Why I did it
Support for SONIC chassis isolation using TSA and un-isolation using TSB from supervisor module
Work item tracking
Microsoft ADO (number only): 17826134
How I did it
When TSA is run on the supervisor, it triggers TSA on each of the linecards using the secure rexec infrastructure introduced in sonic-net/sonic-utilities#2701. User password is requested to allow secure login to linecards through ssh, before execution of TSA/TSB on the linecards
TSA of the chassis withdraws routes from all the external BGP neighbors on each linecard, in order to isolate the entire chassis. No route withdrawal is done from the internal BGP sessions between the linecards to prevent transient drops during internal route deletion. With these changes, complete isolation of a single linecard using TSA will not be possible (a separate CLI/script option will be introduced at a later time to achieve this)
Changes also include no-stats option with TSC for quick retrieval of the current system isolation state
This PR also reverts changes in #11403
How to verify it
These changes have a dependency on sonic-net/sonic-utilities#2701 for testing
Run TSA from supervisor module and ensure transition to Maintenance mode on each linecard
Verify that all routes are withdrawn from eBGP neighbors on all linecards
Run TSB from supervisor module and ensure transition to Normal mode on each linecard
Verify that all routes are re-advertised from eBGP neighbors on all linecards
Run TSC no-stats from supervisor and verify that just the system maintenance state is returned from all linecards
Why I did it
Today at most 128 LAGs are supported. This is not sufficient if there are many LAGs with just few ports.
How I did it
Increase LAG Ids to 1024 for DNX device.
Why I did it
systemd stop event on service with timers can sometime delete the state_db entry for the corresponding service.
Note: This won't be observed on the latest master label since the dependency on timer was removed with the recent config reload enhancement. However, it is better to have the fix since there might be some systemd services added to system health daemon in the future which may contain timers
root@qa-eth-vt01-4-3700c:/home/admin# systemctl stop snmp
root@qa-eth-vt01-4-3700c:/home/admin# show system-health sysready-status
System is not ready - one or more services are not up
Service-Name Service-Status App-Ready-Status Down-Reason
---------------------- ---------------- ------------------ -------------
<Truncated>
ssh OK OK -
swss OK OK -
syncd OK OK -
sysstat OK OK -
teamd OK OK -
telemetry OK OK -
what-just-happened OK OK -
ztp OK OK -
<Truncated>
Expected
Should see a Down entry for SNMP instead of the entry being deleted from the STATE_DB
root@qa-eth-vt01-4-3700c:/home/admin# show system-health sysready-status
System is not ready - one or more services are not up
Service-Name Service-Status App-Ready-Status Down-Reason
---------------------- ---------------- ------------------ -------------
<Truncated>
snmp Down Down Inactive
ssh OK OK -
swss OK OK -
syncd OK OK -
sysstat OK OK -
teamd OK OK -
telemetry OK OK -
what-just-happened OK OK -
ztp OK OK -
<Truncated>
How I did it
Happens because the timer is usually a PartOf service and thus a stop on service is propagated to timer. Fixed the logic to handle this
Apr 18 02:06:47.711252 r-lionfish-16 DEBUG healthd: Main process- received event:snmp.service from source:sysbus time:2023-04-17 23:06:47
Apr 18 02:06:47.711347 r-lionfish-16 INFO healthd: check_unit_status for [ snmp.service ]
Apr 18 02:06:47.722363 r-lionfish-16 INFO healthd: snmp.service service state changed to [inactive/dead]
Apr 18 02:06:47.723230 r-lionfish-16 DEBUG healthd: Main process- received event:snmp.timer from source:sysbus time:2023-04-17 23:06:47
Apr 18 02:06:47.723328 r-lionfish-16 INFO healthd: check_unit_status for [ snmp.timer ]
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
Why I did it
When reboot the chassis by issuing "sudo reboot" on Supervisor card. The internal midplane communication xe0 should be shutdown to avoid double reboot on the linecard.
Added a udev link rule to disable the autoneg on AMD xgbe port Xe0 and Xe1 and make the setting in sync with the peer Broadcom greyhound ports.
How I did it
Modify the Nokia-7250IXRE specific reboot script on the Supervisor card to shutdown the internal interface xe0. Also move reboot linecard code to the top of the script to make sure the notification has been send to Linecard before shutdown the xe0 interface.
Introduced a new rule 80-net-by-driver.link to disable the autoneg on the AMD size. This change requires the latest NDK which contains the change to set the autoneg on the xe0 and xe1 port on the Greyhound.
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
Update sonic-platform submodule for Nokia-7250IXRE Platform. This requires the new NDK 22.9.8 and above
How I did it
Update submodule sonic-platform for Nokia-7250IXRE platform.
c9f316e Disparate process and thread-safe protection for MDIPC transport, and refactored presence logic to better align with SfpStateUpdateTask operation
a3486cc Added _get_module_bulk_info() and cache the info for 5 seconds to optimize the chassisd update.
4b2e729 Fixed the nokia_cmd show qfpga help display
7b87049 Fixed the nokia_cmd show midplane helper dispaly.
83eabea Add "nokia_cmd set ndk-monitor-action" and "nokia_cmd set ndk-log-level" commands
8aad7de Add nokia_cmd show ndk-version
d2c55e3 Modify the psu.py and module.py to optimize the psud running time
Signed-off-by: mlok <marty.lok@nokia.com>
This PR is to add the following
Add a new options "--profile" to the show macsec command, to show all profiles in device
Update the currentl show macsec command, to show profile in each interface o/p. This will tell which macsec profile the interface is attached to.
#### Why I did it
Remove dbus when telemetry does not use it.
##### Work item tracking
- Microsoft ADO **(number only)**: 17852550
#### How I did it
Use INCLUDE_SYSTEM_GNMI to determine if telemetry needs dbus.
#### How to verify it
Build image and check telemetry container.
* Support ACL interface type BmcData in minigraph parser
* Support ACL interface type BmcData in minigraph parser
* add unittest
* Add a global dict for storing the defination of custom acl tables
- Why I did it
Extend the CRM YANG model with DASH attributes.
- How I did it
Add new attributes to the existing CRM YANG model.
Implement tests for DASH CRM attributes.
- How to verify it
Build sonic_yang_models packages. The tests will be run automatically.
Depends on https://github.com/sonic-net/sonic-linux-kernel/pull/315
#### Why I did it
The name SECURE_UPGRADE_DEV_SIGNING_CERT is misleading, this flag is relevant to both to dev and prod signing.
#### How I did it
Rename all mentions of name SECURE_UPGRADE_DEV_SIGNING_CERT to SECURE_UPGRADE_SIGNING_CERT - this is also done with PR in sonic-linux-kernel repository
#### How to verify it
Build SONiC using your own prod script
Why I did it
Import defusedxml packet to fix semgrep error "using defusedxml instead of xml"
How I did it
Add "pip3 install defusedxml" in build_debian.sh
Signed-off-by: pettershao-ragilenetworks <pettershao@ragilenetworks.com>
- Why I did it
We suspect the issue #13791 is caused by redis server being temporarily unavailable during system initialization so we do not use -d in sonic-cfggen, for now, to avoid accessing redis server
- How I did it
Provide a string containing required json data when calling sonic-cfggen
- How to verify it
Manually test it
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Fix per-command authorization failed issue when a command with wildcard match more than hundred files.
#### Why I did it
When user enable TACACS per-command authorization, and run a command with wildcard , if the command match more than hundreds of files, the per-command authorization will failed with following message:
*** authorize failed by TACACS+ with given arguments, not executing
The root cause of this issue is because bash will match files with wildcard and replace with wildcard args with matched files. when there are too many files, TACACS plugin will generate a big authorization request, which will be reject by server side.
##### Work item tracking
- Microsoft ADO **(number only)**: 18074861
#### How I did it
Fix bash patch file, use original user inputs as authorization parameters.
#### How to verify it
Pass all UT.
Create new UT to validate the TACACS authorization request are using original command arguments.
UT PR: https://github.com/sonic-net/sonic-mgmt/pull/8115
#### Which release branch to backport (provide reason below if selected)
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
- [X] 202205
- [X] 202211
#### Tested branch (Please provide the tested image version)
- [x] 202205.258490-412b83d0f
- [x] 202211.71966120-1b971c54b5
#### Description for the changelog
Fix per-command authorization failed issue when a command with wildcard match more than hundred files.
#### Why I did it
sonic-config-engine unit test needs to detect missing yang models.
#### How I did it
Update unit test, return error for missing yang models.
#### How to verify it
Run unit test for sonic-config-engine
#### Why I did it
Yang model for NEIGH table was missing
Fixed https://github.com/sonic-net/sonic-buildimage/issues/13971
#### How I did it
added sonic-neigh.yang model
#### How to verify it
make buildimage
#### Description for the changelog
Adding NEIGH yang model
Closes#14697
Why I did it
When using the dpkg cache feature, debians referenced under SONIC_ONLINE_DEBS always get downloaded, even if the expected debian package already exists under target/. The runs contrary to the design of Makefiles (where presence of the output file indicates it is already built).
This is also counter to the behavior of the SONiC build when dpkg cache is not enabled, causing further confusion.
This behavior also causes problems when doing local development, where we may want to modify the local debian files when evaluating which changes to push to the HTTP repository storing them (Artifactory). With the current behavior, our local changes are always overwritten.
Work item tracking
Microsoft ADO (number only):
How I did it
The SONIC_ONLINE_DEBS rule now skips downloading debians if they already exist under target/.
How to verify it
Populate target/ with locally modified debian packages. Perform the build. Ensure the local modifications remain intact, and are not overwritten.
Signed-off-by: Stepan Blyschak stepanb@nvidia.com
DEPENDS: #12852
Why I did it
To support BGP pending FIB suppression.
How I did it
I backported patches from FRR 8.4 feature that allows communicating ASIC route status back to FRR.
Also, added a new field in DEVICE_METADATA YANG model table. Added UT for YANG model changes.
How to verify it
Run on the switch.
Install python-redis package to docker containers
#### Why I did it
This this bug: https://github.com/sonic-net/sonic-buildimage/issues/14531
The 'flush_unused_database' is part of docker-database, and docker-database does not install python-redis package by itself. it's using redis installed by sonic-py-swsssdk.
So after remove sonic-py-swsssdk from container, this script break.
To this this bug and avoid similer bug happen again, install python-redis to docker containers which removed sonic-py-swsssdk .
#### How I did it
Install python-redis to containers.
#### How to verify it
Pass all UT.
Create new UT to cover this scenario: https://github.com/sonic-net/sonic-mgmt/pull/8032
#### Description for the changelog
Improve sudo cat command for RO user.
Open
[minigraph] add support for changing T1 ports speed from 400G to 100G and vice-versa
#14505
vdahiya12 wants to merge 9 commits into sonic-net:master from vdahiya12:dev/vdahiya/minigraph_parser
Conversation 10
Commits 9
Checks 18
Files changed 5
Conversation
vdahiya12
@vdahiya12 vdahiya12 commented 2 weeks ago •
On SONiC T1 cisco 8101 HwSku, the speed changes are done from 400G to 100G needs to be supported on 400G ports.
To enable this, along with speed change the port lanes need to be changed. This PR has the changes to update the port lanes when such speed change happens.
Basically if Banwidth in minigraph.xml intends to enable a 100G speed on a 400G port, then the appropriate lane change and speed change needs to be invoked in mingraph parser
Example if port_config.ini dicatates the speed to be 400G and minigraph has 100G speed, then this changeneeds to be accommodated
# name lanes alias index speed channel
Ethernet96 1536,1537,1538,1539,1540,1541,1542,1543 etp12 12 400000 0
<DeviceLinkBase>
<ElementType>DeviceInterfaceLink</ElementType>
<EndDevice>ARISTA01T2</EndDevice>
<EndPort>Ethernet1</EndPort>
<StartDevice>Device-8101-01</StartDevice>
<StartPort>etp12</StartPort>
<Bandwidth>100000</Bandwidth>
</DeviceLinkBase>
These platforms today have 400g port with 8 serdes lines, and 100g will operate with 4 serdes lane. When the port speed changes from 400G to 100G the first 4 lanes will be used for 100G port.
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
This is done because when there is a default value, we mount to this path, and this creates this folder on the host.
#### Why I did it
Fix issue that running without overwriting SECURE_UPGRADE_DEV_SIGNING_KEY and SECURE_UPGRADE_DEV_SIGNING_CERT dummy folders are being created on the host.
#### How I did it
Removed the default assignment to SECURE_UPGRADE_DEV_SIGNING_KEY and SECURE_UPGRADE_DEV_SIGNING_CERT
#### How to verify it
Build SONiC using your own prod script
#### Why I did it
Threshold is a new config field passed to telelemetry.go as parameter
#### How I did it
Add check for threshold
#### How to verify it
Modify telemetry.sh, systemctl restart telemetry, telemetry process has threshold of 100