- Why I did it
Added the fwtrace config files in order to be able to call the mlxstrace utility during the show techsupport dump.
Work item tracking
Microsoft ADO (number only):
- How I did it
Added fwtrace config files. Added path to these files to sai.profile for each mlnx device.
- How to verify it
Execute the show techsupport command and check if mlxstrace output is in system dump.
Signed-off-by: vadymhlushko-mlnx <vadymh@nvidia.com>
#### Why I did it
To add new SKU Mellanox-SN4700-O8C48 with following requirements:
| Port configuration | Value |
| ------ |--------- |
| Breakout mode for each port |**Defined in port mapping** |
| Speed of the port | **Defined in Port mapping** |
| Auto-negotiation enable/disable | **No setting required** |
| FEC mode | **No setting required** |
|Type of transceiver used | **Not needed**|
Buffer configuration | Value
------ |---------
Shared headroom | **Enabled**
Shared headroom pool factor | **2**
Dynamic Buffer | **Disable**
In static buffer scenario how many uplinks and downlinks? | **48x100G Downlinks and 8x400G uplinks**
2km cable support required? | **Yes**
Switch configuration | Value
------ |---------
Warmboot enabled? | **yes**
Should warmboot be added to SAI profile when enabled? | **yes**
Is VxLAN source port range set? | **No**
Should Vxlan source port range be added to SAI profile when set. | **No**
Is Static Policy Based Hashing enabled? | **No**
Port Mapping
| Ports | Mode |
| ------ |--------- |
| 1-12 | 2x100G |
| 13-20 | 1x400G |
| 21-32 | 2x100G |
Number of Uplinks / Downlinks:
T1 topology: **48x100G Downlinks 8x400G uplinks**.
Length of downlink: **40m**
Length of uplink: **2000m**
##### Work item tracking
- Microsoft ADO **(number only)**:
#### How I did it
Defined the SKU as per requirements
#### How to verify it
Load the SKU and verify if all links come up and traffic passes.