* f4d9398 2020-04-07 | [vs] Set mto only on tap device (#592) [Kamil Cudnik]
* 0ad13f5 2020-04-07 | [lgtm]: add lgtm static analysis configuration (#589) [lguohan]
* c961260 2020-04-07 | add swss-common-{inc,lib} to specify the prefix of swss-common library (#590) [lguohan]
* 2d68abc 2020-04-06 | [syncd] Load correct global context id (#588) [Kamil Cudnik]
* cd82389 2020-04-06 | Return correct error code when port is in use (#565) [Vasant Patil]
* 2189c2f 2020-04-02 | [syncd] Pass correct switch RID when staring diag shell (#587) [Kamil Cudnik]
* 91792db 2020-04-01 | [syncd] Fix crash during stats polling (#586) [Vitaliy Senchyshyn]
* d13521e 2020-04-01 | [meta] Flush fdb entries after flush api success (#581) [Kamil Cudnik]
* 54b2510 2020-03-17 | [syncd] Use correct VID when GET will fail to obrain object type (#577) [Kamil Cudnik]
* 59b0430 2020-03-16 | [syncd] Unlock vendor api lock if enabling diag shell (#571) [Kamil Cudnik]
* 910d45e 2020-03-16 | [vs] Add more logs when setting MTU on port (#576) [Kamil Cudnik]
* c0d9947 2020-03-13 | [vs] Fix setting correct port mtu value (#573) [Kamil Cudnik]
- add "persistence" field for each redis instance in database_config.json
- we will use this information to decide if saving redis instance data while warm/fast reboot
- before multiDB changes, SONiC uses "redis-cli save " to save all the data into rdb file on default instance on port 6379
- with multiDB changes, we plan to implement "sonic-db-cli save" to save all data to corresponding rdb files on all listed redis instances which has "persistence" field set "yes"
sonic-netns-exec fails to execute below command in swss.sh:
sonic-netns-exec "$NET_NS" sonic-db-cli $1 EVAL "
local tables = {$2}
for i = 1, table.getn(tables) do
local matches = redis.call('KEYS', tables[i])
for j,name in ipairs(matches) do
redis.call('DEL', name)
end
end" 0
This command fails with error " redis.exceptions.ResponseError: value is not an integer or out of range" .
Root cause:
When sonic-netns-exec executes the above function, argument passed to sonic-db-cli is NOT executed as a single script.
The argument is passed as separate keywords to sonic-db-cli, as below:
['EVAL', 'local', 'tables', '=', "{'PORT_TABLE*'}", 'for', 'i', '=', '1,', 'table.getn(tables)', 'do', 'local', 'matches', '=', "redis.call('KEYS',", 'tables[i])', 'for', 'j,name', 'in', 'ipairs(matches)', 'do', "redis.call('DEL',", 'name)', 'end', 'end', '0']
- How I did it
To make sure that the parameters are passed as they were set initially, fix sonic-netns-exec to use double quoted "$@", where "$@" is "$1" "$2" "$3" ... "${N}"
After fix, the argument passed to sonic-db-cli is as below:
Argument passed to sonic-db-cli:
['EVAL', "\n local tables = {'PORT_TABLE*'}\n for i = 1, table.getn(tables) do\n local matches = redis.call('KEYS', tables[i])\n for j,name in ipairs(matches) do\n redis.call('DEL', name)\n end\n end", '0']
Signed-off-by: SuvarnaMeenakshi <sumeenak@microsoft.com>
libpython2.7, libdaemon0, libdbus-1-3, libjansson4 are common
across different containers. move them into docker-base-stretch
Signed-off-by: Guohan Lu <lguohan@gmail.com>
- This commit fixes the issue #4021 (Sensord not able to start up on
both master and 201911 branches)
- Add the new patch file for "lm-sensors" to perform dh_installinit to
include sensord.init in the packed deb. So that the missing init
script file for 'sensord' will be included in the created 'sensord'
deb.
Signed-off-by: Charlie Chen <charlie_chen@edge-core.com>
sai_xml contains info about port splits, previously it simply linked to the MSN3800 sai xml, which does not have splits. New version describes splits and speeds according to Mellanox-SN3800-D112-C8 SKU.
Practically it can cause port recreation on SAI init.
Signed-off-by: Mykola Faryma <mykolaf@mellanox.com>
* Fix bugs - "show run acl/interfaces" returns traceback when no ACL_RULE/INTERFACE is present in configuration
- Change logic in main to take data only if the var_json appears in DB.
- Add unit testing for bug fix & fix comments
Signed-off-by: Noa Or <noaor@mellanox.com>
As per SONiC CLI requirements, we wanted the collector port to default to 6343 if not explicitly configured. In the Click based CLI, if the collector port is omitted, the port will be set to 6343 by default (https://github.com/Azure/sonic-utilities/blob/master/config/main.py#L2543).
However, if sonic-mgmt-framework based CLI is used, hsflowd was using port 0 as default. host-sflow v2.0.26-4 addresses this issue (i.e. use 6343 in case “collector_port” is not set).
Upgrade hsflowd to v2.0.26-4 to pick up https://github.com/sflow/host-sflow/releases/tag/v2.0.26-4.
* Fix the CMD for the PROCESSSTATS entries so that
there is a space between the command name and the
arguments.
Signed-off-by: Garrick He <garrick_he@dell.com>
fix#4315
download and install cmake 3.13.2 from azure storage
latest cmake 3.16.3 from stretch-backports breaks the libyang 1.0.73 build
Signed-off-by: Guohan Lu <lguohan@gmail.com>
The following changes are included in this submodule advance
54b2510 [syncd] Use correct VID when GET will fail to obrain object type (#577)
59b0430 [syncd] Unlock vendor api lock if enabling diag shell (#571)
910d45e [vs] Add more logs when setting MTU on port (#576)
c0d9947 [vs] Fix setting correct port mtu value (#573)
798ce2f [multi-asic]: Update reload of systemd services to support multi-asic platforms (#856)
6f51428 [Mellanox] Fix thermal control issue: use natural sort for fan status and thermal status (#836)
51d26ce [ntp]: support "show ntp" with mgmt vrf based on linux os version (#858)
Signed-off-by: SuvarnaMeenakshi <sumeenak@microsoft.com>
* [thermal control] Fix pmon docker stop issue on 3800
* [thermal fix] Fix QA test issue
* [thermal fix] change psu._get_power_available_status to psu.get_power_available_status
* [thermal fix] adjust log for PSU absence and power absence
* [thermal fix] add unit test for loading thermal policy file with duplicate conditions in different policies
* [thermal] fix fan.get_presence for non-removable SKU
* [thermal fix] fix issue: fan direction is based on drawer
* Fix issue: when fan is not present, should not read fan direction from sysfs but directly return N/A
* [thermal fix] add unit test for get_direction for absent FAN
* Unplugable PSU has no FAN, no need add a FAN object for this PSU
* Update submodules
Co-authored-by: Stephen Sun <5379172+stephenxs@users.noreply.github.com>
* add MSN4700 device files
* update ACS-MSN4700 sai profile
* update buffer pool size, headroom, sensor conf, port config and reboot scripts
* fix ident
* update sensor conf and buffer pool
* [sn4700] add sku 4700 to chassis.py
* [Mellanox-4700] Add 4700 info to psu and thermal platform API
* update buffer config file template to the latest.
update SAI profile to use 100G X 4lanes for now
update port_config.ini according to the SAI profile
* [Mellanox]Update the buffer configurations for 4700
* fix alignment in pg_profile_lookup.ini
* add platform components file for new sku
* Update device/mellanox/x86_64-mlnx_msn4700-r0/ACS-MSN4700/pg_profile_lookup.ini
Co-Authored-By: Nazarii Hnydyn <nazariig@mellanox.com>
* remove redundant line
* [Mellanox]Correct type, buffer size
Co-authored-by: Nazarii Hnydyn <nazariig@mellanox.com>
Co-authored-by: junchao <junchao@mellanox.com>
Co-authored-by: Stephen Sun <stephens@mellanox.com>
maintains backward compatibility to search original x509 location
when telemetry table does not have certs
Signed-off-by: Guohan Lu <lguohan@gmail.com>