Why I did it
Add support for SFP refactor on Nokia-7215 Marvell armhf platform.
Platform: armhf-nokia_ixs7215_52x-r0
HwSKU: Nokia-7215
ASIC: marvell
Port Config: 48x1G + 4x10G (SFP+)
How I did it
Modify sfp.py to support SFP refactor optoe driver and platform.json to facilitate proper OC test completion.
How to verify it
Build armhf target for Nokia-7215 and verify proper Xcvrd and SFP refactor operation.
Why I did it
There is rare condition, emc2305 hold SMBus and cause SMBus completion wait timed out.
How I did it
Enable EMC2305 SMBus timeout feature, 30ms period of inactivity will reset the interface.
How to verify it
Use 'i2cget -y -f 23 0x4d 0x20 b' to read EMC2305 configuration register and check DIS_TO bit not set.
Signed-off-by: Eric Zhu <erzhu@celestica.com>
Why I did it
SDK patches for iproute2 were added to SONiC tree as a temporary solution.
Now that SDK with the patches is available, I have removed the patches from SONiC tree and we consume them from SDK github during compilation.
How I did it
During build we download SDK iproute2 patches from SDK github (or from the URL provided by user if compiling SDK from sources) and apply them before compilation.
How to verify it
Compile and load on switch, verify interfaces network devices created successfully.
Verify LLDP shows connections to neighbors.
Verify ping between 2 hosts over 2 router ports is successful.
Manual Cherrypick of #15260
Why I did it
Bug fix:
I2C bus is stuck - Unable to probe I2C bus 2-0048, which causes /var/run/hw-management/config/sfp_counter, module_counter to be zero and pmon docker unable to start.
Work item tracking
Microsoft ADO (number only):
How I did it
Update HW-MGMT package version in the make file
Update HW-MGMT submodule pointer
How to verify it
run full sonic-mgmt regression
Why I did it
ptf_nn_agent failed to start in dnx rpc syncd because module afpacket was not installed.
Please see issue sonic-net/sonic-mgmt#7822
How I did it
Add downloading ptf afpacket module in docker file.
How to verify it
Verified that ptf_nn_agent was started successfully in dnx rpc syncd with the change.
Fix watchdog reboot cause for wolverine linecard
Fix PSU fan speed of 0% by adding max RPM to most psu descriptions
Add product DCS-7060DX5-64
Add product DCS-7060DX5-32
- Why I did it
Mellanox syncd container will be based on Debian iproute2 plus patches instead of Nvidia internal version of iproute2
- How I did it
Download iproute2 from Debian repository, apply patches and compile to create a new target.
The target is then deployed in syncd container of Mellanox switches only.
The new target is called IPROUTE2_MLNX.
- How to verify it
Compile and load on switch, verify interfaces network devices created successfully.
Verify LLDP shows connections to neighbors.
Verify ping between 2 hosts over 2 router ports is successful.
Why I did it
After sonic-install install a new image, print_menu is set echo without any data. No image info between Hit any key to stop autoboot: 0 and Start USB
Board configuration detected:
Net:
| port | Interface | PHY address |
|--------|-----------|--------------|
No ethernet found.
Hit any key to stop autoboot: 0
(Re)start USB...
USB0: Port (usbActive) : 0 Interface (usbType = 2) : USB EHCI 1.00
scanning bus 0 for devices... 3 USB Device(s) found
scanning usb for storage devices... 0 Storage Device(s) found
How I did it
The fw_setenv print_menu is missing the double quotes. That causes the value is truncated. Using double quotes to in the environment setting.
How to verify it
Install new image with this fix. And reboot the system. The following section should be shown:
Signed-off-by: mlok <marty.lok@nokia.com>
[S6100] Improve S6100 serial-getty monitor, wait and re-check when getty not running to avoid false alert.
#### Why I did it
On S6100, the serial-getty service some time can't auto-restart by systemd. So there is a monit unit to check serial-getty service status and restart it.
However, this monit will report false alert, because in most case when serial-getty not running, systemd can restart it successfully.
To avoid the false alert, improve the monitor to wait and re-check.
Steps to reproduce this issue:
1. User login to device via console, and keep the connection.
2. User login to device via SSH, check the serial-getty@ttyS1.service service, it's running.
3. Run 'monit reload' from SSH connection.
4. Check syslog 1 minutes later, there will be false alert: ' 'serial-getty' process is not running'
#### How I did it
Add check-getty.sh script to recheck again later when getty service not running.
And update monit unit to check serial-getty service status with this script to avoid false alert.
#### How to verify it
Pass all UT.
Manually check fixed code work correctly:
```
admin@***:~$ sudo systemctl stop serial-getty@ttyS1.service
admin@***:~$ sudo /usr/local/bin/check-getty.sh
admin@***:~$ echo $?
1
admin@***:~$ sudo systemctl status serial-getty@ttyS1.service
● serial-getty@ttyS1.service - Serial Getty on ttyS1
Loaded: loaded (/lib/systemd/system/serial-getty@.service; enabled-runtime; vendor preset: enabled)
Active: inactive (dead) since Tue 2023-03-28 07:15:21 UTC; 1min 13s ago
admin@***:~$ sudo /usr/local/bin/check-getty.sh
admin@***:~$ echo $?
0
admin@***:~$ sudo systemctl status serial-getty@ttyS1.service
● serial-getty@ttyS1.service - Serial Getty on ttyS1
Loaded: loaded (/lib/systemd/system/serial-getty@.service; enabled-runtime; vendor preset: enabled)
```
syslog:
```
Mar 28 07:10:37.597458 *** INFO systemd[1]: serial-getty@ttyS1.service: Succeeded.
Mar 28 07:12:43.010550 *** ERR monit[593]: 'serial-getty' status failed (1) -- no output
Mar 28 07:12:43.010744 *** INFO monit[593]: 'serial-getty' trying to restart
Mar 28 07:12:43.010846 *** INFO monit[593]: 'serial-getty' stop: '/bin/systemctl stop serial-getty@ttyS1.service'
Mar 28 07:12:43.132172 *** INFO monit[593]: 'serial-getty' start: '/bin/systemctl start serial-getty@ttyS1.service'
Mar 28 07:13:43.286276 *** INFO monit[593]: 'serial-getty' status succeeded (0) -- no output
```
#### Description for the changelog
[S6100] Improve S6100 serial-getty monitor.
#### Ensure to add label/tag for the feature raised. example - PR#2174 under sonic-utilities repo. where, Generic Config and Update feature has been labelled as GCU.
Why I did it
Cherry-pick #14601, for code conflict.
Support to add SONiC OS Version in device info.
It will be used to display the version info in the SONiC command "show version". The version is used to do the FIPS certification. We do not do the FIPS certification on a specific release, but on the SONiC OS Version.
SONiC Software Version: SONiC.master-13812.218661-7d94c0c28
SONiC OS Version: 11
Distribution: Debian 11.6
Kernel: 5.10.0-18-2-amd64
Work item tracking
Microsoft ADO (number only): 17894593
How I did it
How to verify it
- Why I did it
In sfplpm API, the number of logical ports is hardcoded as 64. When a system contains more port than this, the SDK APIs would fail with a syslog as below
Mar 7 03:53:58.105980 r-leopard-58 ERR syncd#SDK: [MGMT_LIB.ERR] Slot [0] Module [0] has logport [0x00010069] in enabled state
Mar 7 03:53:58.105980 r-leopard-58 ERR syncd#SDK: [SDK_MGMT_LIB.ERR] Failed in __sdk_mgmt_phy_module_pwr_attr_set, error: Internal Error
Mar 7 03:53:58.106118 r-leopard-58 ERR pmon#-c: Error occurred when setting power mode for SFP module 0, slot 0, error code 1
- How I did it
Remove the hardcoded value of 64. Obtained the number of logical ports from SDK
- How to verify it
Manual testing
- Why I did it
To include latest fixes:
Fix traffic loss on all routed traffic when moving from 4.4.3372/XX_2008_3388 to 4.5.4118-012/XX_2010_4120-010. Issue occurred after ISSU process in Spectrum 1 only, When upgrading from older version to a new one. Neighbor entries are overwritten.
Fix When using mirror session policer on SPC2/3, the actual CIR was 1.28 times more than the configured CIR value.
Fix Creation of router interface of type bridge may occasionally fail if create is performed immediately after delete.
Fix False errors during SDK deinitialization may be seen in the syslog
- How I did it
Updated SDK submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
- Why I did it
Sometimes Nvidia watchdog device isn't ready when watchdog-control service is up after first installation from ONIE
need to delay watchdog control service to go up after hw-mgmt which gets devices up and ready
- How I did it
Delay Nvidia watchdog-control service before hw-mgmt has started on Mellanox platform in order to avoid missing or not ready watchdog device.
- How to verify it
verification test of ONIE installation of image in a loop
making sure watchdog service is always up (not failed) after first installation from ONIE
Why I did it
Update SAI xgs version to 8.4.0.2 and migrate xgs to DMZ repo.
How I did it
Update SAI xgs version in sai.mk.
How to verify it
Run the SONiC and SAI test with the8.4 SAI release pipeline.
Fixes#13568
Upgrade from old image always requires squashfs mount to get the next image FW binary. This can be avoided if we put FW binary under platform directory which is easily accessible after installation:
admin@r-spider-05:~$ ls /host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
/host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
admin@r-spider-05:~$ ls -al /tmp/image-fw-new-loc.0-dirty-20230208.193534-fs/etc/mlnx/fw-SPC.mfa
lrwxrwxrwx 1 root root 66 Feb 8 17:57 /tmp/image-fw-new-loc.0-dirty-20230208.193534-fs/etc/mlnx/fw-SPC.mfa -> /host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
- Why I did it
202211 and above uses different squashfs compression type that 201911 kernel can not handle. Therefore, we avoid mounting squashfs altogether with this change.
- How I did it
Place FW binary under /host/image-/platform/mlnx/, soft links in /etc/mlnx are created to avoid breaking existing scripts/automation.
/etc/mlnx/fw-SPCX.mfa is a soft link always pointing to the FW that should be used in current image
mlnx-fw-upgrade.sh is updated to prefer /host/image-/platform/mlnx location and fallback to /etc/mlnx in squashfs in case new location does not exist. This is necessary to do image downgrade.
- How to verify it
Upgrade from 201911 to master
master to 201911 downgrade
master -> master reboot
ONIE -> master boot (First FW burn)
Which release branch to backport (provide reason below if selected)
- Why I did it
On Mellanox platform, system EEPROM is a soft link provided by hw-management. There is chance that config-setup service accessing the EEPROM before hw-management creating it. It causes errors. The PR is aim to fix it.
- How I did it
Waiting EEPROM creation in platform API up to 10 seconds.
- How to verify it
Manual test
Why I did it
Command "sudo sfputil show error-status -hw" shows "OK (Not implemented)" in the output.
How I did it
Add a new SFP API get_error_description support in Nokia sonic-platform sfp.py module.
How to verify it
Run the new image and execute command "sudo sfputil show error-status -hw"
- Why I did it
Advance hw-mgmt service to V.7.0020.4100
Add missing thermal sensors that are supported by hw-mgmt package
Delay system health service before hw-mgmt has started on Mellanox platform in order to avoid reading some sensors before ready.
Depends on sonic-net/sonic-linux-kernel#305
- How I did it
1. Update hw mgmt version
2. Add missing sensors
3. Delay service
- How to verify it
Regression test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
Support per PSU slope value for PSU power threshold according to hardware team requirement
- How I did it
Pass the PSU number as a parameter when fetching the slope value of PSU.
- How to verify it
Running regression and manual test
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
Added platform specific script to be invoked during SAI failure dump. Added some generic changes to mount /var/log/sai_failure_dump as read write in the syncd docker
- How I did it
Added script in docker-syncd of mellanox and copied it to /usr/bin
- How to verify it
Manual UT and new sonic-mgmt tests
add SEU reporting on chassis
fix fallback logic for Clearlake eeprom identification
fix fan speed reporting for a specific model
move pcie timeout configuration for Upperlake in platform code (deprecates hwsku-init)
Why I did it
High CPU utilization by entropy.py
How I did it
Remove entropy script as it does not work anymore and is no longer needed for bullseye(202205).
In Buster(202012) the max available poolsize (entropy_avail) for entropy is 4096 and our entropy.py script was based on this value. With the change in kernel to bullseye on 202205 this entropy poolsize was changed to 256 which also causes our script to fail.
This script was initially added to provide SW assistance to improve the system entropy value available early on in the Sonic boot sequence on buster.
On bullseye (Linux kernel 5.10) this is no longer needed as this feature has been improved.
How to verify it
run "top" command to check CPU usage.
- Why I did it
To include latest fixes and new functionality
SDK/FW
1. Fixed bug in recovery mechanism in case of I2C error when trying to access the XSFP module.
2. On the NVIDIA Spectrum-2 switch, when receiving a packet with Symbol Errors on ports that are configured to cut-thought mode, a pipeline might get stuck.
3. On the Spectrum-2 and Spectrum-3 switch, if you enable ECN marking and the port is in split mode, traffic sent to the port under congestion (for example, when connecting two ports with a total speed of 50GbE to a single 25GbE port) is not marked.
4. Modifying existing entry/Adding new one when switch is at its maximum capacity (full by maximum allowed entries from any type such as routes, FDB, and so forth), will fail with an error.
5. When many ports are active (e.g., 70 ports up), and the configuration of shared buffer is applied on the fly, occasionally, the firmware might get stuck.
6. When a system has more than 256 ACL rules, on rare occasion, removing/adding rules may cause some ACL rules not to work.
7. On SN2201 system, on RJ45 port, the link might appear in 'down' state even if it operations properly.
8. Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event.
9. When setting LAG as a SPAN analyzer, the distributor mode of the LAG members was not taken into account. It may happen that the LAG member with distributor mode disabled will be set as a SPAN analyzer port.
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Add script usage and more information to script description being printed in help option.
- Why I did it
Missing information in script description in help option.
- How I did it
Expand script description and add script usage.
- How to verify it
Run the script with -h option.