After pinging any failed IPv6 neighbor entries, set the remaining failed/incomplete entries to a permanent INCOMPLETE state. This manual setting to INCOMPLETE prevents these entries from automatically transitioning to FAILED state, and since they are now incomplete any subsequent NA messages for these neighbors is able to resolve the entry in the cache.
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
It could happen that a container has already crashed but docker-wait-any
will wait forever till it starts. It should, however, immediately exit
to make the serivce restart.
#### Why I did it
It is observed in some circumstances that the auto-restart mechanism does not work. Specifically for ```swss.service```, ```orchagent``` had crashed before ```docker-wait-any``` started in ```swss.sh```. This led ```docker-wait-any``` wait forever for ```swss``` to be in ```"Running"``` state and it results in:
```
CONTAINER ID IMAGE COMMAND CREATED STATUS PORTS NAMES
1abef1ecebff bcbca2b74df6 "/usr/local/bin/supe…" 22 hours ago Up 22 hours what-just-happened
3c924d405cd5 docker-lldp:latest "/usr/bin/docker-lld…" 22 hours ago Up 22 hours lldp
eb2b12a98c13 docker-router-advertiser:latest "/usr/bin/docker-ini…" 22 hours ago Up 22 hours radv
d6aac4a46974 docker-sonic-mgmt-framework:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours mgmt-framework
d880fd07aab9 docker-platform-monitor:latest "/usr/bin/docker_ini…" 22 hours ago Up 22 hours pmon
75f9e22d4fdd docker-snmp:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours snmp
76d570a4bd1c docker-sonic-telemetry:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours telemetry
ee49f50344b3 docker-syncd-mlnx:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours syncd
1f0b0bab3687 docker-teamd:latest "/usr/local/bin/supe…" 22 hours ago Up 22 hours teamd
917aeeaf9722 docker-orchagent:latest "/usr/bin/docker-ini…" 22 hours ago Exited (0) 22 hours ago swss
81a4d3e820e8 docker-fpm-frr:latest "/usr/bin/docker_ini…" 22 hours ago Up 22 hours bgp
f6eee8be282c docker-database:latest "/usr/local/bin/dock…" 22 hours ago Up 22 hours database
```
The check for ```"Running"``` state is not needed because for cold boot case we do ```start_peer_and_dependent_services``` and for warm boot case the loop will retry to wait for container if this container is doing warm boot:
d01a91a569/files/image_config/misc/docker-wait-any (L56)
#### How I did it
Removed the check for ```"Running"```.
#### How to verify it
Kill swss before ```docker-wait-any``` is reached and verify auto restart will restart swss serivce.
As part of PR #11754
Change was added to use variable SONIC_DB_NS_CLI for
namespace but that will not work since ./files/scripts/syncd_common.sh
uses SONIC_DB_CLI. So revert back to use SONIC_DB_CLI and define new
variable for SONIC_GLOBAL_DB_CLI for global/host db cli access
Also fixed DB_CLI not working for namespace.
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.
How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51
Change `sxdkernel start` to `sxdkernel restart`. If `syncd` service crashes in `ExecStartPre` systemd will not call `ExecStop` and thus will not call `sxdkernel stop`. Use of `sxdkernel restart` is more robust in terms of guarantees to restore the system after unexpected crashes.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Why I did it
On a supervisor card in a chassis, syncd/teamd/swss/lldp etc dockers are created for each Switch Fabric card. However, not all chassis would have all the switch fabric cards present. In this case, only dockers for Switch Fabrics present would be created.
The monit 'container_checker' fails in this scenario as it is expecting dockers for all Switch Fabrics (based on NUM_ASIC defined in asic.conf file).
This was done manually, to try to get past a build error due to changing
package versions in Debian.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did:
In case of multi-asic platforms gbsyncd is not getting added to Feature Table of Host Config DB. Without this container_checker complains of not needed gbsyncd container's are running.
How I did:
Update Both Host and Namespace config db when gbsyncd docker is starting.
How I verify:
Verified on Multi-asic platforms.
bgp should be a per-asic service, and runs for each namespace on
multi-asic platforms. However, putting bgp in MULTI_INST_DEPENDENT
causes swss to be restarted as well as bgp. this is causing issues after #11000
Issue: #11653
This fix:
removes bgp from dependents list
adds a conditional that either adds bgp, or bgp@$DEV to separate
between single and multi-asic platforms
Cherry pick PR https://github.com/sonic-net/sonic-buildimage/pull/10825 to 202205 branch
#### Why I did it
Fix sonic-db-cli high CPU usage on SONiC startup issue: https://github.com/sonic-net/sonic-buildimage/issues/10218
ETA of this issue will be 2022/05/31
#### How I did it
Re-write sonic-cli with c++ in sonic-swss-common: https://github.com/sonic-net/sonic-swss-common/pull/607
Modify swss-common rules and slave.mk to install c++ version sonic-db-cli.
#### How to verify it
Pass all E2E test scenario.
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
#### Description for the changelog
Build and install c++ version sonic-db-cli from swss-common.
#### Link to config_db schema for YANG module changes
<!--
Provide a link to config_db schema for the table for which YANG model
is defined
Link should point to correct section on https://github.com/Azure/SONiC/wiki/Configuration.
-->
#### A picture of a cute animal (not mandatory but encouraged)
In arp_update, check for FAILED or INCOMPLETE kernel neighbor entries and manually ping them to try and resolve the neighbor
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
When using trap on SIGTERM the script will not react to the SIGTERM signal sent while a child is executing.
I.e, the following script does not react on SIGTERM sent to it if it is
waiting for sleep to finish:
```
trap "echo Handled SIGTERM" 0 2 3 15
echo "Before sleep"
sleep inf
echo "After sleep"
```
Instead, trap only on EXIT which covers also a scenario with exit on
SIGINT, SIGTERM.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Why I did it
The initial value has to be present for the state machines to work. In active-standby dual-tor scenario, or any hardware mux scenario, the value will be updtaed eventually with a delay.
However, in active-active dual-tor scenario, there is no other mechanism to initialize the value and get state machines started.
So this script will have to write something at start up time.
For active-active dualtor, 'active' is a more preferred initial value, the state machine will switch the state to standby soon if
link prober found link not in good state.
How I did it
Update the script to always provide initial values.
How to verify it
Tested on active-active dual-tor testbed.
Signed-off-by: Ying Xie ying.xie@microsoft.com
*Preventing ebtables rules to be applied on KVM image. The ebtables rules in SONiC are added to prevent ARP as well as L2 forwarding to be blocked in linux kernel since the hardware will take care of the actual L2 forward. However this is not the case with KVM where linux needs to forward even L2 packets
A change in sonic-utilities makes all cache files be saved into a
/tmp/cache. On swss restart this cache has to be removed in case swss
starts in cold or fast mode. A related cache restoration in the warmboot
finalizer script is also updated to use new location.
- Why I did it
To fix#9817. Clear the cache directory on swss.sh except for warm start.
Also, adopted finalize-warmboot script to take the cache directory.
- How I did it
A change in sonic-utilities makes all cache files be saved into a /tmp/cache. On swss restart this cache has to be removed in case swss starts in cold or fast mode. A related cache restoration in the warmboot finalizer script is also updated to use new location.
- How to verify it
Run togather with Azure/sonic-utilities#2232. Verify counters cache is removed on config reload, cold/fast reboots, swss restart.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
What I did:
Added bgp as a dependent of swss
Why I did it:
bgp container was not restarting on swss crash. When swss crashes, linkmgrd
doesn't initate a switchover because it cannot access the default route from
orchagent. Bringing down bgp with swss will isolate the ToR, causing linkmgrd
to initiate a switchover to the peer ToR avoiding significant packet loss.
How I did it:
Added bgp to DEPENDENT
Signed-off-by: Nikola Dancejic <ndancejic@microsoft.com>
Spanning from sonic-net/sonic-linkmgrd#76, this PR is to update warm restart finalizer to wait for linkmgrd to be reconciled.
sign-off: Jing Zhang zhangjing@microsoft.com
Why I did it
To make sure finalizer save config after linkmgrd's reconciliation.
How I did it
Add linkmgrd to the reconciliation wait list of warmboot finalizer.
How to verify it
Verified on lab device, linkmgrd reconciled as expected.
Fix in Monit memory_checker plugin. Skip fetching running containers if docker engine is down (can happen in deinit).
This PR fixes issue #11472.
Signed-off-by: liora liora@nvidia.com
Why I did it
In the case where Monit runs during deinit flow, memory_checker plugin is fetching the running containers without checking if Docker service is still running. I added this check.
How I did it
Use systemctl is-active to check if Docker engine is still running.
How to verify it
Use systemctl to stop docker engine and reload Monit, no errors in log and relevant print appears in log.
Which release branch to backport (provide reason below if selected)
The fix is required in 202205 and 202012 since the PR that introduced the issue was cherry picked to those branches (#11129).
What I did:
Following changes done for packet based chassis:-
1> Run arp_update on LC's to resolve static route nexthops over backend
port-channel interfaces.
2> On Supervisor make sure arp_update exit gracefully
- Why I did it
Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario
This is to port #11032 and #11299 from 202012 to master.
Support additional queue and PG in buffer templates, including both traditional and dynamic model
Support mapping DSCP 2/6 to lossless traffic in the QoS template.
Add macros to generate additional lossless PG in the dynamic model
Adjust the order in which the generic/dedicated (with additional lossless queues) macros are checked and called to generate buffer tables in common template buffers_config.j2
Buffer tables are rendered via using macros.
Both generic and dedicated macros are defined on our platform. Currently, the generic one is called as long as it is defined, which causes the generic one always being called on our platform. To avoid it, the dedicated macrio is checked and called first and then the generic ones.
Support MAP_PFC_PRIORITY_TO_PRIORITY_GROUP on ports with additional lossless queues.
On Mellanox-SN4600C-C64, buffer configuration for t1 is calculated as:
40 * 100G downlink ports with 4 lossless PGs/queues, 1 lossy PG, and 3 lossy queues
16 * 100G uplink ports with 2 lossless PGs/queues, 1 lossy PG, and 5 lossy queues
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
This PR is to add a flag to control whether to generate PORT_QOS_MAP|global entry or not.
It's because for some HWSKU, such as BackEndToRRouter and BackEndLeafRouter, there is no DSCP_TO_TC_MAP defined.
Hence, if the PORT_QOS_MAP|global entry is generated, OA will report some error because the DSCP_TO_TC_MAP map AZURE can not be found.
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- saiObjectTypeQuery: invalid object id oid:0x7fddb43605d0
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- meta_generic_validation_objlist: SAI_SWITCH_ATTR_QOS_DSCP_TO_TC_MAP:SAI_ATTR_VALUE_TYPE_OBJECT_ID object on list [0] oid 0x7fddb43605d0 is not valid, returned null object id
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- applyDscpToTcMapToSwitch: Failed to apply DSCP_TO_TC QoS map to switch rv:-5
Jul 14 00:24:40.286767 str2-7050qx-32s-acs-03 ERR swss#orchagent: :- doTask: Failed to process QOS task, drop it
This PR is to address the issue.
How I did it
Add a flag require_global_dscp_to_tc_map to control whether to generate the PORT_QOS_MAP|global entry. The default value for require_global_dscp_to_tc_map is true. If the device type is storage backend, the value is changed to false. Then the PORT_QOS_MAP|global entry is not generated.
How to verify it
Update the current test_qos_dscp_remapping_render_template to cover storage backend.
Why I did it
Storage backend has all vlan members tagged. If untagged packets are received on those links, they are accounted as RX_DROPS which can lead to false alarms in monitoring tools. Using this acl to hide these drops.
How I did it
Created a acl template which will be loaded during minigraph load for backend. This template will allow tagged vlan packets and dropped untagged
How to verify it
Unit tests
Signed-off-by: Neetha John <nejo@microsoft.com>
- Why I did it
New security feature for enforcing strong passwords when login or changing passwords of existing users into the switch.
- How I did it
By using mainly Linux package named pam-cracklib that support the enforcement of user passwords, the daemon named hostcfgd, will support add/modify password policies that enforce and strengthen the user passwords.
- How to verify it
Manually Verification-
1. Enable the feature, using the new sonic-cli command passw-hardening or manually add the password hardening table like shown in HLD by using redis-cli command
2. Change password policies manually like in step 1.
Notes:
password hardening CLI can be found in sonic-utilities repo-
P.R: Add support for Password Hardening sonic-utilities#2121
code config path: config/plugins/sonic-passwh_yang.py
code show path: show/plugins/sonic-passwh_yang.py
3. Create a new user (using adduser command) or modify an existing password by using passwd command in the terminal. And it will now request a strong password instead of default linux policies.
Automatic Verification - Unitest:
This PR contained unitest that cover:
1. test default init values of the feature in PAM files
2. test all the types of classes policies supported by the feature in PAM files
3. test aging policy configuration in PAM files
Avoid write_standby in warm restart context.
sign-off: Jing Zhang zhangjing@microsoft.com
Why I did it
In warm restart context, we should avoid mux state change.
How I did it
Check warm restart flag before applying changes to app db.
How to verify it
Ran write_standby in table missing, key missing, field missing scenarios.
Did a warm restart, app db changes were skipped. Saw this in syslog:
WARNING write_standby: Taking no action due to ongoing warmrestart.
Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.
Why I did it
Support to use symbol links in platform folder to reduce the image size.
The current solution is to copy each lazy installation targets (xxx.deb files) to each of the folders in the platform folder. The size will keep growing when more and more packages added in the platform folder. For cisco-8000 as an example, the size will be up to 2G, while most of them are duplicate packages in the platform folder.
How I did it
Create a new folder in platform/common, all the deb packages are copied to the folder, any other folders where use the packages are the symbol links to the common folder.
Why platform.tar?
We have implemented a patch for it, see #10775, but the problem is the the onie use really old unzip version, cannot support the symbol links.
The current solution is similar to the PR 10775, but make the platform folder into a tar package, which can be supported by onie. During the installation, the package.tar will be extracted to the original folder and removed.
- Why I did it
When LLDP is disabled through feature command, it gets spawned after reboot.
- How I did it
In syncd.sh check if the service is enabled before spawning automatically during cold reboot.
- How to verify it
Disable lldp feature. Perform cold reboot and verify its not spawned.
Signed-off-by: bingwang <bingwang@microsoft.com>
Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950
SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64
How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.
For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7
How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
This PR aims to fix an issue (#10088) by enhancing the script memory_checker.
Specifically, if container is not created successfully during device is booted/rebooted, then memory_checker do not need check its memory usage.
How I did it
In the script memory_checker, a function is added to get names of running containers. If the specified container name is not in current running container list, then this script will exit without checking its memory usage.
How to verify it
I tested on a lab device by following the steps:
Stops telemetry container with command sudo systemctl stop telemetry.service
Removes telemetry container with command docker rm telemetry
Checks whether the script memory_checker ran by Monit will generate the syslog message saying it will exit without checking memory usage of telemetry.
- Why I did it
Recent change to delay PMON service in case of fast/warm reboot introduce an issue when restarting only SWSS service after fast/warm reboot for Nvidia platform.
Since the timer is triggered only when the system boot, in a scenario when the system is after a fast/warm reboot and the user restart SWSS service, as part of syncd.sh script, PMON service will stop but the timer will not start again.
- How I did it
On syncd.sh script, in case of fast/warm indication, check if pmon.timer is running.
If it is running it means we are at the first boot and continue normally.
If it is not running, meaning the service was restarted, start the timer to keep the system behavior consistent.
- How to verify it
Run fast/warm reboot.
service swss restart.
Observe PMON service starting.
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>