sonic-swss commits
5fbd113 [Flex-counters] Fix the delay of flex counters flow to prevent infinite loop (#1899)
dc685b6 [portsorch] Add an extra check before setting oper speed to APPL_DB (#1885)
ceef728 Update port_rates & rif_rates lua scripts to convert poll_interval to MS (#1855)
sonic-utilities commits
3160753 [ci]: Support PR coverage (#1806)
3316fdb fix wrong code indent in sfputil (#1808)
c33e3a8 [config reload] Fix config reload failure due to sonic.target job cancellation (#1814)
4f7e107 [portconfig] Validate duplicate speed value and interface type value (#1745)
59817e2 [warm-reboot] Add new preboot health check: verify database integrity (#1785)
bf2ff3c [portstat, intfstat] added rates and utilization (#1750)
3bf962c [show][platform] Revise chassis info fallback to only fall back on pmon crash (#1751)
*Removed execute permissions from the systemd copp-config.service file.
Without this we will get a warning: "Configuration file /lib/systemd/system/copp-config.service is marked executable. Please remove executable permission bits. Proceeding anyway."
Why I did it
fstrim has dependency on pmon docker.
How I did it
start fstrim timer after sonic.target.
How to verify it
local test and PR test.
Signed-off-by: Ying Xie ying.xie@microsoft.com
To Fix#8697 . The config load_minigraph initializes 'admin_status' to up when platform.json has DPB configs. This doesn't happen when using port_config.ini
The update minigraph has logic to initialize only the ports whose neighbors are defined or those belonging to portchannel
However, a change was introduced to have default admin status to be 'up' in portconfig.py when the minigraph was using platform.json
This will lead to sanity check failure in sonic-mgmt and thus no test cases could be run
* [Nokia ixs7215] Miscellaneous platform API fixes
This commit delivers the following fixes for the Nokia ixs7215 platform
- Fix bug in a fan API error path
- Add support for setting the fan drawer led
- Add support for getting/setting the front panel PSU status led
- Add support for getting the min/max observed temperature value
* [Nokia ixs7215] code review changes: temperature min/max values
- Why I did it
Removed 2x40G for SN3800. This mode is not supported by hardware.
- How I did it
Removing it from hwsku.json and platform.json
- How to verify it
Load it in the device and check supported modes
Why I did it
Fix an issue on the Clearwater2 linecard.
When the linecard is started with a fresh image without configuration, phys would not be initialized.
How I did it
Added default_sku for Clearwater2 which prevents config-setup from failing to create a default config_db.json.
Added some extra logic in the phy-credo-init script to run the phy_config.sh of the hwsku pointed by default_sku if the DEVICE_METADATA.localhost.hwsku information is not populated in CONFIG_DB.
How to verify it
Booting an image with this change and without configuration will lead to the phys being initialized using the phy_config.sh from default_sku.
sonic-swss
73f6f68 [Flex Counters] Delay flex counters even if tables are present in the DB (#1877)
5edb9e5 [buffer orch] Bugfix: Don't query counter SAI_BUFFER_POOL_STAT_XOFF_ROOM_WATERMARK_BYTES on a pool where it is not supported (#1857)
fce0c60 [crm] Fix for Issue Azure/sonic-buildimage#8036 (#1829)
sonic-utilities
2630ac1 [Fast-reboot] Set flex counters delay indicator to prevent flex counters enablement after fast-reboot (#1768)
606f1b1 [portstat pfcstat] Unify the packet number format in the output of portstat and pfcstat in all cases (#1755)
2c6a15e [ecnconfig] Fix exception seen during display and add unit tests (#1784)
9b1995e Fix logic in RIF counters print (#1732)
sonic-swss-comon
3e7b81f Add a new field for FLEX_COUNTER_TABLE to indicate delay for flex counters (#523)
- Why I did it
SN4600 A0 platform was EOL, so there is no need to support it, sensor conf can be removed and we don't need to maintain 2 sensor conf files, only A1 platform is needed.
- How I did it
Remove get_sensors_conf_path which intends to load correct sensor conf for different(A0/A1) platforms.
Remove the sensor conf for A0 platform, rename previous sensor.conf.a1 to sensor.conf
- How to verify it
Run sensor test on the SN4600 platform.
To enable saiserver docker on different platforms, it needs different configuration files. make the saiserver docker mount them in hwsku folder.
Co-authored-by: Ubuntu <richardyu@richardyu-ubuntu-vm0.trsxrdzozv2e1czsze2t05vqzh.ix.internal.cloudapp.net>
#### Why I did it
Reset flex counters delay flag on config DB when enable_counters script is called to allow enablement of flex counters in orchagent.
#### How I did it
Push to config DB 'false' value for delay indication when enable_counters script is called before enabling the counters.
#### How to verify it
Observe counters are created when enable_counters script is called.
#### Why I did it
New PSU could install different type of fan, so fan max/min speed should be read per PSU
#### How I did it
The existing implementation read PSU max/min fan speed from a common file, change it to read from per PSU file
#### How to verify it
Manual test
The Lodoga platform also matched crow which was hardcoding the flash
size to 3700. This change enables autodetect on Clearlake which in turns
allows autodetect for Lodoga.
The threshold was bumped from 3700 to 4000 because size computation can
differ slightly and report slightly above 3700.
Why I did it
The first 4 ports on this dut are breakout ports. They might not always be connected in lab. Mark them as 'RJ45' to skip the SFP check since they are by default disabled.
How to verify it
run platform test_reboot.py
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Lodoga actually has a 8GB storage device.
LodogaSsd variant has a 30GB SSD drive.
However, in boot0 both were mishandled and assigned 4GB for legacy reasons.
Remove the hardcoding of the flash size and let boot0 autodetect the available space.
This commit adds support for changing the default console baud rate configured
within the U-Boot bootloader. That default baud rate is exposed via the value
of the U-Boot 'baudrate' environment variable. This commit removes logic that
hardcoded the console baud rate to 115200 and instead ensures that the U-Boot
'baudrate' variable is always used when constructing the Linux kernel boot
arguments used when booting Sonic.
A change is also made to rc.local to ensure that the specified baud rate is set
correctly in the serial getty service.
Update 202106 release with the Arista drivers from master.
This update is mostly targeted at chassis and is deemed stable.
Most notable chassis improvements:
- fix psu reporting in platform api
- powercycle fabrics on supervisor reboot
- improve card powercycle reliability
- fix led plugin when dealing with `Ethernet-Rec` and `Ethernet-IB`
- fix system-health cli reporting
- unset provisioning mode once the linecard has started
- fix `show version` when running as `admin`
- fix race between loading the eeprom module and sysfs file availablity
- implement `get_all_asics` platform API
88a38f7 Ignore ALREADY_EXIST error in FDB creation (#1815)
b1c23f3 Change rif_rates.lua and port_rates.lua scripts to calculate rates correct (#1848)
Update sonic-utilities submodule with
cbc25d6 [config reload] Call systemctl reset-failed for snmp,telemetry,mgmt-framework services (#1773)
04dcd07 Improve config error handling on version_info (#1760)
e567a60 Load the database global_db. (#1752)
c15fb8f [sfputil] Gracefully handle improper 'specification_compliance' field (#1741)
39350f8 [dhcp_relay] Update CLI reference document and add a new API for ip address type (#1717)
18f13c6 [sonic-package-manager] switch from poetry-semver to semantic_version due to bugs found in poetry-semver (#1710)
b16724a [voq][chassis] VOQ cli show commands implementation (#1689)
9427cd6 [debug dump util] Match Infrastructure (#1666)
d9fb39b [route_check] Filter out VNET routes (#1612)
#### Why I did it
- Adapt config/show CLI commands to support DHCPv6 relay
- Support multiple dhcp servers assignment in one command
- Fix IP validation
- Adapt UT and add new UT cases
#### How I did it
- Modify config/show dhcp relay files
- Modify config/show UT files
#### How to verify it
This PR has a dependency on PR https://github.com/Azure/sonic-utilities/pull/1717
Build an image with the dependent PR and this PR
Use config/show DHCPv6 relay commands.
The unit test failure was due to missing bgp graceful restart select
defer time configuration in voq_chassis.conf. Modified sample output
data file voq_chassis.conf to include this configuration.
Signed-off-by: vedganes <vedavinayagam.ganesan@nokia.com>
*Edited platform.json for 4600 & 4600C
*Edited hwsku.json and port_config.ini files for all the SKU's present under these platforms
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
Why I did it
Pcied running by python 2.
How I did it
dropped python2 support and add python3 support for pcied in file docker-pmon.supervisord.conf.j2
How to verify it
docker exec pmon supervisorctl status
- Why I did it
New release of MFT has the following changelog / RN
Fixed an issue that resulted in getting MVPD read errors from the mlxfwmanager during fast reboot.
Fixed mlxuptime sometimes generating a time less than previous due the wrong frequency calculation
- How I did it
Update makefile pointer to new version.
- How to verify it
Manually tested on all Mellanox platforms.
*To run VNET route consistency check periodically.
*For any failure, the monit will raise alert based on return code.
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
The MSN4410 platform was missing 2x100G and 4x50G supported breakout modes in platform.json
- How I did it
Added the aforementioned breakout modes to platform.json
- How to verify it
Run show interface breakout on a MSN4410 and verify that 2x100G and 4x50G are listed in the supported breakout modes for ports 1-24.
This change introduces 3 columns in the port_config.ini file.
These are coreId, corePortId and numVoq.
The ports for inband and recirc were also renamed properly.
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Enable fib_multipath_use_neigh for v4
https://www.kernel.org/doc/Documentation/networking/ip-sysctl.txt
Why I did:
This is helpful if the neighbor are not directly connected then Kernel forward to unreachable neighbor option. With this option forwarding using neighbor state to be valid.
with state of tdport from previous warm-reboot.
In case LAG was down before reboot, lacp->wr is not cleared.
In lacp_event_watch_port_flush_data we incremented nr_of_tdports and add
tdport to lacp->wr.state. In case lacp->wr.state already had this tdport
we do not set new state for tdport but appened a new item in
lacp->wr.state. In case we preformed warm-reboot and PortChannel member
was down, after reboot PortChannel member became up next warm-reboot
will initialize teamd with PortChannel member in down state.
Fix this issue by calling stop_wr_mode() when LAG was down. This was probably intended but missed.
#### Why I did it
To fix an issue seen in warm-reboot-sad test cases.
#### How I did it
I fixed it in SONiC libteam patch that adds warm-reboot support. Details in commit description.
#### How to verify it
Run warm-reboot-sad test on t0-56 topology.
Fix for sonic-cfggen exception during platform string read during fresh install and start of sonic in multi asic, /var/run/redisX/ is created after database docker is started.
#### Why I did it
Use a predefined variable to get vendor information when the swss docker container is created
#### How I did it
Use `{{ sonic_asic_platform }}` instead of `$SONIC_CFGGEN -y /etc/sonic/sonic_version.yml -v asic_type`
#### How to verify it
Manually test.
#### Why I did it
The values of the syseeprom were not valid
#### How I did it
I took the correct hexdump values from a real switch and created this hex file again
#### How to verify it
decode-syseeprom will display the new values
Master/202012 image size grew quite a bit. 3.7G harddrive can no longer hold one image and safely upgrade to another image. Every bit of harddrive space is precious to save now.
Also sh syntax seemingly changed, [ condition ] && action was a legit syntax in 201911 branch but it is an error when condition not met with 202012 or later images. Change the syntax to if statement to avoid the issue.
Signed-off-by: Ying Xie ying.xie@microsoft.com