egress lossy pool size accordingly
Signed-off-by: Wenda <wenni@microsoft.com>
* Update headroom pool size; Update ingress service pool and egress lossy
pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* a7260: update headroom pool size; Update ingress service pool and egress lossy pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* [reboot cause] Move reboot-cause files to /host directory so they persist across SONiC upgrades
* [sonic-utilities] Update submodule to include related changes
- What I did
This fix removes the possibility of 'localhost' entry getting removed from /etc/hosts file by hostname-config service.
Without this change, whenever we change the hostname from 'localhost' to any other name on the config_db.json and reload the config, /etc/hosts file will only have the new hostname on it. But there are multiple sonic utilities (eg: swssconfig) which relies on the hard coded 'localhost' name and they tend to stop working.
- How I did it
Added a new check on hostname-config.sh script to avid blindly deleting the line containing the old hostname from /etc/hosts file. Now it will delete the old hostname only if its not localhost or when the hostname is not changing.
- How to verify it
Bring up SONiC on a device with hostname as localhost
Edit /etc/sonic/config_db.json to update the 'hostname' filed under DEVICE_METADATA from "hostname" : "localhost" --> "hostname" : "sonic"
run config reload -y to reflect the hostname change done on config_db.json file.
cat /etc/hosts and check whether both 127.0.0.1 localhost and 127.0.0.1 sonic entry are present on the file.
ping localhost should work fine.
- Description for the changelog
Make hostname-config service more robust in handling SONiC hostname change from localhost to anything else.
* Perform stop/start of Mellanox driver tools for all types of reboot
* Don't set Mellanox FAST_BOOT option for "cold" reboot
* Don't send "syncd_request_shutdown" event for "cold" reboot on Mellanox platforms
Signed-off-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
* [security kernel] Upgrade kernel from 4.9.110-3+deb9u2 to 4.9.110-3+deb9u6
short version: 4.9.0-7 to 4.9.0-8
See changelogs for security fixes:
https://tracker.debian.org/media/packages/l/linux/changelog-4.9.110-3deb9u6
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
* Update sonic-linux-kernel submodule after it was merged
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
* [update graph] adapt to warm reboot scenario
When migrating configuration, always copy config files from old_config
to /etc/sonic. But if warm reboot is detected, then skip configuration
operations.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* log file copies and misses
* 1) DSCP 46 to 5; 2) ecn config for lossless traffic; 3) ecn on by default; 4) DWRR equal weight;
Signed-off-by: Wenda <wenni@microsoft.com>
* 1) link pg & queue 5 to lossy buffer profile; 2) ingress lossless alpha 1/8
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the test case for qos & buffer json template
Signed-off-by: Wenda <wenni@microsoft.com>
* Migrate a7050-qx32 and s6000 to use pg_profile lookup architecture
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom egress service pool for a7050-qx-32s, a7050-qx32, and s6000
Signed-off-by: Wenda <wenni@microsoft.com>
* Link queue 5 to lossy profile
Signed-off-by: Wenda <wenni@microsoft.com>
* Update arista drivers submodule
* Ignore the possible timestamp warning in tar extraction
* Add verbosity toggle to boot0
Console logging is slow because of the 9600 baud rate.
Some time can be saved by decreasing the console verbosity.
* Add hook mechanism in boot0.
Support additional features in boot0 via hooks.
Hooks are unpacked and executed at post-install or pre-exec time.
* Fix 7170 sensors.conf file
Fix critical temperature settings for MAX6658 sensors
* Fix the random swap of storage devices
For arista 7050 switches running with linux 4.9, it is likely the device
name of flash drive (/dev/sda) and usb (/dev/sdb) randomly swap in kernel
booting, depending on which one is ready first. It breaks the expectation
that flash will be mounted as root by setting root=/dev/sda1. This patch
will correct ROOT to flash device refering to the path under block_flash.
* Fix 7170 fancontrol
* Do not remove aquota.user file in boot0
This file is a filesystem protected file used by EOS.
It can be simply removed and will make the SONiC installation failed if
not skipped.
init_interfaces meant to be sonic init interfaces configuration file.
However, it needs to be copied to the right file name to take effect.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
There was a fix to speed up initialization when networking used init.d
but it did not carry over to systemd networking.service. This fix will
apply the same change on the systemd service.
The result is much less time spent being blocked in networking.service.
* [warmboot] Load database from `redis-cli save`
Signed-off-by: Qi Luo <qiluo-msft@users.noreply.github.com>
* Add trivial statement to make bash function valid
Signed-off-by: Qi Luo <qiluo-msft@users.noreply.github.com>
* Update submodule sonic-utilities: Use 'redis-cli save' to dump database to file
Signed-off-by: Qi Luo <qiluo-msft@users.noreply.github.com>
* Move configdb-load.sh outside docker, and only run in cold
Signed-off-by: Qi Luo <qiluo-msft@users.noreply.github.com>
* Fix for more strict warm check
Signed-off-by: Qi Luo <qiluo-msft@users.noreply.github.com>
This driver should be loaded by sonic service. If kernel tries to load
it, the driver would be loaded with default parameters, which is not
right for sonic.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Fix redis-py version
Signed-off-by: Qi Luo <qiluo-msft@users.noreply.github.com>
* Update submodule sonic-py-swsssdk: Fix redis-py version to 2.10.6
Signed-off-by: Qi Luo <qiluo-msft@users.noreply.github.com>
Clear WARM_RESTART table could cause component level warm restart to
fail due to missing WARM_RESTART state.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- cold shutdown is used by regular service stop and/or fast reboot
- warm shutdown is used by warm restart and/or warm reboot
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
This script shall not flush all the entries in the state database
when it starts up, since there are entries maintained and written
by other processes outside this docker.
The issue we noticed was that the portchannel states are cleaned
up after teamsyncd writes the entries into the database, which
causes the IPs failed to be configured because intfmgrd considers
the portchannels are not ready yet.
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
Auto negotiating console speed could cause sonic to lock on a wrong
speed under rare conditions. The only way to come out of the wrong
speed is to issue line break or restart console service with forced
speed, or reboot sonic.
Lock down the console speed to avoid these situations.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Remove the teamd.j2 templates used for starting the teamd. Add
teammgrd instead to manage all port channel related configuration
changes. Remove front panel port related configurations in
interfaces.j2 templates as well.
Remove teamd.sh script and use teammgrd to start all the teamd
processes. Remove all the logics in the start.sh script as well.
Update the sonic-swss submodule.
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
* Unify qos config with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change 7050 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: device/arista/x86_64-arista_7050_qx32/Arista-7050-QX32/qos.json.j2
modified: device/arista/x86_64-arista_7050_qx32s/Arista-7050-QX-32S/qos.json.j2
* Change a7060, a7260, s6000, s6100, z9100 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change mlnx devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: ../../../mellanox/x86_64-mlnx_msn2100-r0/ACS-MSN2100/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2410-r0/ACS-MSN2410/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/ACS-MSN2700/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/Mellanox-SN2700-D48C8/qos.json.j2
* Change barefoot devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: barefoot/x86_64-accton_wedge100bf_32x-r0/montara/qos.json.j2
modified: barefoot/x86_64-accton_wedge100bf_65x-r0/mavericks/qos.json.j2
* Change accton as7212 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: accton/x86_64-accton_as7212_54x-r0/AS7212-54x/qos.json.j2
* Apply PORT_QOS_MAP to active ports only
Signed-off-by: Wenda <wenni@microsoft.com>
* Update qos config test with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Update sample output of qos-dell6100.json
Signed-off-by: Wenda <wenni@microsoft.com>
* Remove generating the default port name and index list, i.e., remove the generate_port_lists macro, because PORT is always defined
Signed-off-by: Wenda <wenni@microsoft.com>
* Include pfc_to_pg_map according to platform asic type obtained from
/etc/sonic/sonic_version.yml rather than specifying per hwsku
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Customize TC_TO_PRIORITY_GROUP_MAP and
PFC_PRIORITY_TO_PRIORITY_GROUP_MAP for barefoot
Signed-off-by: Wenda <wenni@microsoft.com>
* Unify PFC_PRIORITY_TO_PRIORITY_GROUP_MAP: remove "0":"0", "1":"1" as
these two pgs do not generate PFC frames.
Signed-off-by: Wenda <wenni@microsoft.com>
Update the hw-mgmt to latest release V.2.0.0060.
Update the related files according to the latest hw-mgmt.
Signed-off-by: Kevin Wang <kevinw@mellanox.com>
Flashes used for the 7050QX-32 and 7050QX-32S have a fw issue.
The best option to solve the problem is to upgrade to a newer firmware.
However this can only be done while in memory and take 10 seconds.
Adding an upgrade mechanism is possible but would need more
consideration as flashing the firmware and reformating the flash will
exceed the fast-reboot requirements.
A quick mitigation is to align the ext4 partition that we create on
these vfat based system on a 4k boundary.
Here we chose 1M instead but it's the same.
Newer version of sfdisk do this automatically but the one in SONiC
today doesn't have this behavior.
This workaround will only reduce the pace of the flash health
degradation. The only long term fix is to flash the firmware.
* Adapt to the new WARM_RESTART_TABLE table schema: change from restart_count to restore_count
Signed-off-by: Jipan Yang <jipan.yang@alibaba-inc.com>
* Update variable and function name to match restore_count name change
Signed-off-by: Jipan Yang <jipan.yang@alibaba-inc.com>
* Update swss submodule for warm restart schema change
Signed-off-by: Jipan Yang <jipan.yang@alibaba-inc.com>
* [syncd] warn shutdown syncd process when warm boot is enabled
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [warmboot] mount folder to hold warmboot temporary files
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Fix a typo
* [swss.sh] refactor ssh service script code
- Move checks and waits to helper functions.
- Remove early returns from code stream
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [swss.sh] Add debug log for service state changes
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [syncd] Separate out syncd service from swss service
Still make them start/stop/restart synchronously so existing scripts
continue working.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Remove extra 'After' in swss service and remove syncd docker warm boot code
Syncd warm boot needs more thinking, we can put it back once the work
flow has been defined and ready for coding/testing.
* [syncd] syncd start/stop/restart shouldn't affect swss state
Semi-detach syncd service state change from swss:
- swss state change still chase syncd service to follow except warm boot
- syncd state change will only affect itself.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* add missing '{'
* [updategraph] add support to use preset config instead of default minigraph
* Fix variable case
* Remove default minigraph case
* Remove default minigraphs and add default_sku files
Currently setting the next boot image is the same as setting a default
image.
With this change SWI_DEFAULT= will be considered the default image and
SWI= the next image.
When executing the boot0 SWI= will be overriden by SWI_DEFAULT= if it
exists and create in with the value of SWI= otherwise.
On overlay filesystem the name of the mountpoint will also match in the
mount command for overlayfs as upperdir=
To prevent detecting the wrong partition we now look for space before.
This ensure that we match mountpoint and not devices in df and mount
outputs.
- Move front panel ports and port channels MTU and IP configurations out of
the current /etc/network/interfaces file and store them in the configuration
database.
- The default MTU value for both front panel ports and the port channels is
9100. They are set via the minigraph or 9100 by default.
- Introduce portmgrd which will pick up the MTU configurations from the
configuration database.
- The updated intfmgrd will pick up IP address changes from the configuration
database.
- Update sonic-swss submodule
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
Previously use / to separate container name and program name.
However, in rsyslogd:
Precisely, the programname is terminated by either (whichever occurs first):
end of tag
nonprintable character
‘:’
‘[‘
‘/’
The above definition has been taken from the FreeBSD syslogd sources.
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* Fix potential blackholing/looping traffic and refresh ipv6 neighbor to avoid CPU hit
In case ipv6 global addresses were configured on L3 interfaces and used for peering,
and routing protocol was using link-local addresses on the same interfaces as prefered nexthops,
the link-local addresses could be aged out after a while due to no activities towards the link-local
addresses themselves. And when we receive new routes with the link-local nexthops, SONiC won't insert
them to the HW, and thus cause looping or blackholing traffic.
Global ipv6 addresses on L3 interfaces between switches are refreshed by BGP keeplive and other messages.
On server facing side, traffic may hit fowarding plane only, and no refresh for the ipv6 neighbor entries regularly.
This could age-out the linux kernel ipv6 neighbor entries, and HW neighbor table entries could be removed,
and thus traffic going to those neighbors would hit CPU, and cause traffic drop and temperary CPU high load.
Also, if link-local addresses were not learned, we may not get them at all later.
It is intended to fix all above issues.
Changes:
Add ndisc6 package in swss docker and use it for ipv6 ndp ping to update the neighbors' state on Vlan interfaces
Change the default ipv6 neighbor reachable timer to 30mins
Add periodical ipv6 multicast ping to ff02::11 to get/refresh link-local neighbor info.
* Fix review comments:
Add PORTCHANNEL_INTERFACE interface for ipv6 multicast ping
format issue
* Combine regular L3 interface and portchannel interface for looping
* Add ndisc6 package to vs docker
* Added new platform support DellEMC - Z92264f - 64x100
* Includes changes with Makefiles, sfputil, eeprom and default minigraph
* Led support for Z9264f platform
* Includes changes on default minigraph
* ipmitool implementation in pmon docker. platform_sensors script is inclued in pmon startup