[mellanox] Enhance mlnx-fw-upgrade.sh (#1994)
Install a new FW by specifying FW path (mlnx-fw-upgrade.sh /path/to/FW) or use default at '/etc/mlnx/fw-SPC.mfa' Signed-off-by: Stepan Blyschak <stepanb@mellanox.com>
This commit is contained in:
parent
e8db1846ad
commit
90f6881e08
@ -23,25 +23,46 @@ while [[ (${query_retry_count} -lt ${query_retry_count_max}) && ($? -ne "0") ]];
|
||||
${query_cmd} > /dev/null
|
||||
done
|
||||
|
||||
run_or_fail "${query_cmd}" > /tmp/mlnxfwmanager-query.txt
|
||||
function upgrade() {
|
||||
if [ ! -z "$1" ]; then
|
||||
fw_file="$1"
|
||||
if [ ! -f "$fw_file" ]; then
|
||||
>&2 echo "No such file: $fw_file"
|
||||
exit 1
|
||||
fi
|
||||
|
||||
# get current firmware version and required version
|
||||
fw_info=$(grep FW /tmp/mlnxfwmanager-query.txt)
|
||||
fw_current=$(echo $fw_info | cut -f2 -d' ')
|
||||
run_or_fail "${query_cmd} -i ${fw_file}" > /tmp/mlnxfwmanager-query.txt
|
||||
|
||||
if [[ -z ${fw_current} ]]; then
|
||||
# get current firmware version and available version from $fw_file
|
||||
fw_info=$(grep FW /tmp/mlnxfwmanager-query.txt)
|
||||
fw_current=$(echo $fw_info | cut -f2 -d' ')
|
||||
fw_available=$(echo $fw_info | cut -f3 -d' ')
|
||||
|
||||
fw_required=$fw_available
|
||||
else
|
||||
run_or_fail "${query_cmd}" > /tmp/mlnxfwmanager-query.txt
|
||||
|
||||
# get current firmware version and required version
|
||||
fw_info=$(grep FW /tmp/mlnxfwmanager-query.txt)
|
||||
fw_current=$(echo $fw_info | cut -f2 -d' ')
|
||||
fi
|
||||
|
||||
if [[ -z ${fw_current} ]]; then
|
||||
echo "Could not retreive current FW version."
|
||||
exit 1
|
||||
fi
|
||||
fi
|
||||
|
||||
if [[ -z ${fw_required} ]]; then
|
||||
if [[ -z ${fw_required} ]]; then
|
||||
echo "Could not retreive required FW version."
|
||||
exit 1
|
||||
fi
|
||||
fi
|
||||
|
||||
if [[ ${fw_current} == ${fw_required} ]]; then
|
||||
if [[ ${fw_current} == ${fw_required} ]]; then
|
||||
echo "Mellanox firmware is up to date."
|
||||
else
|
||||
else
|
||||
echo "Mellanox firmware required version is ${fw_required}. Installing compatible version..."
|
||||
run_or_fail "mlxfwmanager -i ${fw_file} -u -f -y"
|
||||
fi
|
||||
fi
|
||||
}
|
||||
|
||||
upgrade "$1"
|
||||
|
Loading…
Reference in New Issue