[sonic-cfggen]: Remove deprecated platform folder and update related files (#429)

Signed-off-by: Shuotian Cheng <shuche@microsoft.com>
This commit is contained in:
Shuotian Cheng 2017-03-23 16:30:37 -07:00 committed by GitHub
parent 5150ed55c7
commit b010e23725
15 changed files with 0 additions and 549 deletions

View File

@ -1,2 +1 @@
recursive-include platform *.json *.ini *.conf
recursive-include tests *.j2 *.yml *.xml

View File

@ -1,33 +0,0 @@
# name lanes
Ethernet0 0,1,2,3
Ethernet4 4,5,6,7
Ethernet8 8,9,10,11
Ethernet12 12,13,14,15
Ethernet16 16,17,18,19
Ethernet20 20,21,22,23
Ethernet24 24,25,26,27
Ethernet28 28,29,30,31
Ethernet32 32,33,34,35
Ethernet36 36,37,38,39
Ethernet40 40,41,42,43
Ethernet44 44,45,46,47
Ethernet48 48,49,50,51
Ethernet52 52,53,54,55
Ethernet56 56,57,58,59
Ethernet60 60,61,62,63
Ethernet64 64,65,66,67
Ethernet68 68,69,70,71
Ethernet72 72,73,74,75
Ethernet76 76,77,78,79
Ethernet80 80,81,82,83
Ethernet84 84,85,86,87
Ethernet88 88,89,90,91
Ethernet92 92,93,94,95
Ethernet96 96,97,98,99
Ethernet100 100,101,102,103
Ethernet104 104,105,106,107
Ethernet108 108,109,110,111
Ethernet112 112,113,114,115
Ethernet116 116,117,118,119
Ethernet120 120,121,122,123
Ethernet124 124,125,126,127

View File

@ -1,21 +0,0 @@
bus "i2c-7" "i2c-1-mux (chan_id 5)"
chip "lm75-i2c-7-4a"
label temp1 "Ambient Port Temp"
bus "i2c-5" "i2c-1-mux (chan_id 3)"
chip "ucd9200-i2c-5-27"
label in1 "UCD1 vin"
label in2 "ASIC 3.3 vout"
label in3 "ASIC 1.2 vout"
label temp1 "UCD1 Temp"
label temp2 "UCD1 Temp2"
chip "ucd9200-i2c-5-41"
label in1 "UCD2 vin"
label in2 "ASIC Vcore vout"
label temp1 "UCD2 Temp1"
label temp2 "UCD2 Temp2"
bus "i2c-17" "i2c-1-mux (chan_id 7)"
chip "lm75-i2c-17-49"
label temp1 "Ambient Board Temp"

View File

@ -1,33 +0,0 @@
# name lanes
Ethernet0 16,17,18,19
Ethernet4 20,21,22,23
Ethernet8 24,25,26,27
Ethernet12 28,29,30,31
Ethernet16 32,33,34,35
Ethernet20 36,37,38,39
Ethernet24 40,41,42,43
Ethernet28 44,45,46,47
Ethernet32 0,1,2,3
Ethernet36 4,5,6,7
Ethernet40 8,9,10,11
Ethernet44 12,13,14,15
Ethernet48 48,49,50,51
Ethernet52 52,53,54,55
Ethernet56 56,57,58,59
Ethernet60 60,61,62,63
Ethernet64 127,126,125,124
Ethernet68 123,122,121,120
Ethernet72 115,114,113,112
Ethernet76 119,118,117,116
Ethernet80 79,78,77,76
Ethernet84 75,74,73,72
Ethernet88 64,65,66,67
Ethernet92 71,70,68,69
Ethernet96 111,110,109,108
Ethernet100 107,106,105,104
Ethernet104 103,102,101,100
Ethernet108 99,98,97,96
Ethernet112 95,94,93,92
Ethernet116 91,90,89,88
Ethernet120 87,86,85,84
Ethernet124 83,82,81,80

View File

@ -1,33 +0,0 @@
# name lanes alias
Ethernet0 125,126,127,128 Ethernet1/1
Ethernet4 121,122,123,124 Ethernet2/1
Ethernet8 13,14,15,16 Ethernet3/1
Ethernet12 9,10,11,12 Ethernet4/1
Ethernet16 17,18,19,20 Ethernet5/1
Ethernet20 21,22,23,24 Ethernet6/1
Ethernet24 25,26,27,28 Ethernet7/1
Ethernet28 29,30,31,32 Ethernet8/1
Ethernet32 37,38,39,40 Ethernet9/1
Ethernet36 33,34,35,36 Ethernet10/1
Ethernet40 45,46,47,48 Ethernet11/1
Ethernet44 41,42,43,44 Ethernet12/1
Ethernet48 53,54,55,56 Ethernet13/1
Ethernet52 49,50,51,52 Ethernet14/1
Ethernet56 69,70,71,72 Ethernet15/1
Ethernet60 65,66,67,68 Ethernet16/1
Ethernet64 77,78,79,80 Ethernet17/1
Ethernet68 73,74,75,76 Ethernet18/1
Ethernet72 93,94,95,96 Ethernet19/1
Ethernet76 89,90,91,92 Ethernet20/1
Ethernet80 101,102,103,104 Ethernet21/1
Ethernet84 97,98,99,100 Ethernet22/1
Ethernet88 109,110,111,112 Ethernet23/1
Ethernet92 105,106,107,108 Ethernet24/1
Ethernet96 61,62,63,64 Ethernet25
Ethernet100 57,58,59,60 Ethernet26
Ethernet104 81,82,83,84 Ethernet27
Ethernet108 85,86,87,88 Ethernet28
Ethernet112 117,118,119,120 Ethernet29
Ethernet116 113,114,115,116 Ethernet30
Ethernet120 5,6,7,8 Ethernet31
Ethernet124 1,2,3,4 Ethernet32

View File

@ -1,79 +0,0 @@
# libsensors configuration file
# ----------------------------------------------
#
bus "i2c-2" "SCD SMBus master 0 bus 0"
bus "i2c-3" "SCD SMBus master 0 bus 1"
bus "i2c-5" "SCD SMBus master 0 bus 3"
bus "i2c-6" "SCD SMBus master 0 bus 4"
bus "i2c-7" "SCD SMBus master 0 bus 5"
chip "k10temp-pci-00c3"
label temp1 "Cpu temp sensor"
chip "lm73-i2c-3-48"
label temp1 "Rear Temp Sensor"
set temp1_max 65
#set temp1_max_alarm 75 # read-only
chip "lm86-i2c-2-4c"
label temp1 "Board Temp Sensor"
set temp1_max 65
set temp1_crit 75
label temp2 "Front-panel Temp Sensor"
set temp2_max 65
set temp2_crit 75
chip "pmbus-i2c-3-4e"
label temp1 "Power Controller Sensor 1"
set temp1_max 60
set temp1_crit 70
label temp2 "Power Controller Sensor 2"
set temp2_max 60
set temp2_crit 70
ignore curr1
chip "pmbus-i2c-5-58"
label temp1 "Power Supply 1 Sensor 1"
set temp1_max 60
set temp1_crit 70
label temp2 "Power Supply 1 Sensor 2"
set temp2_max 60
set temp2_crit 70
ignore temp3
set in1_max 250
set in1_crit 255
set power1_max 525
set power2_max 460
set power2_crit 462
set curr1_max 5.28
set curr1_crit 5.30
set curr2_max 36
set curr2_crit 37
chip "pmbus-i2c-6-58"
label temp1 "Power Supply 2 Sensor 1"
set temp1_max 60
set temp1_crit 70
label temp2 "Power Supply 2 Sensor 2"
set temp2_max 60
set temp2_crit 70
ignore temp3
set in1_max 250
set in1_crit 255
set power1_max 525
set power2_max 460
set power2_crit 462
set curr1_max 5.28
set curr1_crit 5.30
set curr2_max 36
set curr2_crit 37

View File

@ -1,33 +0,0 @@
# name lanes alias
Ethernet0 33,34,35,36 Ethernet1/1
Ethernet4 37,38,39,40 Ethernet2/1
Ethernet8 41,42,43,44 Ethernet3/1
Ethernet12 45,46,47,48 Ethernet4/1
Ethernet16 49,50,51,52 Ethernet5/1
Ethernet20 53,54,55,56 Ethernet6/1
Ethernet24 57,58,59,60 Ethernet7/1
Ethernet28 61,62,63,64 Ethernet8/1
Ethernet32 65,66,67,68 Ethernet9/1
Ethernet36 69,70,71,72 Ethernet10/1
Ethernet40 73,74,75,76 Ethernet11/1
Ethernet44 77,78,79,80 Ethernet12/1
Ethernet48 81,82,83,84 Ethernet13/1
Ethernet52 85,86,87,88 Ethernet14/1
Ethernet56 89,90,91,92 Ethernet15/1
Ethernet60 93,94,95,96 Ethernet16/1
Ethernet64 97,98,99,100 Ethernet17/1
Ethernet68 101,102,103,104 Ethernet18/1
Ethernet72 105,106,107,108 Ethernet19/1
Ethernet76 109,110,111,112 Ethernet20/1
Ethernet80 113,114,115,116 Ethernet21/1
Ethernet84 117,118,119,120 Ethernet22/1
Ethernet88 121,122,123,124 Ethernet23/1
Ethernet92 125,126,127,128 Ethernet24/1
Ethernet96 1,2,3,4 Ethernet25/1
Ethernet100 5,6,7,8 Ethernet26/1
Ethernet104 9,10,11,12 Ethernet27/1
Ethernet108 13,14,15,16 Ethernet28/1
Ethernet112 17,18,19,20 Ethernet29/1
Ethernet116 21,22,23,24 Ethernet30/1
Ethernet120 25,26,27,28 Ethernet31/1
Ethernet124 29,30,31,32 Ethernet32/1

View File

@ -1,47 +0,0 @@
# libsensors configuration file for DCS-7060CX-32S
# ------------------------------------------------
#
bus "i2c-2" "SCD SMBus master 0 bus 0"
bus "i2c-3" "SCD SMBus master 0 bus 1"
bus "i2c-5" "SCD SMBus master 0 bus 3"
bus "i2c-6" "SCD SMBus master 0 bus 4"
bus "i2c-7" "SCD SMBus master 0 bus 5"
chip "k10temp-pci-00c3"
label temp1 "Cpu temp sensor"
# missing support for
# chip "max6697-i2c-2-1a"
# board sensor 65 75
# (1) switch chip left sensor 95 105
# (5) switch chip right sensor 95 105
# (6) front panel temp sensor 65 75
chip "max6658-i2c-3-4c"
label temp1 "Cpu board temp sensor"
set temp1_max 75
set temp1_crit 80
label temp2 "Back panel temp sensor"
set temp2_max 75
set temp2_crit 80
chip "pmbus-i2c-3-4e"
label temp1 "Power controller 1 sensor 1"
label temp2 "Power controller 1 sensor 2"
chip "pmbus-i2c-7-4e"
label temp1 "Power controller 2 sensor 1"
label temp2 "Power controller 2 sensor 2"
chip "pmbus-i2c-6-58"
label temp1 "Power supply 1 hotspot sensor"
label temp2 "Power supply 1 inlet temp sensor"
label temp3 "Power supply 1 sensor"
chip "pmbus-i2c-5-58"
label temp1 "Power supply 2 hotspot sensor"
label temp2 "Power supply 2 inlet temp sensor"
label temp3 "Power supply 2 sensor"

View File

@ -1,33 +0,0 @@
# name lanes alias
Ethernet0 29,30,31,32 fortyGigE0/0
Ethernet4 25,26,27,28 fortyGigE0/4
Ethernet8 37,38,39,40 fortyGigE0/8
Ethernet12 33,34,35,36 fortyGigE0/12
Ethernet16 41,42,43,44 fortyGigE0/16
Ethernet20 45,46,47,48 fortyGigE0/20
Ethernet24 5,6,7,8 fortyGigE0/24
Ethernet28 1,2,3,4 fortyGigE0/28
Ethernet32 9,10,11,12 fortyGigE0/32
Ethernet36 13,14,15,16 fortyGigE0/36
Ethernet40 21,22,23,24 fortyGigE0/40
Ethernet44 17,18,19,20 fortyGigE0/44
Ethernet48 49,50,51,52 fortyGigE0/48
Ethernet52 53,54,55,56 fortyGigE0/52
Ethernet56 61,62,63,64 fortyGigE0/56
Ethernet60 57,58,59,60 fortyGigE0/60
Ethernet64 65,66,67,68 fortyGigE0/64
Ethernet68 69,70,71,72 fortyGigE0/68
Ethernet72 77,78,79,80 fortyGigE0/72
Ethernet76 73,74,75,76 fortyGigE0/76
Ethernet80 105,106,107,108 fortyGigE0/80
Ethernet84 109,110,111,112 fortyGigE0/84
Ethernet88 117,118,119,120 fortyGigE0/88
Ethernet92 113,114,115,116 fortyGigE0/92
Ethernet96 121,122,123,124 fortyGigE0/96
Ethernet100 125,126,127,128 fortyGigE0/100
Ethernet104 85,86,87,88 fortyGigE0/104
Ethernet108 81,82,83,84 fortyGigE0/108
Ethernet112 89,90,91,92 fortyGigE0/112
Ethernet116 93,94,95,96 fortyGigE0/116
Ethernet120 97,98,99,100 fortyGigE0/120
Ethernet124 101,102,103,104 fortyGigE0/124

View File

@ -1,57 +0,0 @@
# libsensors configuration file
# --------------------------------------------------
#
# tmp75-i2c-11-4c has sensors close to Networking ASIC.
# tmp75-i2c-11-4d has sensors close to NIC.
# tmp75-i2c-11-4e is an ambient temperature sensor.
chip "tmp75-*"
set temp1_max 50
set temp1_max_hyst 25
# emc1403-i2c-10-4d has following temperature sensors:
# temp1: CPU0 external Temp Sensor
# temp2: CPU1 external Temp Sensor
# temp3: CPU Internal DTS (Internal die, max of all die readings)
chip "emc1403-*"
set temp1_crit 85
set temp1_max 50
set temp2_crit 85
set temp2_max 50
set temp3_crit 85
set temp3_max 50
chip "max6620-i2c-*-2a"
ignore fan3
ignore fan4
chip "w83627dhg-*"
label in0 "VCore 1"
label in1 "VCore 2"
set in0_min 0
set in0_max 1.74
set in1_min 0
set in1_max 1.74
ignore fan1
ignore fan2
ignore fan3
ignore fan4
ignore fan5
ignore in4
ignore in5
ignore in6
ignore temp1
ignore temp2
ignore temp3
ignore cpu0_vid
ignore intrusion0
chip "jc42-*"
set temp1_max 50
set temp1_crit 85
chip "dni_dps460-*"
set temp1_max 50
set temp2_max 50

View File

@ -1,65 +0,0 @@
# name lanes alias
Ethernet0 101,102 fortyGigE1/1/1
Ethernet1 103,104 fortyGigE1/1/2
Ethernet2 97,98 fortyGigE1/1/3
Ethernet3 99,100 fortyGigE1/1/4
Ethernet4 69,70 fortyGigE1/1/5
Ethernet5 71,72 fortyGigE1/1/6
Ethernet6 65,66 fortyGigE1/1/7
Ethernet7 67,68 fortyGigE1/1/8
Ethernet8 53,54 fortyGigE1/1/9
Ethernet9 55,56 fortyGigE1/1/10
Ethernet10 49,50 fortyGigE1/1/11
Ethernet11 51,52 fortyGigE1/1/12
Ethernet12 21,22 fortyGigE1/1/13
Ethernet13 23,24 fortyGigE1/1/14
Ethernet14 17,18 fortyGigE1/1/15
Ethernet15 19,20 fortyGigE1/1/16
Ethernet16 25,26 fortyGigE1/2/1
Ethernet17 27,28 fortyGigE1/2/2
Ethernet18 29,30 fortyGigE1/2/3
Ethernet19 31,32 fortyGigE1/2/4
Ethernet20 57,58 fortyGigE1/2/5
Ethernet21 59,60 fortyGigE1/2/6
Ethernet22 61,62 fortyGigE1/2/7
Ethernet23 63,64 fortyGigE1/2/8
Ethernet24 73,74 fortyGigE1/2/9
Ethernet25 75,76 fortyGigE1/2/10
Ethernet26 77,78 fortyGigE1/2/11
Ethernet27 79,80 fortyGigE1/2/12
Ethernet28 105,106 fortyGigE1/2/13
Ethernet29 107,108 fortyGigE1/2/14
Ethernet30 109,110 fortyGigE1/2/15
Ethernet31 111,112 fortyGigE1/2/16
Ethernet32 13,14 fortyGigE1/3/1
Ethernet33 15,16 fortyGigE1/3/2
Ethernet34 9,10 fortyGigE1/3/3
Ethernet35 11,12 fortyGigE1/3/4
Ethernet36 125,126 fortyGigE1/3/5
Ethernet37 127,128 fortyGigE1/3/6
Ethernet38 121,122 fortyGigE1/3/7
Ethernet39 123,124 fortyGigE1/3/8
Ethernet40 93,94 fortyGigE1/3/9
Ethernet41 95,96 fortyGigE1/3/10
Ethernet42 89,90 fortyGigE1/3/11
Ethernet43 91,92 fortyGigE1/3/12
Ethernet44 45,46 fortyGigE1/3/13
Ethernet45 47,48 fortyGigE1/3/14
Ethernet46 41,42 fortyGigE1/3/15
Ethernet47 43,44 fortyGigE1/3/16
Ethernet48 113,114 fortyGigE1/4/1
Ethernet49 115,116 fortyGigE1/4/2
Ethernet50 117,118 fortyGigE1/4/3
Ethernet51 119,120 fortyGigE1/4/4
Ethernet52 1,2 fortyGigE1/4/5
Ethernet53 3,4 fortyGigE1/4/6
Ethernet54 5,6 fortyGigE1/4/7
Ethernet55 7,8 fortyGigE1/4/8
Ethernet56 33,34 fortyGigE1/4/9
Ethernet57 35,36 fortyGigE1/4/10
Ethernet58 37,38 fortyGigE1/4/11
Ethernet59 39,40 fortyGigE1/4/12
Ethernet60 81,82 fortyGigE1/4/13
Ethernet61 83,84 fortyGigE1/4/14
Ethernet62 85,86 fortyGigE1/4/15
Ethernet63 87,88 fortyGigE1/4/16

View File

@ -1,33 +0,0 @@
# name lanes alias
Ethernet0 49,50,51,52 hundredGigE1/1
Ethernet4 53,54,55,56 hundredGigE1/2
Ethernet8 57,58,59,60 hundredGigE1/3
Ethernet12 61,62,63,64 hundredGigE1/4
Ethernet16 65,66,67,68 hundredGigE1/5
Ethernet20 69,70,71,72 hundredGigE1/6
Ethernet24 73,74,75,76 hundredGigE1/7
Ethernet28 77,78,79,80 hundredGigE1/8
Ethernet32 37,38,39,40 hundredGigE1/9
Ethernet36 33,34,35,36 hundredGigE1/10
Ethernet40 45,46,47,48 hundredGigE1/11
Ethernet44 41,42,43,44 hundredGigE1/12
Ethernet48 81,82,83,84 hundredGigE1/13
Ethernet52 85,86,87,88 hundredGigE1/14
Ethernet56 89,90,91,92 hundredGigE1/15
Ethernet60 93,94,95,96 hundredGigE1/16
Ethernet64 97,98,99,100 hundredGigE1/17
Ethernet68 101,102,103,104 hundredGigE1/18
Ethernet72 105,106,107,108 hundredGigE1/19
Ethernet76 109,110,111,112 hundredGigE1/20
Ethernet80 21,22,23,24 hundredGigE1/21
Ethernet84 17,18,19,20 hundredGigE1/22
Ethernet88 29,30,31,32 hundredGigE1/23
Ethernet92 25,26,27,28 hundredGigE1/24
Ethernet96 117,118,119,120 hundredGigE1/25
Ethernet100 113,114,115,116 hundredGigE1/26
Ethernet104 125,126,127,128 hundredGigE1/27
Ethernet108 121,122,123,124 hundredGigE1/28
Ethernet112 5,6,7,8 hundredGigE1/29
Ethernet116 1,2,3,4 hundredGigE1/30
Ethernet120 13,14,15,16 hundredGigE1/31
Ethernet124 9,10,11,12 hundredGigE1/32

View File

@ -1,33 +0,0 @@
# name lanes alias
Ethernet0 5,6,7,8 Ethernet0
Ethernet4 1,2,3,4 Ethernet4
Ethernet8 13,14,15,16 Ethernet8
Ethernet12 9,10,11,12 Ethernet12
Ethernet16 21,22,23,24 Ethernet16
Ethernet20 17,18,19,20 Ethernet20
Ethernet24 29,30,31,32 Ethernet24
Ethernet28 25,26,27,28 Ethernet28
Ethernet32 37,38,39,40 Ethernet32
Ethernet36 33,34,35,36 Ethernet36
Ethernet40 45,46,47,48 Ethernet40
Ethernet44 41,42,43,44 Ethernet44
Ethernet48 53,54,55,56 Ethernet48
Ethernet52 49,50,51,52 Ethernet52
Ethernet56 61,62,63,64 Ethernet56
Ethernet60 57,58,59,60 Ethernet60
Ethernet64 69,70,71,72 Ethernet64
Ethernet68 65,66,67,68 Ethernet68
Ethernet72 77,78,79,80 Ethernet72
Ethernet76 73,74,75,76 Ethernet76
Ethernet80 85,86,87,88 Ethernet80
Ethernet84 81,82,83,84 Ethernet84
Ethernet88 93,94,95,96 Ethernet88
Ethernet92 89,90,91,92 Ethernet92
Ethernet96 101,102,103,104 Ethernet96
Ethernet100 97,98,99,100 Ethernet100
Ethernet104 109,110,111,112 Ethernet104
Ethernet108 105,106,107,108 Ethernet108
Ethernet112 117,118,119,120 Ethernet112
Ethernet116 113,114,115,116 Ethernet116
Ethernet120 125,126,127,128 Ethernet120
Ethernet124 121,122,123,124 Ethernet124

View File

@ -1,35 +0,0 @@
# libsensors configuration file
chip "i350bb-*"
ignore loc1
chip "jc42-*"
label temp1 "DIMM Temp"
set temp1_max 50
set temp1_crit 85
chip "w83795adg-*"
label in0 "1.0V"
label in1 "1.0V_ROV"
label in2 "1.25V"
label in3 "1.8V"
ignore in4
ignore in5
ignore in6
ignore in7
label in12 "+3.3V"
ignore in14
ignore in15
ignore in16
label fan1 "FANTRAY 1-A"
label fan2 "FANTRAY 1-B"
label fan3 "FANTRAY 2-A"
label fan4 "FANTRAY 2-B"
label fan5 "FANTRAY 3-A"
label fan6 "FANTRAY 3-B"
label fan7 "FANTRAY 4-A"
label fan8 "FANTRAY 4-B"
label temp1 "Front MAC Temp"
label temp2 "Rear MAC Temp"
ignore temp3
ignore temp4
ignore intrusion0

View File

@ -4,18 +4,6 @@ from setuptools import setup
import os.path
import unittest
def get_platform_file_list():
data_files = []
repo_path = os.path.abspath(os.path.dirname(__file__))
data_path = os.path.join(repo_path, 'platform')
platforms = os.listdir(data_path)
for platform in platforms:
files = ['platform/' + platform + '/port_config.ini']
if os.path.isfile( os.path.join(data_path, platform, 'sensors.conf') ):
files.append('platform/' + platform + '/sensors.conf') #Not all platforms need to have a sensors.conf file
data_files.append( (os.path.join('/usr/share/sonic', platform), files) )
return data_files
def get_test_suite():
test_loader = unittest.TestLoader()
test_suite = test_loader.discover('tests', pattern='*.py')
@ -29,7 +17,6 @@ setup(name='sonic-config-engine',
url='https://github.com/Azure/sonic-buildimage',
py_modules=['minigraph', 'openconfig_acl'],
scripts=['sonic-cfggen', 'translate_acl'],
data_files=get_platform_file_list(),
install_requires=['lxml', 'jinja2', 'netaddr', 'ipaddr', 'pyyaml', 'pyangbind'],
test_suite='setup.get_test_suite',
)