Why I did it
According to ACL-Table-Type-HLD, the value type of MATCHES, ACTIONS and BIND_POINTS should be list instead of string. Opening this PR to update the definition of BMCDATA and BMCDATAV6.
How I did it
Update the definition of BMCDATA and BMCDATAV6 in minigraph-parser.
How to verify it
Verified by UT and build SONiC image.
Added support data for fabric monitoring in CONFIG_DB
The CONFIG_DB now has the FABRIC_MONITOR|FABRIC_MONITOR_DATA table for default value for fabric port monitoring. An example output of getting this table is:
sonic-db-cli CONFIG_DB hgetall "FABRIC_MONITOR|FABRIC_MONITOR_DATA"
{'monErrThreshCrcCells': '1', 'monErrThreshRxCells': '61035156', 'monPollThreshIsolation': '1', 'monPollThreshRecovery': '8'}
The CONFIG_DB now also has a table for each fabric port for its isolate status.
An example output of getting this table is:
sonic-db-cli CONFIG_DB hgetall "FABRIC_PORT|Fabric20"
{'alias': 'Fabric20', 'isolateStatus': 'False', 'lanes': '20'}
Co-authored-by: jfeng-arista <98421150+jfeng-arista@users.noreply.github.com>
Why I did it
Update the definition of acl table type BMCDATA and BMCDATAV6 in minigraph parser.
Work item tracking
Microsoft ADO (number only): 24101023
How I did it
Update the definition of acl table type BMCDATA and BMCDATAV6 in minigraph parser.
How to verify it
Ran unittest to verify this update:
* Re-add 127.0.0.1/8 when bringing down the interfaces
With #5353, 127.0.0.1/16 was added to the lo interface, and then
127.0.0.1/8 was removed. However, when bringing down the lo interface,
like during a config reload, 127.0.0.1/16 gets removed, but 127.0.0.1/8
isn't added back to the interface. This means that there's a period of
time where 127.0.0.1 is not available at all, and services that need to
connect to 127.0.01 (such as for redis DB) will fail.
To fix this, when going down, add 127.0.0.1/8. Add this address before
the existing configuration gets removed, so that 127.0.0.1 is available
at all times.
Note that running `ifdown lo` doesn't actually bring down the loopback
interface; the interface always stays "physically" up.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
* [202205] Update SOC properties for DLR_INIT based pfcwd recovery (#15217)
Why I did it
Update soc properties for certain roles that need to use pfcwd dlr init based recovery mechanism
How to verify it
Updated the templates on a 7050cx3 dual tor and 7260 T1 which satisfies these conditions and validated pfcwd recovery which uses DLR_INIT based mechanism. Also validated that this mechanism is not used on 7050cx3 single tor with the updated templates
Signed-off-by: Neetha John <nejo@microsoft.com>
* AclInterface and Management Interfaces are parsed on finding first valid node for it.
Above logic works for multi-asic scenarios where ACL Interface and Management Interfaces are present in DPG order {Host, Asicx, Asicy} but not when DPG is in {Asicx, Asicy, Host} order.
- Run pre-commit tox profile to trim all trailing blanks
- Use several commits with a per-folder based strategy
to ease their merge
Issue #15114
Signed-off-by: Guillaume Lambert <guillaume.lambert@orange.com>
Why I did it
We need to store information of power shelf in config_db for SONiC MX switch. Current minigraph parser cannot parse rack_mgmt_map field.
Work item tracking
Microsoft ADO (number only): 22179645
How I did it
Add support for parsing rack_mgmt_map.
What I did:
Updated Static Route Attribute in Minigraph. NGS Minigraph has define semantics of static route differently.
See below for differences:-
Microsoft ADO: 17956325
Before
<AssociatedTo>8.0.0.1/32</AssociatedTo>
<Address>192.168.1.2,192.168.2.2</Address>
<AttachTo>PortChannel40,PortChannel50</AttachTo>
Now:
<Address>8.0.0.1</Address>
<AttachTo>PortChannel40,192.168.1.2;PortChannel50,192.168.2.2</AttachTo>
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Update PG headroom settings ports based on port speed/cable length
* Updated XOFF settings to use chip level numbers than core
* Updated PG headroom based on uplink/downlink side
* fix for sonic-config-gen tests
* More fixes for unit test cases
* more test fixes
* Merged multiple functions into one
Following changes are done:
Added Support where if asic configuration is not present in minigraph sonic-cfggen do not error out but instead process it gracefully.
Use Case: In Supervisor we have number of asic are define as max possible but in minigraph configuration of only valid/available asics only are present. Without this change load_minigraph fails.
Microsoft ADO: 17956325
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Why I did it
To support BGPMon sessions from each T2 linecard ASIC
Work item tracking
Microsoft ADO (number only): 17873174
How I did it
Added change in BGPMon configuration to use Loopback4096 as source interface, since this has a unique IP per ASIC.
How to verify it
Tested by manually setting up BGPMon session on T2 LC and verified that Loopback4096 could be used as source
There are chassis-packet and Single asic platforms which support this 400G to 100G/40G speed change via config.
Enabling this feature for all platforms which can support this. Keeping it enabled for all does not affect the platforms
which do not support this feature yet.
Signed-off-by: anamehra anamehra@cisco.com
Why I did it
Update ECN settings for T2 chassis
How I did it
Updated qos config file to load these settings during switch bootup
How to verify it
Verified on line card on T2 chassis
* Support ACL interface type BmcData in minigraph parser
* Support ACL interface type BmcData in minigraph parser
* add unittest
* Add a global dict for storing the defination of custom acl tables
#### Why I did it
sonic-config-engine unit test needs to detect missing yang models.
#### How I did it
Update unit test, return error for missing yang models.
#### How to verify it
Run unit test for sonic-config-engine
Signed-off-by: Stepan Blyschak stepanb@nvidia.com
DEPENDS: #12852
Why I did it
To support BGP pending FIB suppression.
How I did it
I backported patches from FRR 8.4 feature that allows communicating ASIC route status back to FRR.
Also, added a new field in DEVICE_METADATA YANG model table. Added UT for YANG model changes.
How to verify it
Run on the switch.
Open
[minigraph] add support for changing T1 ports speed from 400G to 100G and vice-versa
#14505
vdahiya12 wants to merge 9 commits into sonic-net:master from vdahiya12:dev/vdahiya/minigraph_parser
Conversation 10
Commits 9
Checks 18
Files changed 5
Conversation
vdahiya12
@vdahiya12 vdahiya12 commented 2 weeks ago •
On SONiC T1 cisco 8101 HwSku, the speed changes are done from 400G to 100G needs to be supported on 400G ports.
To enable this, along with speed change the port lanes need to be changed. This PR has the changes to update the port lanes when such speed change happens.
Basically if Banwidth in minigraph.xml intends to enable a 100G speed on a 400G port, then the appropriate lane change and speed change needs to be invoked in mingraph parser
Example if port_config.ini dicatates the speed to be 400G and minigraph has 100G speed, then this changeneeds to be accommodated
# name lanes alias index speed channel
Ethernet96 1536,1537,1538,1539,1540,1541,1542,1543 etp12 12 400000 0
<DeviceLinkBase>
<ElementType>DeviceInterfaceLink</ElementType>
<EndDevice>ARISTA01T2</EndDevice>
<EndPort>Ethernet1</EndPort>
<StartDevice>Device-8101-01</StartDevice>
<StartPort>etp12</StartPort>
<Bandwidth>100000</Bandwidth>
</DeviceLinkBase>
These platforms today have 400g port with 8 serdes lines, and 100g will operate with 4 serdes lane. When the port speed changes from 400G to 100G the first 4 lanes will be used for 100G port.
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
Why I did it
For better accounting purposes, updating the ingress lossy traffic profile to use static threshold. This change is only intended for Th devices using RDMA-CENTRIC profiles
How I did it
Update the buffer templates for Th devices in RDMA-CENTRIC folder to use the correct threshold
How to verify it
Verified the changes manually on a Th device.
Existing unit tests render Th template from the RDMA-CENTRIC folder. Updated the expected output to use the correct threshold
Why I did it
SONiC currently does not identify 'EdgeZoneAggregator' neighbor. As a result, the buffer profile attached to those interfaces uses the default cable length which could cause ingress packet drops due to insufficient headroom. Hence, there is a need to update the buffer templates to identify such neighbors and assign the same cable length as used by the T1.
How I did it
Modified the buffer template to identify EdgeZoneAggregator as a neighbor device type and assign it the same cable length as a T1/leaf router.
How to verify it
Unit tests pass, and manually checked on a 7260 to see the changes take effect.
Signed-off-by: dojha <devojha@microsoft.com>
Why I did it
After the renaming of the asic_port_name in port_config.ini file (PR: #13053 ), the asic_ifname in port_config.ini is changed from '-ASIC<asic_id>' to just port. Example: 'Eth0-ASIC0' to 'Eth0'.
However, with this change a config_db generated via config load_minigraph would cause the EVERFLOW and EVERFLOWV6 tables under ACL_TABLE to not have any of non-LAG front panel interfaces. This was causing the EVERFLOW suite to fail.
How I did it
In parse_asic_external_neigbhors in minigraph.py there was a check that the asic_name.lower() (like asic0) is present in the port_alias_asic_map. However with -ASIC removed from the asic_ifname, the port_alias_asic_map would not have the asic_name and thus any non-LAG neighbor would not be included.
Fix was the ignore the asic name change as the port_alias_asic_map is already only looking for ports in just the same asic as asic_name.
How to verify it
Execute "config load_minigraph" with the mingraph which is generated by sonic-mgmt gen-minigraph script. And confirm ono-lag interface are present in the Everfloe table in the config_dbs.
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
SONiC related packages shouldn't be intalled from Pypi.
It is security compliance requirement.
How I did it
Check SONiC related packages when using setup.py.
How to verify it
On SONiC VoQ chassis, the speed changes are done from 400G to 100G needs to be supported on 400G linecards.
To enable this, along with speed change the port lanes need to be changed. This PR has the changes to update the port lanes when such speed change happens.
This PR is intended only for VoQ chassis linecards. These platforms today have 400g port with 8 serdes lines, and 100g will operate with 4 serdes lane. When the port speed changes from 400G to 100G the first 4 lanes will be used for 100G port.
Platforms which support 2x50g PAM4 or support 100G PAM4 serdes or other combinations are not handled in the PR.
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
Fixes#11873.
#### Why I did it
When loading from minigraph, for port channels, don't create the members@ array in config_db in the PORTCHANNEL table. This is no longer needed or used.
In addition, when adding a port channel member from the CLI, that member doesn't get added into the members@ array, resulting in a bit of inconsistency. This gets rid of that inconsistency.
Signed-off-by: Zhixin Zhu zhixzhu@cisco.com
Why I did it
backplane ports cable length need to be specified.
How I did it
separated handling for the specific port name.
- Why I did it
Support DSCP remapping in dual ToR topo on T0 switch for SKU Mellanox-SN4600c-C64, Mellanox-SN4600c-D48C40, Mellanox-SN2700, Mellanox-SN2700-D48C8.
- How I did it
Regarding buffer settings, originally, there are two lossless PGs and queues 3, 4. In dual ToR scenario, the lossless traffic from the leaf switch to the uplink of the ToR switch can be bounced back.
To avoid PFC deadlock, we need to map the bounce-back lossless traffic to different PGs and queues. Therefore, 2 additional lossless PGs and queues are allocated on uplink ports on ToR switches.
On uplink ports, map DSCP 2/6 to TC 2/6 respectively
On downlink ports, both DSCP 2/6 are still mapped to TC 1
Buffer adjusted according to the ports information:
Mellanox-SN4600c-C64:
56 downlinks 50G + 8 uplinks 100G
Mellanox-SN4600c-D48C40, Mellanox-SN2700, Mellanox-SN2700-D48C8:
24 downlinks 50G + 8 uplinks 100G
- How to verify it
Unit test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
dplane_fpm_nl is a new FPM implementation in FRR. The old plugin fpm will not have any new features implemented. Usage of the new plugin gives us ability to use BGP suppression feature and next hop groups in the future.
How I did it
Switch to dplane_fpm_nl zebra plugin from old fpm plugin which is not supported anymore
Remove stale patches for old fpm plugin and add similar patches for dplane_fpm_nl
How to verify it
Build and run on the switch.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Add YANG model for SYSTEM_PORT.
Resolves https://github.com/sonic-net/sonic-buildimage/issues/12458
#### Why I did it
YANG model for SYSTEM_PORT in CONFIG_DB was missing.
#### How I did it
Added new YANG model and associated unit tests.
#### How to verify it
Passing unit tests
Why I did it
This PR is an enhancement of PR #13105
Because the input string of AttachTo for ACL table can appear in both port name group and port alias group, I added a logic to determine whether the string should be port name or port alias
If all the input strings belong to port name group, then we treat all of them as port name
If all the input strings belong to port alias, then we treat all of them as port alias
If all the input string belongs to both port alias group and port name group, we prefer port alias. The behavior is as before.
How I did it
Walk through all port names/alias in the input to make a decision.
How to verify it
Verified by adding UT.
Why I did it
This PR is to update minigraph.py to support both port alias and port name as input of AttachTo attribute of ACL table.
Before this change, only port alias is supported.
How I did it
Add a global variable to store port names
Search both port names and port alias wheh parsing the value of AttachTo.
How to verify it
Verified by a new unit test case test_minigraph_acl_attach_to_ports
Verified by copying the new minigraph.py to a testbed and run conflg load_minigraph.
Why I did it
In the voq chassis the buffer_queue configuration needs to be applied on system_port instead of the sonic port.
This PR has the change to do this.
How I did it
Modify buffer_config.j2 to generate buffer_queue configuration on system_ports if the device is Voq Chassis
How to verify it
Verify the buffer_queue configuration is generated properly using sonic-cfggen
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
Why I did it
To ensure, that after a BGP startup, dualtor T0 receives BGP updates before sending out BGP updates.
Please refer to sonic-net/SONiC#1161 for more details.
How I did it
add coalesce-time 10000 to the frr bgp startup config.
Signed-off-by: Longxiang Lyu <lolv@microsoft.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
ECN parameters need to be updated for storage backend
How I did it
Included the check for storage backend devices to update qos configs
How to verify it
Verified that the new ecn settings are applied on storage backend device.
Verified that the old ecn settings are applied for storage frontend, non storage frontend/backend devices
Why I did it
The PR is to apply separated DSCP_TO_TC_MAP and TC_TO_QUEUE_MAP to uplink ports on dualtor.
The traffic with DSCP 2 and DSCP 6 from T1 is treated as lossless traffic.
DSCP TC Queue
2 2 2
6 6 6
Traffic with DSCP 2 or DSCP 6 from downlink is still treated as lossy traffic as before.
How I did it
Define DSCP_TO_TC_MAP|AZURE_UPLINK and TC_TO_QUEUE_MAP|AZURE_UPLINK.
How to verify it
Verified by UT
Verified by coping the new template to a testbed, and rendering a config_db.json
This PR is part of the following HLD:
Persistent loglevel HLD: sonic-net/SONiC#1041
- Why I did it
After the Logger tables moved from the LOGLEVEL_DB to the CONFIG_DB and the jinja2_cache was deleted the LOGLEVEL_DB is not in use.
- How I did it
Removed the LOGLEVEL_DB from the SONiC code
- How to verify it
All tests were passed
Signed-off-by: maipbui <maibui@microsoft.com>
#### Why I did it
`subprocess` is used with `shell=True`, which is very dangerous for shell injection.
`os` - not secure against maliciously constructed input and dangerous if used to evaluate dynamic content
`yaml.load` can create arbitrary Python objects
#### How I did it
Replace `os` by `subprocess`, remove `shell=True`
Use `yaml.safe_load()`
#### How to verify it
Pass UT