Why I did it
[Build] Fix the docker-sync not found issue
How I did it
When SONIC_CONFIG_USE_NATIVE_DOCKERD_FOR_BUILD not enabled, not to remove the docker-sync tag.
Co-authored-by: xumia <59720581+xumia@users.noreply.github.com>
Add dualtor test jobs using TestbedV2 in 202205 branch.
Why I did it
Add dualtor test jobs using TestbedV2 in 202205 branch.
How I did it
Add dualtor test jobs using TestbedV2 in 202205 branch.
Signed-off-by: Yutong Zhang <yutongzhang@microsoft.com>
- Why I did it
Add new sensor conf file to support respined platforms(SN3700/SN3700C/SN4600C)
- How I did it
Add new sensor conf
Update the get_sensors_conf_path scripts to apply the sensor conf according to the HW respin version info
- How to verify it
run platform test(including sensor test)
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* Build docker-gbsyncd-broncos image
* Correct typo in LIBSAI_BRONCOS_URL_PREFIX
* Update docker-gbsyncd-broncos/Dockerfile.j2
* Enable debug shell support on docker-gbsyncd-broncos
* Include bcmsh in docker-gbsyncd-broncos
Why I did it
In docker-gbsyncd-broncos image, enable debug shell support for BRCM broncos PHY.
How I did it
How to verify it
Note: need enable attr SAI_SWITCH_ATTR_SWITCH_SHELL_ENABLE support in BCM PAI library
# bcmsh
Press Enter to show prompt.
Press Ctrl+C to exit.
NOTICE: Only one bcmsh or bcmcmd can connect to the shell at same time.
BRCM:> help
help
List of available commands
- h or help => Print command menu
- l => Print list of active ports on the PHY
- ps <port_id> <options> => Print port status
<options> => 1 -> Link status
=> 2 -> Link training failure status
=> 3 -> Link training RX status
=> 4 -> PRBS lock status
=> 5 -> PRBS lock loss status
- rd <port_id> <addr> <no of registers to read> => Read register contents
- wr <port_id> <addr> <data> => Write register data
- rrd <lanemap> <if_side> <addr> <no of registers to read> => Raw read register contents using lanemap and if_side (line = 0, system = 1)
- rwr <lanemap> <if_side> <addr> <data> => Raw write register data using lanemap and if_side (line = 0, system = 1)
- fw or firmware => Print firmware version of the PHY
- pd or port_dump <port_id> <flags> => Dump port status
- eyescan <port_id> => Display eye scan
- fec_status <port_id> => Get fec status of the port
- polarity <lanemap> <if_side> <TX polarity> <RX Polarity> => Set TX and RX polarity
<lanemap> => 0xF, 0xFF, or 0xFFFF based on number of lanes
<if_side > => Line = 0, System = 1
<TX/RX Polarity> =>_TX/RX Polarity bitmap of all lanes
Each bit represents a lane number.
E.g. Lane 0's polarity value (0 or 1) is populated in Bit 0.
- polarity <lanemap> <if_side> => Print TX and RX polarity
- lb <port_id> <lb_value> => Enable loopback on the port
lb_value = 0 -> Disable, 1 -> PHY, 2 -> MAC
- lb <port_id> => Print loopback configuration of the port
- prbs <port_id> <options> <val> => Set/Get PRBS configuration
<options> => 1 -> Get PRBS state and polynomial
2 -> Set PRBS Polynomial, <val> - PRBS Polynomial
Please refer to phy/chip documentation for valid values
3 -> Enable PRBS
<val> => 0 Disable PRBS
1 Enable both PRBS Transmitter and Receiver
2 Enable PRBS Receiver
3 Enable PRBS Transmitter
exit or q => Exit the diagnostic shell
Why I did it
Fixes#12614
How I did it
In the container_checker the database_chassis is added to expected container if device is supervisor
To detect the device is superviso, add supervisor=1 to the platform_env.conf of 7808 sup platform
How to verify it
run container_checker monit check
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
- Why I did it
Update SN2201 dynamic minimum fan speed table according to data provided by the thermal team.
- How I did it
Update the thermal table in device_data.py
- How to verify it
Run platform related regression
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Fix logrotate firstaction script to reflect correct size. The size was modified to change dynamically based on disk size. However this variable was not updated
#9504
- How I did it
Updated the variable based on disk size
- How to verify it
Verify in the generated rsyslog file if the variable is correctly generated from jinja template
Why I did it
[Build] Fix the docker-sync not found issue
How I did it
When SONIC_CONFIG_USE_NATIVE_DOCKERD_FOR_BUILD not enabled, not to remove the docker-sync tag.
Why I did it
nameserver and domain entries from build system fsroot gets into sonic image.
How I did it
Clear /etc/resolv.conf before building image
How to verify it
Built image with it and verified with install that /etc/resolv.conf is empty
- Why I did it
Update SDK/FW version - 4.5.3186/2010_3186 in order to have the following changes:
New functionality:
1. Added support for 6.5W (Class 8) in ports 49-50, 53-54, 57-58, and 61-62 on SN4600 system
Fix the following issues:
1. On very rare occasion (~1/100K), during I2C transaction with MMS1V50-WM and MMS1V90-WR modules on SN4700 system, the module may send unexpected stop which violate the I2C specification, possibly affecting the link up flow
2. When running 1GbE speeds on SN4600 system, the port remained active while peer side was closed
3. While toggling the cable with ‘sfputil lpmode on/off’, error msg like “ERR pmon#xcvrd: Receive PMPE error event on module 1: status {X} error type {y}” could be received
4. When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted
5. When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU
6. While moving from lossless to lossy mode while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized
7. SLL configuration is missing in SDK dump
8. If TTL_CMD_COPY is used in Encap direction for a packet with no TTL, then the value passed in the ttl data structure will be used if non-zero (default 255 if zero)
9. PCI calibration changes from a static to a dynamic mechanism
10. Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event
11. SDK returned error when FEC mode is set on twisted pair, when FEC was set to None
- How I did it
Update pointer for the SDK/FW
- How to verify it
Run regression tests
Signed-off-by: dprital <drorp@nvidia.com>
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan arlakshm@microsoft.com
Why I did it
closes#12343
Today in SONiC the notify-keyspace-events is from DbInterface class when application try do any configdb set.
In Chassis the chassis_db may not get any configdb set operations, so there is chance this configuration will never be set.
So the chassis_db updates from one line card will not be propogated to other linecards, which are doing a psubscribe to get these event.
How I did it
update the redis.conf to set notify-keyspace-events AKE so that the notify-keyspace-events are set when the redis instance is started
How to verify it
Test on chassis
Export remote address to environment variable for TACACS authorization.
#### Why I did it
When remote user login, nss-tacplus need user remove address for TACACSS authorization.
#### How I did it
Export remote address to environment variable "SSH_REMOTE_IP"
#### How to verify it
Pass all E2E test.
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
- [ ] 202205
#### Description for the changelog
Export remote address to environment variable for TACACS authorization.
#### Ensure to add label/tag for the feature raised. example - PR#2174 under sonic-utilities repo. where, Generic Config and Update feature has been labelled as GCU.
#### Link to config_db schema for YANG module changes
<!--
Provide a link to config_db schema for the table for which YANG model
is defined
Link should point to correct section on https://github.com/Azure/sonic-buildimage/blob/master/src/sonic-yang-models/doc/Configuration.md
-->
#### A picture of a cute animal (not mandatory but encouraged)
Send remote address in TACACS+ authorization message.
#### Why I did it
TACACS+ authorization message not send remote address to server side.
#### How I did it
Send remote address in TACACS+ authorization message.
#### How to verify it
Pass all E2E test.
Create new test case to validate remote address been send to server side.
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
- [ ] 202205
#### Description for the changelog
Send remote address in TACACS+ authorization message.
#### Ensure to add label/tag for the feature raised. example - [PR#2174](https://github.com/sonic-net/sonic-utilities/pull/2174) where, Generic Config and Update feature has been labelled as GCU.
#### Link to config_db schema for YANG module changes
<!--
Provide a link to config_db schema for the table for which YANG model
is defined
Link should point to correct section on https://github.com/Azure/sonic-buildimage/blob/master/src/sonic-yang-models/doc/Configuration.md
-->
#### A picture of a cute animal (not mandatory but encouraged)
Migrate t0-sonic test jobs to TestbedV2.
Why I did it
Migrate t0-sonic test jobs to TestbedV2.
How I did it
Add two parameters to create testplan.
Modify azure-pipelines.yml to run t0-sonic on tbv2.
Signed-off-by: Yutong Zhang <yutongzhang@microsoft.com>
* [openssh]: Restore behavior of ClientAliveCountMax=0
OpenSSH 8.2 changed the behavior of ClientAliveCountMax=0 such that
setting it to 0 disables connection-killing entirely when the connection
is idle. Revert that change.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
Changes from master branch PR sonic-net/sonic-host-services#13
est_cacl_application fails on VoQ chassis Supervisor with the error:
Failed: Missing expected iptables rules: set(['-A INPUT -s 240.127.1.1/32 -d 240.127.1.1/32 -j ACCEPT', '-A INPUT -s 240.127.1.3/32 -d 240.127.1.1/32 -j ACCEPT', '-A INPUT -s 240.127.1.2/32 -d 240.127.1.1/32 -j ACCEPT'])
This failure is seen because acl rules to allow traffic from fabric namespaces is missing.
This PR is to include fabric namespace docker mgmt ips so that acl rules to allow traffic from namespace is added for fabric namespace as well.
How I did it
Get list of fabric namespaces, use this list to get docker mgmt ip of fabric asic namespace as well.
How to verify it
Verified on voq chassis.
unit-test passes
Include following commit:
936f1b1 Revert "[config reload]: On dual ToR systems, cache ARP and FDB table… (#2461)
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Why I did it
Add the missing debian source bullseye-updates/buster-updates
The build failure as below, it is caused by the docker image debian:bullseye used the version 2.31-13+deb11u5, but the version only available in bullseye-update.
* [202012][Arista] Fix cmdline generation during warm-reboot from 201811/201911 (#11161)
Issue fixed: when performing a warm-reboot or fast-reboot from 201811 or 201911 to 202012 the kernel command line contains duplicate information. This issue is related to a change that was made to make 202012 boot0 file more futureproof.
A cold reboot brings everything back into a clean slate though not always desirable.
Changes done:
Added some logic to properly detect the end of the Aboot cmdline when cmdline-aboot-end delimiter is not set (clean case)
Added some logic to regenerate the Aboot cmdline when cmdline-aboot-end is set but duplicate parameters exists before (dirty case). Reorganized some code to handle duplicate parameter handling in the allowlist.
* Fix cmdline generation due to sonic_fips